• Title/Summary/Keyword: critical current ratio

Search Result 174, Processing Time 0.031 seconds

Study on Bi-2212/Ag HTS Rutherford cabling process for high current capacity (대전류 통전용 Bi-2212/Ag 러더포드 케이블링 공정 연구)

  • Ha, Dong-Woo;Kim, Sang-Chul;Han, Il-Yong;Oh, Sang-Soo;Oh, Jae-Gn;Lee, Jeong-Hun;Song, Gyung-Jung;Lee, Nam-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.238-239
    • /
    • 2007
  • The important merit of Bi-2212/Ag wire is to apply cable as round wire state. Bi-2212 high Tc superconducting wires were fabricated in order to apply Rutherford cable near the future. Various Ag ratio from 0.22 to 0.42 of Ag tubes for PID (powder-In-Tube) process were used to investigate the workability and to prevent breakage of filaments during drawing. KERI and Nexans Korea manufactured Rutherford cabling machine by ourselves. Rutherford cables with 20 - 30 strands could be fabricated by this machine. The shape of Rutherford cables were satisfied. The critical current of Bi2212/Ag round wire with 847 filaments showed 400 A at 4.2K and self field.

  • PDF

Optimum Radial Build of a Low Aspect Ratio Tokamak Reactor

  • Hong, B.G.;Hwang, Y.S.;Kang, J.S.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.397-397
    • /
    • 2011
  • In a low aspect ratio (LAR) tokamak reactor with a superconducting toroidal field (TF) coil, the radial build of TF coil and the shield play a key role in determining the size of a reactor. For self-consistent determination of the reactor components and physics parameters, a system analysis code is coupled with one-dimensional radiation transport code. Conceptual design study of a compact superconducting LAR tokamak reactor with aspect ratio less than 2.5 was conducted and the optimum radial build was identified. It is shown that the use of an improved shielding material and high temperature superconducting magnets with high critical current density opens up the possibility of a fusion power plant with compact size and small re-circulating power simultaneously at low aspect ratio, and that by using an inboard neutron reflector instead of breeding blanket, tritium self-sufficiency is possible with outboard blanket only and thus compact sized reactor is viable.

  • PDF

Span limit and parametric analysis of cable-stayed bridges

  • Zhao, Xinwei;Xiao, Rucheng;Sun, Bin
    • Structural Engineering and Mechanics
    • /
    • v.71 no.3
    • /
    • pp.271-282
    • /
    • 2019
  • The span record of cable-stayed bridges has exceeded 1,000 m, which makes research on the maximum possible span length of cable-stayed bridges an important topic in the engineering community. In this paper, span limit is discussed from two perspectives: the theoretical span limit determined by the strength-to-density ratio of the cable and girder, and the engineering span limit, which depends not only on the strength-to-density ratio of materials but also on the actual loading conditions. Closed form equations of both theoretical and engineering span limits of cable-stayed bridges determined by the cable and girder are derived and a detailed parametric analysis is conducted to assess the engineering span limit under current technical conditions. The results show that the engineering span limit of cable-stayed bridges is about 2,200 m based on materials used available today. The girder is the critical member restricting further increase in the span length; its compressive stress is the limiting factor. Approaches to increasing the engineering span limit are also presented based on the analysis results.

Operational Characteristics of SFCL using Magnetic Coupling of Coils (코일의 자기결합을 이용한 초전도 사고전류제한기의 동작특성)

  • Lim, Sung-Hun;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.68-70
    • /
    • 2007
  • The operational characteristics of superconducting fault current limiter (SFCL) using magnetic coupling of coils were investigated. This SFCL consists of a high-Tc superconducting (HTSC) element and two coils with series or parallel connection on the same iron. This SFCL has the merit that the operational current of SFCL can be increased higher than the critical current of the superconducting element by adjusting the inductance ratio between two coils. To confirm its operation, the circuit for the fault simulation was constructed. From the measured voltage and current of the SFCL, it was confirmed that the resistance of HTSC element comprising this SFCL increased more than that of HTSC element's independent operation.

