• 제목/요약/키워드: corner opening

검색결과 37건 처리시간 0.028초

3D Numerical investigation of a rounded corner square cylinder for supercritical flows

  • Vishwanath, Nivedan;Saravanakumar, Aditya K.;Dwivedi, Kush;Murthy, Kalluri R.C.;Gurugubelli, Pardha S.;Rajasekharan, Sabareesh G.
    • Wind and Structures
    • /
    • 제35권1호
    • /
    • pp.55-66
    • /
    • 2022
  • Tall buildings are often subjected to steady and unsteady forces due to external wind flows. Measurement and mitigation of these forces becomes critical to structural design in engineering applications. Over the last few decades, many approaches such as modification of the external geometry of structures have been investigated to mitigate wind-induced load. One such proven geometric modification involved the rounding of sharp corners. In this work, we systematically analyze the impact of rounded corner radii on the reducing the flow-induced loading on a square cylinder. We perform 3-Dimensional (3D) simulations for high Reynolds number flows (Re=1 × 105) which are more likely to be encountered in practical applications. An Improved Delayed Detached Eddy Simulation (IDDES) method capable of capturing flow accurately at large Reynolds numbers is employed in this study. The IDDES formulation uses a k-ω Shear Stress Transport (SST) model for near-wall modelling that prevents mesh-induced separation of the boundary layer. The effects of these corner modifications are analyzed in terms of the resulting variations in the mean and fluctuating components of the aerodynamic forces compared to a square cylinder with no geometric changes. Plots of the angular distribution of the mean and fluctuating coefficient of pressure along the square cylinder's surface illustrate the effects of corner modifications on the different parts of the cylinder. The windward corner's separation angle was observed to decrease with an increase in radius, resulting in a narrower and longer recirculation region. Furthermore, with an increase in radius, a reduction in the fluctuating lift, mean drag, and fluctuating drag coefficients has been observed.

直4角 揷入物 로 充전된 有限平板 의 應力解析 (Stress Analysis of the Finite Plates with Rectangular Inserts)

  • 조선휘;김기식
    • 대한기계학회논문집
    • /
    • 제6권4호
    • /
    • pp.361-366
    • /
    • 1982
  • This paper attempts to predict the stress concentration around the corner of rectangular inserts of different material of mechanical properties from the base material of the finite rectangular plate. The problem is analyzed through the FEM and photo-elastic experiment with the inclination angle of the insert as variable parameters. According to the experiments and the numerical analysis, the maximum stress concentration occurs at the point of tangential discontinuity of a insert. When the lain insert or opening was so inclined that the distance from the free end of the plate to a corner became minimum, the maximum stress concentration factor was found.

축소 철근콘크리트 벽체의 내력과 균열진전에 대한 개구부모서리 균열제어 띠의 영향 (Effect of Crack Control Strips at Opening Corners on the Strength and Crack Propagation of Downsized Reinforced Concrete Walls)

  • 왕혜린;양근혁
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권4호
    • /
    • pp.40-47
    • /
    • 2022
  • 이 연구의 목적은 철근콘크리트 벽체의 내력, 변형 및 균열진전에 대한 개구부 모서리의 사인장 균열 제어를 위한 다양한 보강방법들이 효율성을 평가하는 것이다. 개구부 모서리의 사인장 균열제어 보강방법으로서 이 연구에서 제안한 균열제어 띠, 기존의 경사보강근 배근방법, 그리고 응력분산곡면판을 선택하였다. 균열제어 띠에서는 균열치유 기능성이 부여된 것도 함께 고려하였다. 개구부 주위의 체적변화 및 균열 폭 진전을 평가하기 위하여 개구부 모서리에서 사인장 균열 유도를 위한 축소 벽체 실험을 수행하였다. 실험결과 균열제어 띠는 경사보강근 및 응력분산곡면판에 비해 개구부 주위의 체적변화 감소 및 개구부 모서리 균열 폭 제어에 효율적이었다. 균열 치유 기능이 포함된 균열제어 띠는 사전 실험에서 발생한 균열들을 치유하면서 축소 벽체의 내력 향상 및 균열 폭 감소에 가장 좋은 성능을 보였다.

