• Title/Summary/Keyword: coronal

Search Result 1,001, Processing Time 0.037 seconds

THE EFFECT OF THE REMOVAL OF CHONDROITIN SULFATE ON BOND STRENGTH OF DENTIN ADHESIVES AND COLLAGEN ARCHITECTURE (비교원성 단백질이 상아질 접착제의 결합강도와 교원질의 형태에 미치는 영향)

  • Kim, Jong-Ryul;Park, Sang-Jin;Choi, Gi-Woon;Choi, Kyoung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.3
    • /
    • pp.211-221
    • /
    • 2010
  • Proteoglycan is highly hydrophilic and negatively charged which enable them attract the water. The objective of study was to investigate the effects of Proteoglycan on microtensile bond strength of dentin adhesives and on architecture of dentin collagen matrix of acid etched dentin by removing the chondroitin sulphate attached on Proteoglycan. A flat dentin surface in mid-coronal portion of tooth was prepared. After acid etching, half of the specimens were immersed in 0.1 U/mL chondroitinase ABC (C-ABC) for 48 h at $37^{\circ}C$, while the other half were stored in distilled water. Specimens were bonded with the dentin adhesive using three different bonding techniques (wet, dry and re-wet) followed by microtensile bond strength test. SEM examination was done with debonded specimen, resin-dentin interface and acid-etched dentin surface with/without C-ABC treatment. For the subgroups using wet-bonding or dry-bonding technique, microtensile bond strength showed no significant difference after C-ABC treatment (p > 0.05). Nevertheless, the subgroup using rewetting technique after air dry in the Single Bond 2 group demonstrated a significant decrease of microtensile bond strength after C-ABC treatment. Collagen architecture is loosely packed and some fibrils are aggregated together and relatively collapsed compared with normal acid-etched wet dentin after C-ABC treatment. Further studies are necessary for the contribution to the collagen architecture of noncollagenous protein under the various clinical situations and several dentin conditioners and are also needed about long-term effect on bond strength of dentin adhesive.

INFLUENCES OF APICOECTOMY AND RETROGRADE CAVITY PREPARATION METHODS ON THE APICAL LEAKAGE (치근단절제 및 역충전와동 형성방법이 치근단누출에 미치는 영향)

  • Yang, Jeong-Ok;Kim, Sung-Kyo;Kwon, Tae-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.2
    • /
    • pp.537-549
    • /
    • 1998
  • The purpose of this study was to evaluate the influence of root resection and retrograde cavity preparation methods on the apical leakage in endodontic surgery. To investigate the effect of various root resection and retrograde cavity preparation methods on the apical leakage, 71 roots of extracted human maxillary anterior teeth and 44 mesiobuccal roots of extracted human maxillary first molars were used. Root canals of the all the specimens were prepared with step-back technique and filled with gutta-percha by lateral condensation method. Three millimeters of each root was resected at a 45 degree angle or perpendicular to the long axis of the tooth according to the groups. Retrograde cavities were prepared with ultrasonic instruments or a slow-speed round bur, and occlusal access cavities were filled with zinc oxide eugenol cement. Three coats of clear nail polish were placed on the lateral and coronal surfaces of the specimens except the apical cut one millimeter. All the specimens were immerged in 2% methylene blue solution for 7 days in an incubator at $37^{\circ}C$. The teeth were dissolved in 14 ml of 35% nitric acid solution and the dye present within the root canal system was returned to solution. The leakage of dye was quantitatively measured via spectrophotometric method. The obtained data were analysed statistically using two-way ANOVA and Duncans Multiple Range Test. The results were as follows: 1. No statistically significant difference was observed between ultrasonic retrograde cavity preparation method and slow-speed round bur technique, without apical bevel (p>0.05). 2. Ultrasonic retrograde preparation method showed significantly less apical leakage than slow-speed round bur technique, with bevel (p<0.0001). 3. No statistically significant difference was found between beveled resected root surface and non-beveled resected root surface, with ultrasonic technique (p>0.05). 4. Non-beveled resected root surface showed significantly less apical leakage than beveled resected root surface, with slow-speed round bur technique (p<0.0001). 5. No statistically significant difference in apical leakage was found between the group of retrograde cavity prepared parallel to the long axis of the tooth and the group of one prepared perpendicular to the long axis of the tooth (p>0.05). 6. Regarding isthmus preparation, ultrasonic retrograde preparation method showed significantly less apical leakage than slow-speed round bur technique, in the mesiobuccal root of maxillary molar, without bevel (p<0.0001).

