• 제목/요약/키워드: correct orbit

검색결과 35건 처리시간 0.019초

인공위성의 위치획득 오차보정을 위한 몬테카를로 분석 (MONTE CARLO ANALYSIS FOR STATION ACQUISITION ERROR CORRECTION OF SATELLITE)

  • 김지영;최규홍
    • Journal of Astronomy and Space Sciences
    • /
    • 제12권2호
    • /
    • pp.265-274
    • /
    • 1995
  • The purpose of perigee kick motor firing is to place a satellite into transfer orbit and that of apogee kick motor firing is to place the satellite into geosynchonous orbit in order to increase the semi-major axis of the transfer orbit and reduce the inclination of the transfer orbit. Because apogee motor firing is always accompanied with injection errors, the satellite is not placed into geosynchonous orbit but into a near-geosynchonous orbit, also knows as a drift orbit. Thus, the orbital maneuver to correct drift orbit into gteosynchonous orbit is required, this maneuver is called the station acquisition. For reduction of expenditure and performance of mission, we estimate $\Delta$V budget and required fuel allowance for station acquisition. As the uncertainty of drift orbit by injection error of perigee and apogee kick motor firing prevents us from obtaining exact $\Delta$V budget, statistical Monte Carlo simulation technique is used in order to get optimal $\Delta$V budget and required fuel allowance with a probability of 99%. With respect to Korea satellite launched by Delta-2 launch vehicle in 1995, Monte Carlo analysis is used in order to get various orbital parameters, $\Delta$V budget and required fuel allowance for station acquisition with a probability of 99%.

  • PDF

안와골파열골절 정복술 후 지속되는 안구함몰 환자에서 정상측 안구의 안구 감압술의 치험례 (Correction of Persistent Enophthalmos after Surgical Repair of Blow Out Fracture Using Orbital Decompression Technique of Contralateral Eye)

  • 이준호;박원용;남현재;김용하
    • 대한두개안면성형외과학회지
    • /
    • 제9권2호
    • /
    • pp.101-104
    • /
    • 2008
  • Purpose: Diplopia and cosmetically unacceptable enophthalmos are the major complications of blow out fracture. Prolapse of orbital tissue into the sinuses, enlarged orbital volume, atrophy of orbital fat and loss of support of orbital walls play a role in the pathogenesis of enophthalmos. To correct post-traumatic enophthalmos, freeing of incarcerated orbital contents combined with reduction of bony orbital volume and reconstruction of suspensory support of globe is necessary. But remained enophthalmos after surgical treatment is difficult to correct completely. In this case, the authors performed implant insertion for affected orbit and endoscopic orbital decompression for unaffected orbit for correction of late enophthalmos. Method: We reviewed a girl patient with right inferomedial orbital wall blow out fracture, right zygoma fracture treated at our hospital for correction of enophthalmos. An 18-year-old female had sustained posttraumatic enopthalmos. Two surgical management was performed for correction blow out fracture at the other hospital. But residual diplopia, enophthalmos, cheek drooping were found. And then she transferred to our hospital. She had severe enophthalmos(5 mm) also had diplopia and extraocular muscle limitation. We performed operation for correction of enophthalmos. After operation, she showed minimal improvement of diplopia and enophthalmos(3 mm). The authors make plan for operation for correction enophthalmos due to cosmetical improvement. Implant insertion was performed for affected orbit. For unaffected orbit, nasoendoscopic medial orbital wall decompression was proceeded. Result: Correction of enophthalmos was found after operation and was maintained for nine years follow-up. Patient expressed satisfaction for the result. Conclusion: To correct persistant enophthalmos, we could have satisfactory result with orbital wall reconstruction on affected eye and decompression on unaffected eye.

A STUDY ON THE EAST/WEST STATION KEEPING PLANNING CONSIDERING WHEEL OFF-LOADING

  • Lee, Sang-Cherl;Park, Bong-Kyu;Kim, Bang-Yeop;Ju, Gwang-Hyeok;Yang, Koon-Ho
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume I
    • /
    • pp.263-266
    • /
    • 2006
  • Now, on the developing COMS(Communication, Ocean and Meteorological Satellite) has solar panel on the South panel only. Therefore, the wheel off-loading has to be performed periodically to reduce a induced momentum energy by a asymmetric solar panel. One of two East/West station keeping maneuver to correct simultaneously longitude and eccentricity, orbit corrections may be performed during one of the two wheel off-loading manoeuvres per day to get enough observation time for meteorological and ocean sensor. In this paper, we applied a linearized orbit maneuver equation to acquire maneuver time and delta-V. Nonlinear simulation for the station keeping is performed and compared with general station keeping strategy for fuel reduction.

