• Title/Summary/Keyword: coupled analysis

Search Result 4,183, Processing Time 0.047 seconds

Error Analysis of Delivered Dose Reconstruction Using Cone-beam CT and MLC Log Data (콘빔 CT 및 MLC 로그데이터를 이용한 전달 선량 재구성 시 오차 분석)

  • Cheong, Kwang-Ho;Park, So-Ah;Kang, Sei-Kwon;Hwang, Tae-Jin;Lee, Me-Yeon;Kim, Kyoung-Joo;Bae, Hoon-Sik;Oh, Do-Hoon
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.332-339
    • /
    • 2010
  • We aimed to setup an adaptive radiation therapy platform using cone-beam CT (CBCT) and multileaf collimator (MLC) log data and also intended to analyze a trend of dose calculation errors during the procedure based on a phantom study. We took CT and CBCT images of Catphan-600 (The Phantom Laboratory, USA) phantom, and made a simple step-and-shoot intensity-modulated radiation therapy (IMRT) plan based on the CT. Original plan doses were recalculated based on the CT ($CT_{plan}$) and the CBCT ($CBCT_{plan}$). Delivered monitor unit weights and leaves-positions during beam delivery for each MLC segment were extracted from the MLC log data then we reconstructed delivered doses based on the CT ($CT_{recon}$) and CBCT ($CBCT_{recon}$) respectively using the extracted information. Dose calculation errors were evaluated by two-dimensional dose discrepancies ($CT_{plan}$ was the benchmark), gamma index and dose-volume histograms (DVHs). From the dose differences and DVHs, it was estimated that the delivered dose was slightly greater than the planned dose; however, it was insignificant. Gamma index result showed that dose calculation error on CBCT using planned or reconstructed data were relatively greater than CT based calculation. In addition, there were significant discrepancies on the edge of each beam while those were less than errors due to inconsistency of CT and CBCT. $CBCT_{recon}$ showed coupled effects of above two kinds of errors; however, total error was decreased even though overall uncertainty for the evaluation of delivered dose on the CBCT was increased. Therefore, it is necessary to evaluate dose calculation errors separately as a setup error, dose calculation error due to CBCT image quality and reconstructed dose error which is actually what we want to know.

Susceptibility Loci Associations with Prostate Cancer Risk in Northern Chinese Men

  • Wang, Na-Na;Xu, Yong;Yang, Kuo;Wei, Dong;Zhang, Yao-Guang;Liu, Ming;Shi, Xiao-Hong;Liang, Si-Ying;Sun, Liang;Zhu, Xiao-Quan;Yang, Yi-Ge;Tang, Lei;Zhao, Cheng-Xiao;Wang, Xin;Chen, Xin;Hui, Juan;Zhang, Yu-Hong;Zhu, Ling;Yang, Fan;Zhang, Yu-Rong;Yang, Ze;Wang, Jian-Ye
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.5
    • /
    • pp.3075-3078
    • /
    • 2013
  • Background: KLK3 gene products, like human prostate-specific antigen (PSA), are important biomarkers in the clinical diagnosis of prostate cancer (PCa). G protein-coupled receptor RFX6, C2orf43 and FOXP4 signaling plays important roles in the development of PCa. However, associations of these genes with PCa in northern Chinese men remain to be detailed. This study aimed to investigate their impact on occurrence and level of malignancy. Methods: All subjects were from Beijing and Tianjin, including 266 cases with prostate cancer and 288 normal individuals as controls. We evaluated associations between clinical covariates (age at diagnosis, prostate specific antigen, Gleason score, tumor stage and aggressive) and 6 candidate PCa risk loci, genotyped by PCR- high resolution melting curve and sequencing methods. Results: Case-control analysis of allelic frequency of PCa associated with PCa showed that one of the 6 candidate risk loci, rs339331 in the RFX6 gene, was associated with reduced risk of prostate cancer (odds ratio (OR) = 0.73, 95% confidence interval (CI) =0.57-0.94, P = 0.013) in northern Chinese men. In addition, subjects with CX (CC+TC) genotypes had a decreased risk for prostrate cancer compared to those carrying the TT homozygote (OR =0.64, 95% CI = 0.45- 0.90, P = 0.008). The TT genotype of 13q22 (rs9600079, T) was associated with tumor stage (P=0.044, OR=2.34, 95% CI=0.94-5.87). Other SNPs were not significantly associated with clinical covariates in prostate cancer (P > 0.05). Conclusions. rs339331 in the RFX6 gene may be associated with prostate cancer as a susceptibility locus in northern Chinese men.

