• Title/Summary/Keyword: corrected of axis

Search Result 82, Processing Time 0.025 seconds

The Evaluation of Reliability for Exam Distance of Visual Acuity (시력검사거리에 따른 원거리 시력검사 신뢰성 평가)

  • Chun, Young-Yun;Choi, Hyun-Soo;Park, Seong-Jong;Lee, Seok-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.17-22
    • /
    • 2014
  • Purpose: We aimed to evaluate reliability of eye exam for visual acuity as a function of distance. Methods: There were 39 patients (78 eyes) who had visual acuity 1.0 or more at 5 meters. We measured refractive power of patients at each distances, 5 meters, 4 meters and 3 meters. Automatic chart (LCD-700, Hyeseong Optic. Co., Korea) used for visual acuity, skiascope (Beta 200, Heine, Germany) and auto refractometer (RK-5, Canon, Japan) used as for objective refraction. Accommodation was examined by minus lens addition methods, and Accommodative lag was examined by grid chart for reading distance. Results: Being compared to 3 meter test, Amount of corrected spherical refractive power decreased by $0.10{\pm}0.38$ D, astigmatism decreased by $0.05{\pm}0.10$ D, and axis of astigmatism rotated toward to temporal by $2.64{\pm}18.75$ degrees for right eyes, by $11.43{\pm}48.55$ degrees for left eyes in case of 5 meter test. Changes of corrected refraction and astigmatism were slightly correlated (r=-0.31, r=-0.29). Conclusions: Because corrected refraction power and amount of astigmatism decreased and axis of astigmatism tends to turn the temporal direction according to exam distance, examination distance of visual acuity should improved as to 5 meters.

Comparison of Distal Chevron Osteotomy between with and without Adductor Tenotomy in the Treatment of Hallux Valgus (무지 외반증 환자의 원위 갈매기형 절골술 시 무지 내전건 절단술 병행의 유무에 따른 치료결과 비교)

  • Chu, In-Tak;Park, Hyun-Woo;Kim, Chan-Kyu
    • Journal of Korean Foot and Ankle Society
    • /
    • v.10 no.2
    • /
    • pp.234-237
    • /
    • 2006
  • Purpose: Authors analyzed and compared the treatment result of distal chevron osteotomy between with and without adductor tenotomy. Materials and Methods: 36 patients (60 feet) with a minimum follow-up of one year were involved in this retrospective study. The chevron osteotomy without adductor tenotomy was performed for 20 patients (30 feet) and chevron osteotomy with adductor tenotomy was done for 16 patients (30 feet). The first metatarsophalangeal (MTP) angle and angle between first and second metatarsal longitudinal axis (IM) was measured. The difference of these angles were measured pre-and postoperatively and compared using Student's T-test. Results: In the group of chevron osteotomy with adductor tenotomy, the mean first MTP angle corrected $29^{\circ}$ pre-operatively to $9^{\circ}$ and the mean first IM angle corrected $16^{\circ}$ pre-operatively to $12^{\circ}$. In the group of chevron osteotomy without adductor tenotomy the mean first MTP angle corrected $31^{\circ}$ pre-operatively to $11^{\circ}$ (P>0.05) and the mean first IM angle corrected $13^{\circ}$ pre-operatively to $11^{\circ}$ (P>0.05). Deep peroneal neuroma were found in 3 cases of chevron osteotomy with adductor tenotomy. Conclusions: Adductor tenotomy should be performed in selected patient with chevron osteotomy to prevent deep peroneal neuroma.

  • PDF

Characterization and correction of bemding deformation in pizeoelectric ceramics displacement (길이변조용 압전소자의 휨 측정과 보정)

  • 김재완;남승희;한재원
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.4
    • /
    • pp.300-304
    • /
    • 2001
  • We suggest a method to measure and correct bending deformation in piezoelectric ceramics displacement. The angle and direction of the bending deformation are measured by monitoring the position of a laser beam reflected on a mirror which is attached to the piezoelectric ceramics with the uncertainty of the angle measurement of $0.36\mu$rad. We divided the electrode of a piezoelectric ceramic into 3 parts and connected 3 capacitors to each electrode in order to apply different voltage to each electrode with one voltage supplier. The deformation was corrected by adjusting the capacitance of each capacitor and was reduced to 6.3%, comparing to the uncorrected case. By using this corrected piezoelectric ceramic to modulate the length of the ringdown cavity, the fluctuation of the decay time caused by the change in optic axis of the cavity was removed.emoved.

