• 제목/요약/키워드: coronal

검색결과 997건 처리시간 0.028초

Laser Doppler Flowmetry를 이용한 유리치은이식술 부위의 치은혈류 변화에 관한 연구 (A study on gingival blood flow change of free gingival graft sites using Laser Doppler Flowmetry)

  • 전동영;박병기;염창엽;김세훈;김재덕;김병옥
    • Journal of Periodontal and Implant Science
    • /
    • 제32권2호
    • /
    • pp.291-302
    • /
    • 2002
  • In most of the previous studies, invasive and discrete techniques have been used to monitor the healing process of the gingival graft. However, Laser Doppler Flowmetry(LDF, floLAB(R), Moor Instruments Ltd., England) is a non-invasive technique for measurement of blood flow in the tissue and also allows continuous monitoring. Thus, we tested the usefulness of LDF in monitoring the healing process of free gingival graft at gingival recession. Eleven gingival graft site of 7 patients, including 5 males and 2 females, aged between 21 and 41 years (mean age 28.5) were monitored for the blood flow. The blood flow in gingival graft at coronal site, central site, apical site, mesial site and distal site was measured using LDF. Blood flow was measured at 1- week, 2- week, 3- week and 4- week after gingival graft surgery from 10 a.m. to 2 p.m. Time-course of the healing process was evaluated by statistical analysis using repeated ANOVA and Duncan test. The results were as follows : (1) Blood flow stayed increased for 2 weeks, and then, it was a tendency to decrease. (2) The blood flow at distal site had always higher than mesial site during the measuring periods. (3) The blood flow was high orderly after 1 week ; most coronal site, most apical site, central site. But that was high orderly after 2 week, 3 week, 4 week ; most coronal site, central site, most apical site. In conclusion, LDF was a useful and clinically adaptable method to monitor wound healing process. Our study suggested that it was important to protect surgical site to promote initial wound healing.

상악 소구치 근관치료후 수복방법에 따른 응력 분포의 유한 요소 분석 (FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION ACCORDING TO THE METHOD OF RESTORATION AFTER ROOT CANAL THERAPY)

  • 이정식;이재영;조효선
    • Restorative Dentistry and Endodontics
    • /
    • 제21권1호
    • /
    • pp.339-352
    • /
    • 1996
  • Many dentists have been taken an interest in restoration of severly damaged teeth after endodontic treatment and it is a true that there are lots of studies about it. In these days, although we have used Para-Post, pins, threaded steel post, cast gold post and core, and so on, as a method of restoration frequently, it has been in controversy with the effects of them on the teeth and surrounding periodontal tissue. In this study, we assume that the crown of the upper 1st premolar was severly damaged, and after the root canal therapy, two most common types of restoration were carried out ; 1) coronal-radicular amalgam restoration, 2) after setting up the Para-Post, restore with amalgam core and gold crown. After restoration, in order to present the concentration of stress at internal portion of the tooth and the surrounding periodontal tissue, we doveloped a 2-dimensional finite element model of labiopalatal section, then loaded forces from 2 long perpendicular to the lingual incline of buccal ridge an the middle point, parallel to the long direction axis of tooth at the fossa-were applied. The analyzed results were as follows : 1. Stress of the normal first premolar was concentrated on the most weakest anatomical structure, that is, cervical area, and no stress on the bifurcated area of the canal. 2. Crown restoration after root canal therapy causes large stress concentration on the bifurcated area of the canal. This stress concentration has larger value in case of lateral movement of mandible, and there are decrease in the stress concentration compared with natural tooth. 3. Coronal-radicular amalgam restoration method transports more stress to the tooth structure than restoration using Para-Post. 4. There are more stress concentration around Para-Post in the case of lateral movement, and we have more favo rable result when restored with Para-Post. 5. Generally, stress in the lateral movement is larger than stress in the perpendicular load.

