• Title/Summary/Keyword: conventional water treatment

Search Result 567, Processing Time 0.03 seconds

Drainage system for leakage treatment of cement concrete structure in underground (콘크리트 지하구조물 누수 처리를 위한 유도배수시스템)

  • Kim, Dong-Gyou
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.4
    • /
    • pp.573-585
    • /
    • 2019
  • The objective of this study is to propose the drainage system that has been improved the workability, waterproofing and drainage performance to treat the leakage from the cement concrete structures in underground. It is improved that the pipe for conveying ground leak in the existing drainage system had the problem in workability and waterproof. The drainage systems with the improved pipe for conveying ground leak were constructed in conventional concrete lining tunnels to evaluate the workability, waterproofing and drainage. The waterproof and the drainage performance of the drainage system was evaluated by injecting 1,000 ml of red water in the back of the drainage system at 3 weeks, 6 weeks, 9 weeks, 11 weeks, 14 weeks, 17 weeks and 23 weeks. During 6 months of field performance test, the average daily temperature of the tunnel site was measured from $-12.4^{\circ}C$ to $19.7^{\circ}C$. The daily minimum temperature was $-17.2^{\circ}C$ and the daily maximum temperature was $26.7^{\circ}C$. There was no problem in waterproof and drainage performance on the pipe for conveying ground leak and the drainage system during 6 months for field performance test. It is concluded that the improved drainage system can be applied to various cement concrete underground structures where leakage occurs, and has little seasonal effect.

Long-term performance of drainage system for leakage treatment of tunnel operating in cold region (한랭지역에서 운영 중인 터널의 누수처리를 위한 유도배수시스템의 장기 성능 평가)

  • Kim, Dong-Gyou
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.6
    • /
    • pp.1177-1192
    • /
    • 2018
  • The objective of this study is to develop the existing drainage system for catching the partial leakage of tunnel structures operating in cold region. The drainage system consists of drainage board, Hotty-gel as a waterproofing material, cover for preventing protrusion of Hotty-gel, air nailer, fixed nail, pipe for collecting ground leak, pipe for conveying ground leak, wire-mesh, and sprayed cement mortar. The drainage systems were installed in conventional concrete lining tunnels to evaluate the site applicability and constructability. The performances of waterproof and the drainage in the drainage system were evaluated by injecting 1,000 ml of red water in the back of the drainage system at 7 days, 14 days, 21 days, 28 days, 2 months, 3 months, 4 months, 5 months, 6 months, 7 months and 8 months. During 8 months of field test, the average daily temperature of the tunnel site was measured from $-16.0^{\circ}C$ to $25.6^{\circ}C$. The daily minimum temperature was $-21.3^{\circ}C$ and the daily maximum temperature was $30.8^{\circ}C$. There was no problem in waterproof and drainage performance of the drainage board in the drainage system. However, the pipe for conveying ground leak had the leakage problem from 14 days. It is considered that the leakage of the pipe for conveying ground leak was caused by the deformation of the pipe of the flexible plastic material having a thickness of 0.2 cm by using the high pressure air nailer and the fixing pin and the insufficient thickness and width of the hotty-gel for preventing the leakage.

Development and Application of Two-Dimensional Numerical Tank using Desingularized Indirect Boundary Integral Equation Method (비특이화 간접경계적분방정식방법을 이용한 2차원 수치수조 개발 및 적용)

  • Oh, Seunghoon;Cho, Seok-kyu;Jung, Dongho;Sung, Hong Gun
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.6
    • /
    • pp.447-457
    • /
    • 2018
  • In this study, a two-dimensional fully nonlinear transient wave numerical tank was developed using a desingularized indirect boundary integral equation method. The desingularized indirect boundary integral equation method is simpler and faster than the conventional boundary element method because special treatment is not required to compute the boundary integral. Numerical simulations were carried out in the time domain using the fourth order Runge-Kutta method. A mixed Eulerian-Lagrangian approach was adapted to reconstruct the free surface at each time step. A numerical damping zone was used to minimize the reflective wave in the downstream region. The interpolating method of a Gaussian radial basis function-type artificial neural network was used to calculate the gradient of the free surface elevation without element connectivity. The desingularized indirect boundary integral equation using an isolated point source and radial basis function has no need for information about the element connectivity and is a meshless method that is numerically more flexible. In order to validate the accuracy of the numerical wave tank based on the desingularized indirect boundary integral equation method and meshless technique, several numerical simulations were carried out. First, a comparison with numerical results according to the type of desingularized source was carried out and confirmed that continuous line sources can be replaced by simply isolated sources. In addition, a propagation simulation of a $2^{nd}$-order Stokes wave was carried out and compared with an analytical solution. Finally, simulations of propagating waves in shallow water and propagating waves over a submerged bar were also carried and compared with published data.

