• Title/Summary/Keyword: cross over

Search Result 2,615, Processing Time 0.03 seconds

Preform Designin Tube by Using the Hydroforming (Hydroforming을 이용한 Tube 의 예비 가공형 설계)

  • 이한남
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.03b
    • /
    • pp.39-44
    • /
    • 1999
  • Hydroforming is a forming process enabling circular metal tubes to be produced in complex cross sections along curved axial paths With the availability of advanced machine design and control They offer advantages over stamped sheet metal in lower tooling cost and structural mass The technology is relatively new so that there is no large knowledge base to assist the fundamentals of tube hydroforming technology. The purpose of this paper is found that adaptive bending condition and contact condition for bended part has uniform thickness distribution.

  • PDF

A Simple Bias-Correction Rule for the Apparent Prediction Error

  • Beong-Soo So
    • Communications for Statistical Applications and Methods
    • /
    • v.2 no.2
    • /
    • pp.146-154
    • /
    • 1995
  • By using simple Taylor expansion, we derive an easy bias-correction rule for the apparent prodiction error of the predictor defined by the general M-estimators with respect to an arbitrary measure of prediction error. Our method has a considerable computational advantage over the previous methods based on the resampling thchnique such as Cross-validaton and Boothtrap. Connections with AIC, Cross-Validation and Boothtrap are discussed too.

  • PDF

A Study on the Characteristics Analysis of Strands Melted by Over Current (과전류에 의해 용단된 소선의 특성해석에 관한 연구)

  • Choi, Chung-Seog;Kim, Hyang-Kon;Kim, Dong-Ook
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.1
    • /
    • pp.60-65
    • /
    • 2004
  • The PVC insulated flexible cords are used mainly as power supply cords of electric appliance. This electric wire is a stranded wire consisted of dozens of strands. In case stranded wires are disconnected by mechanical stress, it weakens electrically. Finally, the over current flows through stranded wires, and electrical fire occurs. In this study, we analyzed the melting properties of strands by over current, such as melting process, melting current and melting time. And we analyzed that quantity of heat for melting, a cross sectional structure, and surface structure by optical microscope and SEM. As analysis results, melting time decreased as melting current increased. And quantity of heat for melting was low, too. From the cross sectional structure of melted wire, when a melting current low and melting time long, it was found that the dendrite structure grew. However, the dendrite structure is hard to grow because growing time is not enough when a melting current high and melting time short.

A Study on the Searching Behavior of OPAC Users (온라인 열람목록의 이용행태에 관한 연구)

  • Sakong Bok-Hee
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.31 no.3
    • /
    • pp.165-208
    • /
    • 1997
  • The purpose of this study is to evaluate the characteristics of user interface that affect the searching behavior of OPAC users. and then to propose how to design user-friendly interfaces of OPACS. An experiment was conducted on two systems with different interfaces to grasp the effect of user interface to search process and search outcome. A $2\times2$ cross-over design was used for the experiment. Sixty five searchers participated in the experiment. Several statistical techniques such as carry-over effect and system effect of a $2\times2$ cross-over design, $\chi^2$ test, t- test, McNemar test, test of marginal homogeneity through maximum likelihood method, factor analysis, regression analysis, and analysis of variance were applied according to the hypotheses tested and the data analyzed.

  • PDF

A Study on Inter-leaf Transmission and Cross-leaf Transmission for Clinical Applications of the Multileaf Collimator (다엽 콜리메이터의 임상적용을 위한 엽측간 투과선량 및 엽종단간 투과선량 연구)

  • 이규찬;최진호
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.17-22
    • /
    • 2004
  • Multileaf collimator (MLC) is now rapidly replacing the lead ahoy block to shape the radiation treatment field. In addition to its defect of rectangular field shaping and increased penumbra width, it has another possible problem, and that is of radiation transmission between leaves, which needs to be maintained at as low a level as is permissible. The authors measured and analyzed the inter-leaf and cross-leaf transmissions of MLC by Varian Associates Inc, before its clinical application. The inter-leaf and cross-leaf transmissions were calculated by comparing the measured point doses in the polystyrene phantom in the open field and in a total closure of MLC. The beam profile of the inter-leaf and cross-leaf transmissions were depicted by using a water phantom. A photon beam of 6 MV was used in the measurement. The inter-leaf transmission was 1.63∼1.67%, indicating that the shielding effect of MLC is excellent. However, the cross-leaf transmission in the central area was 18.4∼18.7% and this is well over the clinically acceptable limitation of 5%. The beam profile of cross-leaf transmission displayed 80∼90% transmission near the field edge, so that the cross-leaf transmission was 14∼17% in this area. The multileaf collimator has an excellent shi디ding effect and the inter-leaf transmission is negligible so that it can be used in clinic as a good replacement of the conventional lead alloy block. However, care must be taken to avoid the cross-leaf transmission in the radiation field.