  • PDF

A STUDY OF THE MANDIBULAR CONDYLE SHAPE ON THE INDIVIDUALIZED CORRECTED TMJ TOMOGRAPH AND SUBMENTOVERTEX RADIOGRAPH (이하두정방사선사진과 개별화 단층방사선사진을 이용한 하악과두의 형태에 관한 연구)

  • 이상래
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.2
    • /
    • pp.227-236
    • /
    • 1994
  • The purpose of this study was to observe mandibular condyle shape in an asymptomatic population. In order to carry out this study, 96 temporomandibular joints in 48 adults(22 males, 26 females), who were asymptomatic for temporomandibular disturbances and had no history of prosthodontic or orthodontic treatments, were selected, and radiographed using the Sectograph(Denar Co., U.S.A.) for lateral and frontal individualized corrected TMJ tomograph and submentovertex radiograph. Mandibular condyles were classified morphologically, and measured medioateral and anteroposterior dimensions and condylar angulation. The obtained results were as follows. 1. In the classification of condyle shape on lateral tomographs, 94.8% were convex type and 5.2% were angled type. 2. In the classification of condyle shape on frontal tomographs, 45.3% were convex type, 32.0% were round type, 16.0% were flat type, and 6.7% were angled type. 3. In the classification of condyle shape on submentovertex radiographs, 34.5% were flat-convex type, 22.9% were flat-flat type, 20.8% were concave-convex type, 19.8% were convex-convex type, and 1.0% were concave-flat type and convex-flat type. Concave-concave type, convex-concave type, and flat-concave type were not observed. 4. The average mediolateral legth of the condyle was 19.3㎜ and the average anteroposterior length was 9.4㎜. The average angle between the long axis of condyle and the coronal plane made on submentovertex view was 19.6 degrees.

  • PDF

Study on The Estimation Method of the Joint for the Operation of the Upper Limb Rehabilitation Equipment for Hemiplegic Patients II (편마비 환자의 상지 재활 기기 운용을 위한 관절 각 추정 기법에 관한 연구 II)

  • Song, K.S.;Eom, S.H.;Lee, E.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.8 no.4
    • /
    • pp.313-318
    • /
    • 2014
  • In this paper, we propose a method for correcting the measurement axis twist that occurs in the process of wearing and each estimation method of joint in which the inertial measurement unit based in health arm by the method of operation upper limb rehabilitation equipment of hemiplegic patients. In order to verify the proposed method, it is fitted with a inertial measurement unit of the upper arm and forearm of the experimenter left arm, verified by comparing actual joint angle is detected by photographing the arbitrary posture, the angle that the estimated joint. Then, it was verified by comparing the applied front / rear techniques for correcting the measurement axis twist. A result of the experiment, before applying the measurement axis twist correction, joint, after but each match rate showed a weak concordance rate in 89.16% and were corrected, measurement axis twist, each concordance rate of joint agreement of 93.28% I understand that it has been 4.12% improvement in the rate.

  • PDF

Optics of the light-weight and foldable telescope based on the Fresnel lens

  • Yu, Hyungjoon;Park, Yong-Sun;Chung, Haeun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.57.3-58
    • /
    • 2016
  • We analyze an optical system of a telescope based on Fresnel type objective lens as suggested by Hyde (1999). The Fresnel objective lens can be thin, light-weight and foldable, and therefore it is possible to develop a space telescope with an aperture larger than that of traditional telescopes. Moreover a lens, whatever it is either Fresnel type or conventional, allows much larger fabrication tolerances. We design a medium-sized telescope adopting Fresnel lens as an objective lens for use in space and possibly on the ground. The well-known chromatic aberration of the Fresnel primary lens is corrected by a field lens and another Fresnel lens using Schupmann method. An additional lens is used for forming images. We analyze the chromatic and off-axis aberrations of the proposed system analytically and suggest methods for the minimization of off-axis aberrations and for the operation in wider spectral range. We also conduct ray tracing and optimize the whole optical system with commercial software. Finally we present the design parameters of a telescope with an aperture of 0.5 to 1 meters, enabling diffraction limited operation for a moderate field of view about 10 arc-minutes.

  • PDF

Signal Compensation for Analog Rotor Position Errors due to Nonideal Sinusoidal Encoder Signals

  • Hwang, Seon-Hwan;Kim, Dong-Youn;Kim, Jang-Mok;Jang, Do-Hyun
    • Journal of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.82-91
    • /
    • 2014
  • This paper proposes a compensation algorithm for the analog rotor position errors caused by nonideal sinusoidal encoder output signals including offset and gain errors. In order to achieve a much higher resolution, position sensors such as resolvers or incremental encoders can be replaced by sinusoidal encoders. In practice, however, the periodic ripples related to the analog rotor position are generated by the offset and gain errors between the sine and cosine output signals of sinusoidal encoders. In this paper, the effects of offset and gain errors are easily analyzed by applying the concept of a rotating coordinate system based on the dq transformation method. The synchronous d-axis signal component is used directly to detect the amplitude of the offset and gain errors for the proposed compensator. As a result, the offset and gain errors can be well corrected by three integrators located on the synchronous d-axis component. In addition, the proposed algorithm does not require any additional hardware and can be easily implemented by a simple integral operation. The effectiveness of the proposed algorithm is verified through several experimental results.

