• 제목/요약/키워드: coupling method

검색결과 2,400건 처리시간 0.025초

폐루프 광섬유자이로스코프의 전기적 교차결합에 의한 불감응 영역 오차 분석 (Analysis of Deadzone Error by Electrical Cross-coupling on a Closed-loop Fiber Optic Gyroscope)

  • 정경호;정길도
    • 제어로봇시스템학회논문지
    • /
    • 제20권4호
    • /
    • pp.437-442
    • /
    • 2014
  • Due to electrical cross-coupling between modulation voltage and photodetector output in a closed-loop fiber optic gyro, deadzone inevitably occurs. In this paper, deadzone error by cross-coupling effect was analyzed and the overcoming method was suggested. Simulation and measurement results show the main reason for deadzone is mainly related to electrical cross-coupling, and it can be effectively reduced by square-wave dithering method.

PE 피복형 파형강관의 플랜지 이음부 설계에 관한 연구 (A Study on Flange Coupling Design of Polyethylene Corrugated Steel Pipe)

  • 김태규;이호영;양상민
    • 대한기계학회논문집A
    • /
    • 제31권3호
    • /
    • pp.403-408
    • /
    • 2007
  • The concrete pipe(Hume, PC) and polyethylene(PE) pipe are usually used for dram pipe in local market. Hume pipe, however, is heavy and needs the high cost of construction and PC pipe has a disadvantage to easily occur the deformation by the outside pressure even though it is light and constructible. The corrugated steel pipe coated with polyethylene is used increasedly because it is durable, constructible and economical. However, it is not used for sewage or waste water because it is hard to guarantee the watertight property on the coupling part. In this study, we studied on the flange coupling and the method of its construction to guarantee the watertight property and easy to use. If the developed flange coupling and method are used on a construction field, the economical property, constructible property and structural safety can be guaranteed.

자기유도방식과 LC공진을 이용한 무선전력전송기기 (Wireless Power Transmission using Electromagnetic Inductive Coupling and LC Resonant)

  • 이승환;김현민;김희제;김수원
    • 전기학회논문지
    • /
    • 제62권3호
    • /
    • pp.349-354
    • /
    • 2013
  • Wireless power transmission introduced by Tesla has instrumented by many scientists of the world. This technique first was utilized as wireless communications such as radio in long range transmission. And contactless transmission using inductive property was used on white goods. In 2007, MIT' lab introduced that new wireless power transmission by magnetic resonance which has about 50% efficiency and 2M transmission distances, it was a chance to refocus a new possibility of wireless power transmission. In this paper, using LC coupling compensate the short distances of contactless transmission, this simple method could transmit about 30cm distances. Using this approach, it can be solved the short transmission distances, a drawback of Electromagnetic inductive coupling method.

스트럿-타이 모델을 이용한 철근 콘크리트 연결보의 전단강도와 변형능력 (The Shear Strength and Deformability of R/C Coupling Beams using Strut-and-Tie Models)

  • 장상기;홍성걸
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.349-352
    • /
    • 2004
  • In this study, a strut-and-tie models for the coupling beam based on deformations are presented. To design shear-dominated R/C coupling beams, it is important to consider shear strength deterioration with required deformations. This study proposes the method of estimating shear strength of the reinforced concrete coupling beams. The proposed method determines the strain states from target displacements based on the nonlinear truss analysis. The estimated horizontal strain of beam is then used in calculating the strength of the diagonal strut with compatibility conditions. The deterioration of shear strength of the coupling beam depends on the strength degradation of struts due to plastic deformations.

  • PDF

부구조물 합성법을 이용한 슬라이딩 모드 조건을 갖는 비선형 구조의 동적 모델 수립 (Dynamic Model Establishment of a Nonlinear Structure with Sliding Mode Condition Using the Substructure Synthesis Method)

  • 김대관;이민수;고태환;한재흥
    • 한국소음진동공학회논문집
    • /
    • 제16권8호
    • /
    • pp.814-821
    • /
    • 2006
  • A structural coupling method is developed for the dynamic analysis of a nonlinear structure with concentrated nonlinear hinge joints or sliding lines. The component mode synthesis method is extended to couple substructures and the nonlinear models. In order to verify the improved coupling method, a numerical plate model consisting of two substructures and torsional springs, is synthesized by using the proposed method and its modal parameters are compare with analysis data. Then the coupling method is applied to a three-substructure-model with the nonlinearity of sliding lines between the substructures. The coupled structural model is verified from its dynamic analysis. The analysis results show that the improved coupling method is adequate for the structural nonlinear analyses with the nonlinear hinge and sliding mode condition.

