• Title/Summary/Keyword: cross fracture

Search Result 294, Processing Time 0.028 seconds

Distal Tibial Physeal Fracture in a Dog

  • Park, Won-Kyu;Kim, Young-Ki;Lee, Scott;Seo, Eu-Gene;Hwang, Jae-Min;Park, Ki-Tae;Wang, Ji-Hwan;Lee, Hee-Chun;Lee, Hyo-Jong;Yeon, Seong-Chan
    • Proceedings of the Korean Society of Veterinary Clinics Conference
    • /
    • 2009.10a
    • /
    • pp.230-230
    • /
    • 2009
  • PDF

Studies on Cure Behaviors, Dielectric Characteristics and Mechanical Properties of DGEBA/Poly(ethylene terephthalate) Blends

  • Park, Soo-Jin
    • Macromolecular Research
    • /
    • v.17 no.8
    • /
    • pp.585-590
    • /
    • 2009
  • The cure behaviors, dielectric characteristics and fracture toughness of diglycidylether of bisphenol-A (DGEBA)/poly(ethylene terephthalate) (PET) blend system were investigated. The degree of conversion for the DGEBA/PET blend system was measured using Fourier transform infrared (FTIR) spectroscopy. The cure kinetics were investigated by measuring the cure activation energies ($E_a$) with dynamic differential scanning calorimetry (DSC). The dielectric characteristic was examined by dielectric analysis (DEA). The mechanical properties were investigated by measuring the critical stress intensity factor ($K_{IC}$), critical strain energy release rate ($G_{IC}$), and impact strength test. As a result, DGEBAIPET was successfully blended. The Ea of the blend system was increased with increasing PET content to a maximum at 10 phr PET. The dielectric constant was decreased with increasing PET content. The mechanical properties of the blend system were also superior to those of the neat DGEBA. These results were attributed to the increased cross-linking density of the blend system, resulting from the interaction between the epoxy group of DGEBA and the carboxyl group of PET.

Efficacy of Statins on BMB or Fracture Risk in Postmenopausal Women (스타틴이 폐경기 여성의 골밀도 혹은 골절위험에 미치는 효과 -보고된 임상연구결과 분석을 중심으로-)

  • Bang, Joon-Seok
    • Korean Journal of Clinical Pharmacy
    • /
    • v.16 no.2
    • /
    • pp.86-91
    • /
    • 2006
  • There are 3 different hypotheses on how statins may affect bones, through promoting bone formation, inhibiting bone resorption or through anti-inflammatory effect. In the 3 cross-sectional studies above, one showed increase BMD at hip and spine, one showed increase BMD only at mid-forearm and one showed that the risk reduction in fractures is not explained by the changes in BMD however, all 3 studies showed a decrease in risk of fracture associated with statins. In the 2 prospective cohort studies, one showed the use of statins was not associated with BMD at any skeletal site or decreasing the risk of fracture, and the other showed statins except pravastatin decreased in risk of vertebrate fracture but not affecting lumbar spine BMD. All of case-control studies indicated reduction in fracture risk but did not provide any data regarding BMD. 2 of the randomized, controlled studies showed no significant reduction in fracture risk as well as statins' effects on BMD. Finally, one longitudinal study showed statin use reduced fracture risk and increased BMD. Among the conflicting results shown above, even when statin use was shown to increase BMD, it does not seem to account for the reduction in fracture risk. There may be different ways that statins affect bone other than those hypotheses proposed above. Many studies seem to agree that pravastatin does not have any effect on bone. Some studies suggested that the reason statins did not achieve clinically significant increases in BMD in some studies, is due to the low affinity of statins on bone; statins are designed to act in the liver therefore their effective concentration in extrahepatic tissue is low. The limitations to those studies discussed above. Many studies did not account for the change of lifestyle while subjects' were on statins. Increases in weight bearing exercise and changes in diet might affect BMD and thus reduce risk of fractures. Mental alertness and vision acuity might prevent falls from occurring; many statin-users in the studies were young so the risk of fractures from falls would be decreased. Almost all of the studies failed exclude patients with neurological problems. During study periods, many subjects may have been started on drugs for diseases that usually occur with aging which could cause drowsiness and lead to falls. The sample sizes used in some of the trials were small and the duration of treatment and follow up might not have been long enough to see clinically relevant results.

