• Title/Summary/Keyword: cost ceiling

Search Result 65, Processing Time 0.034 seconds

A Study on Economic Analysis and Performance Appraisal of Compact Type Variable Air Volume (컴팩트형 VAV 공조기의 성능평가와 경제성 분석에 관한 연구)

  • Kim, Dong-Cheol;Chung, Kwang-Seop;Kim, Young Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.1
    • /
    • pp.44-49
    • /
    • 2015
  • Ceiling cooling and heating system that consider load arrangement and space in the ceiling needs to be developed. Therefore, experimental and economic changes were done to verify the performance of compact type VAV. The test results were as follow. 1) Noise test result, measuring approximately 50.4 dB~56.6 dB (before ceiling in landfill), had a better ceiling deadline than the current measure, about a 10 dB noise reduction, so that the office baseline (40~50 dB) noise was judged to be less than test. 2) For the static pressure test result, taking out an outside hydrostatic 25 mmAq, 24.8 mmAq was measured, respectively, at the point. 3) For the life-cycle cost analysis result, the initial investment cost, maintenance replacement costs, and maintenance costs increased 0.2%, but the energy savings ratio was 19.5% while the whole life cycle savings of 40 years LCC was reduced 11.9%.

Sliding Ceiling Panel Structure (미닫이 천정판 구조)

  • Gook, Seung-Uk
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1478-1485
    • /
    • 2011
  • Subway stations have a characteristic that the facilities in the ceiling should be checked, replaced or expanded frequently. The frequent opening and closing of ceiling panels result in the damage of panels which makes them easily disengaged. In order to resolve this issue, which is giving difficulty in the maintenance of the stations, this study suggest a sliding ceiling panel structure which can be opened and closed with sliding mechanism, instead of current fixed type ceiling panels. The sliding ceiling panel will prevent the damage of ceiling panels due to frequent disengagement and engagement. It will increase the durability of ceiling panel and extend the cycle of panel replacement. Accordingly, the maintenance cost will be also reduced.

  • PDF

Joint installation of ceiling facilities in the subway system (지하철 천장시설물 공동설치 방안)

  • Lee, Pil-Sin
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1953-1959
    • /
    • 2011
  • Subway stations have a characteristic that the facilities in the ceiling should be checked, replaced and expanded frequently. The new installation of supports (steel anchors) for new facilities and workers moving-around in the ceiling result in the damage in the ceiling finish material and concrete structure which also result in construction cost increase. In addition, the noise, vibration and dust generated during the work harm the station environment. There are civil complaints on these which give difficulty to ceiling works. Accordingly, this study suggests a ceiling frame construction method that considers the convenience, economy and efficiency of ceiling work by improving the support installation method for facilities in ceiling.

  • PDF

Deriving Critical Management Factors based on Case Studies of Multi-trade MEP Ceiling Rack Prefabrication (복합공종 MEP 천정 선조립 공법 사례조사를 통한 단계별 중점관리사항 도출)

  • Lee, Dongmin;Jang, Sejun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.76-77
    • /
    • 2015
  • In construction industry, management of construction factors such as cost, schedule, quality and safety is the most important key for delivering successful projects. According to the Smart Market Report, a magazine specialized in construction industry, recently said 'Off-site Prefabrication' is a significant trend related with construction productivity in global construction industry. It is a kind of practice shift from On-site to Off-site. A lot of general contractors in oversea have been using 'Multi-trade MEP Ceiling Rack Prefabrication' method for getting benefits such as decreased cost & schedule and increased labor productivity. Thus, in this paper, critical management factors at each phase from design to installation was derived by researching case studies. Forwardly, it can be a basic guideline for applying Multi-trade MEP Ceiling Rack Prefabrication in Korea construction industry.

  • PDF

A Study on the Application of Gypsum Board through the Application of Fire Resistance Ceiling Structure (내화천장구조 적용을 통한 석고보드 활용 확대에 관한 연구)

  • Choi, Dong-ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.217-218
    • /
    • 2019
  • Fire resistance ceiling system is the structure of which the ceiling installed under the slave of the structure has the fire resistance performance. Because of having the fire resistance performance, fire resistive coatings on steel beams can be reduced and large span structures can be constructed. So, it have advantages of convenience for construction, shorten for construction time and cost reducing. In foreign country, it is general that one system consisting of slave and ceiling is constructed as a fire resistance system, in these cases, gypsum boards are mostly used as ceiling materials. The purpose of this study was to explain the possibility of expanding the use of gypsum boards by securing fire resistance performance of these ceilings.

