• 제목/요약/키워드: corrosion-inhibition

검색결과 189건 처리시간 0.024초

A State-of-the-Art Review of Graphene-Based Corrosion Resistant Coatings for Metal Protection

  • Zade, Ganesh S.;Patil, Kiran D.
    • Corrosion Science and Technology
    • /
    • 제21권5호
    • /
    • pp.390-411
    • /
    • 2022
  • Any design engineer or coating formulator's primary objective is to protect metals. Large investments in terms of money, time, labour, and other resources are necessary for constructing large-scale machinery and structures. In terms of economy, the structure's lifespan should be as long as feasible to create revenue. It is becoming essential to protect metal substrates from corrosion to prolong the lifespan of such huge structures. One of the most exciting, durable, useful, and effective methods to protect metals from corrosion is the application of corrosion-resistant coating. Graphene is a novel material with a wide range of applications because of its extraordinary features. The use of graphene in coating creates an obstacle and complicates the path for corrosive medium to reach the metal. As the path to the metal elongates, the corrosion medium takes longer to reach the metal. Thus, metal corrosion can be avoided. In this paper, the importance of graphene in coating formulation is discussed, including chemical modifications of graphene, the effect of graphene concentration on corrosion inhibition, and the contact angle of coating. This review also highlights the significance of water-based corrosion-resistant coating for preventing environmental damage.

Azadirachta Indica엑스와 요드화이온이 산성매체에서 Al 부식방지에 대한 Synergistic 효과 (Synergistic Effect of Azadirachta Indica Extract and Iodide Ions on the Corrosion Inhibition of Aluminium in Acid Media)

  • Arab, S.T.;Al-Turkustani, A.M.;Al-Dhahiri, R.H.
    • 대한화학회지
    • /
    • 제52권3호
    • /
    • pp.281-294
    • /
    • 2008
  • Potintiodynamic 분광작용과 임피던스 기술을 이용하여 요드화 이온으로 Azadirachta Indica 엑스가 존재하는 0.5 M HCI용액 속의 Al 에 대한 부식 방지 작용을 상승시켰다. 이는 0.5 M HCI 용액에서 AZI 엑스가 Al의 부식을 방지함을 발견하였다. AZI 엑스 농도가 24% v/v이전에는 농도가 커짐에 따라 방지효율도 따라서 커진다. 하지만 AZI 엑스 농도가 더 커지면 Inh. %는 오히려 작아진다. 요드화 이온의 증가는 방지효율을 상당한 양으로 강화시킨다. 요드화 이온이 혼합적으로 존재할 때 Inh. %값은 증가한다. 이는 낮은 AZI 엑스 농도에서 AZI 엑스는 joint adsorption을 통하여 insoluble complex을 형성한다. 하지만 높은 AZI 엑스 농도에서는 요드화 이온과 형성한 complex사이에 competitive adsorption이 나타나 낮은 Inh. %를 초래한다. At all studied요드화 이온의 농도에서 요드화 이온과 AZI 엑스가 동시에 존재할 때의 Inh. %값은 AZI 엑스만 존재할 때보다 감소된다. Synergism parameter Sq는 표면 Coverage 값으로 계산된다. 이 Parameter는 AZI 엑스경우 unity 보다 더 큼을 알 수 있다. 이는 요드화 이온의 증가로 인하여 방지효율이 강화 되였음을 제시한다.

A Study on Drag Reduction Agency for Gas Pipeline

  • Zhang Qibin;Fan Yunpeng;Lin Zhu;Zhang Li;Xu Cuizhu;Han Wenli
    • Corrosion Science and Technology
    • /
    • 제7권5호
    • /
    • pp.283-287
    • /
    • 2008
  • The drag reduction agency (DRA) for gas pipeline, a novel method used for reducing friction or drag on a gas flowing to increase the transmission efficiency of gas pipeline, is a more flexible and economical technology than internal flow efficient coatings. In this paper, an effective DRA has been developed in Authors' Institute by analyzing the hydrodynamic friction resistance on internal gas pipeline and then studying the work mechanism and molecular structure of DRA. In the meantime, a group of property test for selecting DRA material has been determined, including viscosity, contact angle, volatility, corrosion, slab extending, and flow behavior in horizontal tube. The inhibition efficiency and drag reduction efficiency of the developed DRA have been investigated finally based on the relevant test methods. Results of corrosion test show that the developed DRA has very good inhibition effect on mild steel by brushing a thin layer of DRA on steel specimens, giving inhibition efficiency of 91.2% and 73.1% in 3%NaCl solution and standard salt fog environment respectively. Results of drag-reducing test also show that the Colebrook formula could be used to calculate friction factors on internal pipes with DRA as the Reynolds number is in the range of $0.75\times10^5\sim2.0\times10^5$. By comparing with normal industrial pipes, the friction resistance coefficient of the steel pipe with DRA on internal wall decreases by 13% and the gas flux increases by 7.3% in testing condition with Reynolds number of $2.0\times10^5$.

0.25M 황산 용액 상에서의 Imatinib Mesylate에 의한 연강철 부식 억제 (Inhibition of Mild Steel Corrosion in 0.25 M Sulphuric Acid Solution by Imatinib Mesylate)

  • Mohana, K.N.;Shivakumar, S.S.;Badiea, A.M.
    • 대한화학회지
    • /
    • 제55권3호
    • /
    • pp.364-372
    • /
    • 2011
  • 다양한 억제제의 농도, 온도, 유속에서 중량 분석과 변전위 분극법을 이용하여 0.25 M 황산 용액상에 있는 연강철에 대한 imatinib mesylate (IMT)의 부식 억제를 연구하였다. 억제제의 농도가 증가함에 따라 억제 효과가 증가한다는 결과를 얻었다. 연강철 표면 위의 흡착 과정은 Langmuir 흡착 등온선을 따른다. 얻어진 흡착 깁스 자유 에너지의 값은 연강철 위의 IMT의 흡착 과정이 화학흡착이라는 것을 보여준다. 열역학 변수들이 계산되고, 논의되었다. IMT의 HOMO와 LUMO의 전자궤도 밀도 분포는 억제 메커니즘을 논의하는데 이용되었다. FT-IR 분광학과 SEM 이미지는 필름에 흡착된 표면을 분석하기 위해 사용되었다.