  • PDF

Study of the fracture resistance of zirconia on posterior fixed partial dentures based on inter-abutment distance (지르코니아 고정성 국소의치의 지대치간 거리에 따른 파절저항성에 관한 연구)

  • Park, Gi-Beom;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.61-69
    • /
    • 2020
  • Purpose: Zirconia fixed partial dentures with mandibular 2nd premolar and 2nd molar as abutments are fabricated and then the effects of inter-abutment distance on fracture resistance of zirconia fixed partial dentures is studied. Materials and Methods: The materials used in this study are Cameleon S zirconia block and S2 zirconia block, which are divided into CS Group and S2 Group applying different inter-abutment distance for each material, and the sintered zirconia fixed partial denture was luted to the epoxy resin die using a temporary luting cement, and then the fracture resistance was measured by placing a 6 mm diameter hardened steel ball on the occlusal surfaces of the pontics and applying pressure at a cross head speed of 1.0 mm/min on a universal testing machine with a load cell of 5.0 kN. Results: The fracture resistance of zirconia fixed partial dentures is not significantly affected by inter-abutment distance The fracture resistance of zirconia fixed partial dentures in CS Group was significantly higher in 15 mm of inter-abutment distance than in 13 mm and 17 mm of inter-abutment distance (P < 0.05). The fracture resistance of zirconia fixed partial dentures in S2 Group was not significantly different between the three groups (P > 0.05). Conclusion: The fracture resistance of zirconia fixed partial dentures with mandibular 2nd premolar and 2nd molar as abutments does not significantly affected by the inter-abutment distance.

Dipole-Dipole Array Geoelectric Survey for Gracture Zone Detection (전기비저항 탐사법을 이용한 지하 천부 파쇄대 조사)

  • Kim, Geon Yeong;Lee, Jeong Mo;Jang, Tae U
    • Journal of the Korean Geophysical Society
    • /
    • v.2 no.3
    • /
    • pp.217-224
    • /
    • 1999
  • Although faults can be found by geological surveys, the surface traces of faults are not easily discovered by traditional geological surveys due to alluvia. In and around faults and fracture zones, the electrical resistivity appears to be lower than that of the surroundings due to the content of groundwater and clay minerals. Therefore, electrical resistivity surveys are effective to search buried faults and fracture zones. The dipole-dipole array electrical resistivity surveys, which could show the two dimensional subsurface electrical resistivity structure, were carried out in two areas, Yongdang-ri, Woongsang-eup, Yangsan-si, Kyungsangnam-do and Malbang-ri, Woedong-eup, Kyungju-si, Kyungsangpook-do. The one was next to the Dongrae Fault and the other near the Ulsan Fault was close to the region in which debatable quaternary fault traces had been found recently. From each measured data set, the electrical resistivity cross-section was obtained using the inversion program the reliability of which was analyzed using analytic solutions. A low resistivity zone was found in the inverted cross-section from the Yongdang-ri area survey data, and two low resistivity zones were found in that from the Malbang-ri area survey data. They were almost vertical and were 15∼20 m wide. Accounting the shape and the very low resistivity values of those zones (<100 Ωm)in the inverted section, they were interpreted as fracture zones although they should be proven by trenching. The reliability of the interpretation might be improved by adding some more parallel resistivity survey lines and interpreting the results in 3 and/or adding other geophysical survey.

  • PDF

구강의 횡문근육종

  • Cho, Han-Kuk;Kim, Hun-Il;Yeuh, In-Haeng;Shin, Mu-Soo
    • The Journal of the Korean dental association
    • /
    • v.12 no.12
    • /
    • pp.913-918
    • /
    • 1974
  • The authors have observed clinically and histopathologically on two cases of rhabdomyosarcomas occurred in the oral cavity. The results were as follow: 1. A case of adult pleomorphic rhabdomyosarcoma, involving the right mandibular third molar area of 52 year old male, revealed pathological fracture of the right mandibular angle area. Microscopically, sections of this tumor showed cross striations by staining of phosphotungstic acid hematoxylin. 2. A case of embryonal alveolar rhabdomyosarcoma, involving the right buccal area of one year and ten months old female, revealed severe bone destruction on the right mandibular body area. Microscopically, sections of this tumor did not show cross striations.