  • PDF

The Change of Adjacent Segment and Sagittal Balance after Thoracolumbar Spine Surgery

  • Kim, Kang-San;Hwang, Hyung-Sik;Jeong, Je-Hoon;Moon, Seung-Myung;Choi, Sun-Kil;Kim, Sung-Min
    • Journal of Korean Neurosurgical Society
    • /
    • 제46권5호
    • /
    • pp.437-442
    • /
    • 2009
  • Objective : To characterize perioperative biomechanical changes after thoracic spine surgery. Methods : Fifty-eight patients underwent spinal instrumented fusions and simple laminectomies on the thoracolumbar spine from April 2003 to October 2008. Patients were allocated to three groups; namely, the laminectomy without fusion group (group I, n = 17), the thoracolumbar fusion group (group II, n = 27), and the thoracic spine fusion group (group III, n = 14). Sagittal (ADS) and coronal (ADC) angles for adjacent segments were measured from two disc spaces above lesions at the upper margins, to two disc spaces below lesions at the lower margins. Sagittal (TLS) and coronal (TLC) angles of the thoracolumbar junction were measured from the lower margin of the 11th thoracic vertebra body to the upper margin of the 2nd lumbar vertebra body on plane radiographs. Adjacent segment disc heights and disc signal changes were determined using simple spinal examinations and by magnetic resonance imaging. Clinical outcome indices were determined using a visual analog scale. Results : The three groups demonstrated statistically significant differences in terms of angle changes by ANOVA (p<0.05). All angles in group I showed significantly smaller angles changes than in groups II and III by Turkey's multiple comparison analysis. Coronal Cobb's angles of the thoracolumbar spine (TLC) were not significantly different in the three groups. Conclusion : Postoperative sagittal balance is expected to change in the adjacent and thoracolumbar areas after thoracic spine fusion. However, its prevalence seems to be higher when the thoracolumbar spine is included in instrumented fusion.

Usefulness of Simple Rod Rotation to Correct Curve of Adolescent Idiopathic Scoliosis

  • Kim, Ji Yong;Song, Kyungchul;Kim, Kyung Hyun;Rim, Dae Cheol;Yoon, Seung Hwan
    • Journal of Korean Neurosurgical Society
    • /
    • 제58권6호
    • /
    • pp.534-538
    • /
    • 2015
  • Objective : To correct apical vertebral rotation for adolescent idiopathic scoliosis (AIS), direct vertebral derotation (DVD) or simple rod rotation (SRR) might be considered. The aim of the present study is to introduce the surgical experiences of AIS by a Korean neurosurgeon and to evaluate the effectiveness of SRR for apical vertebral rotation. Methods : A total of 9 patients (1 male and 8 females) underwent scoliosis surgery by a neurosurgeon of our hospital. The Lenke classifications of the patients were 1 of 1B, 2 of 1C, 1 of 2A, 1 of 2C, 3 of 5C and 1 of 6C. Surgery was done by manner of simple rod rotation on the concave side and in situ coronal bending. Coronal Cobb's angles, vertebral rotation angles and SRS-22 were measured on a plain standing X-ray and CT before and after surgery. Results : The mean follow up period was 25.7 months (range : 5-52). The mean number of screw positioning level was nine (6-12). The mean age was 16.4 years (range : 13-25) at surgery. The mean Risser grade was $3.7{\pm}0.9$. The apical vertebral rotation measured from the CT scans was $25.8{\pm}8.5^{\circ}$ vs. $9.3{\pm}6.7^{\circ}$ (p<0.001) and the Coronal Cobb's angle was $53.7{\pm}10.4^{\circ}$ vs. $15.4{\pm}6.5^{\circ}$ (p<0.001) preoperatively and postoperative, respectively. The SRS-22 improved from 71.9 preoperatively to 90.3 postoperatively. There were no complications related with the operations. Conclusion : SRR with pedicle screw instrumentation could be corrected successfully by axial rotation without complications. SRR might serve as a good option to correct AIS deformed curves of AIS.

Free Hand Insertion Technique of S2 Sacral Alar-Iliac Screws for Spino-Pelvic Fixation : Technical Note, Acadaveric Study

  • Park, Jong-Hwa;Hyun, Seung-Jae;Kim, Ki-Jeong;Jahng, Tae-Ahn
    • Journal of Korean Neurosurgical Society
    • /
    • 제58권6호
    • /
    • pp.578-581
    • /
    • 2015
  • A rigid spino-pelvic fixation to anchor long constructs is crucial to maintain the stability of long fusion in spinal deformity surgery. Besides obtaining immediate stability and proper biomechanical strength of constructs, the S2 alar-iliac (S2AI) screws have some more advantages. Four Korean fresh-frozen human cadavers were procured. Free hand S2AI screw placement is performed using anatomic landmarks. The starting point of the S2AI screw is located at the midpoint between the S1 and S2 foramen and 2 mm medial to the lateral sacral crest. Gearshift was advanced from the desired starting point toward the sacro-iliac joint directing approximately $20^{\circ}$ angulation caudally in sagittal plane and $30^{\circ}$ angulation horizontally in the coronal plane connecting the posterior superior iliac spine (PSIS). We made a S2AI screw trajectory through the cancellous channel using the gearshift. We measured caudal angle in the sagittal plane and horizontal angle in the coronal plane. A total of eight S2AI screws were inserted in four cadavers. All screws inserted into the iliac crest were evaluated by C-arm and naked eye examination by two spine surgeons. Among 8 S2AI screws, all screws were accurately placed (100%). The average caudal angle in the sagittal plane was $17.3{\pm}5.4^{\circ}$. The average horizontal angle in the coronal plane connecting the PSIS was $32.0{\pm}1.8^{\circ}$. The placement of S2AI screws using the free hand technique without any radiographic guidance appears to an acceptable method of insertion without more radiation or time consuming.

