• 제목/요약/키워드: correlation measurement

검색결과 3,259건 처리시간 0.028초

경락노선상 피부전기 측정기 (EAV, MIR-1) 의 신뢰도 연구 (Reliability of Two Electrodermal Meridian Measurement Systems: EAV and Newly Developed MIR-1)

  • 인창식;허익범;이유정;사공석진;고형균;박영배;이우철
    • 대한한의진단학회지
    • /
    • 제9권1호
    • /
    • pp.125-130
    • /
    • 2005
  • Background and purpose: We evaluated the reliability of two electrodermal measurement devices on meridian skin areas; Electro Acupuncture according to Dr. Voll (EAV) method and newly developed MIR-1. Methods: Eighteen volunteers were tested repeatedly on the same condition with each device. To explore the intra-rater, inter-rater, and test-retest reliabilities, one rater tested each subject twice in succession, then the other rater tested the subject in a row. Finally, retests on the subjects with each device were performed 1 week later. The reliability was determined by Pearson correlation and intraclass correlation statistics. Results: EAV method showed poor reliability, while MIR-1 showed good reliability. Conclusion: It is suggested that further research on the reliability and useful device in both fields of clinical practice and biomedical research.

  • PDF

$^{99m}Tc-DTPA$ 및 Gamma Scintillation Camera를 이용한 사구체 여과율의 측정 (Estimation of Glomerular Filtration Rate Using $^{99m}Tc-DTPA$ and Gamma Scintillation Camera)

  • 최재걸;백세현;이민재;서원혁
    • 대한핵의학회지
    • /
    • 제26권1호
    • /
    • pp.95-100
    • /
    • 1992
  • The radioisotopic measurement of glomerular filtration rate (GFR) has required analysis of serial blood or urine samples over several hours, and does not allow measurement of separate renal function unless separate catherterization of individual ureters is done. Gates described isotopic method for the measurement of global and unilateral GFR based on the determination by scintillation camera of the fraction of the injected dose of $^{99m}Tc-diethylenetriaminepentaacetic$ acid (DTPA) present in the kidneys 2-3 minutes after its administration. We calculated GFR according to Gates' method in 58 adult patients with various levels of global renal function using $^{99m}Tc$ DTPA and validated this technique by correlation with 24 hour creatinine clearance. A good correlation was observed between 24 hour creatinine clearance and GFR calculated by Gates' formula, with an r value of 0.91 (p<0.01). We concluded that determination of GFR according to the Gates' formula allows good and reproducible prediction of GFR with great rapidity and simplicity rendering this technique suitable for clinical practice.

  • PDF

석유정제산업에서의 유기성 유해대기오염물질의 비산배출량 산정 (Estimation of Fugitive Emission of Organic Hazardous Air Pollutants from Oil Refinery Industry)

  • 양성봉;유미선;이영준;유은진;최성헌
    • 한국대기환경학회지
    • /
    • 제24권2호
    • /
    • pp.229-237
    • /
    • 2008
  • Hazardous air pollutants emitted from the oil refinery plant were surveyed from 1993 US and 2005 Korean TRI data. Toluene, xylene, methanol, MTBE and n-hexane, relatively large in amount of fugitive emission, are considered as candidates of newly designated HAPs in Korea. The sealed oil pump, one of equipments among fugitive sources in the crude oil distillation tower was examined for the estimation of amounts of annual HAPs emissions according to several calculation methods using registered emission factors. Emission rates showed to be decreased with following calculation factors; average emission factor>pegged emission factor>concentration emission factor>correlation equation. Annual emission amounts of benzene, toluene, xylene. ethyl benzene and nhexane from the distillation tower were estimated and amounts of these HAPs calculated with TVOC concentrations obtained from LDAR program and correlation equations showed only 6% of those from using concentration factors.

