• 제목/요약/키워드: core test

검색결과 2,431건 처리시간 0.029초

FRACTURE TOUGHNESS OF VARIOUS CORE MATERIALS

  • Lee Shin-Won;Lee Sun-Hyung;Yang Jae-Ho;Han Jung-Suk;Lee Jai-Bong
    • 대한치과보철학회지
    • /
    • 제39권6호
    • /
    • pp.682-697
    • /
    • 2001
  • This investigation evaluated the fracture toughness($K_{IC}$) of eight currently available core materials, and relate the fracture toughness value to fractography analysis and surface characteristics using a atomic force microscope (AFM). Single-edge notched (SEN) test specimens (n=10) and compact tension (CT) test specimens (n=10) were prepared conforming to the ASTM Standard E-399 for a high copper amalgam, three composite core materials (Core-Max II, Core Paste, Bisfil Core), two reinforced composite core materials (Ti-Core, Ti-Core Natural), a resin-modified glass ionomer core material (Vitremer), and a conventional glass ionomer core material (Ketac-Molar). The specimens were tested with an Instron Universal Testing Machine. The maximum loads were measured to calculate the fracture toughness ($K_{IC}$). Thereafter, fracture surfaces of SEN specimens of each material were investigated for fractography analysis using scanning electron microscope. And, disc-shaped specimens with 1mm thickness were fabricated for each material and were investigated under AFM for surface morphology analysis. The results were as follows: 1. Bisfil Core showed the highest mean fracture toughness regardless of test methods. 2. For the tooth-colored materials, Ti-Core Natural exhibited the highest fracture toughness. 3. Ketac Molar showed a significantly low fracture toughness when compared with the amalgam and the composite resin core materials(p<0.05). 4. The fracture toughness values obtained with the single-edge notched test, except Ketac Molar, were higher than those obtained in the compact tension test. 5. SEM revealed that the fracture surface of high fracture toughness material was rougher than that of low fracture toughness material. 6. AFM revealed that the surface particles of the composite resins were smaller in size, with a lower surface roughness than the glass ionomer core materials.

  • PDF

지지면 조건에 따른 코어근육 강화효과의 비교 (The comparisons of effect of core muscle strengthening by the surface conditions)

  • 김정희;김준호;박병우;김소망;이선욱;김민경;김나율;윤소정;황혜민;김윤정;주선영
    • 대한물리치료과학회지
    • /
    • 제24권1호
    • /
    • pp.1-13
    • /
    • 2017
  • Purpose: The objective of this study was compare the effect of core muscle strengthening between core exercise on stable surface and core exercise on unstable surface. Methods: Thirty-nine adults participated in this study and were randomly allocated to three groups. The stable surface exercise group and unstable surface exercise groups practiced core muscle training for $3{\times}30minute$ sessions over a 4-week period. The control group did not received therapeutic intervention except pre and post test. The following clinical tools were used to assess core muscle strength and balance: Side Plank Test, Trunk Flexion Test, Balance Error Scoring Test, Core Muscle Stength & Stability Test. Results: The stable surface exercise group showed significant improvement in trunk muscle strength of anterolateral part as revealed by the Side Plank Test and Trunk flexion Test(p<.05). The unstable surface exercise group showed significant improvement in trunk muscle strength of anterolateral part and balance ability as revealed by the Balance Error Scoring Test and Core Muscle Strength & Stability Test(p<.05). Conclusion: The results of this study, both core exercise on stable surface and core exercise on unstable surface induced core muscle strengthening and balance ability. Expecially core exercise on unstable surface more effective to core muscle strengthening and balance ability.