The Effects of Use Patterns and Service Quality on Performance and Use Satisfaction on Library Information System (도서관의 이용패턴과 서비스품질이 정보화성과지각 및 만족에 미치는 영향)

  • Jung, Hyung-Shik;Yeoum, Seoung-Yeoub
    • Journal of Global Scholars of Marketing Science
    • /
    • v.18 no.4
    • /
    • pp.217-244
    • /
    • 2008
  • Consumers' overall satisfaction on a specific library use is inferred to be primarily accrued from their performance perception and use satisfaction on the library information service system as recent information technology is being rapidly improved and more libraries are being equipped with advanced information technologies. However, prior research has been conducted only on general library service quality and visitors' satisfaction, leaving the important aspects of visitors' library use and information performance perception. Thus, the objectives of this research are to examine the effect of library use patterns such as general visit for book reading and more professional information search, coupled with service quality, on the library users' performance perception on the information system that in turn, affects library use satisfaction on the same information system. More specifically, this study examines whether library visitors perceive differenltly the information system performance according to their library use patterns such that professional library users may have less positive on information system service due to their higher expectation or more positive perception on it due to variety of information uses and positive judgment on advanced information system. Next, three dimensions of service quality, consisting of interaction, outcome, and physical evidence quality in visitors' library use situations, are hypothesized to affect performance perception on library information system. Thirdly, the performance perception on library information system is hypothesized to influence the system use satisfaction while these two constructs are to affect visitors' overall satisfaction. we develop the following research model in accordance with the above theoretical reasoning. All variables used in this study(General Use Patterns, Professional Use Patterns, Interaction Quality, Outcome Quality, Physical Evidence Quality, Information Performance Perception, Information Use Satisfaction, Overall Satisfaction) were defined operationally based on the underlying prior studies. A survey was conducted with prepared questionnaires to about 400 visitors of a specific university library. Among them, 353 proper questionnaires were finally used for the analyses. Two-step approach was used to test the hypotheses. First, confirmatory factor analysis was conducted to guarantee the validity and reliability of variables. The results showed that all variables had not only convergent and discriminant validity, but also reliability. Then, research model was examined with a structural equation using LISREL 8.30 version. The fitness of the research model was found to be within the acceptable level. The findings of this study are as follows. The professional library use pattern was found to affect the users' performance perception on the library information system while the general library use pattern was not. Second, three dimensions of service quality (interaction, outcome, physical evidence) were found to influence the information system performance respectively while none of them was not to information use satisfaction. Third, library users' performance perception on the information system operation was found to affect the information system use satisfaction, both of which also influence users' overall satisfaction of the library. The findings of this study suggest that contemporary libraries strengthen their advanced information system operation in a way of user orientation and more importantly maximize their visitors' utilization of information system, accompanying proper material and various program development. This study conceptualized the new constructs of library users' performance perception on the information system and information use satisfaction which could better explain library users' overall satisfaction. Thus, furture study related with library service could utilize the constructs of information system performance and satisfaction as well as the variety of library use patterns in the users' viewpoints.

  • PDF

Analytical Methods of Hydroxyl Radical Produced by TiO2 Photo-catalytic Oxidation (TiO2 광촉매 산화 반응에서 생성된 수산기 라디칼 분석 방법)