생체 임픽던스 측정에 의한 상지 운동 감지 시스템 (A Human Arm Movement Detection System Using Electrical Bioimpedance Measurement)

  • 김종찬;김수찬;남기창;박민용;김경환;김덕원
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제51권8호
    • /
    • pp.374-379
    • /
    • 2002
  • In this study, we developed a new human arm movement detection system using electrical bio-impedance method with several skin-electrodes. The correlation coefficients of the joint angle and the impedance change from human arm movement was obtained using a goniometer and impedance measurement system developed in this study. The correlation coefficients of the wrist and the elbow movements were 0.94 and -0.99, respectively. This system was applied to control a robotic arm by converting the measured impedance to joint angle to confirm the validity of the proposed system. In conclusion, we confirmed that this system can control the robotic arm according to arm movement without any limitation of movement. This system showed possibility that upper arm movement could be easily measured by impedance measurement system with a few skin-electrodes.

무릎뼈 높이에 대한 도수측정방법의 신뢰도와 타당도 (Reliability and Validity of the Manual Measurement Method for Patellar Height)

  • 김문환;윤성준;원종혁
    • 한국전문물리치료학회지
    • /
    • 제20권3호
    • /
    • pp.54-61
    • /
    • 2013
  • This study was to determine the reliability and validity of manual measurements of patellar height to standard radiographic measurements in 30 knees of 15 subjects. Patellar height was measured using manual and radiographic methods. The manual measurements were performed by two examiners using digital vernier calipers with the subject sitting and the knees in $30^{\circ}$ of flexion. The radiographic measurements were performed in the same position. The reliability of the manual measurements was assessed by means of intraclass correlation coefficients [ICC(3,1)], and the validity was investigated using the Pearson's product-moment correlation coefficient and an independent t-test. The intra- and inter-rater reliabilities of the manual measurement of patellar height were excellent (ICC=.86 and .88 respectively). The validity of patellar height measured manually compared to the radiographic method was good (Pearson's r=.69). In conclusion, the manual method is an objective, qualitative measurement of patella height.

발의 계측과 성인여자구두의 기본치수에 관한 연구 -경상도지역의 여대생을 중심으로- (A study on foot measurement and adult women's shoe standard size.)

  • 김효은
    • 대한가정학회지
    • /
    • 제24권3호
    • /
    • pp.43-50
    • /
    • 1986
  • This study is toidentify what makes people uncomfortable when people wear new shoes and to gain fundamental data for establishing shoe sizes. Data materal from the 16 measurement investigation conducted on 796 college girl students shows the following. 1) More than 96% of the subjects have experienced footache when they wore new shoes. It is significant that 45.76% of the subjects answered shoe width, especially pump-lining part cause them to feel more pain in their feet than any other measurement elements. 2) According to multiple correlation analysis to know which parts of feet determine shoe size, both multiple correlation coefficient of feet length to other parts of foot and joint girth to other parts of foot show the highest of R=0.93. 3) According to the ANOVA-tested result of estimated function when both foot-length-joint girth and foot length-joint girth-foot width are independent variables in each case, the level of α〈0.001 is very significant. 4) The comparision between KS G3116 adult women's shoe size establishment table and my table in this study reveals that the cases of more increased joint girth measurements than standard joint girth measurements in KS G 3116 table are easy to find.

  • PDF

설문과 비침습적 검사를 통하여 심혈관계 건강 정도를 알려주는 심혈관지수의 개발 (Development of a Cardiovascular Index That Estimates Cardiovascular Health Degree by Survey and Noninvasive Examination)

  • 이종선;정인욱
    • 한국정밀공학회지
    • /
    • 제31권5호
    • /
    • pp.459-466
    • /
    • 2014
  • An index was developed that estimates cardiovascular health degree with easily available physiological information such as survey and noninvasive measurement. The survey score was calculated by utilizing questions related to personal disease history, self-feeling, and management state. The measurement score was calculated using physiological parameters such as blood pressure, accelerated plethysmograph(APG), and heart rate variability(HRV), and augmentation index(AI). In order to evaluate effectiveness of the cardiovascular index and modify weighting factors used in each item, a clinical trial was done in a general hospital. The cardiovascular index showed a clear correlation of 0.685 with the doctor's score on the cardiovascular health degree. The correlation between the self-estimated score and doctor's score was as low as 0.217. The large gap between these two scores demonstrated necessity of more objective tools like the cardiovascular index. The cardiovascular score showed a significant difference between normal persons and patients suffering hypertension or diabetes. (p=0.000).