T-joint Laser Welding of Circular and Square Pipes Using the Vision Tracking System (용접선 추적 비전장치를 이용한 원형-사각 파이프의 T형 조인트 레이저용접)

  • Son, Yeong-Il;Park, Gi-Yeong;Lee, Gyeong-Don
    • Laser Solutions
    • /
    • v.12 no.1
    • /
    • pp.19-24
    • /
    • 2009
  • Because of its fast and precise welding performance, laser welding is becoming a new excellent welding method. However, the precise focusing and robust seam tracking are required to apply laser welding to the practical fields. In order to laser weld a type of T joint like a circular pipe on a square pipe, which could be met in the three dimensional structure such as an aluminum space frame, a visual sensor system was developed for automation of focusing and seam tracking. The developed sensor system consists of a digital CCD camera, a structured laser, and a vision processor. It is moved and positioned by a 2-axis motorized stage, which is attached to a 6 axis robot manipulator with a laser welding head. After stripe-type structured laser illuminates a target surface, images are captured through the digital CCD camera. From the image, seam error and defocusing error are calculated using image processing algorithms which includes efficient techniques handling continuously changed image patterns. These errors are corrected by the stage off-line during welding or teaching. Laser welding of a circular pipe on a square pipe was successful with the vision tracking system by reducing the path positioning and de focusing errors due to the robot teaching or a geometrical variation of specimens and jig holding.

  • PDF

A Study on the Relationship between the Disc of Least Confusion and Corrected Vision of Astigmatism (난시안의 최소착락원과 교정시력과의 관계 연구)

  • Kim, Jung-Hee;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.51-57
    • /
    • 2008
  • Purpose: This study has been conducted to know how the size and position of the circle of least confusion has an influence on the vision for minimization of asthenopia when astigmatism is corrected and appropriated prescription to provided clear vision life. Methods: The method of the study has been worked on 68 students (136 eyes) of man and woman enrolled in university of Gyeong-gi-do aged 20 to 40, who have myopic astigmatism in order to know how the corrected vision changes according to the size and position of the circle of least confusion of astigmatism, the vision has been tested by giving the vision whose astigmatic power of 0.25D and 0.50D was just reduced, low correcting the astigmatic power into 0.50D, and at the same time inserting additionally spherical power -0.25D, all under a condition that the corrected vision after completely corrected astigmatism, and the axis of astigmatism was not changed. Results: The average vision was 1.047 when the astigmatic power was fully corrected, and in low correction of 0.25D, it was 0.914, and in low correction of 0.50, it was 0.772. It has been learned that the bigger the circle of least confusion was the bigger the range of vision reduction and the corrected vision in astigmatism has correlation with the size of the circle of least confusion. It has been examined that the average vision according to position of the circle of least confusion in astigmatism was 1.047 when the astigmatic power was completely corrected and focused on the retina with state of point, and in case that the astigmatic power was 0.50D of state of low correction, that is, the circle of least confusion was focused before retina, it was 0.828, and it was also 0.826 when the astigmatic power is low corrected with 0.50D and the circle of least confusion was focused on the retina. Explained briefly, It has been examined that in case that the state of low correction of the astigmatic power was same, the vision reduction was less in the image of the circle of least confusion focused upon the retina than in the image of its being focused before the retina. Conclusions: In case that the refractive power of cylindrical lens is reduced in test of wearability in astigmatism, there needs surely an adjustment of spherical lens that can place the circle of least confusion on the retina.

  • PDF

Three-dimensional accuracy of different correction methods for cast implant bars

  • Kwon, Ji-Yung;Kim, Chang-Whe;Lim, Young-Jun;Kwon, Ho-Beom;Kim, Myung-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.1
    • /
    • pp.39-45
    • /
    • 2014
  • PURPOSE. The aim of the present study was to evaluate the accuracy of three techniques for correction of cast implant bars. MATERIALS AND METHODS. Thirty cast implant bars were fabricated on a metal master model. All cast implant bars were sectioned at 5 mm from the left gold cylinder using a disk of 0.3 mm thickness, and then each group of ten specimens was corrected by gas-air torch soldering, laser welding, and additional casting technique. Three dimensional evaluation including horizontal, vertical, and twisting measurements was based on measurement and comparison of (1) gap distances of the right abutment replica-gold cylinder interface at buccal, distal, lingual side, (2) changes of bar length, and (3) axis angle changes of the right gold cylinders at the step of the post-correction measurements on the three groups with a contact and non-contact coordinate measuring machine. One-way analysis of variance (ANOVA) and paired t-test were performed at the significance level of 5%. RESULTS. Gap distances of the cast implant bars after correction procedure showed no statistically significant difference among groups. Changes in bar length between pre-casting and post-correction measurement were statistically significance among groups. Axis angle changes of the right gold cylinders were not statistically significance among groups. CONCLUSION. There was no statistical significance among three techniques in horizontal, vertical and axial errors. But, gas-air torch soldering technique showed the most consistent and accurate trend in the correction of implant bar error. However, Laser welding technique, showed a large mean and standard deviation in vertical and twisting measurement and might be technique-sensitive method.