Corrosion Behavior of Cr-bearing Corrosion Resistant Rebar in Concrete with Chloride Ion Content

  • Tae, Sung Ho
    • Architectural research
    • /
    • 제7권1호
    • /
    • pp.49-54
    • /
    • 2005
  • Conventional studies have focused on the reduction in the water-cement ratio, the use of various admixtures, etc., to ensure the durability of reinforced concrete structures against such deterioration factors as carbonation and chloride attack. However, improvement in the concrete quality alone is not considered sufficient or realistic for meeting the recent demand for a service life of over 100 years. This study intends to improve the durability of reinforced concrete structures by improvement in the reinforcing steel, which has remained untouched due to cost problems, through subtle adjustment of the steel components to keep the cost low. As a fundamental study on the performance of Cr-bearing rebars in steel reinforced concrete structures exposed to corrosive environments, The test specimens were made by installing 8 types of rebars in concretes with a chloride ion content of 0.3, 0.6, 1.2, 2.4 and $24kg/m^3$. Corrosion accelerated curing were then conducted with them. The corrosion resistance of Cr-bearing rebars was examined by measuring crack widths, half-cell potential, corrosion area and weight loss after 155 cycles of corrosion-accelerating curing. The results of the study showed that the corrosion resistance increased as the Cr content increased regardless of the content of chloride ions, and that the Cr-bearing rebars with a Cr content of 5% and 9% showed high corrosion resistance in concretes with a chloride ion content of 1.2 and $2.4kg/m^3$, respectively.

염화물 오염 콘크리트 공극 용액에서 철근의 부식 억제에 대한 혼합 억제제의 효과 (Effect of Mixed Inhibitor on Corrosion Inhibition of Steel Rebar in Chloride Contaminated Concrete Pore Solution)

  • 소우멘 만달;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.32-33
    • /
    • 2021
  • The corrosion of the embedded steel rebars and the consequent deterioration of the reinforced concrete structure has become a challenging concern to the construction industries for the fiscal deficit. However, corrosion inhibitors are potential and being widely used for corrosion mitigation to solve such problems. This study has been focused on the mixed type of corrosion inhibitor where one component of the corrosion inhibitor is organic and another one is inorganic material. 0.1 (M) triethanolamine (TEA) and 0.01 (M) sodium hexametaphosphate (SHMP) have been mixed in distilled water to produce the mixed inhibitor. Studies of the steel rebar corrosion in chloride contaminated (3.5 wt.% NaCl) concrete pore (CCCP) solution has been conducted using different concentrations of corrosion inhibitor. Electrochemical impedance spectroscopy (EIS) method is involved to understand the corrosion behaviour of the steel rebars at different exposure durations.

  • PDF

FRP Rebar의 부착거동 해석 (Analytical study on the Bond Behavior of FRP Rebar in Concrete)

  • 유영준;박영환;박지선;유영찬;김형열;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.636-639
    • /
    • 2004
  • Reinforced concrete structures have been used for a long time. However, corrosion problem in reinforcing steel is inevitable, which results in the degradation of performance and the shortening of the life of structures. To overcome such problems, FRP(Fiber Reinforced Polymer) rebars have been developed. Due to their corrosion resistance and their superior mechanical properties, FRP rebars are increasingly applied to concrete structures in other countries. To obtain the composite action between FRP rebars and concrete, sufficient bond between two materials must be secured. But, the behavior of FRP rebars is different from that of steel rebars. Therefore, it is necessary to understand and develop the proper bond mechanism of FRP rebars to use them in concrete structures. This paper presents analytical results to investigate the bond-slip relationship between FRP rebars and concrete based on pull out tests.

