• Title/Summary/Keyword: critical heat flux

Search Result 296, Processing Time 0.027 seconds

Enhancement of Downward-Facing Saturated Boiling Heat Transfer by the Cold Spray Technique

  • Sohag, Faruk A.;Beck, Faith R.;Mohanta, Lokanath;Cheung, Fan-Bill;Segall, Albert E.;Eden, Timothy J.;Potter, John K.
    • Nuclear Engineering and Technology
    • /
    • v.49 no.1
    • /
    • pp.124-133
    • /
    • 2017
  • In-vessel retention by passive external reactor vessel cooling under severe accident conditions is a viable approach for retention of radioactive core melt within the reactor vessel. In this study, a new and versatile coating technique known as "cold spray" that can readily be applied to operating and advanced reactors was developed to form a microporous coating on the outer surface of a simulated reactor lower head. Quenching experiments were performed under simulated in-vessel retention by passive external reactor vessel cooling conditions using test vessels with and without cold spray coatings. Quantitative measurements show that for all angular locations on the vessel outer surface, the local critical heat flux (CHF) values for the coated vessel were consistently higher than the corresponding CHF values for the bare vessel. However, it was also observed for both coated and uncoated surfaces that the local rate of boiling and local CHF limit vary appreciably along the outer surface of the test vessel. Nonetheless, results of this intriguing study clearly show that the use of cold spray coatings could enhance the local CHF limit for downward-facing boiling by > 88%.

Effect of particle sizes on CHF enhancement and boiling characteristics of nano-fluids (나노유체의 임계열유속 및 비등특성에 미치는 나노입자 크기의 영향)

  • Jo, Byeong-Nam;Kang, Jun-One;Yoo, Jai-Suk;Kim, Hyun-Jung
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2006.12a
    • /
    • pp.125-130
    • /
    • 2006
  • The characteristics of boiling heat transfer and critical heat flux (CHF) behavior of nano-fluids were studied by using various sized silver and alumina nanoparticles. The diameter of nanoparticles was from 2 nm to 250 nm for silver and from 20nm to 40nm for alumina. Pool boiling characteristics and CHF enhancement of nano-fluids with different sized nanoparticles were compared with those of pure water and each nano-fluids. The experiment was performed at atmospheric pressure and the temperature of the pool was maintained constantly by using a flat immersed heater. The concentration of nano-fluids was uniform in all experiments as 0.01g/liter. The results showed that the measured boiling curves were shifted to the right. It demonstrated that the occurrence of nucleate boiling regime in nano-fluids retarded, compared with that of pure water. Also, in nano-fluids, the boiling curves showed that CHF of nano-fluids is significantly enhanced and represented the effect of particle size on boiling characteristics.

  • PDF

Compressibility Factor Effect on the Turbulence Heat Transfer of Super-critical Carbon Dioxide by an Elliptic-blending Second Moment Closure (타원혼합모형을 이용한 초임계상태 이산화탄소의 압축성계수에 의한 난류열전달 특성)

  • Han, Seong-Ho;Seo, Jeong-Sik;Shin, Jung-Kun;Choi, Young-Don
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.1 s.256
    • /
    • pp.40-50
    • /
    • 2007
  • The present contribution describes the application of elliptic-blending second moment closure to predict the gas cooling process of turbulent super-critical carbon dioxide flow in a square cross-sectioned duct. The gas cooling process under super-critical state experiences a drastic change in thermodynamic and transport properties. Redistributive terms in the Reynolds stress and turbulent heat flux equations are modeled by an elliptic-blending second moment closure in order to represent strongly non-homogeneous effects produced by the presence of walls. The main feature of Durbin's elliptic relaxation second moment closure that accounts for the nonlocal character of pressure-velocity gradient correlation and the near-wall inhomogeneity guaranteed by the elliptic blending second moment closure.