In Vivo Artificial Parthenogenetic Treatments on Live Silkworm Moth, Bombyx mori Can Induce Higher Parthenogenesis (살아있는 누에 나방(Bombyx mori)에 대한 인공적 단위 발생 처리의 단위 발생란 유발 촉진 효과)

  • Bae, Hee Eun;Lee, Yoon Kyung;Park, So Hyun;Lee, Seul-bi;Lee, Sang Mong
    • Journal of Life Science
    • /
    • v.29 no.2
    • /
    • pp.272-278
    • /
    • 2019
  • The silkworm performs sexual reproduction for the production of its healthy offsprings from generations to generations. Parthenogenesis in the silkworm, Bombyx mori acquires immense use in the development of outstanding homozygouse lines with higher viability, hybrid vigour, combining ability and less phenotypic variability, and it can serve as a powerful tool in controlling sex of the offsprings as well as a useful tool in selection of breeding schemes. However, naturally occuring parthenogenesis in silkworm could not be found so far. Fortunately, artificial induction of parthenogenesis is possible in silkworm. So, it is very important to find out novel methods for induction of parthenogenesis. We investigated to attempt to get a novel parthenogenetic method. Accordingly, parthenogenetic studies on between unfertilized in vivo ovarian eggs of live silkworm moth(novel) and unfertilized in vitro ovarian eggs(conventional) taken out from live silkworm moth were investigated by hot water ($46^{\circ}C$), hot air ($46^{\circ}C$) and low temperature ($0^{\circ}C$ and $-20^{\circ}C$) treatments. The best ratio of parthenogenetic eggs was obtained with in vivo ovarian eggs of live silkworm moth rather than with in vitro ovarian eggs taken out from live silkworm moth in all the treatments. The optimum exposure time absolutely depended upon the temperatures of treatments and the forms of in vivo or in vitro ovarian eggs. From these results, we expect that in vivo artificial parthenogenetic treatments on live silkworm moth will be useful for the higher induction of parthenogenesis in the silkworm, B. mori.

Standardization and HPTLC Fingerprinting of a Polyherbal Unani Formulation

  • Beg, Mirza Belal;Viquar, Uzma;Naikodi, Mohammad Abdul Rasheed;Suhail, Habiba;Kazmi, Munawwar Husain
    • CELLMED
    • /
    • v.11 no.1
    • /
    • pp.4.1-4.8
    • /
    • 2021
  • Background: The Unani system of medicine has been practised since centuries for the treatment of a range of diseases. In spite of their efficacy they have been widely criticised due to the lack of standardization and poor quality control. Standardization of Unani medicine is a valuable issue at the present because they are very prone to contamination, deterioration, adulteration and variation in composition due to biodiversity as well as careless collection. Objective: To Standardize and Development of HPTLC Fingerprinting of a polyherbal Unani formulation Qurs-e-Safa. Materials and methods: The conventional and modern analytical techniques were used to standardise Qurs-e-Safa. The study was carried into three different batches of Qurs-e-Safa prepared with its ingredients. The parameters studied are organoleptic, microscopic, physicochemical parameters, phytochemical screening, TLC, HPTLC profile, aflatoxin, microbial load and heavy metal analysis. Results and conclusion: Qurṣ-e-Sa'fa is dark yellow in colour and aromatic smell. Uniformity of diameter and weight variation were found to be 13 ± 0, and 524.7 ± 1.72 mg. friability, hardness and disintegration time of all 3 batches were found to be (0.0615 ± 0.004, 0.0885 ± 0.0047 and 0.0725 ± 0.0058), (3.5 ± 0.2886, 3.67 ± 0.1674 and 3.67 ± 0.1674) and (16 to 17 minutes). Extractive value were found to be maximum in distilled water (38.488 ± 0.20, 37.3824 ± 0.38 and 39.8177 ± 0.13) followed by alcohol (27.5406 ± 0.54, 27.5656 ± 0.32 and 26.9229 ± 0.25). Loss of weight on drying, pH, total ash, acid insoluble ash, qualitative test was set in. Phytochemical screening revealed the presence of Carbohydrates, Phenols, Resins, Proteins, Steroids, fixed oil and Flavonoids. The microbial load was found absent and heavy metals were within permissible limits. The data evolved from the study may serve as a reference to validate and also help in the quality control of other finished products in future research.