  • PDF

Corrosion Resistance of Cr-Bearing Rebar to Macrocell Corrosion Environment Induced by Localized Carbonation

  • Tae, Sung-Ho
    • International Journal of Concrete Structures and Materials
    • /
    • 제18권1E호
    • /
    • pp.17-22
    • /
    • 2006
  • Artificial cracks were made in the cover concrete of specimens embedding ten types of steel rebars of different Cr contents. The research aims for developing Cr-bearing steel rebars resistant to macrocell corrosion environments induced by cracking in cover concrete. The cracks were subjected to intensive penetration of carbon dioxide (carbonation specimens) to form macrocells. The carbonation specimens were then treated with accelerated corrosion curing, during which current macrocell corrosion density was measured. The corrosion area and loss from corrosion were also measured at the end of 105 cycles of this accelerated curing. The results of the study showed that Cr-bearing steel with Cr content of 5% or more suppressed corrosion in a macrocell corrosion environment induced by the differences in the pH values due to carbonation of cracked parts. Cr-bearing steels with Cr content of 7% or more are proven to possess excellent corrosion resistance.

콘크리트 기공 솔루션에서의 열간 압연 및 열 기계 처리 철근의 부식 특성 (Corrosion Characteristics of hot rolled and thermo-mechanically treated steel rebar in concrete pore solution)

  • 이한승;싱 지텐드라 쿠마르
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.202-203
    • /
    • 2018
  • Chemistry and microstructure of steel reinforcement bars play an important role to control the corrosion in concrete environments. In present study, we have chosen two different microstructure of steel rebars produced from companies and assessed their corrosion characteristics in simulated concrete pore (SCP) solution with prolonged exposure periods. Hot rolled steel rebar showed more corrosion resistance compare to thermo-mechanically treated (TMT) one. The growth of passive is greater in hot rolled (A) than TMT (B) due to orientation of microstructure. TMT steel rebar exhibit distorted microstructure with many micro cells which enhances the galvanic coupling and induce the deterioration while on the other hand hot rolled rebars exhibit fine grain boundary which responsible in growth of uniform, adherent and protective passive film resultant improved impedance was observed.

  • PDF

Experimental and numerical studies on the cyclic behavior of R/C hollow bridge piers with corroded rebars

  • Cardone, D.;Perrone, G.;Sofia, S.
    • Earthquakes and Structures
    • /
    • 제4권1호
    • /
    • pp.41-62
    • /
    • 2013
  • A comprehensive experimental program of cyclic tests on 1:3-scale models of bridge piers is going to be carried out at the Laboratory of Structures and Materials of the University of Basilicata. The testing models include eight RC single shaft piers with hollow circular cross section. Four piers have been realised using corroded steel rebars. In this paper, the results of preliminary numerical simulation analyses of the cyclic behaviour of the piers, carried out with Opensees using fiber-based models, are presented. Pull-out and lap-splice effects of steel rebars have been taken into account in the numerical analyses. First, the experimental specimens and the test set up are presented. Next, the results of the numerical analyses are discussed. In the numerical analyses, different configurations and levels of corrosion have been considered. The effective stiffness and equivalent damping of the piers is reported as a function of pier ductility and pier drift.

콘크리트 보강용 하이브리드 FRP 리바의 특성 (The properties of hybrid FRP rebar for concrete structures)

  • 원종필;박찬기;황금식;윤종환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.255-260
    • /
    • 2003
  • The corrosion of steel rebars has been the major cause of the reinforced concrete deterioration. It is FRP rebar that is developed to solve problem of such steel rebar. FRP rebar in concrete structures should be used as a substitute of steel rebars for that cases in which aggressive environment produce high steel corrosion, or lightweight is an important design factor, or transportation cost increase significantly with the weight of the materials. But FRP rebar have only linearly elastic behavior; whereas, steel rebar has linear elastic behavior up to the yield point followed by large plastic deformation and strain hardening. Thus, the current FRP rebars are not suitable concrete reinforcement where a large amount of plastic deformation prior to collapse in required. The main objective of this study was to develop new type of hybrid FRP rebar. The manufacture of the hybrid FRP rebar was achieved pultrusion, braiding and filament winding techniques. Tensile and interlaminar shear test results of hybrid FRP rebar can provide its excellent tensile strength-strain behavior and interlaminar stress-strain behavior.

