• 제목/요약/키워드: coupled operation

검색결과 517건 처리시간 0.038초

Analysis on Current Limiting Characteristics of Transformer Type SFCL with Additionally Coupled Circuit

  • Lim, Seung-Taek;Ko, Seok-Cheol;Lim, Sung-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.533-539
    • /
    • 2018
  • In this paper, the transformer type superconducting fault current limiter (SFCL) with additionally coupled circuit was suggested and its peak fault current limiting characteristics due to the fault condition to affect the fault current were analyzed through the fault current limiting tests. The suggested transformer type SFCL is basically identical to the previous transformer type SFCL except for the additional coupled circuit. The additional coupled circuit, which consists of the magnetically coupled winding to the primary and the secondary windings together with another superconducting element and is connected in parallel with the secondary winding of the transformer type SFCL, is contributed to the peak fault current limiting operation for the larger transient fault current directly after the fault occurrence. To confirm the fault current limiting operation of the suggested SFCL, the fault current limiting tests of the suggested SFCL were performed and its effective peak fault current limiting characteristics were analyzed through the analysis on the electrical equivalent circuit.

고속열차 중련운전 설계에 관한 연구 (The design concept of the multi-coupled operation for high speed train)

  • 최권희;장대성;정병호;이병석;김국진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.877-882
    • /
    • 2005
  • The definition of multi-coupled operation is that coupled two trainsets is able to be operated one trainset identically. That is to say, the one driver, coupled two trainsets can operate the traction and braking system, control vehicle doors, phanto-graph, HVAC and passenger room lighting system etc, such as one trainset controlling. This study will provide high speed train design engineer with introducing multi-coupled operation system electrically and presentation automatic complex coupler mechanism, and then this paper will be applied to design next generation high speed train system such as Jun-la/Ho-nam line

인터리브드 PWM 컨버터에서의 Coupled Inductor 해석 (Analysis of Coupled Inductor for Interleaved PWM converter)

  • 신동설;차헌녕;이종필;유동욱;김희제
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.330-331
    • /
    • 2011
  • The interleaving method is usually used to reduce the ripple of output current of filter inductor in parallel operation of PWM DC/DC converter. Although the current ripple of filter inductor decreases, each current ripple of filter inductor is not decreased. In this study, the operation of interleaved buck converter with coupled inductor is analyzed in each operation mode. It is verified through experiment. The possibility of application to grid connected inverter with parallel operation is identified.

  • PDF

Parallel PCS Interconnection Current Surge Elimination Technique Using a Coupled Inductor

  • Choe, Jung-Muk;Byen, Byeng-Joo;Choe, Gyu-Ha
    • Journal of Power Electronics
    • /
    • 제14권5호
    • /
    • pp.827-833
    • /
    • 2014
  • This study proposes a coupled inductor method for the parallel operation of a power conditioning system (PCS). When primary and secondary currents flow in the same direction in a coupled inductor, total flux and inductance are cancelled; when currents flow in opposite directions, each flux becomes an individual inductor. These characteristics are applied in the parallel operation of a PCS. To connect at a grid code, abnormal current, which is barred under the grid connection code, is blocked by using a coupled inductor. A design based on the capacity and current duration time of a PCS is verified through hardware implementation. Experiment results show the effectiveness of variance reduction.

중련편성 열차를 위한 효율적인 사건기록기 운영방안 (Effective event recorder operation method for multi-coupled trainset)

  • 최권희;정병호;민평오;오용석;이종우
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1428-1432
    • /
    • 2007
  • One of the most important targets of transportation is to transport human and commodities to the destination safely. Railway has low risk, compared with land, ocean and flight route and it assures high security as well as high speed driving, since it runs on regular track. However, train accident may result in tragic accident due to small carelessness, so special event recorder is preferably used in order for clarity of responsibility in case of accident, maintenance of signal device and defect analysis. JRU(Juridical Recorder Unit) for ATC/ATS/ATP can be more advanced event recorder. Event recorder of KTX-I which is running now is installed one by one on each leading car and last car, and operation plan of event recorder in case of single trainset is suggested. But regarding train operation of multi-coupled trainset operation such as KTX-II, more detailed study is required for event recorder revitalization and record data process method. Therefore, this research aims at operation plan used in existing event recorder, and suggests effective operation and management plan of event recorder in multi-coupled trainset such as new High Speed Train.

  • PDF

Selection of Coupling Factor for Minimum Inductor Current Ripple in Multi-winding Coupled Inductor Used in Bidirectional DC-DC Converters

  • Kang, Taewon;Suh, Yongsug
    • Journal of Power Electronics
    • /
    • 제18권3호
    • /
    • pp.879-891
    • /
    • 2018
  • A bidirectional dc-dc converter is used in battery energy storage systems owing to the growing requirements of a charging and discharging mode of battery. The magnetic coupling of output or input inductors in parallel-connected multi modules of a bidirectional dc-dc converter is often utilized to reduce the peak-to-peak ripple size of the inductor current. This study proposes a novel design guideline to achieve minimal ripple size of the inductor current under bidirectional power flow. The newly proposed design guideline of optimized coupling factor is applicable to the buck and boost operation modes of a bidirectional dc-dc converter. Therefore, the coupling factor value of the coupled inductor does not have to be optimized separately for buck and boost operation modes. This new observation is explained using the theoretical model of coupled inductor and confirmed through simulation and experimental test.

