• 제목/요약/키워드: cool storage

검색결과 74건 처리시간 0.035초

도시가로공간의 공공디자인 개선사업에 따른 열환경 개선 효과 평가 (Evaluation of Thermal Environment Improvement Effect from Public Design Improvement Project on the Urban Street Space)

  • 백상훈;시미즈아키;김학윤;정응호
    • 한국환경과학회지
    • /
    • 제20권9호
    • /
    • pp.1105-1114
    • /
    • 2011
  • In this study, thermal environment improvements throughout public design improvement project on the urban street space were compared and evaluated. Thermo-Render 3.0, 3D-CAD based thermal environment simulation program, had been used for thermal environment improvement evaluations. Followings are the results. First, clayey blocks which have low heat transfer rate and cool island effect by trees and roof gardens brought cooling effects for buildings and surface of streets. Seconds, MRT values showed low levels because of low radiant mulching materials. Thirds, roof gardens contributed to reduce heat island effect since HIP levels were affected by decreasing heat storage effect of buildings from roof gardens. As a result, reducing heat storage effect throughout selecting and arranging proper materials which would not increase heat island potentials should be performed to improve heat island effects.

형광물질을 이용한 대기 중 오존 Passive Sampler의 개발 (Development of a Passive Sampler using a Fluorescence Material for the Ambient Ozone)

  • 임봉빈;정의석;김선태
    • 한국대기환경학회지
    • /
    • 제20권4호
    • /
    • pp.483-491
    • /
    • 2004
  • The purpose of this study is to develop an ozone passive sampler and to evaluate its performance p-Acetamidophenol using as the reagent for ozone reacts specifically with the ambient ozone to produce a fluorescence material (p-acetamidopheonl dimer). The volume of absorbent solution and the extraction time determined at suitable conditions for measuring ozone were 100$\mu$L and 60 min, respectively. The changes of fluorescence were observed with incresing the storage period of passive samplers in ambient air. but the cool storage in a refrigerator did not remarkably influence the increase of fluorescence. The measurement for the precision oi the passive sampling was carried out with duplicate measurement of passive samplers. The intra-class correlation coefficients of passive samplers using dry and wet filters were 0.992 and 0.962, respectively The results from field validation tests indicated practical agreement (dry filter: r=0.963, wet filter: r=0.995) between the passive sampler and an UV photometric $O_3$ analyzer. The limit of quantification of ozone passive samplers with sampling time of 8 hr (wet filter) and 24 hr (dry filter) were 8.0 ppb and 2.7 ppb, respectively.

고체질소를 이용한 이동형 초전도 에너지 저장장치용 냉각 시스템 설계 (Design of a Cooling System for a portable HTS Superconducting Magnetic Energy Storage Using a Solid Nitrogen)

  • 김광록;송정빈;김경준;이종훈;이해근;고득용;김석호;성기철
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권3호
    • /
    • pp.27-31
    • /
    • 2008
  • In order to cool the SMES coil to the operating temperature, conduction cooling is generally used. However, it often consumes a large amount of electric power because of it's continuous cryocooler operation. This can also lead to poor thermal stability and serious protection problems of the system. Solid nitrogen (SN2) can counter those disadvantages in the conduction cooling system because it has a large heat capacity. Particularly, a large amount of enthalpy with a minimal weight to the cold body of SN2 makes a compact and portable system by increase a recooling to recooling time period (RRTP) value. A conceptual design of the proto-type SN2 cooling system for a portable HTS superconducting magnetic energy storage (SMES) system will be introduced in this paper.

실험을 통한 BIPV/T 시스템 성능분석-1. PV 발전효율 (Performance Analysis of the BIPV/T system by the performance Test- Part1. PV efficiency)

  • 이현주;조혜진
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.445-450
    • /
    • 2012
  • BIPV/T (Building Intergrated PhotoVoltaic/Thermal) is combined system produces electricity and thermal energy. The heat from PV modules should be removed for better electrical performance, and can be converted into useful thermal energy. The efficiency of the PV system's performance will raise by the system removes heat from the PV. The test system is installed to top floor of the experimental house in the KEPCO Research Institute. The planned experiment is following. (1) Supplying heat energy to top floor. (2) Supplying heat and cool energy to thermal storage in the bottom of the top floor. (3) Supplying heat energy to EHP for improved performance. The experimental performance is executed from 13th February to 13th March, 2012. The solar generation of electricity is 4.04kWh under the horizontal solar radiation is $1000W/m^2$ and the air temperature is $25^{\circ}C$.