  • PDF

Pulp Response of Mineral Trioxide Aggregate, Calcium Sulfate or Calcium Hydroxide (Mineral trioxide aggregate, calcium sulfate와 calcium hydroxide의 치수에 대한 반응)

  • Yun, Young-ran;Yang, In-Seok;Hwang, Yun-Chan;Hwang, In-Nam;Choi, Hong-Ran;Yoon, Suk-Ja;Kim, Sun-Hun;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.2
    • /
    • pp.95-101
    • /
    • 2007
  • This study was performed to verify the possibility of MTA and calcium sulfate as a pulp capping agent through comparing the dental pulp response in dogs after capping with MTA, calcium sulfate, and calcium hydroxide. 24 teeth of 2 dogs, 8 month old, were used in this study. Under general anesthesia, cervical cavities were prepared and pulp was exposed with sterilized #2 round bur in a high speed handpiece. MTA calcium hydroxide, and calcium sulfate were applied on the exposed pulp. Then the coronal openin,fs were sealed with IRM and light-cured composite. Two months after treatment, the animals were sacrificed. The extracted teeth were fixed in 10% neutral-buffered formalin solution and were decalcified in formic acid-sodium citrate. They were prepared for histological examination in the usual manner. The sections were stained with haematoxylin and eosin. In MTA group, a hard tissue bridges formation and newly formed odontoblasts layer was observed. There was no sign of pulp inflammatory reaction in pulp tissue. In calcium hydroxide group, there was no odontoblast layer below the dentin bridge. In pulpal tissue, chronic inflammatory reaction with variable intensity and extension occurred in all samples. In calcium sulfate group, newly formed odontoblast layer was observed below the bridge. Mild chronic inflammation with a few neutrophil infiltrations was observed on pulp tissue. These results suggest that MTA is more biocompatible on pulp tissue than calcium hydroxide or calcium sulfate.

Radiographic Evaluation of Stiffness of Articular Eminence in the Temporomandibular Joint(TMJ) of Korean Using Dental cone-beam CT (한국인의 측두하악관절에서 Dental cone-beam CT를 이용한 관절융기의 경사도에 대한 방사선학적 평가)

  • Oh, Sang-Chun;Han, Ji-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.2
    • /
    • pp.163-173
    • /
    • 2013
  • When the mandible performs opening movement, the condyle-disk complex conducts sliding movement along the articular eminence. Thus, anatomic configuration of articular eminence is very important to normal movement of TMJ. The purpose of this study was to measure the posterior slope of the articular eminence and evaluate the effect of a pathologic bone change in the condylar head on the stiffness of articular eminence, and compare the differences of the articular eminence slope by gender and age using dental cone-beam CT. As using i-CAT Cone-Beam Computed Tomography, the CT images of 204 TMJs of 102 patients(43 men and 59 women, mean age: 37.7 years) who were diagnosed at Wonkwang University Sanbon Dental Hospital were evaluated. All images were converted into a TMJ analysis mode to observe the continuous sagittal section images and coronal section images of the joints. To observe and assess bone changes in the condyle, three dentists measured the stiffness of the articular eminence on the same images, and when two of the three dentists agreed on their reading, these results were adopted and recorded. The articular eminence slope, considering the condylar anatomic configuration, was measured in three regions, namely, lateral part, central part, and medial part of the condyle. In the cases of a normal condyle(NCBC) and a condyle(CBC) with bone change, the articular eminence slopes were $57.0^{\circ}$(NCBC) and $51.8^{\circ}$(CBC) at the medial part, $57.9^{\circ}$(NCBC) and $52.4^{\circ}$(CBC) at the central part, and $55.1^{\circ}$(NCBC) and $49.5^{\circ}$(CBC) at the lateral part of the condyle. And the articular eminence slope of the condyle with bone change demonstrated less steepness than that of normal condyle (p<0.05). The articular eminence slope showed mediolaterally that it was the steepest at the central, followed by at the medial, and at the lateral (p<0.05). There were no significant differences by the gender and the age (p.0.05).

