• Title/Summary/Keyword: conventional radiography

Search Result 196, Processing Time 0.025 seconds

An Assessment of the Radiation Dose from Radiography with the Change in Air Gap (공극(기극(氣隙)) 변화에 따른 방사선촬영 선량평가)

  • Ahn, Byeong Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.381-385
    • /
    • 2016
  • This study aims to propose a method for reducing radiation dose in high-voltage radiography using air gap technique while maintaining the same image quality as when using grids. For an experiment, air gaps were set at 10 cm, 15 cm, 20 cm, 25 cm, and 30 cm with a focus-receptor distance of 180 cm; with each air gap distance, tube current was set at 15 mAs, and tube voltage was set at 80 kVp, 85 kVp, 90 kVp, 95 kVp and 100 kVp. Then, radiographs were taken. In a situation of employing a conventional method of using grids, radiographs were taken at 15 mAs and 107 kVp with a focus-receptor distance of 180 cm. According to the results of the experiment, the surface radiation dose from radiography using grids was 0.130 R; the surface radiation dose at a 20cm air gap was 0.124 R; PSNR between these two images was 10.65 [dB]. In conclusion, the air gap distance, which could maintain the image quality similar to that of a case where scattered radiation was removed and grids were used with a small surface radiation dose, was 20 cm. The result of this study is thought to be used as an indicator to remove surface radiation dose in radiography using air gap.

Radiopacity of restorative composites by conventional radiograph and digital images with different resolutions

  • Dantas, Raquel Venancio Fernandes;Sarmento, Hugo Ramalho;Duarte, Rosangela Marques;Meireles Monte Raso, Sonia Saeger;de Andrade, Ana Karina Maciel;Dos Anjos-Pontual, Maria Luiza
    • Imaging Science in Dentistry
    • /
    • v.43 no.3
    • /
    • pp.145-151
    • /
    • 2013
  • Purpose: This study was performed to evaluate and compare the radiopacity of dentin, enamel, and 8 restorative composites on conventional radiograph and digital images with different resolutions. Materials and Methods: Specimens were fabricated from 8 materials and human molars were longitudinally sectioned 1.0 mm thick to include both enamel and dentin. The specimens and tooth sections were imaged by conventional radiograph using #4 sized intraoral film and digital images were taken in high speed and high resolution modes using a phosphor storage plate. Densitometric evaluation of the enamel, dentin, restorative materials, a lead sheet, and an aluminum step wedge was performed on the radiographic images. For the evaluation, the Al equivalent (mm) for each material was calculated. The data were analyzed using one-way ANOVA and Tukey's test (p<0.05), considering the material factor and then the radiographic method factor, individually. Results: The high speed mode allowed the highest radiopacity, while the high resolution mode generated the lowest values. Furthermore, the high resolution mode was the most efficient method for radiographic differentiation between restorative composites and dentin. The conventional radiograph was the most effective in enabling differentiation between enamel and composites. The high speed mode was the least effective in enabling radiographic differentiation between the dental tissues and restorative composites. Conclusion: The high speed mode of digital imaging was not effective for differentiation between enamel and composites. This made it less effective than the high resolution mode and conventional radiographs. All of the composites evaluated showed radiopacity values that fit the ISO 4049 recommendations.

Evaluation of Chest Density in Insight Film (Insight film을 이용한 농도측정 평가)

  • Kwon, Lee-Seon;Park, Jang-Hwan;Lim, Oh-Soo;Jung, Kyong-Mo;Cheung, Hwan
    • Journal of radiological science and technology
    • /
    • v.15 no.2
    • /
    • pp.17-23
    • /
    • 1992
  • Simple chest radiography is the most frequently performed examination in radiologic practice. However, with transmitted dose through chest which has the problem of wide variations in absorption, conventional Film/Screen Combinations Method make it difficult to delineate lung field mediastinum & cardia portion and subdiaphragmatic structures. In order to overcome this problem, we have been tried several methods as follows. High Kilovoltage Technique, Rare Earth Screen/Wide Lattitude Film, Use of Compensating Filter and Digital Beam Attenuator and recently Insigh System has been developed. In this paper, we'd like to discuss Insight film through apperciation by measuring the difference of contrast. In order to evaluate insight film. We have done experiments using Insight System with Simple Phase, Picker 550. We could get an result which was able to overcome the limitted dynamic range of conventional Film/Screen System remarkably.