  • PDF

ZVT Series Capacitor Interleaved Buck Converter with High Step-Down Conversion Ratio

  • Chen, Zhangyong;Chen, Yong;Jiang, Wei;Yan, Tiesheng
    • Journal of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.846-857
    • /
    • 2019
  • Voltage step-down converters are very popular in distributed power systems, voltage regular modules, electric vehicles, etc. However, a high step-down voltage ratio is required in many applications to prevent the traditional buck converter from operating at extreme duty cycles. In this paper, a series capacitor interleaved buck converter with a soft switching technique is proposed. The DC voltage ratio of the proposed converter is half that of the traditional buck converter and the voltage stress across the one main switch and the diodes is reduced. Moreover, by paralleling the series connected auxiliary switch and the auxiliary inductor with the main inductor, zero voltage transition (ZVT) of the main switches can be obtained without increasing the voltage or current stress of the main power switches. In addition, zero current turned-on and zero current switching (ZCS) of the auxiliary switches can be achieved. Furthermore, owing to the presence of the auxiliary inductor, the turned-off rate of the output diodes can be limited and the reverse-recovery switching losses of the diodes can be reduced. Thus, the efficiency of the proposed converter can be improved. The DC voltage gain ratio, soft switching conditions and a design guideline for the critical parameters are given in this paper. A loss analysis of the proposed converter is shown to demonstrate its advantages over traditional converter topologies. Finally, experimental results obtained from a 100V/10V prototype are presented to verify the analysis of the proposed converter.

Increase of Operational Current in a SFCL using Series or Parallel Coupling of Coils (코일의 직.병렬결합을 이용한 초전도 사고전류제한기의 동작전류 증가)

  • Lim, Sung-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.46-51
    • /
    • 2007
  • The fault current limiting characteristics of superconducting fault current limiter(SFCL) using magnetic coupling of two coils were investigated. This SFCL consists of a high-TC superconducting(HTSC) element and two coils with series or parallel connection on the same iron. In normal time, the inner magnetic fluxes generated by two coils are canceled in case that the HTSC element keeps superconducting state. However, in case that the resistance of the HTSC element happens by a short-circuit the magnetic fluxes, not cancelled, induce the voltages across two coils and the fault current can be limited by the impedance of this SFCL. This SFCL has the merit that the operational current of SFCL can be increased higher than the critical current of the superconducting element by adjusting the inductance ratio between two coils. To confirm its operation, the circuit for the fault simulation was constructed. From the measured voltage and current of the SFCL, it was confirmed that the operating current of this SFCL increased more than that of HTSC element's independent operation.

Clinical Characteristics of Smoking Asthmatics

  • Ha, Eun Sil;Kim, Hye Ok;Lee, Kyoung Ju;Lee, Eun Joo;Hur, Gyu Young;Jung, Ki Hwan;Lee, Sung Yong;Kim, Je Hyeong;Lee, Sang Yeub;Shin, Chol;Shim, Jae Jeong;Kang, Kyung Ho;Yoo, Se Hwa;In, Kwang Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.67 no.6
    • /
    • pp.506-511
    • /
    • 2009
  • Background: The smoking prevalence in asthma patients are similar to those in the general population. Asthma and active cigarette smoking can interact to create more severe symptoms, an accelerated decline in lung function and impaired therapeutic responses. Accordingly, asthmatics with a history of smoking were examined to define the clinical characteristics and lung function of smoking asthmatics. Methods: The medical records of 142 asthmatics with a known smoking history were reviewed. The patients were divided into three groups according to their smoking history - current smokers, former smokers and non-smokers. The clinical characteristics, lung function, and annual declines of the forced expiratory volume in one second ($FEV_1$) were compared. Results: Fifty-three of the 142 patients (37%) were current smokers, 24 were former smokers (17%) and 65 were non-smokers (45%). The patients with a hospital admission history during the previous year included 16 current smokers (30%), 4 former smokers (17%) and 7 non-smokers (11%) (p=0.02). The mean $FEV_1$ (% predicted) was 76.8${\pm}$19.8%, 71.6${\pm}$21.1% and 87.9${\pm}$18.7% for current smokers, former smokers and non-smokers, respectively (p< 0.001). The $FEV_1$/forced vital capacity (FVC) (ratio, %) values were 63.6${\pm}$12.6%, 59.3${\pm}$14.9% and 72.1${\pm}$11.8% in current smokers, former smokers and non-smokers, respectively (p<0.001). The corresponding mean values for the individual $FEV_1$ slopes were not significant (p=0.33). Conclusion: Asthmatic smokers demonstrated higher hospital admission rates and lower lung function. These findings suggest that the smoking history is an important predictor of a poor clinical outcome in asthma patients.

