3.5% NaCl 수용액 중에서의 금속과 GECM의 갈바닉 부식에 미치는 면적비의 영향 (Effect of Area Ratio on Galvanic Corrosion Between Metallic Materials and GECM in 3.5% NaCl Solution)

  • 김영식;임현권;손영일;유영란;장현영
    • Corrosion Science and Technology
    • /
    • 제9권1호
    • /
    • pp.39-47
    • /
    • 2010
  • Galvanic coupling between GECM(graphite epoxy composite material) and metallic materials can facilitate corrosion of metals and alloys because GECM is noble and electrically conductive. Galvanic corrosion is affected by many factors including metallic materials, area ratio, surface condition, and corrosivity. This work aims to evaluate the effect of area ratio on galvanic corrosion between GECM and several metals. In the case of glavanic coupling of carbon steel and Al to GECM, corrosion rate increased with increasing area ratio. Corrosion rate of sensitized STS 316S stainless steel decreased a little at an area ratio 1:1 but increased at an area ratio 30:1. It is considered to be due to that area ratio affects galvanic corrosion more in less corrosion resistant alloys. However, in case of STS 316 and Ti, galvanic coupling reduces corrosion rate by the formation of passive film.

표면피복종류에 따른 복합열화환경하의 철근콘크리트 부식특성에 관한 실험적 연구 (An experimental study on corrosion properties of reinforcing steel under environment of complex deterioration)

  • 조봉석;김영덕;윤종기;김재환;김용로;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.86-89
    • /
    • 2003
  • It is recognized that reinforcement corrosion is the main distress behind the present concern regarding concrete durability. In this study, to confirm corrosion of reinforced concrete affected by thickness of cover, kinds of surface coating, measured electric potential, ratio of corrosion area, weight reduction, corrosion velocity of steel bar under environment of complex deterioration. The results showed that an increase in age also increases corrosion of steel bar. Ratio of corrosion area is largely related to ratio of weight reduction. as well, corrosion of steel bar by thickness of cover is superior to l0mm thick than 20mm thick. It showed that an increase in thickness of cover prevent steel bar from deteriorating. The results of this study showed that corrosion velocity was affected by thickness of cover, kinds of surface coating. data on the development of corrosion velocity made with none, organic B, organic A, inorganic B, and inorganic A is shown.

  • PDF

Titanium 전열관을 사용하는 원전 복수기 재료의 Galvanic Corrosion에 미치는 면적의 영향 (Area Effect on Galvanic Corrosion of Condenser Materials with Titanium Tubes in Nuclear Power Plants)

  • Hwang, Seong-Sik;Kim, Joung-Soo;Kim, Uh-Chul
    • Nuclear Engineering and Technology
    • /
    • 제25권4호
    • /
    • pp.507-514
    • /
    • 1993
  • Titanium재료는 해수에서 좋은 내식성을 가지는 이유로 최근 원자력발전소 복수기에 사용되고 있다. 그러나, Ti이 tubesheet재 료인 Cu 합금에 접하고 이것이 water box 재료인 탄소강에 접하게될 경우 접촉금속에 심한 galvanic corrosion이 일어나게 된다. 전기화학적 실험에 의하면, 탄소강이 해수속에서 Ti나 Cu에 접할 때 탄소강의 부식속도는 증가할 것이며, Cu가 Ti에 해수중에서 장기간 접촉할 경우에는 Cu의 부식속도는 증가할 것으로 생각된다, 또한 표면적비, R$_1$(surface area of carbon steel/surface area of Ti).와 R$_2$(surface area of carbon steel/surface area of Cu)가 탄소강의 galvanic corrosion에 매우 중요하며. Water box 재료인 탄소강의 부식속도를 최소화하기 위해서는 이들 표면적비가 낮게 유지되어서는 안될 것이라고 생각된다 침지 galvanic 부식 시험결과 surface area of Fe/surface area of Al Brass값이 1일때 탄소강의 부식속도는 4.4mpy 이었으나 이 비가 $10^{-2}$ 일때는 570mpy이었다. 이렇게 연결된 galvanic시편에 Ti tube를 연결한 경우에는 이 비가 1일때 탄소강의 부식율이 4.4mpy에서 13mpy로 증가하였다. 이는 R$_1$가 R$_2$가 분극곡선에 복합적인 영향을 미치는것으로 설명할 수 있다.