  • PDF

Thoracic Vertebrae Lateral Projection in Radiography (흉추(胸椎) 측면촬영(側面撮影)에 대(對)한 검토(檢討))

  • Choi, Jong-Hak;Jeon, Man-Jin;Kim, Young-Ill;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.1 no.1
    • /
    • pp.25-29
    • /
    • 1978
  • This study was done for the purpose of graphing rather improved technique through reviewing conventional technigue of the thoracic vertebrae lateral projection. The roentgenographic images which were taken at Korea University Hospital from January, 1976 to December, 1977 were observed for this study. The results were as belows: 1. The quality of diagnostic radiograph turned out that good is 21.4%, intermediate is 40.7% and poor is 37.9%. 2. The poor quality of images the caused by overlapping shadows(59.6%), incorrect position of patients(15.0%), motion of patients(7.5%), over-exposure(8.3%), under-exposure(6.7%) and processing faults(2.9%). The images were taken by following four methods of experiments were campared and researched in order to improve the problems of conventional technigues which were came out on the poor radiographes. 1. (Method 1) Low mA-long time exposure during normal respiration 2. (Method 2) Short time exposure during normal respiration 3. (Method 3) After deep inspiration, short time exposure during expiration 4. (Method 4) After full expiration, short time exposure during inspiration. In a result of the above experiments, it was found that the improved image could be got from the method 3.

  • PDF

A Case of Bronchial Foreign Body Reconstructed with Virtual Bronchoscopy (가상 기관지경으로 재구성한 기관지 내 이물 1예)

  • Yoo, Young Sam;Kim, Sang Woo;Woo, Kuk Sung;Kim, Dong Won;Choi, Sang Bong
    • Korean Journal of Bronchoesophagology
    • /
    • v.17 no.2
    • /
    • pp.116-119
    • /
    • 2011
  • Computed tomography with virtual bronchoscopy shows inner shape of trachea and major bronchi with three-dimensional images. Virtual bronchoscopy can be used in cases of suspected foreign body aspiration. Virtual bronchoscopy shows the exact location of the obstructive lesion before conventional bronchoscopy. If the chest radiography is normal or suggests aspirated foreign body, virtual bronchoscopy can be considered before conventional bronchoscopy. We experienced a case of false-tooth foreign body extracted under bronchoscopy. In this case, virtual bronchoscopy was made retrospectively giving useful information about shape and orientation regarding foreign body.

  • PDF

Evaluation of dental panoramic radiographic findings in edentulous jaws: A retrospective study of 743 patients "Radiographic features in edentulous jaws"

  • Kose, Taha Emre;Demirtas, Nihat;Karabas, Hulya Cakir;Ozcan, Ilknur
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.5
    • /
    • pp.380-385
    • /
    • 2015
  • PURPOSE. The aim of this study was to determine the frequency of significant panoramic radiographic findings and eventual treatment requirements before conventional or implant supported prosthetic treatment in asymptomatic edentulous patients. MATERIALS AND METHODS. A total of 743 asymptomatic edentulous patients were retrospectively evaluated using a digital panoramic system. We analyzed the radiographic findings, including impacted teeth, retained root fragments, foreign bodies, severe atrophy of the posterior maxillary alveolar bone, mucous retention cysts, soft tissue calcifications and radiopaque-radiolucent conditions. RESULTS. Four-hundred-eighty-seven (65.6%) patients had no radiographic finding. A total of 331 radiographic findings were detected in 256 (34%) patients. In 52.9% (n=175) of these conditions, surgical treatment was required before application of implant-supported fixed prosthesis. However, before application of conventional removable prosthesis surgical treatment was required for 6% (n=20) of these conditions. CONCLUSION. The edentulous patients who will have implant placement for implant-supported fixed prosthesis can frequently require additional surgical procedures to eliminate pathological conditions.

Measurement of MTF in Display image on monitor by SWRF (SWRF를 이용한 전시영상의 MTF 측정)

  • Kim, Chang-Bok;Lee, Kyung-Sup;Kim, Young-Keun;Cho, Su-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11b
    • /
    • pp.15-17
    • /
    • 2004
  • The quality of X -ray image is depending on the acquired signal pattern So far, the MTF(modulation transfer function) of medical image system has been obtained through various kinds of calculationprocesses after using SWRF (A square wave response function method) to print out it into films. In this study, a tool has been developed that can help the actual user who actually creates the medical images measure the MTF of the finaldisplay image very simply by applying Borland C++ builder software as well as LEAD tools software for the SWRF calculation process to analyze the MTF even on the display image. Films have been printed out by this newly developed MTF measuring tool under the same conditions with the ones for the existing tools and also the calculation method has shown no difference with any existing SWRF calculation method. By using this, it was found out that the MTF of the resolving power of the computed radiography(CR) Image plate (IP) that is a conventional X-ray detection system Jar the conventional X-ray purpose was about 10% at the range of 3.00 LP/mm.