  • Kim, Seong Hee;Lee, Sang-Woo;Kim, Jeong Jin;Kim, Soon-Oh
    • Journal of the Mineralogical Society of Korea
    • /
    • v.28 no.3
    • /
    • pp.245-253
    • /
    • 2015
  • The performance of $TiO_2$ photo-catalytic oxidation process is significantly dependent on the amount of hydroxyl radicals produced during the process, and it is an essential prerequisite to quantify its production. However, precise and accurate methods for quantification of hydroxyl radicals have not been developed so far. For this reason, this study was initiated to compare existing methods for analysis of hydroxyl radicals produced by $TiO_2$ photo-catalytic oxidation and to propose a new method to overcome the limitation of established methods. To simulate $TiO_2$ photo-catalytic oxidation process, Degussa P25 which has been widely used as a standard $TiO_2$ photo-catalyst was used with the dose of 0.05 g/L. The light source of process was UVC mercury low-pressure lamp (11 W, $2,975mW/cm^2$). The results indicate that both potassium iodide (KI)/UV-vis spectrometer and terephthalic acid (TPA)/fluorescence spectrometer methods could be applied to qualitatively measure hydroxyl radicals via detection of triiodide ion ($I_3{^-}$) and 2-hydroxyterephthalic acid which are produced by reactions of iodine ion ($I^-$) and TPA with hydroxyl radicals, respectively. However, it was possible to quantitatively measure hydroxyl radicals using TPA method coupled with high-performance liquid chromatograph (HPLC). The analytical results using TPA/HPLC method show that hydroxyl radical of 0.013 M was produced after 8 hours operation of photo-catalytic oxidation under specific experimental conditions of this study. The proposed method is expected to contribute to precise the evaluation of the performance of photo-catalytic oxidation process.

A Study on the Landscape Symbolism of Tongdo-palkyung and It's Narrative Structure (통도팔경(通度八景)의 경관상징성(景觀象徵性)과 서사구조(敍事構造))

  • Rho, Jae-Hyun
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.28 no.1
    • /
    • pp.27-37
    • /
    • 2010
  • This study tries to illuminate the features and values of the Buddhist temple Palkyung by closely examining the forms, structures, and meanings of Tongdo-palkyung(通度八景) handed down at Tongdosa Temple, the best among Korea's Buddhist temples with its three treasures of Buddha, law of Buddha and Buddhist monks. The findings of this study can be summarized as the following. First of all, it reveals the meaning of the geographical name Yeongchuksan(靈鷲山), located to the west of Tongdosa, and a spectacular sight spread like an eagle's spread wings, as well as its location and spatial features. In particular, the arrangement features of a number of attached hermitages clearly show Yeongchuksan's world as being a temple with buddhist treasures. The multi-layered unfolding and centripetal intention of the scenery can be perceived through the shape of the Sshangryongnongju(雙龍弄珠形), around Tongdosa and the feature of the enclosed landscape encircling the steps of Hyeolcheo(穴處) Geumganggyedan. The substances and components of Tongdopalkyung include sound-based spectacles derived from Beoneumgu(梵音具) creating sounds related to religious rituals to enlighten and redeem mankind, such as Yeongji(影池: a holy pond with shadow reflections), drum sounds, and bell sounds along with physical features like pine trees, Dae(臺), waterfalls, Dongcheon (洞天), and a glow in the sky. On the other hand, Palkyung's geographical arrangements exhibit a circular spatial formation based on the main motif as Buddhist symbolism, beginning with the 'Gukjangsangseokpyo(國長生石標)' awakening the territoriality of Tongdosa and locating the first scene 'Mupunghansong(舞風寒松)' in its introductory area, with the features of water, bridge, pine grove, and Iljumun(gate) to stand for the influx. Six other scenes including 'Anyangdongdae(安養東臺)' are placed in the sacred precincts around Daeungjeon and Geumganggyedan while the glow of sunset at 'Danjoseong' just outside the domain closes the symbolic circular formation of the Tongdopalkyung, which coincides with the development of the Mandala figure symbolizing 'Gusanpalhae(九山八海)' centered in Sumisan(須彌山). What is more, Tongdopalkyung, while excluding primary scenic elements inside the temple, maximizes the domain of the mountain's entrance and the effects of the multi-layered mountain, mountain upon mountain, by intensifying the influx and centripetal qualities. The Tongdopalkyung analysis reveals the antithesis of four-coupled scenes conveying buddhist principles and thoughts on the basis of seasons, directions, space and time to display a narrative structural landscape when viewed from the temple's territoriality. Likewise, the characteristics and porch structures of Tongdopalkyung are tools and language of symbols to both externally strengthen the temple's territoriality and to internally, maximize the desires to the Land of Happiness as well as intensify religious wishes and the Mandala's multi-layered qualities through the meanings of time and space.

