• Title/Summary/Keyword: cross-linked polyethylene

Search Result 78, Processing Time 0.022 seconds

A Study on Electrical Properties of Insulating Materials for Eco-friendly Distribution Power Cables (I) (친환경 배전급 전력케이블용 절연재료의 전기적 특성에 관한 연구 (I))

  • Lee, June-Ho;Kim, Chul-Ho;Cho, Young-Chul;Lee, Moon-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.3
    • /
    • pp.551-556
    • /
    • 2017
  • The cross-linked polyethylene(XLPE) has been most widely used for the power cable insulating layer because of its outstanding properties such as electrical and mechanical properties. However, XLPE is unrecyclable when disposed after replacement and demolishing because it becomes thermosetting through cross-linked process. Recently, because of growing social awareness of recycling and eco-friendly, there is growing need for the development of recyclable insulating materials that can replace XLPE. Therefore, the purpose of this study is to compare the electrical properties of XLPE and recyclable thermoplastic insulating materials. To this end, we compared and analyzed the electrical properties of XLPE and group N2 through AC breakdown test, accelerated water treeing test and accelerated life test(ALT).

Temperature Dependence of Conductivities of Recyclable Polyethylene and Polypropylene and its Effects on Electric Field Distribution in Power Cable (재활용 가능한 폴리에틸렌과 폴리프로필렌의 전도도 온도의존성과 전력케이블 내의 전계분포에 미치는 영향)

  • Lee, June-Ho;Kong, Tae-Sik;Kim, Seong-Jung;Kwon, Ki-Hyung;Cho, Kyu-Cheol;Hozumi, Naohiro
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.10
    • /
    • pp.1881-1887
    • /
    • 2011
  • In this work the recyclable new polyethylene(PE) and polypropylene(PP), which are thermoplastic, have been investigated as the eco-friendly insulating candidates to replace the cross-linked polyethylene (XLPE). The temperature dependence of conductivities of these materials has been measured and its effects on electric field and space charge distribution in polymeric insulated power cable under temperature gradient have been calculated. It is shown that the sensitivity of conductivity to temperature change has more critical influence to determine the electric field distribution in the power cable than the absolute value of conductivity does and it can be said that the temperature dependence is one of most important factors for the power cable design.

Study on the Partial Discharge Characteristics in Polyethylene Using Ultrasonic Sensors (초음파 센서를 이용한 폴리에틸렌의 부분방전특성연구)

  • 이정원;서광석;박치영;곽회로;송일근
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.283-286
    • /
    • 1996
  • A signal generated by partial discharge in low density Polyethylene (LDPE) and cross- linked polyethylene (XLPE) has been detected by ultrasonic sensors. The observed signal is analysed with the quantity of partial discharge, number of peaks, and energy ($\Sigma$y$^2$). It was found that signals between LDPE and XLPE are quite different and that the signal of XLPE has very long duration time and rising time, and that the quantity of partial discharge of XLPE is saturated. It was also found that tree retardant XLPE (TR-XLPE) has lower quantity of partial discharge, number of peaks, and energy than naturalal XLPE.

  • PDF

Effect of Cross-Linking Agents on L-Sorbose Production by Immobilized Gluconobacter suboxydans Cells

  • PARK, YOUNG-MIN;SANG-KI RHEE;EUI-SUNG CHOI;IN SIK CHUNG
    • Journal of Microbiology and Biotechnology
    • /
    • v.8 no.6
    • /
    • pp.696-699
    • /
    • 1998
  • Biological oxidation of D-sorbitol to L-sorbose using permeated and immobilized cells of Gluconobacter suboxydans was carried out to investigate the optimum reaction condition. The stabilization effect of cross-linking agents such as glutaraldehyde, tannic acid, and polyethylene imine to prevent the leakage of enzymes from beads containing permeated and immobilized cells of G. suboxydans was examined by the production of L-sorbose from the mixture of D-sorbitol and gluconic acid. The protein concentration effused from immobilized beads treated with only glutaraldehyde was $5.2\mug/m\ell$ after 20 h. The beads of G. suboxydans immobilized with alginate and cross-linked with 0.3% glutaraldehyde was the most useful for the oxidation of D-sorbitol to L-sorbose.

  • PDF

Electrophoretic Display employing OTFT-Backplane on plastic substrate

  • Ryu, Gi-Seong;Lee, Myung-Won;Song, Chung-Kun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.1178-1181
    • /
    • 2006
  • We fabricated a flexible OTFT(organic thin film transistor) backplane for the electrophoretic display. The backplane was composed of $128{\times}96pixels$ on the Polyethylene Naphthalate substrate in which each pixel had one OTFT. The OTFTs employed bottom contact structure and used the cross-linked polyvinylphenol for gate insulator and pentacene for active layer

  • PDF

Determination of Charged Particles and their Polarity by Temperature Gradient Thermally Stimulated Measurement (온도구배 열자격 측정에 의한 하전입자의 구별 및 극성 판정)

  • 권영수;강도열;국상훈
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.8
    • /
    • pp.600-609
    • /
    • 1989
  • A thermally stimulated measurement using a temperature gradient has been applied to the study of charged particles and their polarity n polymers. From the experimental results on a cross-linked polyethylene (XLPE) film is found that the TSC peaks of the trapped carriers in C peak are due to the negative polarity which is electron and the ionic carriers having negative polarity show D peak.