CHANGE OF TASTE PREFERENCE AND TASTE BUD AFTER UNILATERAL LINGUAL NERVE TRANSECTION IN RAT (백서 편측 설신경 손상 후 미각 및 설유두의 변화에 대한 연구)

  • Kim, Yoon-Tae;Jeon, Seung-Ho;Yeom, Hak-Ryol;Kang, Jin-Han;Ahn, Kang-Min;Kim, Sung-Min;Jahng, Jeong-Won;Park, Kyung-Pyo;Lee, Jong-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.6
    • /
    • pp.515-525
    • /
    • 2005
  • Purpose of study: Lingual nerve damage can be caused by surgery or trauma such as physical irriatation, radiation, chemotherapy, infection and viral infection. Once nerve damage occurred, patients sometimes complain taste change and loss of taste along with serious disturbance of tongue. The purpose of this study was to evaluate the effects of unilateral lingual nerve transection on taste as well as on the maintenance of taste buds. Materials & Methods: Male Sprague-Dawley rats weighing 220-250g received unilateral transection of lingual nerve, subjected to the preference test for various taste solutions (0.1M NaCl, 0.1M sucrose, 0.01M QHCl, or 0.01M HCl) with two bottle test paradigm at 2, 4, 6, or 8 weeks after the operation. Tongue was fixed with 8% paraformaldehyde. After fixation, they were observed with scanning electron microscope(JSM-$840A^{(R)}$, JEOL, JAPAN) and counted the number of the dorsal surface of the fungiform papilla for changes of fungiform papilla. And, Fungiform papilla were obtained from coronal sections of the anterior tongue(cryosection). After cryosection, immunostaining with $G{\alpha}gust$(I-20)(Santa Cruz Biotechnology, USA), $PLC{\beta}2$(Q-15)(Santa Cruz Biotechnology, USA), and $T_1R_1$(Alpha Diagnostic International, USA) were done. Immunofluorescence of labeled taste bud cells was examined by confocal microscopy(F92-$300^{(R)}$, Olympus, JAPAN). Results: The preference score for salty and sweet tended to be higher in the operated rats with statistical significance, compared to the sham rats. Fungiform papilla counting were decreased after lingual nerve transaction. In 2 weeks, maximum differences occurred. Gustducin and $T_1R_1$ expressions of taste receptor in 2 and 4 weeks were decreased. $PLC{\beta}2$ were not expressed in both experimental and control group. Conclusion: This study demonstrated that the taste recognition for sweet and salty taste changed by week 2 and 4 after unilateral lingual nerve transection. However, regeneration related taste was occurred in the presence of preserving mesoneurial tissue and the time was 6 weeks. Our results demonstrated that unilateral lingual nerve damage caused morphological and numerical change of fungiform papilla. It should be noted in our study that lingual nerve transection resulted in not only morphological and numerical change but also functional change of fungiform papillae.

Evaluation of canal preparation for apical sealing with various Ni-Ti rotary instruments (수 종의 Ni-Ti 회전 기구들을 이용한 치근단 폐쇄 향상을 위한 근관 확대 평가)

  • Shin, Yoo-Seok;Shin, Su-Jung;Song, Min-Ju;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.4
    • /
    • pp.300-305
    • /
    • 2011
  • Objectives: The aim of this study was to evaluate the various NiTi rotary instruments regarding their ability to provide a circular apical preparation. Materials and Methods: 50 single canal roots were selected, cut at the cementodentinal junction and the coronal 1/3 of the canals was flared using Gates Glidden burs. Samples were randomly divided into 5 experimental groups of 10 each. In group I, GT files, Profile 04 and Quantec #9 and #10 files were used. In Group II Lightspeed was used instead of Quantec. In Group III, Orifice shaper, Profile .06 series and Lightspeed were used. In Group IV, Quantec #9 and #10 files were used instead of Lightspeed. In Group V, the GT file and the Profile .04 series were used to prepare the entire canal length. All tooth samples were cut at 1 mm, 3 mm and 5 mm from the apex and were examined under the microscope. Results: Groups II and III (Lightspeed) showed a more circular preparation in the apical 1mm samples than the groups that used Quantec (Group I & IV) or GT files and Profile .04 series.(Group V)(p < 0.05) There was no significant difference statistically among the apical 3, 5 mm samples. In 5 mm samples, most of the samples showed complete circularity and none of them showed irregular shape. Conclusions: Lightspeed showed circular preparation at apical 1 mm more frequently than other instruments used in this study. However only 35% of samples showed circularity even in the Lightspeed Group which were enlarged 3 ISO size from the initial apical binding file (IAF) size. So it must be considered that enlarging 3 ISO size isn't enough to make round preparation.