The accuracy of a 3D printing surgical guide determined by CBCT and model analysis

  • Ma, Boyoung;Park, Taeseok;Chun, Inkon;Yun, Kwidug
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권4호
    • /
    • pp.279-285
    • /
    • 2018
  • PURPOSE. The aim of this clinical study was to assess the accuracy of the implants placed using a universal digital surgical guide. MATERIALS AND METHODS. Among 17 patients, 28 posterior implants were included in this study. The digital image of the soft tissue acquired from cast scan and hard tissue from CBCT have been superimposed and planned the location, length, diameter of the implant fixture. Then digital surgical guides were created using 3D printer. Each of angle deviations, coronal, apical, depth deviations of planned and actually placed implants were calculated using CBCT scans and casts. To compare implant positioning errors by CBCT scans and plaster casts, data were analyzed with independent samples t-test. RESULTS. The results of the implant positioning errors calculated by CBCT and casts were as follows. The means for CBCT analyses were: angle deviation: $4.74{\pm}2.06^{\circ}$, coronal deviation: $1.37{\pm}0.80mm$, and apical deviation: $1.77{\pm}0.86mm$. The means for cast analyses were: angle deviation: $2.43{\pm}1.13^{\circ}$, coronal deviation: $0.82{\pm}0.44mm$, apical deviation: $1.19{\pm}0.46mm$, and depth deviation: $0.03{\pm}0.65mm$. There were statistically significant differences between the deviations of CBCT scans and cast. CONCLUSION. The model analysis showed lower deviation value comparing the CBCT analysis. The angle and length deviation value of the universal digital guide stent were accepted clinically.

TOWARD NEXT GENERATION SOLAR CORONAGRAPH: DEVELOPMENT OF COMPACT DIAGNOSTIC CORONAGRAPH ON ISS

  • Cho, Kyungsuk;Bong, Suchan;Choi, Seonghwan;Yang, Heesu;Kim, Jihun;Baek, Jihye;Park, Jongyeob;Lim, Eun-Kyung;Kim, Rok-Soon;Kim, Sujin;Kim, Yeon-Han;Park, Young-Deuk;Clarke, S.W.;Davila, J.M.;Gopalswamy, N.;Nakariakov, V.M.;Li, B.;Pinto, R.F.
    • 천문학회보
    • /
    • 제42권2호
    • /
    • pp.66.2-66.2
    • /
    • 2017
  • The Korea Astronomy and Space Science Institute plans to develop a coronagraph in collaboration with National Aeronautics and Space Administrative (NASA) and install it on the International Space Station (ISS). The coronagraph is an externally occulted one stage coronagraph with a field of view from 2.5 to 15 solar radii. The observation wavelength is approximately 400 nm where strong Fraunhofer absorption lines from the photosphere are scattered by coronal electrons. Photometric filter observation around this band enables the estimation of 2D electron temperature and electron velocity distribution in the corona. Together with the high time cadence (< 12 min) of corona images to determine the geometric and kinematic parameters of coronal mass ejections, the coronagraph will yield the spatial distribution of electron density by measuring the polarized brightness. For the purpose of technical demonstration, we intend to observe the total solar eclipse in 2017 August for the filter system and to perform a stratospheric balloon experiment in 2019 for the engineering model of the coronagraph. The coronagraph is planned to be installed on the ISS in 2021 for addressing a number of questions (e.g. coronal heating and solar wind acceleration) that are both fundamental and practically important in the physics of the solar corona and of the heliosphere.