An Analysis on Current Limiting characteristics of an SFCL using Magnetic Coupling between Two Coils through Computer Simulation (시뮬레이션을 통한 자기결합을 이용한 초전도 한류기의 전류제한 특성 분석)

  • Kim, Jin-Seok;Ahn, Jae-Min;Lim, Sung-Hun;Moon, Jong-Fil;Kim, Jae-Chul;Kim, Chul-Hwan;Hyun, Ok-Bae
    • Progress in Superconductivity and Cryogenics
    • /
    • v.10 no.1
    • /
    • pp.42-47
    • /
    • 2008
  • In this paper, the fault current limiting characteristics for the superconducting fault current limiter(SFCL) using magnetic coupling between two coils were investigated. The SFCL consists of a high-$T_c$ superconducting(HTSC) element and two coils. This SFCL has different characteristics that depend on the connection form, the winding direction and the inductance ratio of two coils. The impedance and the operational current of the SFCL can be adjusted higher or lower than the resistance and the critical current of HTSC element. Therefore, the SFCL can change the amplitude of the limited fault current. To confirm it, the HTSC element was modeled and the fault current limiting characteristics of the SFCL were analysed through computer simulation. It was obtained from the analysis that the connection form and the winding direction of two coils of the SFCL were the important design parameters.

Optimal Design of 6.6kV-200A DC Reactor Type High-Tc Superconducting: Fault Current Limter (6.6kV-200A급 DC 리액터형 고온초전도한류기의 최적설계)

  • 서호준;이승제;고태국
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.99-104
    • /
    • 2002
  • This study deals with the optimal design of a DC reactor type high-Tc superconducting fault current limiter(SFCL). The condition in which the cost function is minimized under given constraints is one of the things to be first considered in developing SFCLS. This condition is a group of the values corresponding to the variables the cost function depends on. In this paper, the length of tape was taken as a dependent variable, the inductance of DC reactor and the turns ratio of magnetic core reactors as independent variables. For the SFCL available at the level of 6.6kV-200A, we examined 4 cases; at the fault times of 80msec, 50msec, 30msec and 10msec. Since thyristors would be utilized instead of diodes, we chose the result at 10msec as the basic data. Considering safety factor 30%, our optimal design was decided to be the inductance 570mH, the critical current over 620A, the turns ratio 0.89 and the fault time within 20msec.

Analysis of Thermal Recovery Characteristics for $SF^6$ Gas-Blast Arc within Laval Nozzle (Laval Nozzle에 대한 $SF^6$ 아크의 열적회복특성 해석)

  • Song, Gi-Dong;Lee, Byeong-Yun;Gyeong-Yeop;Park, Jeong-Hu
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.9
    • /
    • pp.522-529
    • /
    • 2002
  • In this paper, computer simulations of the physical Phenomena occurring in the arc region before and after current zero were carried out to evaluate the thermal recovery characteristics of a Laval nozzle. A commercial CFD program "PHOENICS" is used for the simulation and the user-coded subroutines to consider the arcing phenomena were added to this program by the authors. The computed results were verified by the comparison with the test results presented by the research group of GE Co.(General Electric Company). In order to investigate the state of the arc region after current zero, the simulation was carried out with three steps. They are steady state arc simulation, transient arc simulation before current zero, and transient hot-gas flow simulation after current zero. The semi-experimental arc radiation model is adapted to consider the radiation energy transport and Prandtl's mixing length model is employed as the turbulence model. The electric field and the magnetic field were calculated with the same grid structure used for the simulation of the flow field. The post-arc current was calculated to evaluate the thermal recovery characteristics after current zero. Compared with the results obtained by GE Co., it has been found that the critical RRRV(ratio of rise of recovery voltage) will be determined previously by this study.his study.