Mineralogical, Micro-textural, and Geochemical Characteristics for the Carbonate Rocks of the Lower Makgol Formation in Seokgaejae Section (석개재 지역 하부 막골층 탄산염암의 광물조성, 미세구조 및 지화학적 특성)

  • Park, Chaewon;Kim, Ha;Song, Yungoo
    • Economic and Environmental Geology
    • /
    • v.51 no.4
    • /
    • pp.323-343
    • /
    • 2018
  • This study defines the mineralogical, micro-textural and geochemical characteristics for the carbonate rocks and discusses the fluids that have affected the depositional environment of the Lower Makgol Formation in Seokgaejae section. Based on analysis of X-ray Diffraction (XRD), Scanning Electron Microscope-Energy Dispersive X-ray Spectrometry (SEM-EDS), Electron Probe Micro Analyzer-Wavelength Dispersive X-ray Spectrometry (EPMA-WDS) and Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry (LA-ICP-MS), carbonate miorofacies in the basal and the lower members of the Makgol Formation are distinguished and classified into four types. Type 1 dolomite (xenotopic interlocking texture) and Type 2 dolomite (idiotopic interlocking texture) have relatively high Mg/Ca ratio, flat REE pattern, low Fe and Mn. Extensively interlocking textures in these dolomites indicate constant supply of Mg ion from hypersaline brine. Type 3 and Type 4 dolomite (scattered and loosely-aggregated texture) have relatively moderate Mg/Ca ratio, MREE enriched pattern, low to high Fe and Mn. These partial dolomitization indicate limited supply of Mg ion under the influx of meteoric water with seawater. Also, the evidence of Fe-bearing minerals, recrystallization and relatively high Fe and Mn in Type 4 indicates the influence of secondary diagenetic fluids under suboxic conditions. Integrating geochemical data with mineralogical and micro-textural evidence, the discrepancy between the basal and the lower members of the Makgol Formation indicates different sedimentary environment. It suggest that hypersaline brine have an influence on the basal member, while mixing meteoric water with seawater have an effect on the lower member of the Makgol Formation.

Comparison of Solidification Pre-treatment Methods for the Determination of δ13C of Dissolved Organic Carbon: Alkaline Persulfate Oxidation-Carbonate Precipitation vs. Freeze Drying (용존유기탄소의 δ13C : 분석시 고형화 전처리 방법 비교 알칼린 과황산칼륨산화 탄산침전과 동결건조)

  • Jeon, Byeong-Jun;Park, Hyun-Jin;Choi, Woo-Jung;Park, Yong-Se;Lee, Sang-Mo;Yoon, Kwang-Sik
    • Korean Journal of Environmental Agriculture
    • /
    • v.36 no.2
    • /
    • pp.113-118
    • /
    • 2017
  • BACKGROUND: The carbon (C) isotope ratio (${\delta}^{13}C$) of dissolved organic C (DOC) is an indicator of water pollution source. In this study, the potential use of two pre-treatments for the ${\delta}^{13}C$ analysis, alkaline persulfate oxidation coupled with carbonate precipitation (precipitation) and freeze drying (drying), were compared to suggest a more feasible pre-treatment method. METHODS AND RESULTS: Two reference materials with different ${\delta}^{13}C$ values were used for the experiments; chemical grade glucose ($-12.0{\pm}0.02$‰) and pig manure compost extract ($-23.3{\pm}0.04$‰). In the precipitation method, the measured ${\delta}^{13}C$ values were consistently lower than the theoretically calculated values as dissolved $CO_2$ could not be removed due to the alkaline property of the reagents and the dissolution of air $CO_2$ into the alkaline solution. The drying method also resulted in more negative ${\delta}^{13}C$ than the calculated ${\delta}^{13}C$; however, the difference was systematic ($3.9{\pm}0.3$‰) and there was a strong correlation (${\delta}^{13}C_{calculated}=0.87{\times}{\delta}^{13}C_{measured}-0.624$, $r^2=0.98$) between the calculated and measured ${\delta}^{13}C$. Calibration of ${\delta}^{13}C$ using the relationship between the calculated and the measured ${\delta}^{13}C$ values produced reliable and accurate ${\delta}^{13}C$ values. CONCLUSION: Our results suggest that the drying method is more accurate pre-treatment method to minimize the influence of air $CO_2$ compared to the precipitation method for the determination of ${\delta}^{13}C$ of DOC.

