• Title/Summary/Keyword: coupling circuit

Search Result 473, Processing Time 0.035 seconds

Modeling and Analysis of Silicon Substrate Coupling for CMOS RE-IC Design (CMOS RE-IC 설계를 위한 실리콘 기판 커플링 모델 및 해석)

  • 신성규;어영선
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.393-396
    • /
    • 1999
  • A circuit model of silicon substrate coupling for CMOS RF-IC design is developed. Its characteristics are analyzed by using a simple RC mesh model in order to investigate substrate coupling. The coupling effects due to the substrate were characterized with substrate resistivity, oxide thickness, substrate thickness. and physical distance. Thereby the silicon substrate effects are analytically investigated and verified with simulation. The analysis and simulation of the model have excellent agreements with MEDICI(2D device simulator) simulation results.

  • PDF

A Contactless Energy Transfer Circuit Using Coreless Low-profile PCB Transformer (코어없는 초박형 PCB 변압기를 이용한 무접점 전력변환 회로)

  • 최병조
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.505-508
    • /
    • 2000
  • A coreless printed circuit board(PCB) transformer is employed in a contactless energy transfer circuit that achieves an efficient power conversion at the presence of a considerable airgap between the source and the load side. A half-bridge series resonant converter is selected as the contactless energy transfer circuit in order to minimize the detrimental effects of large leakage inductance small magnetizing inductance and poor coupling coefficient of the coreless PCB transformer. The operation and performance of the proposed contactless power converter are verified on a 7 W experimental circuit that provides an 18V/0.4A output from a 210-370 V input source.

  • PDF

Dynamic Characteristics Analysis of Linear BLOC motor using Finite Element Method Coupling with External Circuit Model (외부회로가 결합된 선형 BLDC 전동기의 유한요소법을 이용한 동특성 해석)

  • Chung, Koon-Seok;Kim, Mi-Jung;Moon, Ji-Woo;Cho, Yun-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.7
    • /
    • pp.1231-1235
    • /
    • 2007
  • This paper presents the dynamic characteristics of a linear brushless dc (BLDC) motor with permanent magnet excitation for the precision conveyor according to the load condition. Dynamic performance of the linear BLDC motor driven with 6 step inverter such as thrust force and speed is simulated by finite element method coupling with external circuit and measured for the prototype motor. The results of finite element analysis are compared to the experimental results and verify reliability.

Characteristic Analysis of Contactless Energy Transmission System using 3D Finite Element Method (3차원 유한요소법을 이용한 비접촉 전력 전달 장치 특성 해석)

  • Woo Kyung-Il;Park Han-Seok;Cho Yun-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.1
    • /
    • pp.22-26
    • /
    • 2005
  • This paper proposes the calculation method of magnetic coupling coefficient of the contactless energy transmission system by 3D finite element method with a variation of the secondary core positions. The primary, secondary self and leakage inductances and the capacitances of a resonant circuit are calculated by the finite element analysis results. From these values, the magnetic coupling coefficients are obtained. The secondary voltages and currents according to the secondary core positions are calculated by using the resonant circuit and compared.

Implementation of Effective Wireless Power Transmission Circuit for Low Power System

  • Lho, Young Hwan
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.846-849
    • /
    • 2018
  • Wireless power transfer (WPT) is the technology that enables the power to transmit electromagnetic field to an electrical load without the use of wires. There are two kinds of magnetic resonant coupling and inductive coupling ways transmitting from the source to the output load. Compared with microwave method for energy transfer over a long distance, the magnetic resonance method has the advantages of reducing the barrier of electromagnetic wave and enhancing the efficiency of power transmission. In this paper, the wireless power transfer circuit having a resonant frequency of 13.45 MHz for the low power system is studied, and the hardware implementation is accomplished to measure the power transmission efficiency for the distance between the transmitter and the receiver.

A Study on Broadband Hybrid Design Using Vertically Installed Planar Circuit with Partially Removed Ground Plane (일부 접지면이 제거된 수직 장착 평면 회로를 이용한 광대역 하이브리드 설계에 관한 연구)

  • Kim In-Seon;Lee Cheol-Soo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.7 s.98
    • /
    • pp.661-670
    • /
    • 2005
  • In this paper, the microstrip $90^{\circ}$ hybrid to provide -3dB coupling and $90^{\circ}$ phase difference at broadband frequency range of 2 to 6 GHz is designed. This proposed hybrid is composed of 3-section. The two outside section are realized by symmetrical edge coupled lines, but on the other hand the middle section consists of VIP(Vertically Installed Planar) circuit. The ground part of VIP circuit is partially removed to get tight coupling, particularly. This hybrid is easy to realize due to microstrip structure and has good holing flexibility by taking advantage of VIP circuit as a control point of optimization. The proposed hybrid provide satisfactory performance as compared with simplicity of structure and fabrication first of all.

Performance Evaluations of a Novel Prototype of High Frequency Non-Contact Power Transformer

  • Gamage, Laknath;Ishitobi, Manabu;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.4 no.1
    • /
    • pp.12-17
    • /
    • 2004
  • In this paper, a practical implementation to reduce leakage flux of a high-frequency inverter based non-contact type power transformer composed of EE-shape ferrite cores is presented for key technology of the next generation medical use X-ray CT scanner system. Design consideration for the unique structure of the non-contact power transformer with 900mm in diameter is also introduced. The complete non-contact transformer is actually arranged by several blocks of the magnetic circuit assembled by using 10 small EE shape cores with 120mm in length. It is experimentally and analytically discussed from a reduced leakage flux viewpoint related to its inductively coupling coefficient. A practical method to lower the leakage flux is described based on effective Copper-Sheet- Treatment placed on EE shape ferrite cores of magnetic circuit.

Study of Crosstalk in Multi-conductor system and Equivalent Circuit Model (인접선 신호선의 누화(Crosstalk)에 대한 해석 및 회로 모델에 관한 연구)

  • Lee, Dong-Jae;Ha, Jung-Rae;Kim, Jong-Min;Nah, Wan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2211_2212
    • /
    • 2009
  • 본 논문에서는 GaAs-Transistor가 접합된 전송선로 사이에서 발생되는 Crosstalk의 영향에 관한 연구를 하였다. 이 모델의 해석을 위해 인접선에서의 Crosstalk의 이론적인 접근을 하고, 3D Full Wave 시뮬레이션과 Circuit 시뮬레이션을 통해 해석하는 Crosstalk의 해석방법에 대한 모델을 제시하고자 한다. 또한 Coupling 된 Solder Bump의 Equivalent Circuit Model을 제시함으로써 Solder Bump의 Coupling이 Crosstalk의 영향에 미치는 영향에 대해 규명하고자 한다.

  • PDF

A Study on the measurement and Method of Partial Discharge in High Voltage CV Cable (고압 CV 케이블에서의 부분방전 측정과 위치검출 방법에 관한 연구)

  • Song Jae-Yong;Seo Hwang-Dong;Park Dae-Won;Kil Gyung-Suk;Han Moon-Sup;Jang Dong-Wook
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.867-872
    • /
    • 2005
  • This paper describes the measurement and location method of partial discharges in high voltage CV cables. Coupling capacitors were used to detect partial discharge signal. Impedance characteristic of the coupling circuit and an amplifier with a high Common Mode Rejection Ratio(CMRR) were studied to improve sensitivity of the circuit. From the calibration experiment, the sensitivity of the partial discharge detection circuit was about 100pC. Also, we confirmed that the location of partial discharges in cables can be estimated by calculation of time difference between the first pulse and the second one reflected from the other end of the cable.