  • PDF

빙축열을 이용한 저온급기/급수 냉방 시스템 (Cold Air/Water Distribution System with Ice Storage)

  • 김경훈;이종원
    • 대한설비공학회지:설비저널
    • /
    • 제20권2호
    • /
    • pp.125-133
    • /
    • 1991
  • This paper presents some design guidelines for using cold air/water distribution to cool commercial and industrial buildings. Cold air /water distribution systems provide primary air/water for space conditioning at nominal temperature between $3^{\circ}C$ and $10^{\circ}C$ ($4{\sim}5^{\circ}C$ might be recommendable for better selection). By using lower temperature primary air/water equipment could be downsized, means lower first costs, and often reduce annual energy costs up to 50% less than that of the conventional ($13^{\circ}C$) system. This concept takes full advantages of the $2{\sim}4^{\circ}C$ chilled water (brine) available with ice storate systems.

  • PDF

꽃 저장용 냉장시스템과 태양열 복합형 급탕기 개발연구(I) (The R&D of hot water production by the combination of solar thermal and a large sized flower cooling system(I))

  • 정현채;김기선;선경호
    • 태양에너지
    • /
    • 제12권3호
    • /
    • pp.84-93
    • /
    • 1992
  • 본 연구에서는 꽃저장용 냉장시스템 등에 태양열을 이용할 수 있는 난방시스템을 조합하여 충분한 양의 고온을 확득하여 주택의 난방을 가능케 하는 시스템을 설계, 제작했다. 압축기는 기존의 압축기 냉각방식을 공냉식에서 수냉식으로 전환시켜 적절한 냉각효과의 증대는 물론 냉열을 회수하여 고온의 온수를 빠른 시간 내에 획득할 수 있는 시스템을 개발했다.

  • PDF

고온 초전도 SMES용 전도냉각시스템 특성시험 (Test of the Conduction Cooling System for HTS SMES)

  • 염한길
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권1호
    • /
    • pp.62-66
    • /
    • 2008
  • The characteristic of the superconducting magnetic energy storage(SMES) system is faster response, longer life time, more economical, and environment friendly than other uninterruptible power supply(UPS) using battery. So, the SMES system can be used to develop methods for improving power quality where a short interruption of power could lead to a long and costly shutdown. Recently, cryogen free SMES has developed using BSCCO(Bismuth Strontium Calcium Copper Oxide) wire. We fabricated and tested the conduction cooling system for the 600 kJ class HTS SMES. The experiment was accomplished for the simulation coils. The simulation coils were made of aluminium, it is equivalent to thermal mass of 600 kJ HTS SMES coil. The coil is cooled with two GM coolers through the copper conduction bar. In this paper, we report that the test results of cool-down and heat loads characteristics of the simulation coils. The developed conduction cooling system adapted to 600 kJ HTS SMES system and cope with the unexpected sudden heat impact, too.

에어컨 온도상승에 따른 온열쾌적성 변화에 관한 연구 (Research on Thermal Comfort by Increasing Air Conditioner Temperature)

  • 김형철;금종수;김동규;정용현
    • 수산해양교육연구
    • /
    • 제18권2호
    • /
    • pp.77-84
    • /
    • 2006
  • This research evaluates thermal comfort by comparing the case of maintain cooing temperature of room with the case of raising it at the point of time that human body begins to adapt. An experiment uses constant temperature & humidity chamber 2 places. Pretesting room make up summer season environment, the testing room control by air-conditioner. In condition that maintain temperature of $33^{\circ}C$. The subjects stay in the pretesting room during the 30 minute for the heat storage amount of the normal summertime. The subjects stay in the testing room under each case (case 1: maintaining $24^{\circ}C$, case 2: maintaining $26^{\circ}C$, case 3: up $1^{\circ}C$ after maintaining $24^{\circ}C$ during 30 minute, case 4: up $1^{\circ}C$ after maintaining $26^{\circ}C$ during 40 minute). 1. Result of comparison of case 1 and case 2 appears that thermal sensitive vote examine from slight cool to cool and thermal comfort examine slight comfort by temperature rise at human body adaptation point of time.2. Test of case 3 and case 4 appear similar value at thermal sensitive vote and thermal comfort.3. Through the case 2 and case 4, continuous thermal comfort maintain at $24^{\circ}C$, if raise $26^{\circ}C$, same thermal comfort maintain after a human body adaptation temperature rising effect bring energy saving.