  • PDF

Micro-CT 활용 콘크리트 내 철근 부식 정량을 위한 실험적 연구 (Corrosion Quantification of Reinforcing Bar in Concrete Using Micro Computer Tomography)

  • 장인동;이종구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.252-253
    • /
    • 2019
  • Corrosion of rebars in reinforced concrete structures is a major factor that shortens the life of the structure. As corrosion progresses, the adhesion between the concrete tissues and the rebar decreases and the cracks in the concrete due to the expansion of the oxide intensify. Although it is necessary to measure corrosion behavior of rebars inside the concrete to measure degradation of structures due to rebar corrosion, no studies have been conducted to measure corrosion of rebars in In-situ state. In this study, corrosion of rebars in reinforced concrete specimens was attempted to be quantified using micro-computer tomography. Since corrosion of concrete takes several months per 10mm of cover, accelerated corrosion techniques were applied. Accelerated corrosion on the specimen was conducted by applying a 10 V magnetic field to the buried rebar and external electrodes with the specimen submerged in a 10% calcium chloride solution. The experiment found that within two weeks, more than 40% of rebar reduction occurred, and the cracks in the radial cracks occurred through the concrete structure, leading to the transfer of the oxide produced through the cracks to the surface of the specimen.

  • PDF

Improving the concrete quality and controlling corrosion of rebar embedded in concrete via the synthesis of titanium oxide and silica nanoparticles

  • Jundong Wu;Yan Cui
    • Advances in concrete construction
    • /
    • 제15권1호
    • /
    • pp.1-10
    • /
    • 2023
  • Concrete is one of the most widely used structure materials. Concrete is like the motor of the construction industry. The remarkable feature of this Concrete is its cheapness and low energy consumption. Concrete alone does not show resistance against any force but only against compressive forces. Therefore, steel rebar product is used as a reinforcement and increase the strength of Concrete. It can be done by putting rebar in Concrete in different ways. Rebar rusting is one of the crucial symptoms that cause swift destruction in reinforced structures-factors such as moisture in concrete increase the steel corrosion rate. In most cases, it is difficult to compensate for the damage caused by the corrosion of base metals, so preventing corrosion will be much more cost-effective. Coatings made with nanotechnology can protect Concrete against external degradation factors to prevent water and humidity from penetrating the Concrete and prevent rusting and corrosion of the rebar inside. It prevents water penetration and contamination into the Concrete and increases the Concrete's quality and structural efficiency. In this research, silica and titanium dioxide nanoparticle coatings have been used due to their suitable electrical and thermal properties, resistance to oxidation, corrosion, and wear to prevent the corrosion of rebars in Concrete. The results of this method show that these nanoparticles significantly improve the corrosion resistance of rebars.

노후도를 고려한 실크기 원형단면 교각의 내진성능 휨실험 (Seismic-performance Flexural Experiments for Real Scale Piers with Circular Cross-section Considering Aging Effects)

  • 이승건;이수형;이혜린;홍기증
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권6호
    • /
    • pp.131-142
    • /
    • 2021
  • 노후 교각은 내진설계가 적용되지 않아 소성힌지구역에 겹침이음이 대다수 존재한다. 철근부식은 철근 단면적 감소 및 겹침이음부의 거동저하를 유발하여 교각의 내진성능을 저하시킨다. 본 연구에서는 이러한 노후교각의 특성에 따라 철근부식, 겹침이음, 내진설계 및 내진 보강 여부를 고려하여 실험체를 설계 및 제작하고 실험을 통해 그 영향을 조사하였다. 실험결과, 겹침이음 또는 철근부식은 변위연성도를 감소시킨다. 내진설계 상세 또는 강판 내진보강을 적용하면 충분한 변위연성도가 확보됨을 확인하였다. 모든 비내진실험체는 소성힌지구역 내의 횡철근 겹침이음부의 풀림으로 인해 주철근 좌굴과 심부콘크리트 압축파쇄가 발생하였다. 내진설계된 실험체는 철근부식에 의한 소성힌지구역 내 횡철근의 단면감소와 갈고리 풀림에 의해 주철근 좌굴 및 심부콘크리트 압축파쇄가 발생하였다.