  • PDF

Design of Working Process for Ceiling Glass Installation Robot (천장유리 설치로봇의 자동화 공정설계)

  • Yoo, Bo-Hyun;Lee, Seung-Yeol;Gil, Myeong-Su;Lee, Sang-Heon;Lee, Kye-Young;Han, Chang-Soo
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.837-842
    • /
    • 2007
  • Since construction materials have been towards larger and heavier, the rate of accident associated with installation works of heavy construction materials is increasing. Installation works of heavy construction materials lead to frequent accidents, increasing the WMSDs(Work-Related Musculo-Skeletal Disorders) in construction site. In case of installation work of heavy glass ceiling, the rate of accidents such as falling and collision is increasing as well. This paper describes a ergonomic design of working platform(deck) in a glass ceiling installation robot. As well as, a design of working process is considered to accomplish an efficient installation work. As a result of the design, an installation work of heavy glass ceiling by the robot will be expected safety assurance and retrenchment of the construction cost and period.

  • PDF

Factors Affecting the Burden of Medical Costs for Inpatients (입원환자 의료비 부담에 영향을 미치는 요인)

  • Kwon, Lee-Seung;An, Byeung-Ki
    • The Korean Journal of Health Service Management
    • /
    • v.6 no.4
    • /
    • pp.143-152
    • /
    • 2012
  • This study analyzes Korea health panel data (2008) (beta version 1.2) of Korea Institute for Health and Social Affairs, and National Health Insurance Corporation to figure out determinants of healthcare expenditure. In result of Multiple Logistic Analysis, in-patents felt burden on the medical expenditure were 70.0%. As to the patients' payment of medical expenditure, patients over 65 years old had 4.765 times higher than those under 14 years, disabled patients 2.778 than non-disabled patients, chronic patients 1.632 times than non-chronic patients, patients belonging to 12 million won ~ 46 million won and under 12 million won in family income had 1.680 times and 2.168 times respectively than patients with over 46 million won, patients in professional recuperation facility 1.546 times than patients in hospital, patients in private medical institutions 1.700 times than patients in national and public medical institutions, patients using upper grade rooms 1.701 times than patients in non-upper grade rooms. As a health care safety net mechanism to protect people from medical expenditure burden, there is the patients' payment ceiling in the National Health Insurance System. Thus, in order to facilitate the patient's payment ceiling, it is required that the level of ceiling is to be specified according to the income level, and self-payment items is to be included.

A Case Study on the Effect of Price Ceiling Regulation on the New Apartment Price (분양가상한제 적용여부에 따른 아파트 분양가 비교분석 -부산광역시 민간택지 사례를 중심으로-)

  • Ryu, Je-Moon;Shim, Jae-Heon;Lee, Sung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3747-3756
    • /
    • 2012
  • This paper examines the effect of price ceiling regulation on the new apartment price. The analysis procedure of the study is divided into two parts, which stand for a case study on the effect of price control on the new apartment price and the survey of real estate experts on price ceiling regulation. The empirical results of our case study show that the selling price under price ceiling regulation is generally lower than that in the situation of price deregulation, in terms of the land development expense and construction cost. With regard to the survey results, more than half of respondents have opinions that price ceiling regulation has an impact on the new apartment price and lowers the price. They are equally divided pro and con regarding the problem of keeping or discarding the regulation.

An Experimental Study on Fire Resistance Performance Test of Non-loadbearing Ceiling Systems (비내력 천장구조 내화성능평가에 대한 실험적 연구)

  • Choi, Dong-Ho;Kim, Dae-Hoi;Park, Soo-Young
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.22-27
    • /
    • 2011
  • Fire resistance ceiling system is the structure of which the ceiling installed under the slave of the structure has the fire resistance performance. Because of having the fire resistance performance, fire resistive coatings on steel beams can be reduced and large span structures can be constructed. So, it have advantages of convenience for construction, shorten for construction time and cost reducing. In foreign country, it is general that one system consisting of slave and ceiling is constructed as a fire resistance system. But in Korea, there are no fire resistance ceiling systems thus economical efficiency due to being high-rise and light-weight of structures is not secured. Therefore research and development of nominal fire resistance ceiling systems is necessary. On this study, fire resistances of standard non-loadbearing ceiling systems were assessed and basic informations for developing the fire resistance non-loadbearing ceiling systems were presented.

A Study of the Development of a Modular, Lightweight Steel Ceiling System (유닛형 경량철골 천정시스템 개발에 관한 연구)

  • Kim, Hyeyeon;Bae, Sanghwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.5
    • /
    • pp.269-277
    • /
    • 2017
  • This study consists of an analysis of pre-existing ceiling construction systems as well as the development of a replacement unitary, lightweight steel ceiling system and related legal standards. Based on the material conditions and progression of the study, appropriate components were chosen and details were modified by mock-up test. A final study model was evaluated for performance and adaptability based on four parameters (indoor environment, constructability, budget economy, and aesthetics) and compared to the pre-existing ceiling system. As a result of the initial study, a lightweight steel design was created consisting of a reinforced structure with modular bars and entry holes for components. This system was hung directly on the suspension structure. The new design increased lighting and acoustic performance adapted to an indoor environment. Moreover, the speed of construction was increased by approximately 30%, the cost was decreased by approximately 20%, and ceiling aesthetics were improved.