  • PDF

A comparison on the heat load of HTS current leads with respect to uniform and non-uniform cross-sectional areas

  • Han, Seunghak;Nam, Seokho;Lee, Jeyull;Song, Seunghyun;Jeon, Haeryong;Baek, Geonwoo;Kang, Hyoungku;Ko, Tae Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.3
    • /
    • pp.44-48
    • /
    • 2017
  • Current lead is a device that connects the power supply and superconducting magnets. High temperature superconductor (HTS) has lower thermal conductivity and higher current density than normal metal. For these reasons, the heat load can be reduced by replacing the normal metal of the current lead with the HTS. Conventional HTS current lead has same cross-sectional area in the axial direction. However, this is over-designed at the cold-end (4.2 K) in terms of current. The heat load can be reduced by reducing this part because the heat load is proportional to the cross-sectional area. Therefore, in this paper, heat load was calculated from the heat diffusion equation of HTS current leads with uniform and non-uniform cross-sectional areas. The cross-sectional area of the warm-end (65K) is designed considering burnout time when cooling system failure occurs. In cold-end, Joule heat and heat load due to current conduction occurs at the same time, so the cross-sectional area where the sum of the two heat is minimum is obtained. As a result of simulation, current leads for KSTAR TF coils with uniform and non-uniform cross-sectional areas were designed, and it was confirmed that the non-uniform cross-sectional areas could further reduce the heat load.

Fusing Time Characteristics Analysis of Cable according to Temperature and Insulator (온도 및 절연체에 따른 케이블의 단선시간 특성 해석)

  • Kim, Ju-Hee;Kang, Sin-Dong;Kim, Jae-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.5
    • /
    • pp.15-20
    • /
    • 2018
  • This paper describes the fusing time characteristics of Light PVC Sheathed Circular Cord(VCTF) and Tray Frame Retardant(TFR) cables according to increased temperature under over current condition. The experimental equation will be used to determine the validity and reliability of the test results. The over current flowed 3, 5 and 10 times higher than the amount of allowable current using DC power supply with DAQ(Data Acquisition) measurement system. An infrared radiation heater, which was controlled by a variable AC auto transformer, was used to increase the temperature from room temperature to 50, 100 and 150 degrees Celsius. First, two type of cables were analyzed those with different cross-sectional areas with in the same structure and those with different structures with in the same cross-sectional areas. Then, it was determined how fusing time had been influenced according to the cross-sectional areas and different structures, respectively. The cable resistance was increased by joule heating according to increasing temperature. Therefore, the allowable current of cable is decreased. Finally, the fusing time of the cable was decreased due to increased temperatures at current flow, which were 3 times the amount of allowable current. The instantaneous breakdown was observed when current flow was 5 and 10 times over the amount of allowable current. The fusing time is directly affected by the structure of cable insulation.

The amelioration of plasma lipids by Korean traditional confectionery in middle-aged women: A cross-over study with western cookie

  • Hong, Sun Hee;Kim, Mijeong;Woo, Minji;Noh, Jeong Sook;Lee, JaeHwan;Chung, Lana;Song, Yeong Ok
    • Nutrition Research and Practice
    • /
    • v.10 no.6
    • /
    • pp.590-596
    • /
    • 2016
  • BACKGROUND/OBJECTIVES: The purpose of this study was to examine whether plasma lipid profiles are affected differently by snack kinds with equal calorific values. SUBJECTS/METHODS: We compared a Korean traditional confectionery (dasik) with Western confectionery (cookie) in this regard. Controlled cross-over study consisted of two 3-week snack intake phases and for separating, a 2-week washout period (3-2-3) was carried out with 30 healthy women aged between 40-59 years old. Brown rice based Korean traditional confectionery and wheat flour based Western confectionery were used. The participants consumed either dasik or cookie every day for 3 weeks, providing 93 kcal a day. RESULTS: The total cholesterol (TC) in the dasik group had decreased significantly after 3 weeks (P < 0.05). Furthermore, in the dasik group, reduction in TC and low-density lipoprotein-cholesterol were greater than those in the cookie group (P < 0.05). CONCLUSIONS: Prioritizing functional snacks like dasik improves plasma lipid profiles; this may be useful information for individuals who cannot refrain from snacking.

Safety of Ojeok-san Extract Powder and Soft Extract in Healthy Male Volunteers, Single Center, Randomized Controlled, Cross-over Study (오적산 혼합단미엑스산제와 혼합단미연조엑스제의 안전성 평가를 위한 단일 기관, 무작위 배정, 교차 연구)

  • Shin, Hee-Ra;Park, Kyungtae;Yeom, Seung-Ryong;Kwon, Young-Dal
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.29 no.1
    • /
    • pp.63-73
    • /
    • 2019
  • Objectives The purpose of this study is to evaluate the safety of Ojeok-san extract powder and soft extract in healthy male volunteers. Methods Randomized controlled, cross over study was carried out in healthy male volunteers. Total 27 of 31 subjects meeting the inclusion criteria were enrolled and three subjects for waiting were included. To each group 12 subjects were randomly allocated by random number table. Group A took the extract powder in the first period and then took the soft extract in the second period. Group B took the medicine in the opposite order. Trial was conducted through two times of hospitalizations and all subjects had a seven-days of wash out period. Vital sign and laboratory test were checked before and after the medication. The mean difference of safety evaluation variables were analyzed by paired t-test (p<0.001) or wilcoxon signed rank test (p<0.05). The mean difference between two groups were analyzed by independent t-test (p<0.05) or Mann whitney test (p<0.05). Results As a result of all data related to vital sign and laboratory test in both group, There were no significant differences associated with the clinical trial drug between before and after the medication. And there was no adverse event associated with the clinical trial drug. Conclusions Both Ojeok-san extract powder and soft extract were found to be safe for healthy male volunteers.