Evaluation of Surface Covering Methods for Reducing Soil Loss of Highland Slope in Soybean Cultivation (고랭지 경사 밭 콩 재배지에서 토양유실경감을 위한 피복방법 평가)

  • Lee, Jeong-Tae;Lee, Gye-Jun;Ryu, Jong-Soo;Kim, Jeom-Soon;Han, Kyung-Hwa;Zhang, Yong-Seon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.5
    • /
    • pp.725-732
    • /
    • 2012
  • There is relatively high vulnerability of soil erosion in slope highland agriculture due to a reclamation of mountain as well as low surface covering during early summer with high rainfall intensity. Especially, in soybean cultivation, soil disturbance by conventional tillage and exposure of topsoil at the early stage of soybean have intensified soil loss. The aim of this study was to evaluate various surface covering methods for reducing soil loss in highland soybean cultivation. The experiment was conducted in 17% sloped lysimeter ($2.5m{\times}13.4m$) with 8 treatments. Amount of runoff water and eroded soil, and soybean growth were investigated. Surface covering through sod culture and plant residue showed 3.4~45.0 runoff water amount with $177{\sim}2,375m^3\;ha^{-1}$ compared with control ($5,274m^3\;ha^{-1}$). And the amount of eroded soil was also reduced by 95% in surface covering treatment with $0.02{\sim}1.94Mg\;ha^{-1}$ than control with $40.72Mg\;ha^{-1}$. Yields of soybean pod showed $0.3Mg\;ha^{-1}$ in rye sod culture, $1.3Mg\;ha^{-1}$ in Ligularia fischeri var. spiciformis Nakai, $0.7Mg\;ha^{-1}$ in Aster koraiensis Nakai, $0.2Mg\;ha^{-1}$ in red clover and $2.0Mg\;ha^{-1}$ in non-covering, on the other hand, covering with cut rye showed $3.8Mg\;ha^{-1}$. Conclusively, covering the soil surface with cut rye were beneficial for reduction of soil loss without decreasing soybean yield in highland sloped fields.

Antibacterial and Intracellular Clearance Effect of Saururus chinensis Baill Water Extract against Salmonella typhimurium (삼백초 수용성 추출물의 Salmonella typhimurium 균에 대한 항균 및 숙주세포 내 사멸 효과 규명)

  • Kim, Dong-Hyeok;Lee, Jin-Ju;Lim, Jeong-Ju;Kim, Dae-Geun;Kim, Gon-sub;Lee, Hu-Jang;Min, Won-gi;Rhee, Man-Hee;Chang, Hong-Hee;Kim, Suk
    • Journal of agriculture & life science
    • /
    • v.44 no.6
    • /
    • pp.111-119
    • /
    • 2010
  • Salmonella spp. are one of major pathogens for zoonosis in worldwide, and can replicate within host cells and generally cause enterocolitis and foodborne poisoning which represents a considerable public health burden. The present study was designated to investigate the safty for host cells, antibacterial effects of Saururus chinensis Baill water extract (SCWE) on pure culture and infection with Salmonella enterica serovar Typhimurium (S. typhimurium) in murine derived macrophage RAW 264.7 cells. The different treatment of SCWE concentration (1, 10 or $100{\mu}g/ml$) did not show any cytotoxic effect to RAW 264.7 cells for 24 h incubation. In determination of antibacterial activity of SCWE against S. typhimurium, bacterial viability was markedly decreased compared to SCWE-untreated control. In RAW 264.7 cells, SCWE significantly induced morphological change (p<0.05). In infection assay of S. typhimurium in RAW 264.7 cells pretreated with $100{\mu}g/ml$ of SCWE, which are non-cytotoxic concentration, bacterial uptake ability of macrophage was increased corresponding with morphological change, whereas bacterial survival rates within macrophage was markedly reduced comparing to that of SCWE-untreated control. Furthermore, nitric oxide (NO) production in SCWE-treated cells was slightly decreased until 24 h post infection. Taken together, these findings demonstrated that SCWE have the antibacterial activity for S. typhimurium and the protective effects against S. typhimurium infection through activating murine macrophage independent on NO, suggesting that SCWE were beneficial on the disease caused by intracellularly replicating pathogens as a safe alternatives of conventional chemotherapies.