Effect of moisture on sealing ability of root canal filling with different types of sealer through the glucose penetration model (수종의 실러를 이용한 근관 충전 시 근관 내 수분이 치근단 폐쇄효과에 미치는 영향)

  • Jang, Jin-Ah;Kim, Hee-Lyang;Her, Mi-Ja;Lee, Kwang-Won;Yu, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.5
    • /
    • pp.335-343
    • /
    • 2010
  • Objectives: To compared the effect of different levels of moisture of root canal on the sealing ability after filling with four different types of sealer. Materials and Methods: Single-rooted teeth (n = 90) instrumented to and apical size of 0.06 / 45 were randomly assigned to 12 experimental groups (n = 7 per group), positive/negative control groups (n = 3 per group). The teeth of the experimental groups (a. DRY; b. PAPER POINT DRY; c. WET) were obturated with sealer (Group 1-3: Sealapex; Group 4-6: AH plus; Group 7-9: Tubuli-seal; Group 10-12: EndoRez) and warm vertical compaction method. After 7 days in $37^{\circ}C$, 100% humidity, the coronal-to-apical microleakage was evaluated quantitatively using a glucose leakage model. The leaked glucose concentration was measured with spectrophotometer at 1, 3, 7, 14, 21, and 30 days. Data were recorded ad mmol/L and statistically analysed with the two-way ANOVA and Duncan test (p = 0.05). Results: Throughout the experimental period Tubuli-seal/WET (Group 9) showed the highest mean cumulative glucose penetration (178.75 mmol/L), whereas AH plus/DRY (Group 4) had the least (20.78 mmol/L). Conclusions: The results of this study demonstrated that the moisture condition of root canals at the time of obturation and the type of sealer that was used had a significant effect on leakage and sealing ability. Thus drying procedure according to sealer types is a critical step and should not be missed in endodontic treatment.

A COMPARISON OF THE SHAPING ABILITY OF FOUR ROTARY NICKEL-TITANIUM FILES IN SIMULATED ROOT CANALS (엔진구동형 NiTi 파일의 근관성형효과 비교)

  • Kim, Bo-Hye;Choi, Kyoung-Kyu;Park, Sang-Hyuk;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.2
    • /
    • pp.88-95
    • /
    • 2010
  • The purpose of this study was to compare the root canal shaping ability of 4 rotary NiTi instruments in simulated root canals. For the preparation of thirty two curved root canals, Mtwo instruments using "single length"technique, and Profile, ProTaper Universal, and K3 using crown-down technique (N = 8) were used. All canal samples were prepared by reaching an apical canal size of #30. Pre- and post-instrumentation digital images were recorded and an assessment of canal shape was determined using a computer image analysis program SigmaScan Pro (Systat Software Inc., San Jose, CA, USA). The changes of the dimension of inner walls of canals, (2) the changes of the dimension of outer walls of canals, and (3) the centering ratio were measured at 7 measuring points, and then data were statistically analyzed using one-way ANOVA and Duncan's test. The results were as below; 1. The root canal shaping ability of Profile was significantly faster than that of other rotary NiTi instruments (p < 0.05). 2. The deformation and fracture of all instruments used for this study were not experienced. 3. In the degree of changes of the dimension of inner walls of canals, Profile demonstrated the lowest changes of the dimension of inner walls of canals except at the measuring points of the 1 and 2 mm (p < 0.05). However, the ProTaper Universal showed the highest changes of the dimension of inner walls of canals at all measuring points (p < 0.05). 4. In the degree of changes of the dimension of outer walls of canals, Mtwo demonstrated the lowest changse of the dimension of outer walls of canals except at the measuring point of the 1 mm (p < 0.05). However, Profile exhibited the highest changes of the dimension of outer walls of canals at the measuring points of 3 and 4 mm and ProTaper Universal and K3 showed the largest changes of the dimension of outer walls of canals at the measuring points of 1, 2, 6, and 7 mm (p < 0.05). 5. In degree of centering ratio, Profile demonstrated the least centering ratio comparing with the centering ratio shown by other NiTi instruments at the measuring points of 1, 4, 5, and 6 mm. Results suggest that in the coronal part of canal preparation, active cutting files such as ProTaper Universal may efficiently flare the canal orifice and form a better taper, and in the apical part of the canal, files which have a better centering ability such as Profile may maintain the original canal curvature and reduce the shaping time.