A New Method for Unconstrained Pulse Arrival Time (PAT) Measurement on a Chair

  • Kim Ko-Keun;Chee Young-Joon;Lim Yong-Gyu;Choi Jin-Wook;Park Kwang-Suk
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권3호
    • /
    • pp.83-88
    • /
    • 2006
  • A new method of measuring pulse arrival time (PAT), which is usually used for the estimation of systolic blood pressure, in an unconstrained manner using a chair, is proposed. The capacitive-coupled ECG (CC-ECG) measurement system and the air cushion with balancing tubes system were used for unconstrained PAT measurement. Firstly, the correlation between the standard PAT (S-PAT) from the photoplethysmography (PPG) and the PAT measured in an unconstrained manner (U-PAT) was evaluated. It was observed that U-PAT, which is the time delay from the R-peak of ECG to the steepest decent point of air cushion pressure wave, is significantly correlated with the S-PAT. Secondly, systolic blood pressure (SBP) measured by the radial tonometer is compared to the U-PAT. The ten-beat averaged U-PAT removed respiration effects and demonstrated a high intra-subject correlation with SBP in all participants. Finally, the tonometry SBP was estimated from these U-PAT values for one participant intermittently during half a day.

간호대학생의 대인관계, 자아존중감 및 자기효능감에 관한 연구 (A Study of Correlation among Interpersonal relationship, Self-esteem, and Self-efficacy of Nursing Students)

  • 석소현;신동수;권자연;김귀분
    • 동서간호학연구지
    • /
    • 제11권2호
    • /
    • pp.101-109
    • /
    • 2005
  • Purpose: This study was to examine the correlation among interpersonal relationship, self-esteem, and self-efficacy. Method: Design was descriptive correlative study, and subjects of this study were 353 persons who are students in nursing college. Measures were interpersonal relationship measurement (Cronbach's alpha=.720), self-esteem measurement (Cronbach's alpha=.731), and self-efficacy measurement (Cronbach's alpha=.810). Data were collected from October, 2004 to January, 2005. Data were analyzed with SPSS PC+ on each aim of this study. Result: Findings were as followings. 1. In relationships among interpersonal relationship(1), self-esteem(2), and self-efficacy(3) there were significant positive correlations ((1)(2)r=.526, p=000; (1)(3)r=.443, p=000; (2)(3)r=.556, p=000). 2. In differences of interpersonal relationship, self-esteem, and self-efficacy according to general characteristics there were significant differences in age, grade, satisfaction on credit, satisfied life in the University. Conclusion: Further needs nursing intervention to improve positively the interpersonal relationship that may effect on self-esteem and self-efficacy.

  • PDF

IT컨설팅 서비스 품질 측정에 대한 타당성 검증에 관한 연구 (The Validity of IT Consulting SERVQUAL Measurement Tool)

  • 서현석
    • Journal of Information Technology Applications and Management
    • /
    • 제12권3호
    • /
    • pp.111-128
    • /
    • 2005
  • This paper examines the validity of the newly developed IT consulting SERVQUAL measurement tool. In an attempt to measure Ire IS customers' expectations and perceived quality of the services they received, the researchers developed a diagnostic tool of SERVQUAL based on the solid theoretical background, which can specifically be applied to the IT consulting service sector. This on-going research so far, has been applied to six (6) different organizations that have received IT consulting services over the past years. From the preliminary data collected, the correlation and the factor analyses were conducted to understand the underlying concept and refinement of the measurement tool. Although the correlation analysis showed a little tendency of collinearity among some of the variables, all showed sound relationship of the proposed hypotheses. The exploratory factor analytic approach was chosen because it does not set any priori constraints on the estimation of components or the number of components to be extracted. The number of different factor solutions was extracted and tested to see which solution represents better grouping of the variables. The Crombach's Alpha was computed on different combinations of the factor solutions to ensure validity. The results show 8-dimensional IT consulting SERVQUAL measures which they are, assurance, knowledge & skill, customer relationship, support, empathy, process management, expertise, and education, seem more appropriate than the originally proposed 6 dimensions. The study approach was non-experimental cross-sectional research design. The longitudinal design of follow-up studies to periodically revise and refine current measure is strongly recommended for fine tuning of the tool.

  • PDF