  • PDF

염화물을 함유한 콘크리트 중의 철근방식을 위한 방청제의 효과 (Effect of Corrosion Inhibitor for Reinforcing Steel in Concrete Containing Chlorides)

  • 문한영;김성수
    • 콘크리트학회지
    • /
    • 제10권6호
    • /
    • pp.325-333
    • /
    • 1998
  • 염화물에 의한 콘크리트 중의 철근부식을 억제하기 위하여 콘크리트 배합시 방청제를 사용하는 방안이 일반적으로 많이 사용되고 있으나. 국내에서는 아직까지 방청제의 방식효과에 대한 연구는 찾아보기 어려운 실정이다. 본 연구에서는 염화물의 영향을 받는 콘크리트 중의 철근부식 억제를 위한 방안으로 방청제를 사용하여 철근의 방청효과를 알아보기 위하여 3종류의 방청제와 각각 사용량을 변화시킨 시험체를 제작하여 부식촉진 실험을 실시하였으며, 철근의 자연전위와 부시면적율을 측정하여 방식효과에 대하여 평가하였다. 그 결과 염화물의 혼입량이 지나치게 많을 경우에는 방청제의 양을 증가시켜도 방청효과가 크게 향상되지 않았으나. 염화물의 혼입량을 동일하게 사용하고 방청제의 양을 증가시켜도 방청효과가 크게 향상되지 않았으나, 염화물의 혼입량을 동일하게 방청제의 양을 증가시킬 경우에는 방청효과가 현저하게 좋아짐을 알 수 있었다.

고로슬래그 미분말을 사용한 콘크리트 내의 철근부식에 관한 실험적 연구 (An Experimental Study on the Reinforcement Corrosion in Concrete Using Granulated Blast Furnace Slag)

  • 이동혁;김은겸;김영웅;김영철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.761-766
    • /
    • 2002
  • This paper was peformed to verify the effect that granulated blast furnace slag gets in reinforcement corrosion resistance about chloride ion that invade from outside. An experiment accelerated for the reinforcement corrosion through repeat of brine digestion and dry. Reinforcement corrosion investigated half cell potential method of measurement by ASTM C876 and corrosion area ratio. If granulated blast furnace slag metathesis ratio is high generally that looked the corrosion of reinforcement decreasing as a result that evaluate reinforcement corrosion by ASTM C876 canon in this research. It showed high resistance about reinforcement corrosion that use normal portland cement and increase the metathesis rate of granulated blast furnace slag, as a result that evaluate metathesis rate effect of granulated blast furnace slag according to cement kind. when the test piece split destroying, area rate of reinforcement corrosion showed about result of half cell potential measurement.

  • PDF

불특정 공식손상을 가진 316L 스테인리스강의 기계적 물성치 예측을 위한 다중선형회귀 적용 (Application of Multiple Linear Regression to Predict Mechanical Properties of 316L Stainless Steel with Unspecified Pit Corrosion)

  • 정광후;김성종
    • Corrosion Science and Technology
    • /
    • 제22권1호
    • /
    • pp.55-63
    • /
    • 2023
  • The aim of this study was to propose a multiple linear regression (MLR) equation to predict ultimate tensile strength (UTS) of 316L stainless steel with unspecified pit corrosion. Tensile specimens with pit corrosion were prepared using a potentiostatic acceleration test method. Pit corrosion was characterized by measuring ten factors using a confocal laser microscope. Data were collected from 22 tensile tests. At 85% confidence level, total pit volume, maximum pit depth, mean ratio of surface area, and mean area were significant factors showing linear relationships with UTS. The MLR equation using these three significant factors at a 85% confidence level showed considerable prediction performance for UTS. Determination coefficient (R2) was 0.903 with training and test data sets. The yield strength ratio of 316L stainless steel was found to be around 0.85. All specimens with a pit corrosion presented a yield ratio of approximately 0.85 with R2 of 0.998. Therefore, pit corrosion did not affect the yield ratio.