피로 균열 형상 진전의 수치 모델링 기법에 관한 연구 (A Numeric Modelling Technique for the Shape Development of Fatigue Crack)

  • 한문식
    • 한국정밀공학회지
    • /
    • 제16권2호통권95호
    • /
    • pp.225-233
    • /
    • 1999
  • This paper describes a versatile finite element technique which has been used to investigate of wide range of structural defects of practical importance. The procedure automatically remeshes the three-dimensional finite element model during the stages of crack growth. Problems analyzed to date include the surface cracks in leak-before-break situations, the development of quarter-elliptical corner defects, planar semi-elliptical surface defects and the fatigue growth of defects.

  • PDF

프리플렉스 부재를 이용한 기존 철근콘크리트 지중박스구조물 우각부에 대한 내진보강공법 사례연구 (A Case Study on Earthquake Resistant Reinforcement Method for the Corner of Existing Underground R.C Box Structures using Pre-flexed Member System)

  • 정지승;김진구;이진혁
    • 한국안전학회지
    • /
    • 제31권3호
    • /
    • pp.68-74
    • /
    • 2016
  • This paper presents a new strengthening method of underground box structures against seismic loads for anti-seismic capacity improvement. A threaded steel member with pressure devices(so called 'Pre-flexed member system') is used to improve seismic capacity of the RC box structure. The pre-flexed member system is fixed the corner of opening after chemical anchor was installed by drilling hole on the box structure. The structural performance was evaluated analytically. Two bracing types of strengthening methods were used; conventional bracing method and I-bracing pressure system. For the performance evaluation, seismic analyses were performed on moment and shear resisting structures with and without strength member system. Numerical results confirmed that the proposed pre-flexed member system can enhance the seismic capacity of the underground RC box structures.

실내공간에서 화재 발생위치에 따른 연기거동에 대한 실험연구 (An Experimental Study of Smoke Movement of the Various Fire Location in Room)

  • 유홍선;정진용;이재하;홍기배
    • 대한기계학회논문집B
    • /
    • 제26권5호
    • /
    • pp.703-709
    • /
    • 2002
  • In order to investigate the smoke movement in three dimensional room fires, the center fire, wall fire and corner fire plume in different sized fires were studied experimentally by rectangular pool fire using methanol as a fuel. As the fire size became larger for the center fires placed at the center of the floor, the air flow rate entrained through the opening, average hot layer temperature, flame angle deflected backwards and mean flame height was observed to increase. On the other hand, as the fire size became smaller, the neutral plane height in the door and time reached steady-state was observed to decrease. The average hot layer temperature, mean flame height and doorway neutral plane height obtained from comer fire were higher than those produced by wall fires and center fires. The simple model for describing the effect of walls on the mean flame height was presented. It was shown that the model provides a good description of the present measurements, when used with the assumption by Hansell(1993), that the increase of the average flame height is equal to the ratio of the open to the total perimeters of the trays. Also the two models for predicting the effects of walls on the mean flame height were presented. These models overestimated the measured values of the mean flame height above fuel trays close to a wall and in a corner by approximately 19-26%, respectively.

Aerodynamic measurements of across-wind loads and responses of tapered super high-rise buildings

  • Deng, Ting;Yu, Xianfeng;Xie, Zhuangning
    • Wind and Structures
    • /
    • 제21권3호
    • /
    • pp.331-352
    • /
    • 2015
  • A series of wind tunnel tests were conducted on tapered super high-rise buildings with a square cross section by applying synchronous pressure measurement technology. The effects of global strategy of chamfered modification on aerodynamic loads and wind-induced responses were investigated. Moreover, local aerodynamic strategies of opening a ventilation slot in the corner of equipment and refuge floors were carried out. Results show that the global strategy of tapered elevation increased the vortex shedding frequency, but reduced vortex shedding energy, leading to reduction of across-wind aerodynamic loads and responses. Chamfered modification suppressed the across-wind vortex shedding effect on tapered buildings. Opening the ventilation slot further suppressed the strength of vortex shedding and reduced the residual energy related to vortex shedding in aerodynamic loads of chamfered buildings. Finally, the optimized locations of local aerodynamic strategies were suggested.