  • PDF

멀티코어 SoC의 테스트 시간 감축을 위한 테스트 Wrapper 설계 (A Test Wrapper Design to Reduce Test Time for Multi-Core SoC)

  • 강우진;황선영
    • 한국통신학회논문지
    • /
    • 제39B권1호
    • /
    • pp.1-7
    • /
    • 2014
  • 본 논문은 멀티 코어 SoC의 전체 테스트 시간 감축을 위한 효율적인 테스트 wrapper 설계 방법을 제안한다. 제안된 알고리즘은 잘 알려진 Combine 알고리즘을 사용하여 멀티코어 SoC의 각 코어에 대해 초기 local wrapper해 집합을 구성하고 가장 긴 테스트 시간을 소모하는 코어를 dominant 코어로 선택한다. Dominant 코어의 테스트 시간을 기준으로 다른 코어들에 대해 wrapper 특성인 TAM 와이어 수와 테스트 시간을 조정한다. Design space exploration을 위해 일부 코어들의 TAM 와이어 수를 줄이고 테스트 시간을 증가시킨다. 변경된 wrapper 특성을 기존 local wrapper 해 집합에 추가한다. 코어들의 기존 local wrapper 해 집합이 global wrapper 해 집합으로 확장되어 스케줄러에 의한 멀티코어 SoC의 전체 테스트 시간이 감소한다. 제안된 wrapper의 효과는 ITC'02 벤치마크 회로에 대해 $B^*$-트리 기반의 테스트 스케줄러를 사용하여 검증된다. 실험 결과 기존의 wrapper를 사용하는 경우에 비해 테스트 시간이 평균 4.7% 감소한다.

A Review on the Regionalization Methodology for Core Inlet Flow Distribution Map

  • Lee, Byung-Jin;Jang, Ho-Cheol;Cheong, Jong-Sik;Baik, Se-Jin;Park, Young-Sheop
    • Nuclear Engineering and Technology
    • /
    • 제33권4호
    • /
    • pp.441-456
    • /
    • 2001
  • ABB-CE's regionalization methodology for the core inlet flow distribution map is reviewed. This methodology merges the test data of fuel assembly locations which are either in symmetry or strongly correlated with others. It increases the number of available test data for each regional flow factor It makes up effectively for the deficiency due to limited number of test data. It also contributes to making the core inlet flow distribution smoother not only locally but also over the entire core, and to relieving the impacts of test errors that may happen due to some do- calibrated local pressure measurement taps. As a result, the core inlet How distribution data becomes more statistically useful and thus the conservatism involved in handling the core inlet flow factors for the thermal margin analysis is expected to be reduced. Meanwhile, the regionalized map may lose the unique local characteristics in core inlet flow distribution too much. By an alternative approach introduced in the present work, it is shown that such a disadvantage can be mitigated somewhat if the engineering judgement is made more

  • PDF

하나로 유동모의 시험설비의 노심채널 유동분포 해석 (The Analysis of Flow Distribution in the Core Channel of the HANARO Flow Simulated Test Facility)

  • 박용철;김경련
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2004년도 추계 학술대회논문집
    • /
    • pp.151-154
    • /
    • 2004
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality in February, 1995. Many experiments should be safely performed to activate the utilization of the HANARO. A flow simulated test facility has been developed for the verification of structural integrity of those experimental facilities prior to loading In the HANARO. This test facility is composed of three major parts; a half-core structure assembly, flow circulation system and support system. The half-core structure assembly is composed of plenum, grid plate, core channel with flow tubes, chimney and dummy pool. The flow channels are to be filled with flow orifices to simulate similar flow characteristics to the HANARO. This paper describes an analysis of the flow distribution of the cote channel and compares with the test results. As results, the analysis showed similar flow characteristics compared with those in the test results.

  • PDF

The Effect of Core Muscle Training Program on Balance Ability

  • Hwang, Hyun Sook;Kim, Nyeon Jun
    • 국제물리치료학회지
    • /
    • 제8권2호
    • /
    • pp.1175-1181
    • /
    • 2017
  • The purpose of this study was to investigate the effects of core muscle training on balance ability. Forty subjects in their 20s participated in a 6 week core muscle training program. Balance ability before and after the intervention were assessed and analyzed using the Romberg test, which was conducted on the floor, pedalo, and balancefit. The differences between the measurement methods of balance ability using varied platforms was also compared and analyzed. After the 6-week core exercise training program, the training group represented statistically significant increases in all 3 methods for static balance ability. In the control group, all 3 methods represented no statistically significant increases. Upon comparing the different methods of the Romberg test, there were no notable differences between conducting the test on varying platforms for both groups. This study suggests that the core muscle exercise training program increased the balance ability.