해양환경하에 방치한 콘크리트중의 철근의 부식 추정에 대한 연구 (A Study on the Estimation of Steel Corrosion in Concrete Exposed under the Environment of Seawater)

  • 문한영;김성수;류재석
    • 콘크리트학회지
    • /
    • 제6권2호
    • /
    • pp.129-137
    • /
    • 1994
  • 해양환경하에 있는 콘크리트 구조물의 열화를 알아보고 철근의 부식 정도를 추정하기 위한 연구내용으로서 콘크리트 중에 철근을 묻은 공시체를 제작하여 간만의 차가 있는 해변에 1년 동안 노출시킨 상태로 시험을 실시 하여 콘크리트 중의 가용성 염분량, 철근의 자연전위값 및 철근의 부식정도에 대하여 고찰하였다. 본 연구 결과 콘크리트 중의 가용성 염분량은 물-시멘트비가 낮을수록, 혼화재를 혼입할 경우 적게 나타났으며 가용성 염분량이 클수록 철근의 부식이 크게 나타났다. 철근 부식의 정도가 심할수록 자연전위값이 감소하였으며 자연전위와 부식면적율과는 상관관계가 있음을 알 수 있었다.

콘크리트 밀실화에 의한 염해대책 및 방청효과에 관한 실험적 연구 (제2보, 철근의 부식 현황을 중심으로) (An Experimental Study on the Effect of Corrosion Protection by Tighting Concrete Used Fly-ash and Silica Fume (Part2, In the case of Steel Bar s Corrosion))

  • 이상수;김진만;남상일;김문한;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 봄 학술발표회 논문집
    • /
    • pp.148-151
    • /
    • 1994
  • Up to now, sea sand without complete removal of salt is being used in the construction works because there is little satisfactory counterplan for the substitute aggregate. In the case that such sea sand is used in the reinforced concrete, the residual salt gives rise to deterioration phenmenon and iron corrosion, reducing durability of the ferro-concrete structures. The paper, an experimental study on the effect of corrosion protection by tighting concrete used SF and FA, is to investigate general steel bar's corrosion and to develop concrete using sea sand economically after it is analyzed and examinated ratio of the corrosion area affected by the autoclave cycle. As a test results, as for corrosion area ratio, it is very effective to use admixrutes such as SF and FA which decrease corrosion area remarkably with increasing the amounts of admixtures. Accordingly the use of admixtures is advantageous for tightening concrete and has an effect of salt damage prevention and rust protection in concrete used sea sand.

  • PDF

해수에 방치한 콘크리트 시험체 중의 철근 부식 추정 (The Estimation of Steel Corrosion in Concrete Specimen Exposed under Seawater)

  • 문한영;김성수;류재석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1993년도 가을 학술발표회 논문집
    • /
    • pp.85-90
    • /
    • 1993
  • This study was performed for the purpose of obtaining the fundamental data to establish the criterion of concrete deterioration and presuming steel corrosion of concrete structures under the environment of seawater. It was exposed in seawater for 1 year that steel was embedded in the concrete specimen. The diffusion coefficients of concrete, corrosion potential and steel corrosion were considered. The results show that corrosion potential is reduced according to steel corrosion and corrosion area ratio is correlative with diffusion coefficients of concrete.

  • PDF

Corrosion effects on tension stiffening behavior of reinforced concrete

  • Shayanfar, M.A.;Ghalehnovi, M.;Safiey, A.
    • Computers and Concrete
    • /
    • 제4권5호
    • /
    • pp.403-424
    • /
    • 2007
  • The investigation of corrosion effects on the tensile behavior of reinforced concrete (RC) members is very important in region prone to high corrosion conditions. In this article, an experimental study concerning corrosion effects on tensile behavior of RC members is presented. For this purpose, a comprehensive experimental program including 58 cylindrical reinforced concrete specimens under various levels of corrosion is conducted. Some of the specimens (44) are located in large tub containing water and salt (5% salt solution); an electrical supplier has been utilized for the accelerated corrosion program. Afterwards, the tensile behavior of the specimens was studied by means of the direct tension tests. For each specimen, the tension stiffening curve is plotted, and their behavior at various load levels is investigated. Average crack spacing, loss of cross-section area due to corrosion, the concrete contribution to the tensile response for different strain levels, and maximum bond stress developed at each corrosion level are studied, and their appropriate relationships are proposed. The main parameters considered in this investigation are: degree of corrosion ($C_w$), reinforcement diameter (d), reinforcement ratio (${\rho}$), clear concrete cover (c), ratio of clear concrete cover to rebar diameter (c/d), and ratio of rebar diameter to reinforcement percentage ($d/{\rho}$).