  • PDF

Precise Orbit Determination Based on the Unscented Transform for Optical Observations

  • Hwang, Hyewon;Lee, Eunji;Park, Sang-Young
    • Journal of Astronomy and Space Sciences
    • /
    • 제36권4호
    • /
    • pp.249-264
    • /
    • 2019
  • In this study, the precise orbit determination (POD) software is developed for optical observation. To improve the performance of the estimation algorithm, a nonlinear batch filter, based on the unscented transform (UT) that overcomes the disadvantages of the least-squares (LS) batch filter, is utilized. The LS and UT batch filter algorithms are verified through numerical simulation analysis using artificial optical measurements. We use the real optical observation data of a low Earth orbit (LEO) satellite, Cryosat-2, observed from optical wide-field patrol network (OWL-Net), to verify the performance of the POD software developed. The effects of light travel time, annual aberration, and diurnal aberration are considered as error models to correct OWL-Net data. As a result of POD, measurement residual and estimated state vector of the LS batch filter converge to the local minimum when the initial orbit error is large or the initial covariance matrix is smaller than the initial error level. However, UT batch filter converges to the global minimum, irrespective of the initial orbit error and the initial covariance matrix.

Osteoplastic Reconstruction of Post-enucleatic Microorbitalism

  • Yun, Ji Young;Kang, Seok Ju;Kim, Jin Woo;Kim, Young Hwan;Sun, Hook
    • Archives of Plastic Surgery
    • /
    • 제39권4호
    • /
    • pp.333-337
    • /
    • 2012
  • Background Patients who have undergone enucleation during infancy due to retinoblastoma can develop microorbitalism due to the decreased growth stimulation from the eyeball and the surrounding soft tissues. Anatomically, the orbit consist of parts of the frontal bone superiorly, the maxilla inferiorly, the ethmoid bone medially, and the zygoma laterally. Considering the possibility of surgically expanding the orbit using tripod osteotomy, in this study we conducted tripod osteotomy on adult patients with microorbitalism of retinoblastoma. Methods Tripod osteotomy was conducted to expand the orbital volume in adult patients with microorbitalism due to enucleation in infancy for retinoblastoma. The orbital volume was measured using the Aquarius Workstation ver. 4.3.6 and the orbit width was measured with preoperative and postoperative 3-dimensional facial bone computed tomography (CT) imaging. Preoperative and postoperative photographs were used to visualize the difference produced by the surgery. Results The orbital volume of the affected side was 10.3 $cm^3$ before and 12.5 $cm^3$ after the surgery, showing an average increase in volume of 2.2 $cm^3$ (21.4%). The increase in the obital width was confirmed by the preoperative and postoperative 3-dimensional facial CT images and aesthetic improvement was observed by the preoperative and postoperative photographs. Conclusions Tripod osteotomy, which realigns the orbital bone, zygoma, and maxilla, is used to correct posttraumatic malunion as well as non-traumatic congenital abnormalities such as that seen in facial cleft. We applied this procedure in microorbitalism secondary to enucleation for retinoblastoma to allow orbital expansion and correct asymmetry.

Spin-orbit Effects on the Structure of Haloiodomethane Cations CH2XI+ (X=F, Cl, Br, and I)

  • Kim, Hyoseok;Park, Young Choon;Lee, Yoon Sup
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권3호
    • /
    • pp.775-782
    • /
    • 2014
  • The importance of including spin-orbit interactions for the correct description of structures and vibrational frequencies of haloiodomethanes is demonstrated by density functional theory calculations with spin-orbit relativistic effective core potentials (SO-DFT). The vibrational frequencies and the molecular geometries obtained by SO-DFT calculations do not match with the experimental results as well as for other cations without significant relativistic effects. In this sense, the present data can be considered as a guideline in the development of the relativistic quantum chemical methods. The influence of spin-orbit effects on the bending frequency of the cation could well be recognized by comparing the experimental and calculated results for $CH_2BrI$ and $CH_2ClI$ cations. Spin-orbit effects on the geometries and vibrational frequencies of $CH_2XI$ (X=F, Cl, Br, and I) neutral are negligible except that C-I bond lengths of haloiodomethane neutral is slightly increased by the inclusion of spin-orbit effects. The $^2A^{\prime}$ and $^2A^{{\prime}{\prime}}$ states were found in the cations of haloiodomethanes and mix due to the spin-orbit interactions and generate two $^2E_{1/2}$ fine-structure states. The geometries of $CH_2XI^+$ (X=F and Cl) from SO-DFT calculations are roughly in the middle of two cation geometries from DFT calculations since two cation states of $CH_2XI$ (X=F and Cl) from DFT calculations are energetically close enough to mix two cation states. The geometries of $CH_2XI^+$ (X=Br and I) from SO-DFT calculations are close to that of the most stable cation from DFT calculations since two cation states of $CH_2XI$(X=Br and I) from DFT calculations are energetically well separated near the fine-structure state minimum.