ROSA/LSTF test and RELAP5 code analyses on PWR 1% vessel upper head small-break LOCA with accident management measure based on core exit temperature

  • Takeda, Takeshi
    • Nuclear Engineering and Technology
    • /
    • 제50권8호
    • /
    • pp.1412-1420
    • /
    • 2018
  • An experiment was performed using the large-scale test facility (LSTF), which simulated a 1% vessel upper head small-break loss-of-coolant accident with an accident management (AM) measure under an assumption of total-failure of high-pressure injection (HPI) system in a pressurized water reactor (PWR). In the LSTF test, liquid level in the upper head affected break flow rate. Coolant was manually injected from the HPI system into cold legs as the AM measure when the maximum core exit temperature reached 623 K. The cladding surface temperature largely increased due to late and slow response of the core exit thermocouples. The AM measure was confirmed to be effective for the core cooling. The RELAP5/MOD3.3 code indicated insufficient prediction of primary coolant distribution. The author conducted uncertainty analysis for the LSTF test employing created phenomena identification and ranking table for each component. The author clarified that peak cladding temperature was largely dependent on the combination of multiple uncertain parameters within the defined uncertain ranges.

SMD Inductor Core의 전기적 특성 (The Characteristics of SMD Inductor Core)

  • 오용철;김진사;이동규;신철기;김기준;이철환
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 춘계학술대회 논문집
    • /
    • pp.85-88
    • /
    • 2005
  • In this study, it analysis electric field of SMD(Surface Mounted Device) Inductor Core and it get electric field only exist inside of SMD core. Therefore electric fields do not affect any device and equipments. These results are very important to design data acquisition system(several test equipments such as temperature, impedance, and current test), because data acquisition system can place under the SND Inductor core. So, it can be decrease their test error due to electric field.

  • PDF

Behavior of reinforced concrete segmental hollow core slabs under monotonic and repeated loadings

  • Najm, Ibrahim N.;Daud, Raid A.;Al-Azzawi, Adel A.
    • Structural Monitoring and Maintenance
    • /
    • 제6권4호
    • /
    • pp.269-289
    • /
    • 2019
  • This study investigated experimentally the response of thick reinforced concrete specimens having hollow cores with critical parameters. The investigation includes testing of twelve specimens that are solid and hollow-core slab models. Each specimen consists of two pieces, the piece dimensions are (1.2 m) length, (0.3 m) width and (20 cm) thickness tested under both monotonic and repeated loading. The test program is carried out to study the effects of load type, core diameters, core shape, number of cores, and steel fiber existence. Load versus deflection at mid span, failure modes, and crack patterns were obtained during the test. The test results showed that core shape and core number has remarkable influenced on cracking pattern, ultimate load, and failure mode. Also, when considering repeated loading protocol, the ultimate load capacity, load at yielding, and ductility is reduced.

재봉사의 가봉성 평가 -재봉사의 사절을 중심으로- (The Evaluation of Sewability for Sewing Threads -In Relation to the Breakage of Sewing Threads During Sewing Operation-)

  • 장정대
    • 한국의류산업학회지
    • /
    • 제1권2호
    • /
    • pp.154-159
    • /
    • 1999
  • In this study, for different test methods of the performance of sewing threads were used to evaluate the sewability of 10 different industrial threads. Sewability evaluations related to the breakage of thread during sewing operation were investigated by seam length and fabric thickness method (Test 1), thread tension method (Test 2), strength retention method (Test 3), and backward sewing method(Test 4), and discussed. Two of the methods, Test 1 and Test 2, simulated very harsh sewing conditions which each thread could accept as an evaluation of its sewability. Core spun thread ranked with the best sewability generally and followed by air jet textured (ATY) thread. Spun thread was superior to the filament thread in sewing thread type. In general, there was a high degree of correlation in the results of Test 1 and Test 2. The order of sewing thread by sewability test 1 was polyester spun thread, cotton thread, and p/c core spun thread. The order of sewing thread by test 2 was polyester spun thread, and p/c core spun thread. Cotton threads and cotton blended threads performed better in Test 3, and ATY threads and core spun threads in Test 4.

  • PDF