Quality Assurance for Intensity Modulated Radiation Therapy (세기조절방사선치료(Intensity Modulated Radiation Therapy; IMRT)의 정도보증(Quality Assurance))

  • Cho Byung Chul;Park Suk Won;Oh Do Hoon;Bae Hoonsik
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.275-286
    • /
    • 2001
  • Purpose : To setup procedures of quality assurance (OA) for implementing intensity modulated radiation therapy (IMRT) clinically, report OA procedures peformed for one patient with prostate cancer. Materials and methods : $P^3IMRT$ (ADAC) and linear accelerator (Siemens) with multileaf collimator are used to implement IMRT. At first, the positional accuracy, reproducibility of MLC, and leaf transmission factor were evaluated. RTP commissioning was peformed again to consider small field effect. After RTP recommissioning, a test plan of a C-shaped PTV was made using 9 intensity modulated beams, and the calculated isocenter dose was compared with the measured one in solid water phantom. As a patient-specific IMRT QA, one patient with prostate cancer was planned using 6 beams of total 74 segmented fields. The same beams were used to recalculate dose in a solid water phantom. Dose of these beams were measured with a 0.015 cc micro-ionization chamber, a diode detector, films, and an array detector and compared with calculated one. Results : The positioning accuracy of MLC was about 1 mm, and the reproducibility was around 0.5 mm. For leaf transmission factor for 10 MV photon beams, interleaf leakage was measured $1.9\%$ and midleaf leakage $0.9\%$ relative to $10\times\;cm^2$ open filed. Penumbra measured with film, diode detector, microionization chamber, and conventional 0.125 cc chamber showed that $80\~20\%$ penumbra width measured with a 0.125 cc chamber was 2 mm larger than that of film, which means a 0.125 cc ionization chamber was unacceptable for measuring small field such like 0.5 cm beamlet. After RTP recommissioning, the discrepancy between the measured and calculated dose profile for a small field of $1\times1\;cm^2$ size was less than $2\%$. The isocenter dose of the test plan of C-shaped PTV was measured two times with micro-ionization chamber in solid phantom showed that the errors upto $12\%$ for individual beam, but total dose delivered were agreed with the calculated within $2\%$. The transverse dose distribution measured with EC-L film was agreed with the calculated one in general. The isocenter dose for the patient measured in solid phantom was agreed within $1.5\%$. On-axis dose profiles of each individual beam at the position of the central leaf measured with film and array detector were found that at out-of-the-field region, the calculated dose underestimates about $2\%$, at inside-the-field the measured one was agreed within $3\%$, except some position. Conclusion : It is necessary more tight quality control of MLC for IMRT relative to conventional large field treatment and to develop QA procedures to check intensity pattern more efficiently. At the conclusion, we did setup an appropriate QA procedures for IMRT by a series of verifications including the measurement of absolute dose at the isocenter with a micro-ionization chamber, film dosimetry for verifying intensity pattern, and another measurement with an array detector for comparing off-axis dose profile.