궤도섭동을 고려한 저궤도 위성의 추진제 소모량 예측 및 궤도 해석 (The Estimation of Fuel Consumption of Satellites and Orbit Analysis under Orbit Perturbations)

  • 정도희;이상기
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2003년도 제21회 추계학술대회 논문집
    • /
    • pp.65-70
    • /
    • 2003
  • 본 연구에서는 섭동가속도의 변화식으로 주어지는 궤도 섭동 방정식으로부터 지구 편원현상과 대기저항에 의해 기인하는 궤도요소들의 변화를 표현하고 궤도 일회전당 변화량을 근거로 하여 대기저항에 의한 속도 보정과 그에 필요한 연료소모량을 효과적으로 예측하는 방법을 제시하고 그 기법을 다목적위성 궤도해석에 적용하였다. 그리고 궤도 해석을 위해 위성에 영향을 미치는 섭동력을 비대칭 중력장, 대기 저항력, 태양과 달의 인력, 태양 복사압에 의한 영향을 계산하여 정량적으로 비교 분석하였다.

  • PDF

Study on the First On-Orbit Solar Calibration Measurement of Ocean Scanning Multi-spectral Imager (OSMI)

  • Cho, Young-Min
    • Journal of the Optical Society of Korea
    • /
    • 제5권1호
    • /
    • pp.9-15
    • /
    • 2001
  • The ocean Scanning Multi-spectral Imager (OSMI) is a payload on the KOrea Multi-Purpose SATellite (KOMPSAT) to perform worldwide ocean color monitoring f the study of biological oceanography. OSMI performs solar and dark calibrations for on-orbit instrument calibration. The purpose of the solar calibration is to monitor the degradation of imaging performance for each pixel of 6 spectral bands and to correct the degradation effect on OSMI image during the ground station date processing. The design, the operation concept, and the radiometric characteristics of the solar calibration are investigated. A linear model of image response and a solar calibration radiance model are proposed to study the instrument characteristics using the solar calibration data. The performance of spectral responsivity and spatial response uniformity. The first solar calibration data and the analysis results are important references for further study on the on-orbit stability of OSMI response during its lifetime.

휠오프로딩을 고려한 동서 위치유지 기동 계획 연구 (A Study on the East/West Station Keeping Planning Considering Wheel Off-Loading)

  • 이상철;주광혁;김방엽;박봉규;박영웅
    • 한국항공우주학회지
    • /
    • 제34권9호
    • /
    • pp.60-66
    • /
    • 2006
  • 현재 개발 중인 통신해양기상위성은 남쪽면에만 태양전지판이 장착되어 있기 때문에 태양복사압에 의하여 누적되는 모멘텀을 줄이기 위해 휠오포로딩을 정기적으로 수행해야 한다. 일반적으로 정지궤도 위성은 경도와 이심률을 보정하기 위해서 2번의 위치유지 기동을 매 주기마다 수행하는데, 본 논문에서는 기상센서와 해양센서의 충분한 관측시간을 확보하기 위해서 2번의 동서위치보정 기동 중 1번의 기동을 휠오포로딩과 동시에 수행될 수 있다. 선형 궤도기동 방정식을 적용하여 기동시각과 기동크기를 얻었다. 이렇게 구한 기동을 적용하여 수치적분으로 시뮬레이션을 수행하였다. 또한 이를 휠오프로딩과 동시에 수행하지 않는 일반적 방법과 비교 검토 하였다.

A novel technique for placing titanium mesh with porous polyethylene via the endoscopic transnasal approach into the orbit for medial orbital wall fractures

  • Bae, Seong Hwan;Jeong, Dae Kyun;Go, Ju Young;Park, Heeseung;Kim, Joo Hyoung;Lee, Jae Woo;Kang, Taewoo
    • Archives of Plastic Surgery
    • /
    • 제46권5호
    • /
    • pp.421-425
    • /
    • 2019
  • Background The endoscopic transnasal approach is widely used for reconstructing the medial orbital wall by filling it with a silicone sheet or Merocel, but this technique has the disadvantage of retaining the packing for a long time. To overcome this drawback, a method of positioning an absorbable plate in the orbit has been introduced, but there is a risk of defect recurrence after the plate is absorbed. Here, the authors report the results of a novel surgical technique of placing a nonabsorbable titanium mesh with porous polyethylene into the orbit through the endoscopic transnasal approach. Methods Fourteen patients underwent surgery using the endoscopic transnasal approach. Preoperative computed tomography (CT) was used to calculate the size of the bone defect due to the fracture, and the titanium mesh was designed to be shorter than the anteroposterior length of the defect and longer than its height. The titanium mesh was inserted into the orbit under an endoscopic view. The authors then confirmed that the titanium mesh supported the orbital contents by pressing the eyeball and finished the operation. Immediately after surgery, CT results were evaluated. Results Postoperative CT scans confirmed that the titanium mesh was well-inserted and in the correct position. All patients were discharged without any complications. Conclusions We obtained satisfactory results by inserting a titanium mesh with porous polyethylene into the orbit via the transnasal approach endoscopically.