• 제목/요약/키워드: corona discharging

검색결과 26건 처리시간 0.026초

코로나 방전에 의한 방진/의료용 마스크 여과재의 기능화 가공 (Functional Finishing of Nonwoven Filter for Dust-proof/Medical Masks by Corona Discharging Treatment)

  • 홍영기
    • 한국염색가공학회지
    • /
    • 제25권3호
    • /
    • pp.232-239
    • /
    • 2013
  • In this study, 25gsm melt-blown polypropylene nonwoven for dust-proof/medical masks was finished by the corona discharging treatment. The influence of corona discharging parameters on the filtration efficiency was investigated. Several parameters such as discharging voltage, discharging speed, distance to discharging wire and configuration of discharging system had an effect on filtration efficiency, while the parameters had no effect on breathing resistance. Optimum corona discharging conditions are as follows: Wires were installed on the upper part of the nonwoven and paper pipe was installed on the lower part of the nonwoven having a distance of 5cm. The sequence of wire voltages was +60 kV, +60 kV, 0, -60 kV, and -60 kV. The discharging voltage and speed were 60 kV and 30m/min respectively. The nonwoven treated by corona discharging at the optimum condition showed a filtration efficiency of 80% or more, which is suitable for dust-proof/medical masks.

다공성 수침-평판전극간의 수적 방출 특성 (Water Droplet Ejection Characteristics of a Wet Porous Point-Plate Airgap)

  • 정재승;이우석;문재덕
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.2005-2010
    • /
    • 2009
  • Water droplet ejection characteristics of a point-to-plate airgap, with a wet porous point as a corona electrode, has been investigated. And the water droplet traces, charge, mass and number were measured experimentally. More particles are observed with wet porous point than metal point because the corona-discharging wet porous point can eject a number of water droplets. The water droplets ejected from the positive-corona-discharging wet porous point showed very fine traces as compared with those from the negative-corona-discharging wet porous point. Moreover, the water droplets ejected from the AC-corona-discharging wet porous point showed granular-like larger traces. It was shown that the weak corona discharge can eject smaller water droplets with larger ratio of mass-to-charge than the intense corona discharge.

코로나방전에 의한 polyethylene terephthalate 필름의 표면처리 (Surface treatment of polyethylene terephthalate films by corona discharge)

  • 김명룡
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제8권3호
    • /
    • pp.316-323
    • /
    • 1995
  • A vital step in magnetic tape manufacturing is the surface modification of polymer substrate prior to ink application. A critical element for good adhesion of magnetic ink on polymeric substrate is the ability to join ink in cost-effective manner. Corona discharging is one of the effective methods of modifying polymer surface to improve adhesion while maintaining the desirable properties of the film itself. Surface treatment by corona which is exposure of film surface to electron or ion bombardment, rather than mere exposure to active species, like atomic oxygen or ozone, can enhance adhesion by removing contaminant, electret, roughening surface, and/or introducing reactive chemical groups. Reactive neutrals, ions, electron and photons generated during the corona treatment interact simultaneously with polymers to alter surface chemical composition, wettability, and thus film adhesion. However, it is highly recommended that extensive chains scission be avoided because it can lead to side-effect by forming sticky matter, resulting in dropouts. This paper reviews principles of surface preparation of polymer substrate by corona discharging. In addition, the experimental section provides a description of parameter optimization on corona discharging treatment and its side-effect. Experimental results are discussed in terms of surface wetting as determined by contact angle measurements.

  • PDF

펄스코로나 방전의 전극길이, 펄스반복율에 따른 부하 임피던스 변화 특성 및 EMTP 해석 (The EMTP Analysis and Characteristics of Load Impedance on Various Electrode length, Pulse Repetition in Pulse Corona Discharging)

  • 정종한;송우정;전진안;정현주;홍정환;김희제
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권4호
    • /
    • pp.158-163
    • /
    • 2002
  • The pulsed Power system has been widely used to many applications, such as E/P(Electrostatic Precipitator), DeNOx/DeSOx power system, often generator, etc. In this paper, we study EMTP analysis and characteristics of critical voltage and load in impedance on various electrode length of pulse corona. To obtain a stable pulse voltage, we designed a compact pulse generator switched MOSFET and tested their characteristics by adjusting electrode length and pulse repetition. As a re sult, critical voltage of pulse corona and load impedance on increasing electrode length were decreased. These results indicate we can control critical voltage of pulse corona and suppress arc discharging between two electrodes.

코로나방전 표면 처리시 이동속도 및 공급전력 변화에 따른 폴리프로필렌 표면 안전성 특성 (Surface Safety Characteristics of Polypropylene Surface Treatment by Variation of Rolling Speed and The Electric Power of Corona Discharge)

  • 이수환;이동훈
    • 한국안전학회지
    • /
    • 제33권1호
    • /
    • pp.41-46
    • /
    • 2018
  • Experiments were carried out the phenomenal observation on effect of corona treated hotmelt laminating film in process of manufacture by 2 kinds of rolling speed and electric power variatons. Surface treatment by corona which is exposure of film surface to electron of ion bombardment, rather than mere exposure to active species, like atomic oxygen or ozone, can enhance adhesion by removing contaminant, electret, roughening surface, and introducing reactive chemical group. Reactive neutrals, ions, electron and photons generated during the corona treatment interact simultaneously with polymers to alter surface chemical composition, wettability, and thus film adhesion. However, it is highly recommended that extensive chains scission is avoided because it can lead to side-effect by forming sticky matter, resulting in dropouts. This paper reviews principles of surface preparation of polypropylene substrate by corona discharging. In addition, the experimental section provides a description of parameter optimization on corona discharging treatment and its side-effect. Experimental results are discussed in terms of surface wetting as determined by contact angle and SEM measurements. When the rolling speed of the film decreased from 1.666 [m / sec] to 0.083 [m / sec], contact angle decreased from $80[^{\circ}]$ to $64[^{\circ}]$, and the wettability was greatly improved. As the supply power increased from 0.4 [kVA] to 2 [kVA] at the corona discharge surface treatment, the contact angle decreased from $77[^{\circ}]$ to $65[^{\circ}]$, and the wettability was greatly improved.