모형시험과 개별요소법을 이용한 단면 형상에 따른 공동 주변 취성파괴에 관한 연구 (A Study on the Stress Induced Brittle Failure around Openings with Cross-sectional Shape by Scaled Model Test and DEM Simulation)

  • 배성호;전석원;박의섭
    • 터널과지하공간
    • /
    • 제17권5호
    • /
    • pp.389-410
    • /
    • 2007
  • 불연속면의 빈도가 높지 않은 견고한 암반의 경우 굴착시 공동 주변 영역에서의 파괴나 변형 특성은 형성되어 있는 초기응력 조건과 강도 특성에 절대적인 영향을 받는다. 과도한 초기응력장은 굴착 공동 주변에 점진적이고 국부적인 취성파괴를 유발시킴으로서 시공의 안정성과 경제성을 확보하는데 장애요인으로 작용할 수 있다. 이 논문에서는 응력 수준과 터널형상에 따른 공동 주변의 취성파괴 거동 특성을 파악하기 위해 축소된 터널 시험체를 이용한 이축압축시험과 입자 결합모델을 이용한 개별요소법의 일종인 $PFC^{2D}$ 해석에 의한 연구를 수행하였다. 실내 이축압축시험을 통해 취성파괴의 발생 영역과 형태 면에서 실제 암반 공동 주변에서 발생된 파괴 특성과 유사한 파괴 거동을 모사할 수 있었다. 모형시험체에 대한 이축압축시험 결과 최소 주응력 방향의 공동 단면 곡선부에서는 균열이 표면에서 개시된 후 내부로 진행되어 국부적인 노치형 파괴영역이 형성되었다. 이에 비해 모서리와 직선부의 경우 공벽 표면과 내부에서 발생된 균열들의 상호 연결, 결합에 의해 대규모의 노치형 분리면이 유도되고 곡선부에 비해 큰 파괴영역이 형성되는 것으로 조사되었다.

A Hydraulic Model Stydy of the Water-Intake Structure near River Mile 37 on the Missouri River

  • Byungman-Yoon
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 1992년도 수공학연구발표회논문집
    • /
    • pp.133-141
    • /
    • 1992
  • A three water-intake structure designed to built along the right bank of the Missouri River near Chesterfield, Missouri was model-tested at an undistorted scale of 1:5. Although the discharge capacity of each of six pumps to be installed is only 21,000 gpm, the model indicated strong flow circuation and unstable free-surface conditions as flow entered the two-pump bay through a narrow sluice opening at an angle. Strong free-surface vartices were also observed in the model. The sump modifications developed in the study included an array of baffle bars, a perforated plate, floor splitters, and floor-corner fillets. The solutions developed in this study could be applied to other pump sumps with multiple pump units.

  • PDF

가압식 브레이싱 보강에 의한 지중박스구조물의 내진성능향상 방법 (Anti-seismic Capacity Improvement of Underground Box Structures Strengthened with Pressure Bracing)

  • 정지승;문인기;민대홍
    • 한국안전학회지
    • /
    • 제28권4호
    • /
    • pp.97-102
    • /
    • 2013
  • This paper presents a new strengthening method of underground box structures against seismic loads for anti-seismic capacity improvement. A threaded steel member with pressure devices(so called 'I-bracing pressure system') is used to improve seismic capacity of the RC box structure. The I-bracing pressure system is fixed the corner of opening after chemical anchor was installed by drilling hole on the box structure. The structural performance was evaluated analytically. Two bracing types of strengthening methods were used; conventional bracing method and improved I-bracing pressure system. For the performance evaluation, seismic analyses were performed on moment and shear resisting structures with and without I-bracing pressure system. Numerical results confirmed that the proposed I-bracing pressure system can enhance the seismic capacity of the underground RC box structures.