• Title/Summary/Keyword: counting on

Search Result 1,319, Processing Time 0.028 seconds

Design of visitor counting system using edge computing method

  • Kim, Jung-Jun;Kim, Min-Gyu;Kim, Ju-Hyun;Lee, Man-Gi;Kim, Da-Young
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.7
    • /
    • pp.75-82
    • /
    • 2022
  • There are various exhibition halls, shopping malls, theme parks around us and analysis of interest in exhibits or contents is mainly done through questionnaires. These questionnaires are mainly depend on the subjective memory of the person being investigated, resulting in incorrect statistical results. Therefore, it is possible to identify an exhibition space with low interest by tracking the movement and counting the number of visitors. Based on this, it can be used as quantitative data for exhibits that need replacement. In this paper, we use deep learning-based artificial intelligence algorithms to recognize visitors, assign IDs to the recognized visitors, and continuously track them to identify the movement path. When visitors pass the counting line, the system is designed to count the number and transmit data to the server for integrated management.

A Probability Model based on Counting Method to Improve Broadcast Reliability over VANET (차량이동통신용 브로드캐스트의 신뢰성 향상을 위한 확률 모델)

  • Virdaus, Irvanda Kurniadi;Kang, Moonsoo;Shin, Seokjoo;Lee, Chung Ghiu;Choi, Yonghoon
    • The Journal of Korean Institute of Next Generation Computing
    • /
    • v.13 no.5
    • /
    • pp.51-70
    • /
    • 2017
  • The reliability of broadcasting over vehicular ad hoc networks (VANETs) is one of the most critical factors for driving safety applications. There exists limitations to improve the reliability of broadcast transmissions in saturated VANETs where previous proposals in literature tackle the problem by heuristically adapting the size of the contention window (CW). This paper considers improving the reliability by proposing a new probability model based on the counting methods of permutations and combinations, which counts all the possible cases of broadcast failures in a single-hop broadcast transmission for a given CW. From the model, we calculate the best CW size given the number of contention nodes, which significantly improves the reliability and satisfying the timely dissemination of emergency broadcasting messages. Through extensive VANET simulations with varying densities, we show that our model maintains near 100 percent success rate for single-hop broadcast as well as multi-hop broadcast (e.g. 40 hops) and achieves minimal broadcast delay.

A counting-time optimization method for artificial neural network (ANN) based gamma-ray spectroscopy

  • Moonhyung Cho;Jisung Hwang;Sangho Lee;Kilyoung Ko;Wonku Kim;Gyuseong Cho
    • Nuclear Engineering and Technology
    • /
    • v.56 no.7
    • /
    • pp.2690-2697
    • /
    • 2024
  • With advancements in machine learning technologies, artificial neural networks (ANNs) are being widely used to improve the performance of gamma-ray spectroscopy based on NaI(Tl) scintillation detectors. Typically, the performance of ANNs is evaluated using test datasets composed of actual spectra. However, the generation of such test datasets encompassing a wide range of actual spectra representing various scenarios often proves inefficient and time-consuming. Thus, instead of measuring actual spectra, we generated virtual spectra with diverse spectral features by sampling from categorical distribution functions derived from the base spectra of six radioactive isotopes: 54Mn, 57Co, 60Co, 134Cs, 137Cs, and 241Am. For practical applications, we determined the optimum counting time (OCT) as the point at which the change in the Kullback-Leibler divergence (ΔKLDV) values between the synthetic spectra used for training the ANN and the virtual spectra approaches zero. The accuracies of the actual spectra were significantly improved when measured up to their respective OCTs. The outcomes demonstrated that the proposed method can effectively determine the OCTs for gamma-ray spectroscopy based on ANNs without the need to measure actual spectra.

Review of the Gross Alpha for Characterization of Radioactive Waste (방사성폐기물 특성평가를 위한 전알파 분석법 고찰)