  • PDF

Monte Carlo Study Using GEANT4 of Cyberknife Stereotactic Radiosurgery System (GEANT4를 이용한 정위적 사이버나이프 선량분포의 계산과 측정에 관한 연구)

  • Lee, Chung-Il;Shin, Jae-Won;Shin, Hun-Joo;Jung, Jae-Yong;Kim, Yon-Lae;Min, Jeong-Hwan;Hong, Seung-Woo;Chung, Su-Mi;Jung, Won-Gyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.192-200
    • /
    • 2010
  • Cyberknife with small field size is more difficult and complex for dosimetry compared with conventional radiotherapy due to electronic disequilibrium, steep dose gradients and spectrum change of photons and electrons. The purpose of this study demonstrate the usefulness of Geant4 as verification tool of measurement dose for delivering accurate dose by comparing measurement data using the diode detector with results by Geant4 simulation. The development of Monte Carlo Model for Cyberknife was done through the two-step process. In the first step, the treatment head was simulated and Bremsstrahlung spectrum was calculated. Secondly, percent depth dose (PDD) was calculated for six cones with different size, i.e., 5 mm, 10 mm, 20 mm, 30 mm, 50 mm and 60 mm in the model of water phantom. The relative output factor was calculated about 12 fields from 5 mm to 60 mm and then it compared with measurement data by the diode detector. The beam profiles and depth profiles were calculated about different six cones and about each depth of 1.5 cm, 10 cm and 20 cm, respectively. The results about PDD were shown the error the less than 2% which means acceptable in clinical setting. For comparison of relative output factors, the difference was less than 3% in the cones lager than 7.5 mm. However, there was the difference of 6.91% in the 5 mm cone. Although beam profiles were shown the difference less than 2% in the cones larger than 20 mm, there was the error less than 3.5% in the cones smaller than 20 mm. From results, we could demonstrate the usefulness of Geant4 as dose verification tool.

Consideration of Surface Dose and Depth of Maximum Dose Using Various Detectors for High Energy X-rays (측정기에 따른 고에너지 X-선의 표면 선량 및 최대 선량 지점 고찰)

  • Lee Yong Ha;Park Kyung Ran;Lee Jong Young;Lee Ik Jae;Park Young Woo;Lee Kang Kyoo
    • Radiation Oncology Journal
    • /
    • v.21 no.4
    • /
    • pp.322-329
    • /
    • 2003
  • Purpose: It is difficult to exactly determine the surface dose and the dose distribution In buildup region of high energy X-rays by using the conventional ion chamber. The aim of this study Is to evaluate the accuracy of widely used dosimetry systems to measure the surface dose and the depth of maximum dose (d$_{max}$). Materials and Methods: We measured the percent depth dose (PDD) from the surface to the d$_{max}$ in either a water phantom or in a solid water phantom using TLD-100 chips, thimble type ion chamber, diode detector, diamond detector and Markus parallel plate ion chamber for 6 MV and 15 MV X-rays, 10$\times$10 cm$^{2}$, at SSD=100cm. We analysed the surface dose and the d$_{max}$. In order to verify the accuracy of the TLD data, we executed the Monte Carlo simulation for 5 MV X-ray beams. Results: The surface doses In 6 MV and IS MV X-rays were 29.31% and 23.36% ior Markus parallel plate ion chamber, 37.17$\%$ and 24.01$\%$ for TLD, 34.87$\%$ and 24.06$\%$ for diamond detector, 38.13$\%$ and 27.8$\%$ for diode detector, and 47.92$\%$ and 35.01$\%$ for thimble type ion chamber, respectively. in Monte Carlo simulation for 6 MV X-rays, the surface dose was 36.22$\%$, which Is similar to the 37.17$\%$ of the TLD measurement data. The d$_{max}$ In 6 WV and 15 MV X-rays was 14$\~$16 mm and 27$\~$29 mm, respectively. There was no significant difference in the d$_{max}$ among the detectors. Conclusion: There was a remarkable difference in the surface dose among the detectors. The Markus parallel plate chamber showed the most accurate result. The surface dose of the thimble ion chamber was 10$\%$ higher than that of other detectors. We suggest that the correction should be made when the surface dose of the thimble ion chamber Is used for the treatment planning ion the supeficial tumors. All the detectors used In our study showed no difference in the d$_{max}$.