폴리염화비닐(PVC)의 코로나 대전현상에 관한 연구 (A study on the Corona Electrification Phenomena for Polyvinyl chloride (PVC))

  • 박구범;황명환;조기선;이덕출;임헌찬
    • 한국안전학회지
    • /
    • 제7권2호
    • /
    • pp.57-62
    • /
    • 1992
  • In this thesis, the electrification phenomenon was studied by measurement of charging current and discharging current in polymers when the carriers generated by corona discharge were supplied to the surface of polymers. Corona charging current of PVC, polar and noncrystalline polymer, was larger than that of nonpolar and amorphous polymers. Corona charging current on the specimen of naked upper surface (CIM) was larger than charging current on the specimen of electrode made. Carrier injection differed from interfacial phase of polymer surFace. The transfer phenomenon vaned with chemical structure of polymer and then the polar effect of PVC was remarkable because of large electron affinity of Cl. In the characteristics of discharging current of PVC, the abnormal current was observed. It was supposed that this phenomena presented the trap of injected carriers in PVC and that static electricity phenomenon was generated by trap.

  • PDF

조기방전용 접지판의 개발 및 특성 (Development and Its Characterization of Earth Plate for Early Streamer Discharge)

  • 최상원;허용
    • 한국안전학회지
    • /
    • 제29권6호
    • /
    • pp.46-48
    • /
    • 2014
  • This paper compared and demonstrated the performance of the earth plate for conventional type and early streamer discharging type developed a new plate in order to improve the performance of the ground plate for use in grounding. The results obtained are shown below; early streamer discharge earth plate was high 5 kV on DC flashover voltage and corona discharge current was higher than about 2 times under the same test conditions compared to the conventional earth plate. From the experiential result, streamer discharge earth plate had a function of rapid inflow/out flow than the general ground plane because of by corona discharge current to be generated in the sharp serrated in formed the ground plane when strike current occurred. In the future, the newly developed early streamer discharge ground plate would be beneficial for grounding work to be widely used to promote the convenience and economy of construction.

복합절연재료 FRP의 코로나 대전파 전위감쇄특성에 관한 연구 (The Study on Potential Characteristics and Corona Discharge of Composite Insulating Material)

  • 이백수;신태현;김진식;강대하;이덕출
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1995년도 추계학술대회 논문집
    • /
    • pp.365-368
    • /
    • 1995
  • Charge decay, thermally stimulated current (TSC), charging and discharging currents(I) are measured for corona-charged composite insulating materials. In this study, We will make an experiment in charge decay on composite material surface, TSC, polarity effect and the others in order to analysis its mechanism. Especially, Fiber glass Reinforced Plastics(FRP) is the best composite material which has been so far. Therefore, Its worthy of notice to investigate its characteristic. And then some other materials will be focused on. This experiment measured characteristic of charge decay, dependence of discharging-time and other electrostatic characteristics on FRP.

  • PDF

도장설비에서의 정전기 재해 사례 연구 (Case Study on the Electrostatic Hazards in the Coating Mechanical System)

  • 김길태;정영만;이재근
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.602-606
    • /
    • 2006
  • The electrostatic is well known phenomena. The fires and explosions caused by electrostatic occur often in the coating mechanical system. This paper presents various cases of electrostatic hazards, reasons why electrostatic hazards are happened, and methods for preventing electrostatic hazards. Generally the electrostatic can be lead to corona discharging, streaming electrification, and impinging electrification in the coating process. Corona discharging happens at electrostatic spray gun with 70 kV. Streaming electrification occurs at mixing process between paint and thinner, and transportation process with thinner. Impinging electrification is shown when the thinner are sprayed to drums. For the purpose of preventing the electrostatic discharge and damage, conductors should be ground, surface electric potential of should be decreased in using electrostatic shielding and ground, and flow of thinner should be controlled acceptable velocity.

  • PDF

고전압 방전 검출용 자외선 코로나 카메라 개발 및 방전 이미지 분석 (Analysis of Image and Development of UV Corona Camera for High-Voltage Discharge Detection)

  • 김영석;송길목;방선배;김종민;최명일
    • 조명전기설비학회논문지
    • /
    • 제25권9호
    • /
    • pp.69-74
    • /
    • 2011
  • In this paper, the UV corona camera was developed using the solar blind and Multi Channel Plate(MCP) technology for the target localization of UV image. UV camera developed a $6.4[^{\circ}]{\times}4.8[^{\circ}]$ of the field of view as a conventional camera to diagnose a wide range of slightly enlarged, and power equipment to measure the distance between the camera and the distance meter has been attached. UV camera to measure the discharge count and the UV image was developed, compared with a commercial camera, there was no significant difference. In salt spray environments breakdown voltage was lower than the normal state, thereby discharging the image was rapidly growing phenomenon.