배급수 계통에서 부식억제제 적용에 따른 부식과 적수와의 상관관계 (Correlation between Corrosion Rate and Red Water on Application of Corrosion Inhibitor in Drinking Water Distribution System)

  • 우달식;구성은;이병두;김주환;문광순
    • 상하수도학회지
    • /
    • 제19권1호
    • /
    • pp.68-77
    • /
    • 2005
  • This study was performed to evaluate the application of corrosion inhibitor and to examine the correlation between corrosion rate and red water in a series of batch tests and a test using auto corrosion monitoring system at A water treatment plant in Gyeonggido. The corrosion study in the auto corrosion monitoring system indicated that Fe concentration decreased by 30~50% and corrosion rate also reduced remarkably with corrosion inhibitor at $1.8mg\;PO_4/L$. After addition of corrosion inhibitor, it was indicated the effective adsorption of the inhibitor on the surface of the pipe line forming a protective film. The corrosion rate increases with the increase in Fe concentration. With $1.8mg\;PO_4/L$ of corrosion inhibitor, the corrosion rate decreased remarkably. Fe concentration had correlation to not only red water problems but also the corrosion rate that actually dissolved into the water, primarily due to the deposition of oxidized iron or other compounds as a scale, which serves as a large reservoir of corrosion by-product. Therefore, corrosion rate can be estimated by Fe concentration. For these reasons, an effective corrosion inhibitor is also an effective red water control reagent. The effect of the corrosion inhibition can last for some time even the application the corrosion inhibitor is discontinued. For the cost effective and efficient corrosion control, the concentration and timing of corrosion inhibitor addition must be determined properly.

Corrosion Protection from Inhibitors and Inhibitor Combinations Delivered by Synthetic Ion Exchange Compound Pigments in Organic Coatings

  • Chrisanti, S.;Ralston, K.A.;Buchheit, R.G.
    • Corrosion Science and Technology
    • /
    • 제7권4호
    • /
    • pp.212-218
    • /
    • 2008
  • Inorganic ion exchange compounds (IECs) including hydrotalcites and bentonite clays are a well known classes of layered mixed metal hydroxides or silicates that demonstrate ion exchange properties. These compounds have a range of applications from water purification to catalyst supports. The use of synthetic versions of these compounds as environmentally friendly additives to paints for storage and release of inhibitors is a new and emerging application. In this paper, the general concept of storage and release of inhibiting ions from IEC-based particulate pigments added to organic coatings is presented. The unique aspects of the IEC structure and the ion exchange phenomenon that form the basis of the storage and release characteristic are illustrated in two examples comprising an anion exchanging hydrotalcite compound and a cation exchanging bentonite compound. Examples of the levels of corrosion protection imparted by use of these types of pigments in organic coatings applied to aluminum alloy substrates is shown. How corrosion inhibition translates to corrosion protection during accelerated exposure testing by organic coatings containing these compounds is also presented.

기화성방청제 Dialkylamine (di-)nitrobenzoates 합성 및 방청성능 (Synthesis and Performance of Dialkylamine (di-)nitrobenzoates for Vapor Corrosion Inhibitor)

  • 전용진;박용성;소순영
    • 공업화학
    • /
    • 제10권1호
    • /
    • pp.6-11
    • /
    • 1999
  • 방청제로 dialkylaminc (di-)nitrobenzoates 14개 화합물을 합성하고 첨가제 효과와 함께 방청성능을 조사하였다. 합성화합물은 원소분석, FT-IR, $^1H$-NMR 분석으로 확인하였으며, 합성한 화합물과 첨가제 [$(NH_4)_2CO_3$, $NaHCO_3$]의 방청성능은 방청제를 1 M $Na_2SO_4$ 용액에 1% (w/v) 용해시켜 potentiostatic method로 분극실험하여 조사하였다. 철에 대해 dialkylamine 3, 5-dinitrobenzoates보다 dialkylamine 4-nitrobenzoates 부동태화 전류밀도 ($i_p$)가 작았으며, diethylamine 4-nitrobenzoate 용액에서 낮은 값 ($i_p$; $4.78mA/cm^2$)을 나타내었다. 비철에 대한 $i_p$값은 dialkylamine 3, 5-dinitrobenzoates가 작았고 dipropylamine 3, 5-dinitrobenzoate와 hexamethyleneimine 3, 5-dinitrobenzoate가 낮은 값 ($i_p$; 36, $37mA/cm^2$)을 나타냈다. 방청제에 $(NH_4)_2CO_3$$NaHCO_3$ 첨가효과는 철에 대해 높은 부식억제 효과를 나타냈으나, 비철에서는 좋은 결과를 얻지 못하였다. 철용 방청제 diethylamine 4-nitrobenzoate와 $(NH_4)_2CO_3$, $NaHCO_3$의 최적 혼합비율은 4 : 6과 5 : 5이며, 부동태화 전류밀도 ($i_p$)는 0.26, $0.85mA/cm^2$의 최소값을 각각 나타내었다.

  • PDF