  • PDF

Evaluation on the efficacy and safety of calcium metaphosphate coated fixture

  • Cho, In-Ho;Lee, Jae-Hoon;Song, Young-Gyun;Kim, Young-Mi;Jeon, So-Young
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.2
    • /
    • pp.172-178
    • /
    • 2013
  • PURPOSE. The purpose of this study was to assess the difference in efficacy between calcium metaphosphate (CMP)-coated implant fixtures and conventional resorbable blasted media (RBM) processed implant fixtures. MATERIALS AND METHODS. This study targeted 50 implants from 44 patients who visited Dankook University Dental Hospital. Implantations were done separately for RBM treated and CMP-coated implants, although their design was the same. Calcium metaphosphate has a quicker biodegradation process through hydrolysis compared to other phosphate calcium groups. For the first year of the implantation, the resorption volume of marginal bone analyzed via radiography and perio-test value were measured, under the check plan. Their analyses were composed of a non-inferiority trials test. A 95% level of reliability was used. RESULTS. In the comparative analysis of the resorption volume of marginal bone and the perio-test value, no statistically significant difference was found between the CMP-coated implants and RBM implants. CONCLUSION. One year after the implant placement, CMP-coated implants were found not to be inferior to the conventional RBM implants.

Appearance of nasopalatine duct cysts on dental magnetic resonance imaging using a mandibular coil: Two case reports with a literature review

  • Adib Al-Haj Husain ;Daphne Schonegg ;Silvio Valdec ;Bernd Stadlinger ;Marco Piccirelli ;Sebastian Winklhofer
    • Imaging Science in Dentistry
    • /
    • v.53 no.2
    • /
    • pp.161-168
    • /
    • 2023
  • Nasopalatine duct cysts (NPDCs), the most common non-odontogenic cysts of maxilla, are often incidental findings on diagnostic imaging. When symptomatic, they usually present as a painless swelling with possible fistula. Conventional radiography shows a round-to-ovoid or heart-shaped radiolucency between the roots of central maxillary incisors. While the radiographic features of NPDCs in X-ray-based modalities have been well described, their magnetic resonance imaging (MRI) features have rarely been reported. Developments in dental MRI in recent years and the introduction of various dental MRI protocols now allow a wide range of applications in dental medicine. MRI is becoming an important tool for the detection and diagnosis of incidental or non-incidental dentomaxillofacial cysts. This report presented and discussed the characteristics of 2 NPDC cases visualized on MRI using both conventional and newly implemented specific dental MRI protocols with a novel 15-channel mandibular coil, demonstrating the use of these protocols for radiation-free maxillofacial diagnoses.

Diffuse Infiltrative Lung Disease : Comparison of Diagnostic Accuracies of High-Resolution CT and Radiography (미만성 침윤성 폐질환의 진단: HRCT와 단순흉부X선사진의 비교)

  • Kim, Kyeong-Ah;Kang, Eun-Young;Oh, Yu-Whan;Kim, Jeung-Sook;Park, Jai-Soung;Lee, Kyung-Soo;Kang, Kyung-Ho;Chung, Kyoo-Byung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.3
    • /
    • pp.388-402
    • /
    • 1996
  • Background : To compare the diagnostic accuracies of High-resolution CT(HRCI) and chest radiography in the diagnosis of diffuse infiltrative lung disease(DILD). Methods : This study included ninety-nine patients with a diagnosis of acute or chronic DILD, representing 20 different diseases. Twelve normal subjects were included as control. The disease state was confirmed either pathologically or clinically. Radiographs and CT scans were evaluated separately by three independent observers without knowledge of clinical and pathologic results. The observers listed three most likely diagnoses and recorded degree of confidence. Results : The sensitivity of HRCT in the detection of DILD was 98.9% compared to 97.9% of chest radiography. Overall, a correct first-choice diagnosis was made in 48% using chest radiographs and in 60% using HRCT images. The correct diagnosis was among the top-three choices in 64% when chest radiographs were used, and in 75% when HRCT images were reviewed. Overally a confident diagnosis was reached more often with HRCT(55%) than with chest radiography(26%). The correct first-choice diagnosis increased remarkably when the HRCT was used in usual interstitial pneumonia, miliary tuberculosis, diffuse panbronchiolitis and lymphangitic carcinomatosis. Conclusion : HRCT is confirmed to be superior to conventional radiography in the detection and accurate diagnosis of DILD. HRCT is especially valuable in the diagnosis of usual interstitial pneumonia, miliary tuberculosis, diffuse panbronchiolitis, and lymphangitic carcinomatosis.

  • PDF