  • PDF

Electrical Properties and Crosslinking Characteristics of XLPE/SXLPE Blends (XLPE/SXLPE 블렌드의 전기적 성질 및 가교 특성)

  • Ko, Jung-Woo;Ha, Nam-Kyu;Suh, Kwang-S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1602-1604
    • /
    • 1999
  • Crosslinked polyethylene/silane crosslinked polyethylene (XLPE/SXLPE) blends were prepared by a twin screw extruder and their water tree and crosslinking characteristics were investigated. The water tree characteristics of XLPE were improved by the addition of SXLPE, when samples were cross- linked only by the thermorolysis of DCP (dicumyl peroxide). However, steam curing process was not good for water tree characteristics. It was also found that the degree of crosslinking of XLPE/SXLPE blends were higher than that of XLPE.

  • PDF

Development of Deterioration Detecting System for Aged ACSR-OC Conductors in HV Overhead Distribution Lines (고압 가공배전선의 노화된 ACSR-OC 도체에 대한 열화검출시스템 설계)

  • Kim, Sung-Duck;Lee, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.232-235
    • /
    • 2000
  • Design and experiments of a nondestructive system to inspect deterioration of ACSR-OC (ACSR Outdoor Cross-linked Polyethylene Insulated Wire usually used in HV overhead distribution lines presented in this paper. ACSR-OC conductor built to pollutants air for a long period would be easily progress to corrode so that it may lead to the reduction of the effective cross section area of conductors. A fault diagnosis system consisting of a solenoid sensor, a constant current source with RF frequency signal processing unit and a motor driver/controller designed and implemented. This instrument can dot the sensor output variation due to deterioration corrosion, continuously. As a result, it was shown such corrosion detector can readily be utilized estimating the diameter change due to deterioration overhead distribution lines and in giving an warning or inform before severe aged conductor lead to fail.

  • PDF

Cementless Total Hip Arthroplasty Using Ceramic Femoral Head on Cross-Linked Ultra-High-Molecular Weight Polyethylene Liner in Patients Older than 65 Years: Minimum Five-Year Follow-Up Results (세라믹 대퇴 골두 및 교차결합 초고분자량 폴리에틸렌 라이너를 이용한 65세 이상 무시멘트형 인공 고관절 전치환술: 최소 5년 중기 추시 결과)

  • Yun, Ho Hyun;Cheong, Ji Young;Sim, Hyun Bo;Park, Jae Hong
    • Journal of the Korean Orthopaedic Association
    • /
    • v.53 no.6
    • /
    • pp.490-497
    • /
    • 2018
  • Purpose: To evaluate the utility of ceramic-on-polyethylene articular bearing surface when cementless total hip arthroplasty is performed in patients older than 65 years through an analysis of the minimum five-year follow-up results using the ceramic femoral head and cross-linked polyethylene liner. Materials and Methods: From March 2010 to September 2012, 51 patients (56 hips) who were older than 65 years were enrolled in this retrospective study. The mean age at surgery was $70.9{\pm}5.1years$ old. A clinical assessment was analyzed using the Harris hip score. For the radiographic assessment, the cup inclination and anteversion, stem alignment, and wear amount were measured. The postoperative complications were also determined. Results: The mean Harris hip score was improved from preoperative 48 points to postoperative 87 points (p<0.05). The mean cup inclination was $40.9^{\circ}{\pm}6.4^{\circ}$ and the mean cup anteversion was $20.3^{\circ}{\pm}8.1^{\circ}$. The mean cup anteversion of the elevated liner-used group (16 cases) was $14.3^{\circ}{\pm}7.9^{\circ}$ and the mean cup anteversion of the neutral liner used group (40 cases) was $22.4^{\circ}{\pm}9.1^{\circ}$ (p<0.05). The mean stem alignment angle was $0^{\circ}$ (range, varus $4^{\circ}$-valgus $4^{\circ}$). The mean linear wear amount was $0.458{\pm}0.041mm$ and the average annual linear wear rate was $0.079{\pm}0.032mm/yr$. Six cases (10.7%) of intraoperative periprosthetic femoral fractures were encountered. Conclusion: Based on these results, the use of a ceramic-on-polyethylene articular bearing surface in elderly patients with cementless total hip arthroplasty is beneficial. On the other hand, careful effort is needed to prevent intraoperative periprosthetic femoral fractures.

Characteristics of Radiated Electromagnetic Wave and Partial Discharge in Power XLPE Cable (전력용 XLPE Cable의 부분방전과 방사전자파 특성)

  • Lee, Kwang-Sik;Lee, Hyun-Chul;Park, Kwang-Seo;Yoon, Dae-Hee;Lee, Sang-Hun;Kim, Jong-Hwan;Kim, Chung-Nyun;Kim, Ki-Chai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.90-95
    • /
    • 2004
  • This paper simulated partial discharge caused by 22.9[kV] power cable using XLPE(Peroxide Crosslinkable Polyethylene) insulation having the outside damage. As one of the insulation diagnostic method a radiated electromagnetic waves were measured by an UHF method using a BiconiLog antenna(EMCO-3142) and a spectrum analyzer used to measure EMI, EMC. From results of this study, It was confirmed that discharge Ogress were possible to be estimated by the proposed method.