Dynamic Analysis of Bending-Torsion Coupled Beam Structures Using Exact Dynamic Elements

  • Hong, Seong-Wook;Kang, Byung-Sik;Park, Joong-Youn
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제4권1호
    • /
    • pp.15-22
    • /
    • 2003
  • Beams are often subject to bending-torsion coupled vibration due to mass coupling and/or stiffness coupling. This paper proposes a dynamic analysis method using the exact dynamic element for bending-torsion coupled vibration of general plane beam structures with joints. The exact dynamic element matrix for a bending-torsion coupled beam is derived, and the detailed procedure of using the exact dynamic element matrix is also presented. Three examples are provided for validating and illustrating the proposed method. The numerical study proves the proposed method to be useful for dynamic analysis of bending-torsion coupled beam structures with joints.

인가주파수에 따른 결합형 광변조기 특성변화 (Characterization of coupling optical modulator to the applied frequency)

  • 강기성
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제9권6호
    • /
    • pp.584-592
    • /
    • 1996
  • Coupling optical modulator which on the $LiTaO_3$ substrate is fabricated by using proton exchange method and self-aligned method. Proton exchange of proton diffusion method was applied to pattern a waveguide on $LiTaO_3$ substrate. The annealing at >$400^{\circ}C$ was carded out to control waveguide width and depth. The depths of the two annealed optical waveguides, which were measured by using .alpha.-step, were 1.435 K.angs. and 1.380 K.angs. Using .alpha.-step facility, we examined that the width of waveguides is increased from 5.mu.m to 6.45 .mu.m and 6.3.mu.m due to the annealing effects. The process of proton exchange was done at 150.deg. C for 120 min, >$200^{\circ}C$ for 60 min and annealing process was done at >$400^{\circ}C$ for 90 min, >$400^{\circ}C$ for 60 min. The high speed coupling optical modulator has very good figures of merits; the measured high frequency power were achieved.

  • PDF

환원판이 결합된 원통셸의 진동해석 (Vibration Analysis of Combined Cylindrical Shells with an Annular Plate)

  • 김영완;정강
    • 한국소음진동공학회논문집
    • /
    • 제13권10호
    • /
    • pp.767-776
    • /
    • 2003
  • The theoretical method is developed to Investigate the nitration characteristics of the combined cylindrical shells with an annular plate joined to the shell at any arbitrary axial position. The structural coupling between shell and plate is simulated using two types of artificial springs a translational spring is introduced for translational coupling and a rotational spring is used for rotational coupling. The springs are continuously distributed along circumferential direction. Using the Rayleigh-Ritz method the natural frequencies and mode shapes of the combined shell with an annular plate examine. The effect of Inner-to-outer radius ratio, axial position of annular plate and length-to-radius ratio of shell on vibration characteristics of combined cylindrical shells is studied. The theoretical results are verified by comparison with FEM results.

Multiscale simulation based on kriging based finite element method

  • Sommanawat, Wichain;Kanok-Nukulchai, Worsak
    • Interaction and multiscale mechanics
    • /
    • 제2권4호
    • /
    • pp.353-374
    • /
    • 2009
  • A new seamless multiscale simulation was developed for coupling the continuum model with its molecular dynamics. Kriging-based Finite Element Method (K-FEM) is employed to model the continuum base of the entire domain, while the molecular dynamics (MD) is confined in a localized domain of interest. In the coupling zone, where the MD domain overlaps the continuum model, the overall Hamiltonian is postulated by contributions from the continuum and the molecular overlays, based on a quartic spline scaling parameter. The displacement compatibility in this coupling zone is then enforced by the Lagrange multiplier technique. A multiple-time-step velocity Verlet algorithm is adopted for its time integration. The validation of the present method is reported through numerical tests of one dimensional atomic lattice. The results reveal that at the continuum/MD interface, the commonly reported spurious waves in the literature are effectively eliminated in this study. In addition, the smoothness of the transition from MD to the continuum can be significantly improved by either increasing the size of the coupling zone or expanding the nodal domain of influence associated with K-FEM.

A New Assessment for the Total Harmonic Contributions at the Point of Common Coupling

  • Han, Jong-Hoon;Lee, Kyebyung;Song, Chong Suk;Jang, Gilsoo;Byeon, Gilsung;Park, Chang-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.6-14
    • /
    • 2014
  • A new method to determine the total harmonic contributions of several customers and the utility at the point of common coupling is presented. The proposed method can quantify the individual harmonic impact of each suspicious harmonic source at the point of common coupling. The individual harmonic impact index is then used to assess the total harmonic contribution of each harmonic source. This index can be calculated by the results processed from instantaneous harmonic voltage and current phasor values. The results demonstrate the performance of the proposed method in terms of steady-state accuracy and response to time-varying operating conditions. The proposed index can be used for billing purposes to control harmonic distortion levels in power systems.