  • PDF

뇌하수체 종양의 방사선 수술 시 영상 융합 프로토콜이 실제 PTV와 OAR 선량에 미치는 영향 (The Dosimetric Effect on Real PTV and OARs at Various Image Fusion Protocol for Pituitary Adenomas)

  • 이경남;이동준;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제21권4호
    • /
    • pp.354-359
    • /
    • 2010
  • 뇌하수체 종양의 치료 계획 시 다양한 영상 융합 프로토콜이 실제 PTV (planning target volume) coverage 및 OAR (organ at risk) 보호에 미치는 선량학적 영향을 확인하고자 하였다. 선량 체적 히스토그램(DVH, dose volume histogram)을 이용하여 각 프로토콜 별 실제 PTV의 coverage 및 그 변화 그리고 시각경로(optic pathway) 및 뇌간(brainstem)의 최대 흡수 선량과 임계 선량을 초과한 체적을 획득하였고 축상면(axial plane)과 관상면(coronal) 영상을 함께 사용하여 S-I (superior-inferior) 방향의 불확정도를 보정한 영상 융합 프로토콜이 축상면 만을 이용한 경우보다 시각경로 및 뇌간의 최대 흡수 선량과 임계 선량을 초과한 체적 모두 감소된 수치를 보임을 확인 하였다. 본 case에 한해 축상면 그리고 관상면 영상을 함께 사용하는 것이 OARs 보호에 가중치를 둔 방사선 수술 치료 계획 수립에 도움을 줄 수 있다.

지대치 유도면의 기울기에 따른 응력 분포에 대한 연구 (A STUDY OF THE STRESS DISTRIBUTION ACCORDING TO THE SLOPES OF THE CHIDING PLANES OF THE ABUTMENTS)

  • 이청희
    • 대한치과보철학회지
    • /
    • 제36권2호
    • /
    • pp.293-301
    • /
    • 1998
  • The purpose of this study was to investigate the effects of load on root that was applied to edentulous area in three simulated situation, in each case the guiding planes of abutment were right vertical, 95 degrees, or 100 degrees to residual ridge. The 2-dimensional finite element method was used and the finite element model was prepared as fellows. Right mandibular 1st and 2nd molar was lost and the 2nd premolar with distal rest was used as primary abutment which had three different degrees of guiding plane. Then 150N of compressive force was applied to central fossae of the 1st and 2nd molars and von Mises stress and displacement was measured. The results were as follows; 1. Irrespective of slopes of guiding planes, the stress was concentrated on mesial side of root apex and distal side of coronal portion of root, in particular on junction with distal alveolar bone. As slopes of guiding planes were increased. stress on root and compact bone surrounding abutment was increased but no considerable effect was seen on compact bone of residual ridge. 2. Distal side of coronal portion of root limited by periodontal ligament was displaced distally and mesial side of apical portion was mesially. With slope of guiding plane increasing, the pattern of displacement was similar with one another but the quantity was increased. 3. Both abutment & alveolar bone were displaced downward and root of abutment, especially distal side of coronal portion, was displaced severely. As the guiding plane was tiffed more mesially over $90^{\circ}$, the degree of displacement was also increased.

  • PDF

Comparison of the Multidetector-row Computed Tomographic Angiography Axial and Coronal Planes' Usefulness for Detecting Thoracodorsal Artery Perforators

  • Kim, Jong Gyu;Lee, Soo Hyang
    • Archives of Plastic Surgery
    • /
    • 제39권4호
    • /
    • pp.354-359
    • /
    • 2012
  • Background During the planning of a thoracodorsal artery perforator (TDAP) free flap, preoperative multidetector-row computed tomographic (MDCT) angiography is valuable for predicting the locations of perforators. However, CT-based perforator mapping of the thoracodorsal artery is not easy because of its small diameter. Thus, we evaluated 1-mm-thick MDCT images in multiple planes to search for reliable perforators accurately. Methods Between July 2010 and October 2011, 19 consecutive patients (13 males, 6 females) who underwent MDCT prior to TDAP free flap operations were enrolled in this study. Patients ranged in age from 10 to 75 years (mean, 39.3 years). MDCT images were acquired at a thickness of 1 mm in the axial, coronal, and sagittal planes. Results The thoracodorsal artery perforators were detected in all 19 cases. The reliable perforators originating from the descending branch were found in 14 cases, of which 6 had transverse branches. The former were well identified in the coronal view, and the latter in the axial view. The location of the most reliable perforators on MDCT images corresponded well with the surgical findings. Conclusions Though MDCT has been widely used in performing the abdominal perforator free flap for detecting reliable perforating vessels, it is not popular in the TDAP free flap. The results of this study suggest that multiple planes of MDCT may increase the probability of detecting the most reliable perforators, along with decreasing the probability of missing available vessels.