  • Kim, Hyuncheol;Lim, Jong-Myoung;Jang, Mee;Park, Ji-Young
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2_spc
    • /
    • pp.227-235
    • /
    • 2020
  • In this study, we discussed the limitations of gross alpha measurements for the characterization of radioactive wastes produced in nuclear facilities through experimental tests and Monte Carlo N-particle transport simulations. The determination of gross alpha is essential for the disposal of radioactive waste produced in nuclear facilities in Korea. The measurements of gross alpha are easy to perform and yield rapid analytical results, but it cannot be used for quantitative analysis. The error of counting efficiency for gross alpha with various masses of the deposit on planchets using KCl and 241Am was determined. The relative deviation of the counting efficiency in samples having the same mass was 20%. Uranium was extracted from the soil through acid leaching and extraction chromatography, and the concentration of U determined by inductively coupled plasma-mass spectrometry (ICP-MS) was compared with the results for gross alpha. The gross alpha was underestimated by 50% compared to the U concentration by ICP-MS. The counting efficiency depended on the energy from the alpha emitters, which differed by up to three times in determination of the counting efficiency depending on the kinds of alpha radionuclides of interest. Therefore, the gross alpha is not compatible with the sum of radioactivity for each alpha emitter and is suitable as a screening method.

Induction and resuscitation of viable but nonculturable Edwardsiella tarda (Edwardsiella tarda의 비배양성 생존상태(VBNC) 유도 및 소생 특성)

  • Kang, Nam I;Kim, Eunheui
    • Korean Journal of Microbiology
    • /
    • v.52 no.3
    • /
    • pp.313-318
    • /
    • 2016
  • Bacteria in the viable but nonculturable (VBNC) state fail to produce colonies on routine bacteriological media, but are still alive in the state of very low metabolic activity. The aim of the present study was to induce the VBNC state of the Edwardsiella tarda using sea water microcosm under starvation conditions at $10^{\circ}C$ and to investigate resuscitation of the VBNC cells in temperatures changed from 10 to $25^{\circ}C$, with and without additives. E. tarda entered into the VBNC state within about 42-84 days of incubation in the microcosm. Throughout this period, the total cell counts as determined using acridine orange direct counting remained near the original inoculum level of ${\sim}10^8cells/ml$. The live cell counts measured with direct viable counting, on the other hands, declined to ${\sim}10^4cells/ml$. When the VBNC cells were incubated with addition of yeast extract, fish muscle extract or serum at $25^{\circ}C$, the ratios of resuscitated samples were 37%, 23%, and 37%, respectively. The characteristics of resuscitated E. tarda were consistent with those of the original E. tarda. When the resuscitated E. tarda were intraperitoneally injected into olive flounders, all fishes died within 5 days, indicating that the VBNC E. tarda might retain its pathogenic potential. Therefore, E. tarda under starvation conditions in the winter enter into the VBNC state and the VBNC E. tarda cells resuscitated at summer and autumn seawater temperature are considered to be pathogen continuously to olive flounder on the southern coast of Korea.

Effects of Use of the Iodine Contrast Medium on Gamma Camera Imaging (요오드 조영제 사용이 감마카메라 영상에 미치는 영향)

  • Pyo, Sung-Jae;Cho, Yun-Ho;Choi, Jae-Ho
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.557-564
    • /
    • 2016
  • Effects of Gamma camera imaging on gamma ray counting rates as a function of use and density of the iodine contrast medium currently in primary use for clinics, and changes in gamma ray counting rates as a function of the contrast medium status upon attenuation correction using a CT absorption coefficient in an SPECT/CT attenuation correction will be considered herein. For experimental materials used $^{99m}TcO_4$ 370 MBq and Pamiray 370 mg, Iomeron 350 mg, Visipaque 320 mg, Bonorex 300 mg of iodine contrast medium. For image acquisition, planar imaging was consecutively filmed for 1, 2, 3, 4, 5 min, respectively, 30 min after administration of $^{99m}TcO_4$. while 60 views were filmed per frame for 20 min at 55 min for the SPECT/CT imaging. In planar imaging, the gamma ray counting rates as a function of filming time were reduced showing a statistically significant difference when mixed according to the type of contrast medium density rather than when the radioactive isotope $^{99m}TcO_4$ and the saline solution were mixed. In the tomography for mixing of the radioactive isotope $^{99m}TcO_4$ and saline solution, the mean counting rate without correction by the CT absorption coefficient is $182{\pm}26counts$, while the counting rate with correction by the CT absorption coefficient is $531.3{\pm}34counts$. In the tomography for mixing of the radioactive isotope $^{99m}TcO_4$ and the saline solution with the contrast medium, the mean values before attenuation correction by CT absorption coefficient were $166{\pm}29$, $158.3{\pm}17$, $154{\pm}36$, and $150{\pm}33counts$ depending on the densities of the contrast medium, while the mean values after attenuation correction were $515{\pm}03$, $503{\pm}10$, $496{\pm}31$, and $488.7{\pm}33counts$, showing significant differences in both cases when comparatively evaluated with the imaging for no mixing of the contrast medium. Iodine contrast medium affects the rate of gamma ray. Therefore, You should always be preceded before another test on the day of dignosis.