A STUDY ON IN VIVO AND IN VITRO AMALGAM CORROSION (아말감의 구강내 부식 및 인공 부식에 관한 연구)

  • Lim, Byong-Mok;Kwon, Hyuk-Choon;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.1-33
    • /
    • 1997
  • The objective of this study was to analyze the in vitro and in vivo corrosion products of low and high copper amalgams. The four different types of amalgam alloy used in this study were Fine cut, Caulk spherical, Dispersalloy, and Tytin. After each amalgam alloy and Hg were triturated according to the directions of the manufacturer by means of the mechanical amalgamator(Amalgam mixer. Shinhung Co. Korea), the triturated mass was inserted into a cylindrical metal mold which was 12mm in diameter and 10mm in height. The mass was condensed by 150Kg/cm compressive force. The specimen was removed from the mold and aged at room temperature for about seven days. The standard surface preparation was routinely carried out by emery paper polishing under running water. In vitro amalgam specimens were potentiostatically polarized ten times in a normal saline solution at $37^{\circ}C$(potentiostat : HA-301. Hukuto Denko Corp. Japan). Each specimen was subjected to anodic polarization scan within the potential range -1700mV to+400mV(SCE). After corrosion tests, anodic polarization curves and corrosion potentials were obtained. The amount of component elements dissolved from amalgams into solution was measured three times by ICP AES(Inductive Coupled Plasma Atomic Emission Spectrometry: Plasma 40. Perkim Elmer Co. U.S.A.). The four different types of amalgam were filled in occlusal and buccal class I cavities of four human 3rd molars. After about five years the restorations were carefully removed after tooth extraction to preserve the structural details including the deteriorated margins. The occlusal surface, amalgam-tooth interface and the fractured surface of in vivo amalgam corrosion products were analyzed. In vivo and in vitro amalgam specimens were examined and analyzed metallographically by SEM(Scanning Electron Microscope: JSM 840. Jeol Co. Japan) and EDAX(Energy Dispersive Micro X-ray Analyser: JSM 840. Jeol Co. Japan). 1. The following results are obtained from in vitro corrosion tests. 1) Corrosion potentials of all amalgams became more noble after ten times passing through the in vitro corrosion test compared to first time. 2) After times through the test, released Cu concentration in saline solution was almost equal but highest in Fine cut. Ag and Hg ion concentration was highest in Caulk spherical and Sn was highest in Dispersalloy. 3) Analyses of surface corrosion products in vitro reveal the following results. a)The corroded surface of Caulk spherical has Na-Sn-Cl containing clusters of $5{\mu}m$ needle-like crystals and oval shapes of Sn-Cl phase, polyhedral Sn oxide phase. b)In Fine cut, there appeared to be a large Sn containing phase, surrounded by many Cu-Sn phases of $1{\mu}m$ granular shapes. c)Dispersalloy was covered by a thick reticular layer which contained Zn-Cl phase. d)In Tytin, a very thin, corroded layer had formed with irregularly growing Sn-Cl phases that looked like a stack of plates. 2. The following results are obtained by an analysis of in vivo amalgam corrosion products. 1) Occlusal surfaces of all amalgams were covered by thick amorphous layers containing Ca-P elements which were abraded by occlusal force. 2) In tooth-amalgam interface, Ca-P containing products were examined in all amalgams but were most clearly seen in low copper amalgams. 3) Sn oxide appeared as a polyhedral shape in internal space in Caulk spherical and Fine cut. 4) Apical pyramidal shaped Sn oxide and curved plate-like Sn-Cl phases resulted in Dispersalloy. 5) In Tytin, Sn oxide and Sn hydroxide were not seen but polyhedral Ag-Hg phase crystal appeared in internal space which assumed a ${\beta}_l$ phase.