대용량 액체수소 인수기지 쿨다운 해석 기술 연구 (Study on Cool-down Analysis Technology for Large Scale Liquid Hydrogen Receiving Terminal)

  • 박창원;김동혁;이영범;서흥석;권용수
    • 한국수소및신에너지학회논문집
    • /
    • 제35권1호
    • /
    • pp.34-39
    • /
    • 2024
  • Korea government is trying to supply liquid hydrogen from another country to domestic The research for liquid hydrogen transportation and liquefaction plant of hydrogen underway for several years, and empirical research is also planned in the future. Along with the development of liquid hydrogen transport ship/liquefaction plant technology, the development of liquid hydrogen reception base technology must be carried out. In this study, a concept level liquid hydrogen receiving terminal is constructed based on the process of the LNG receiving terminal. Based on this, a study is conducted on the development of analysis technology for the amount of BOG (pipe, tank) generated during cooldown and unloading in the liquid hydrogen unloading line (loading arm to storage tank). The research results are intended to be used as basic data for the design and liquid hydrogen receiving terminal in the future.

저염 고등어 Fillet의 제조 및 저장중 품질변화 (Processing of Low Salt Mackerel Fillet and Quality Changes during Storage)

  • 이강호;홍병일;정병천
    • 한국식품과학회지
    • /
    • 제30권5호
    • /
    • pp.1070-1076
    • /
    • 1998
  • 고등어를 fillet상태로 전처리하고 경도와 염도를 갖도록 적당시간 염수처리 및 냉건한 다음 소비자 단위로 포장하여, 저온유통시 상당한 보장력을 갖는 제품을 개발하기 위해 가공조건 및 저장중의 품질변화 등을 검토하였다. 5% 및 10%의 염수를 $5^{\circ}C$에서 고등어 fillet를 염수처리한 결과, 최종 염농도는 $0.8{\sim}1.0%$였으며 $15{\sim}20$시간에 최고농도에 달하였다. 염수처리중 휘발성염기질소(VBN) 및 histamine의 생성은 30시간 염장동안 각각 15 mg/100 g, 2.5 mg/100 g 이하로서 거의 변화가 없었다. 시제품의 저장 중 휘발성염기질소는 $5^{\circ}C$저장 경우 10%염수처리구가 저장 30일까지 선도가 유지되었고, 5% 염수처리구들은 2주일이 그 한계였으나 sodium erythorbate를 첨가한 것은 저장 20일까지 연장되었다. $-2^{\circ}C$ 저장의 경우는 저장 30일경에 5%염수 처리구에서만 초기부패를 보였고 5%염수에 polyphosphate를 첨가한 시료구에서는 저장 40일경에 초기부패하였고, 그 외의 시료에서는 저장 40일까지 양호하였고, $-20^{\circ}C$ 저장구는 모든 시료구에서 저장 100일까지 거의 문제가 없었다. Histamine의 경우 모든 시료구에서 초기부패시 까지 그 함량이 미량으로 나타나 문제가 없는 것으로 나타났다. 저장 중 지질변패와 갈변도는 $5^{\circ}C$저장구 보다 $-2^{\circ}C$$-20^{\circ}C$가 안정하였고, 그 중에서 sodium erythrobate와 생강추출물을 첨가한 시료구가 효과적 이었다. 관능평가는 $5^{\circ}C$저장구의 경우 저장 $16{\sim}21$일 경에 점질물과 산패취가 발생하여 상품으로서의 가치를 상실하였고, $-20^{\circ}C$ 저장구는 저장 100일 까지 상품으로서 가치를 유지하였다.

  • PDF