  • PDF

Redundancy of the Composite Twin Steel Plate Girder Bridgeaccording to the Dimension and Spacing of Cross Beams (강합성 플레이트 2-거더교의 가로보 제원 및 설치 간격에 따른 여유도 평가)

  • Park, Yong Myung;Joe, Woom Do Ji;Baek, Sung Yong
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.2
    • /
    • pp.137-146
    • /
    • 2006
  • In this paper, a numerical study on the evaluation of the redundancy according to the dimension and spacing of cross beams in the composite twin steel plate girder bridges that are generally recognized as a non-redundant load path structures, has been performed. Specifically, a two-lane three-span continuous (40+50+40m) bridge with I-section cross beams which serve as cross bracing, and without a lateral bracing were considered. The material and geometric nonlinear analyses were conducted to evaluate the ultimate loading capacity of the intact and damaged bridge in which one of the two girders is seriously fractured. Through the numerical analyses, it was recognized that there is little difference in redundancy according to the variation of the dimension and spacing of the cross beams for both intact and damaged bridges.

A Study on the Fatigue Characteristics of Spot Weld Specimen use in Vehicle Body as the Applied Load Pattern (하중작용방식에 따른 차체용 점용접체의 피로특성에 관한 연구)

  • 송삼홍;배준수;장성재
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.668-671
    • /
    • 1995
  • In this study, the fatigue charateristics of weld specimen was studied experimentally by using the various specimen types. The specimen type were tensile shesr(TS) specimen, cross tension(CT) specimen, and T typr (TT) specimen. Tensile test and fatigue test were carried out and microstucture was investigated. Finite element method was used to investigate stress distribution near nugget edge. Finally fracture mechanics approach was tried to the various specimen types.

  • PDF

New Approach for Nonlinear Analysis of Reinforced Concrete Frames (철근콘크리트 골조 비선형해석의 새로운 기법)

  • 김진근;이태규;양주경
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1992.04a
    • /
    • pp.47-52
    • /
    • 1992
  • The entire nonlinear behavior of reinforced concrete frames up to collapse, is analyzed by the displacement control method and the combined layered and nonlayered method. All of the rigidities of section are calculated approximately by a sum over all the layers for the layered method, are used the integral values over the cross section area for the nonlayered method. The spurious sensitivity to the chosen element size in the result of analysis by finite element method for the materials with strain-softening can be overcome by modifying the strain distribution based on the concept of fracture energy at plastic hinge considering the applied axial load.

  • PDF

Feasibility of Early Definitive Internal Fixation of Pelvic Bone Fractures in Therapeutic Open Abdomen

  • Choi, Kyunghak;Jung, Kwang-Hwan;Keum, Min Ae;Kim, Sungjeep;Kim, Jihoon T;Kyoung, Kyu-Hyouck
    • Journal of Trauma and Injury
    • /
    • v.33 no.1
    • /
    • pp.18-22
    • /
    • 2020
  • Purpose: Damage control laparotomy has contributed to improved survival rates for severe abdominal injuries. A large part of severe abdominal injury occurs with a concomitant pelvic bone fracture. The safety and effectiveness of internal fixation of pelvic bone fracture(s) has not been established. The aim of the present study was to evaluate infection risk in the pelvic surgical site in patients who underwent emergent abdominal surgery. Methods: This single-center retrospective observational study was based on data collected from a prospectively maintained registry between January 2015 and June 2019. Patients who underwent laparotomy and pelvic internal fixation were included. Individuals <18 and ≥80 years of age, those with no microbiological investigations, and those who underwent one-stage abdominal surgery were excluded. Comprehensive statistical comparative analysis was not performed due to the small number of enrolled patients. Results: A total of six patients met the inclusion criteria, and the most common injury mechanism was anterior-posterior compression (67%). The average duration of open abdomen was 98 hours (range, 44-98), and the time interval between abdominal closure and pelvic surgery was 98 hours. One patient (16.7%) died due to multi-organ dysfunction syndrome. Micro-organisms were identified in the abdominal surgical site in five patients (83%), with no micro-organisms in pelvic surgical sites. There was no unplanned implant removal. Conclusions: Internal fixation of pelvic bone fracture(s) could be performed in the state of open abdomen, and the advantages of early fixation may countervail the risks for cross contamination.