An Experimental Study on Bacterial Adhesion onto Activated Carbon and Ceramic (활성탄 및 세라믹 재질에의 세균 부착성에 대한 연구)

  • Kwon Sung-Hyun;Cho Dae-Chul;Rhee In-Hyoung
    • Journal of Environmental Science International
    • /
    • v.14 no.12
    • /
    • pp.1163-1170
    • /
    • 2005
  • The microbial adsorption characteristics of two different media for biological treatment were studied using attached diverse microbes onto activated carbon and ceramic. The results in the experiments of the characteristics of physical adhesion on two different media with addition of high and low concentrated substrate in the culture were observed that the efficient of adhesion onto F-400 activated carbon was higher over that of ceramic due to the surface area of media. The irradiation treatment by ultrasonication with 400 W power and 3 min retention time on the media without addition substrate conditions and subsequent mixing throughly the culture showed the highest efficiency of cell detachment on the media. Three different microbes, P. ovalis, A calcoaceticus, and B. subtillis were used for the study of the characteristics of microbial adhesion on the media. p ovalis showed the highest adhesion capability while B. subtillis showed the lowest capability adhesion onto media either addition of substrate in the culture. The mixed bacterial culture showed $10\%$ lower removal efficiency of DOC in the low concentrated substrate culture compared to the single pure culture. Whileas, it did not show significant difference between two cultures at high concentrated substrate. It was also observed same population density of microorganism by counting of microbes adhered to microbial media with an ultrasound treatment.

Comparative Study on the Effectiveness of Modified Kato's Cellophane Thick Smear and Stoll's Dilution Egg Counting Technique for Quantitative Fecal Examination of Helminth Eggs (윤충란 정량검사를 위한 Stoll 희석충란계산법과 Kato 후층도말변법의 비교)

  • 홍성종;우호춘
    • Parasites, Hosts and Diseases
    • /
    • v.30 no.2
    • /
    • pp.141-146
    • /
    • 1992
  • A total of 197 fecal specimens was prepared for quantitative examination of helminth eggs by modified Kato's cellophane thick smear (M.C.T.S.) and Stoll's dilution egg counting technique (D.E,C.T.). The comparative effectiveness of two techniques was evaluated and conversion function was deduced. The average time required for the microscopic examination on one slide by M.C.T.S. was 12.6 minutes and that of D.E.C.T. was 14.6 minutes. M.C.T.S. showed lower false negative rate than D.E.C.T in light worm burden cases. Functions to convert the counts obtained by M.C.T.S. to E.P.G. by Stoll's dilution egg counting technique were $47.86{\times}10^{0.87{\;}logM.C.T.S.},{\;}$ in A. lumbricoides, $41.69{\times}10^{0.82{\;}logM.C.T.S.}$ in T. trichiura and $63.10{\times}10^{0.85{\;}logM.C.T.S.}$ in C. sinensis. It was suggested M.C.T.S. be better than D.E.C.T. for the quantitative examination of intestinal helminthiases such as A. lumbricoides, T. trichiura, and C. sinensis infections even in the cases with low worm burden.

  • PDF

An Efficient BC Approach to Compute Fractal Dimension of Coastlines (개선된 BC법과 해안선의 프랙탈 차원 계산)

  • So, Hye-Rim;So, Gun-Baek;Jin, Gang-Gyoo
    • Journal of Navigation and Port Research
    • /
    • v.40 no.4
    • /
    • pp.207-212
    • /
    • 2016
  • The box-counting(BC) method is one of the most commonly used methods for fractal dimension calculation of binary images in the fields of Engineering, Science, Medical Science, Geology, etc due to its simplicity and reliability. It deals with only square images with each size equal to the power of 2 to prevent it from discarding unused pixels for images of arbitrary size. In this paper, we presents a more efficient BC method based on the original one, which is applicable to images of arbitrary size. The proposed approach allows the number of the counting boxes to be real to improve the estimation accuracy. The mean absolute error performance is computed on two deterministic fractal images whose theoretical dimensions are well known to compare with those of the existing BC method and triangular BC method. The experimental results show that the proposed method can outperform the two methods and assess the complexity of coastline images of Korea and Chodo island taken from the Google map.