Numerical Analysis of Heat and Mass Transfer in a Calandria Based Reactor

  • Tupake Ravindra S;Kulkarni PS;Rajan NKS
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.281-282
    • /
    • 2003
  • Numerical investigations are carried out to study the mass flux and temperature distribution in a calandria using a 3-D RANS code. The computations made for simulations of flow and convective heat transfer with near-to working conditions. The work provides an estimate of the safe working limits of the heat dissipation by virtue of prediction of the 'hot spots' in the calandria. The work assumes significance for preliminary designs of the reactors and for detailed critical parametric analysis that would be otherwise more expensive.

  • PDF

Data Analysis of KOMPSAT Thermal Test in Simulated On-orbit Environment

  • Kim, Jeong-Soo;Chang, Young-Keun
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.1 no.2
    • /
    • pp.30-42
    • /
    • 2000
  • On-orbit thermal environment test of KOMPSAT was performed in early 1999. An analysis of the test data are addressed in this paper. For the thermal-environmental simulation of spacecraft bus, an artificial heating through the radiator zones and onto some critical heat-dissipating electronic boxes was made by Absorbed-heat Flux Method. Test data obtained in terms of temperature history were reduced into flight heater duty cycles and converted into the total electrical power required for spacecraft thermal control. Verification result of flight heaters dedicated to the bus thermal control is presented. Additionally, an exhaustive heating-control process for maintaining the spacecraft thermally safe and for realistic simulation of the orbital-thermal environment during the test are graphically shown. Qualitative suggestions to post-test model correlation are given in consequency of the analysis.

  • PDF

Evaluation of thermal stability of quasi-isotropic composite/polymeric cylindrical structures under extreme climatic conditions

  • Gadalla, Mohamed;El Kadi, Hany
    • Structural Engineering and Mechanics
    • /
    • v.32 no.3
    • /
    • pp.429-445
    • /
    • 2009
  • Thermal stability of quasi-isotropic composite and polymeric structures is considered one of the most important criteria in predicting life span of building structures. The outdoor applications of these structures have raised some legitimate concerns about their durability including moisture resistance and thermal stability. Exposure of such quasi-isotropic composite/polymeric structures to various and severe climatic conditions such as heat flux and frigid climate would change the material behavior and thermal viability and may lead to the degradation of material properties and building durability. This paper presents an analytical model for the generalized problem. This model accommodates the non-linearity and the non-homogeneity of the internal heat generated within the structure and the changes, modification to the material constants, and the structural size. The paper also investigates the effect of the incorporation of the temperature and/or material constant sensitive internal heat generation with four encountered climatic conditions on thermal stability of infinite cylindrical quasi-isotropic composite/polymeric structures. This can eventually result in the failure of such structures. Detailed critical analyses for four case studies which consider the population of the internal heat generation, cylindrical size, material constants, and four different climatic conditions are carried out. For each case of the proposed boundary conditions, the critical thermal stability parameter is determined. The results of this paper indicate that the thermal stability parameter is critically dependent on the cylinder size, material constants/selection, the convective heat transfer coefficient, subjected heat flux and other constants accrued from the structure environment.

Pool boiling heat transfer of a copper microporous coating in borated water

  • Jun, Seongchul;Godinez, Juan C.;You, Seung M.;Kim, Hwan Yeol
    • Nuclear Engineering and Technology
    • /
    • v.52 no.9
    • /
    • pp.1939-1944
    • /
    • 2020
  • Pool boiling heat transfer of a copper microporous coating was experimentally studied in borated water with a concentration of boric acid from 0.0 to 5.0 vol percent (vol%) to determine the effect of boric acid on boiling heat transfer in water. A high-temperature, thermally conductive microporous coating (HTCMC) was created by sintering copper powder with an average particle size of 67 ㎛ onto a 1 cm × 1 cm plain copper surface with a coating thickness of ~300 ㎛ within a furnace in a vacuum environment. The tests showed that the nucleate boiling heat transfer coefficient (NBHT) of HTCMC became slightly less enhanced as the concentration of boric acid increased but the NBHT coefficient values were still significantly higher than those of the plain surface. The critical heat flux (CHF) values from 0 to 1.0 vol% were maintained at ~2,000 kW/㎡, and then, they gradually decreased down to ~1,700 kW/㎡ as the concentration increased further to 5.0 vol%. It is believed that the micro-scale pores of the HTCMC were partially blocked by the high boric acid concentration during the nucleate boiling such that the small bubbles were not effectively created using the HTCMC reentrant cavities as the boric acid concentration increased.