터보펌프-가스발생기 연계시험의 모드 변환 중간 작동점 분석 (Analysis for Operation Point Change in Mode Transition at the Turbopump-Gas Generator Coupled Test)

  • 남창호;김승한;박순영;김철웅
    • 한국추진공학회지
    • /
    • 제13권1호
    • /
    • pp.43-50
    • /
    • 2009
  • 터보펌프-가스발생기 연계시험에서 작동점 변경을 위해 거치는 중간 작동점의 특성을 시스템 모사 프로그램으로 검토하였다. 중간 작동점에서 펌프 토출압, 가스발생기 혼합비, 가스발생기 온도, 가스발생기 압력 등의 변수를 안전한 시험기 운용을 고려하여 검토하였다. 터보펌프-가스발생기 연계시험기와 엔진시스템을 비교한 결과 중간 작동점이 차이는 작지만 서로 다르고 이는 엔진 시스템에서 연소기 유량에 따른 연소압 변화가 발생하기 때문이다. 연소기 배관의 밸브 변경을 우선할 때 중간 작동점이 보다 안전한 영역에 위치한다.

Analysis and Implementation of a New Single Switch, High Voltage Gain DC-DC Converter with a Wide CCM Operation Range and Reduced Components Voltage Stress

  • Honarjoo, Babak;Madani, Seyed M.;Niroomand, Mehdi;Adib, Ehsan
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.11-22
    • /
    • 2018
  • This paper presents a single switch, high step-up, non-isolated dc-dc converter suitable for renewable energy applications. The proposed converter is composed of a coupled inductor, a passive clamp circuit, a switched capacitor and voltage lift circuits. The passive clamp recovers the leakage inductance energy of the coupled inductor and limits the voltage spike on the switch. The configuration of the passive clamp and switched capacitor circuit increases the voltage gain. A wide continuous conduction mode (CCM) operation range, a low turn ratio for the coupled inductor, low voltage stress on the switch, switch turn on under almost zero current switching (ZCS), low voltage stress on the diodes, leakage inductance energy recovery, high efficiency and a high voltage gain without a large duty cycle are the benefits of this converter. The steady state operation of the converter in the continuous conduction mode (CCM) and discontinuous conduction mode (DCM) is discussed and analyzed. A 200W prototype converter with a 28V input and a 380V output voltage is implemented and tested to verify the theoretical analysis.

Loosely Coupled Resonant DAB 컨버터의 안정적인 초기 구동을 위한 동작 주파수 설계 (Operating Frequency Design for Stable Initial Operation of Loosely Coupled Resonant DAB Converter)

  • 백승혁;김성민;이재홍;이승환
    • 전력전자학회논문지
    • /
    • 제26권6호
    • /
    • pp.437-445
    • /
    • 2021
  • This paper proposes an operating frequency design method that limits the voltage applied to aload-side converter during the initial operation of a loosely coupled resonant dual-active bridge (LCR-DAB) converter and an initial operating strategy that applies it. The LCR-DAB converter uses two wireless power transfer coils instead of the high-frequency transformer of the general DAB converter. The wireless power coil has a physical distance of several tens of millimeter or more between the two coils; thus, the LCR-DAB converter is a bidirectional isolated power conversion system that can easily achieve high insulation performance. However, for the initial operation of the LCR-DAB, if the power-side converter is operated at the resonance frequency while the load-side converter is not operating, then a very high voltage due to resonance is applied to the load-side converter, thereby causing damage to the converter. Therefore, a method that can stably charge the DC link voltage of the secondary-side converter during the initial operation is needed. This paper proposes a method to initially charge the secondary-side DC link by operating the primary-side converter at a frequency with limited voltage gain rather than at a steady-state operating frequency. The validity of the proposed frequency design method and initial operating sequence is verified through simulation and experimentation of the 1 KW LCR-DAB converter.

A Narrow Bandwidth Microstrip Band-Pass Filter with Symmetrical Frequency Characteristics

  • Jun, Dong-Suk;Lee, Hong-Yeol;Kim, Dong-Young;Lee, Sang-Seok;Nam, Eun-Soo
    • ETRI Journal
    • /
    • 제27권5호
    • /
    • pp.643-646
    • /
    • 2005
  • This letter proposes a band-pass filter (BPF) with two transmission zeros based on a combination of parallel coupling and end coupling of half-wave transmission lines. The fabricated BPF exhibited a narrow bandwidth and two transmission zeros near the pass-band due to the end-coupled and shielding waveguide. At the center operation frequency of 60 GHz, the 20 dB bandwidth of the BPF is 1.0 GHz, which is almost 2% of the center operation frequency, and the insertion loss is 3.12 dB. Two transmission zeros reach approximately 40 dB at 58.5 and 62.5 GHz. The simulation results almost agree with the measured results.

  • PDF