  • PDF

Risk Assessment Aluminum Levels of Circulating Agricultural Products in Korea (국내 다소비 농산물의 알루미늄 농도 모니터링 및 농산물 섭취로 인한 위해도 평가)

  • An, Jae-Min;Hong, Kyong-Suk;Kim, Sung-Youn;Kim, Ji-Hye;Yu, Kyong-Eun;Kim, Hyo-Young;Park, Hyoung-Dal;Lee, Jae-Hwon;Kim, Dong-Ho
    • Korean Journal of Environmental Agriculture
    • /
    • v.34 no.4
    • /
    • pp.336-344
    • /
    • 2015
  • BACKGROUND: This study was carried out to collect occurrence data on aluminum in 12 type agricultural products and assess dietary exposure risk to the Korean population health for aluminum concentration in agricultural products.METHODS AND RESULTS: Aluminum analysis samples were performed using microwave device and Inductively Coupled Plasma Optical Emission Spectrometer. The LOD(Limit of Detection) for aluminum was 0.851 μg/kg, while the LOQ(Limit of Quantitation) was 2.838 μg/kg and recovery was 97.6% for aluminum. The average levels of aluminum in mg/kg were 0.526 for rice, 0.546 for Korean cabbage, 1.316 for corn, 6.207 for soybean, 0.549 for sweet potato, 0.257 for potato, 6.963 for spinach, 1.213 for carrot, 0.524 for garlic, 0.950 for radish, 1.015 for leek, and 3.511 for Welsh onion. The dietary exposures of aluminum through usual intake were polished rice 89.31 μg/day, Korean cabbage 33.14 μg/day, corn 0.66 μg/day, soybean 3.72 μg/day, sweet potato 6.86 μg/day, potato 4.96 μg/day, spinach 45.96 μg/day, carrot 6.79 μg/day, garlic 2.36 μ g/day, radish 7.32 μg/day, leek 2.23 μg/day and Welsh onion 43.89 μg/day, taking 0.57%, 0.21%, 0.00%, 0.02%, 0.04%, 0.03%, 0.04%, 0.04%, 0.02%, 0.05%, 0.01% and 0.28% of PTWI(2 mg/kg b.w./week), respectively.CONCLUSION: The levels of overall dietary exposure to aluminum for Korean population through intake of agricultural product was far below the recommended JECFA level, indicating of least possibility of risk.

Design of Thermo-optic Switch with Low Power Consumption by Electrode Optimization (전극 구조의 최적화를 통한 저전력 열광학 스위치 설계)

  • Choi, Chul-Hyun;Kong, Chang-Kyeng;Lee, Min-Woo;Sung, Jun-Ho;Lee, Seung-Gol;Park, Se-Geun;Lee, El-Hang;O, Beom-Hoan
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.5
    • /
    • pp.266-271
    • /
    • 2009
  • We designed a thermo-optic switch based on a directional coupler with not only a high extinction ratio but also significantly low power consumption. The switch operates by using the thermo-optic effect of the polymer which the refractive index changes by heating the electrode. If the electrode is not powered (OFF), the input light will be coupled completely to the other waveguide. When the electrode is powered at a certain level (ON), input light launched into the input waveguide will remain in that waveguide due to the lower index adjusted in the other waveguide. The switch based on the directional coupler was designed using the generalized extinction ratio curve and the lateral shift of the input waveguide. The coupling length is 1,610 ${\mu}m$ and the extinction ratios are -28 and -30 dB for ON and OFF states, respectively. The electrode structures were optimized by thermal analysis. The transported heat into the waveguide is increased, as the electrode width (w) is increased and the center distance between the electrode and the waveguide (d) is decreased. Also, because the heat generated in the electrode affects the other waveguide, the temperature difference between two waveguides is varied as the given w and d. There are specific conditions which have the maximum of the temperature difference. That of the temperature difference is increased as the width and the temperature of the electrode are increased. Especially, when the switch is designed using the condition with the maximum of the temperature difference for switching, the temperature of the electrode can be decreased. We expect this condition will be the novel method for the reduction of the power consumption in a thermo-optic switch.