Experimental Investigation on Forced Convective Heat Transfer Characteristic Generated to Heated Tube (가열된 튜브에서 발생하는 강제 대류열전달 특성에 관한 실험적 연구)

  • Park, Hee-Ho;Lee, Yang-Suk;Kim, Sun-Jin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.3
    • /
    • pp.90-98
    • /
    • 2006
  • The Heated Tube Facility(HIF) was fabricated to identify the forced convective heat transfer and the cooling characteristic for the hydrocarbon fuel(Jet A-1), which is used for the coolant of the regenerative cooling system. The forced convective heat transfer coefficient was calculated from the measured coolant and tube surface temperature. In case of using the Jet A-1, the maximum heat flux which the coolant can absorb was identified by determining the critical wall temperature generating the burnout on the fixed flow condition. The inlet bulk-temperature of the coolant has a direct influence on the forced convective heat transfer characteristic.

Experimental Study on the Heat Transfer Characteristics under the Supercritical Pressures (초임계압 열전달 특성에 관한 실험 연구)

  • Kang, Kyoung-Ho;Youn, Young-Jung;Park, Jong-Kuk;Choo, Yeon-Jun;Chun, Se-Young;Song, Chul-Hwa
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2242-2247
    • /
    • 2008
  • A series of experiments have been performed in a vertical tube of 9.4 mm inner diameter using the Freon, HFC-134a as working fluid medium under the supercritical pressure range. Two kinds of experiments, i.e. steady-state and pressure transient, have been carried out. As for the steady-state heat transfer experiment, the mass flux was in the range between 600 and $2000\;kg/m^2s$ and the maximum heat flux was $160\;kW/m^2$. The selected pressures were 4.1, 4.3 and 4.5 MPa which correspond to 1.01, 1.06 and 1.11 times the critical pressure, respectively. In the pressure transient experiments, the inlet pressures were varied from 3.8 to 4.5 MPa and vice versa in the pressure transient simulations. In this study, heat transfer correlation and criterion for the heat transfer deterioration are suggested under the supercritical pressures. And also heat transfer characteristics during the pressure transient are examined.

  • PDF

Enhancement of Pool Boiling Heat Transfer in Water Using Sintered Copper Microporous Coatings

  • Jun, Seongchul;Kim, Jinsub;Son, Donggun;Kim, Hwan Yeol;You, Seung M.
    • Nuclear Engineering and Technology
    • /
    • v.48 no.4
    • /
    • pp.932-940
    • /
    • 2016
  • Pool boiling heat transfer of water saturated at atmospheric pressure was investigated experimentally on Cu surfaces with high-temperature, thermally-conductive, microporous coatings (HTCMC). The coatings were created by sintering Cu powders on Cu surfaces in a nitrogen gas environment. A parametric study of the effects of particle size and coating thickness was conducted using three average particle sizes (APSs) of $10{\mu}m$, $25{\mu}m$, and $67{\mu}m$ and various coating thicknesses. It was found that nucleate boiling heat transfer (NBHT) and critical heat flux (CHF) were enhanced significantly for sintered microporous coatings. This is believed to have resulted from the random porous structures that appear to include reentrant type cavities. The maximum NBHT coefficient was measured to be approximately $400kW/m^2k$ with APS $67{\mu}m$ and $296{\mu}m$ coating thicknesses. This value is approximately eight times higher than that of a plain Cu surface. The maximum CHF observed was $2.1MW/m^2$ at APS $67{\mu}m$ and $428{\mu}m$ coating thicknesses, which is approximately double the CHF of a plain Cu surface. The enhancement of NBHT and CHF appeared to increase as the particle size increased in the tested range. However, two larger particle sizes ($25{\mu}m$ and $67{\mu}m$) showed a similar level of enhancement.