THE BONDING DURABILITY OF RESIN CEMENTS (레진시멘트의 접착 내구성에 관한 연구)

  • Cho, Min-Woo;Park, Sang-Hyuk;Kim, Jong-Ryul;Choi, Kyoung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.343-355
    • /
    • 2007
  • The objectives of this study was to evaluate the durability of 4 resin cements by means of microtensile bond strength test combined with thermocycling method and fractographic FE-SEM analysis. Experimental groups were prepared according to thermocycling (0, 1,000, 5,000) and the kind of resin cements, those were Variolink II, Multilink, Panavia F 2.0, Rely X Unicem. Flat dentin surfaces were created on mid-coronal dentin of extracted third molars. Then fresh dentin surface was grounded with 320-grit silicon carbide abrasive papers to create uniform smear layers. Indirect composite block (Tescera, Bisco Inc., Schaumburg, IL, USA) was fabricated ($12\;{\times}\;12\;{\times}\;6\;mm^3$). It's surface for bonding to tooth was grounded with silicon carbide abrasive papers from 180- to 600-grit serially, then sandblasted witk $20\;-\;50\;{\mu}m$ alumina oxide. According to each manufacturer's instruction, dentin surface was treated and indirect composite block was luted on it using each resin cement. For Rely X Unicem, dentin surface was not treated. The bonded tooth-resin block were stored in distilled water at $37^{\circ}C$ for 24 hours. After thermocycling, the bonded tooth-resin block was sectioned occluso-gingivally to 1.0 mm thick serial slabs using all Isomet slow-speed saw (Isomet, Buehler Ltd, Lake Bluff, IL, USA). These sectioned slabs were further sectioned to $1.0\;{\times}\;1.0\;mm^2$ composite-dentin beams. The specimens were tested with universal testing machine (EZ-Test, Shimadzu, Japan) at a crosshead speed of 1.0 mm/min with maximum load of 500 N. The data was analyzed using one-way ANOVA and Duncan's multiple comparison test at $p\;{\leq}\;0.05$ level. Within the limited results, we conclude as follows; 1. The bond strength of Variolink II was evaluated the highest among experimental groups and was significantly decreased after 1,000 thermocycling (p < 0.05). 2. The bond strength of Multilink was more affected by thermocycling than the other experimental groups and significantly decreased after 1,000 thermocycling (p < 0.05). 3. Panavia F 2.0 and Rely X Unicem showed the gradually decreased tendency of microtensile bond strength according to thermocycling but there was no significant difference (p > 0.05). 4. Adhesive based-resin cements showed lower bond strength with or without thermocycling than composite based-resin cements. 5. Variolink II & Multilink showed high bond strength and mixed failure, which was occurred with a thin layer of luting resin cement before thermocycling and gradually increased adhesive failure along the dentin surface after thermocycling. The bonding performance of resin cement can be affected by application procedure and chemical composition. Composite based-resin cement showed higher bond strength and durability than adhesive based-resin cement.

Development of Dose Planning System for Brachytherapy with High Dose Rate Using Ir-192 Source (고선량률 강내조사선원을 이용한 근접조사선량계획전산화 개발)

  • Choi Tae Jin;Yei Ji Won;Kim Jin Hee;Kim OK;Lee Ho Joon;Han Hyun Soo
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.283-293
    • /
    • 2002
  • Purpose : A PC based brachytherapy planning system was developed to display dose distributions on simulation images by 2D isodose curve including the dose profiles, dose-volume histogram and 30 dose distributions. Materials and Methods : Brachytherapy dose planning software was developed especially for the Ir-192 source, which had been developed by KAERI as a substitute for the Co-60 source. The dose computation was achieved by searching for a pre-computed dose matrix which was tabulated as a function of radial and axial distance from a source. In the computation process, the effects of the tissue scattering correction factor and anisotropic dose distributions were included. The computed dose distributions were displayed in 2D film image including the profile dose, 3D isodose curves with wire frame forms and dosevolume histogram. Results : The brachytherapy dose plan was initiated by obtaining source positions on the principal plane of the source axis. The dose distributions in tissue were computed on a $200\times200\;(mm^2)$ plane on which the source axis was located at the center of the plane. The point doses along the longitudinal axis of the source were $4.5\~9.0\%$ smaller than those on the radial axis of the plane, due to the anisotropy created by the cylindrical shape of the source. When compared to manual calculation, the point doses showed $1\~5\%$ discrepancies from the benchmarking plan. The 2D dose distributions of different planes were matched to the same administered isodose level in order to analyze the shape of the optimized dose level. The accumulated dose-volume histogram, displayed as a function of the percentage volume of administered minimum dose level, was used to guide the volume analysis. Conclusion : This study evaluated the developed computerized dose planning system of brachytherapy. The dose distribution was displayed on the coronal, sagittal and axial planes with the dose histogram. The accumulated DVH and 3D dose distributions provided by the developed system may be useful tools for dose analysis in comparison with orthogonal dose planning.