• 제목/요약/키워드: conventional concrete

검색결과 1,216건 처리시간 0.028초

Numerical analysis of channel connectors under fire and a comparison of performance with different types of shear connectors subjected to fire

  • Shahabi, S.E.M.;Ramli Sulong, N.H.;Shariati, M.;Mohammadhassani, M.;Shah, S.N.R.
    • Steel and Composite Structures
    • /
    • 제20권3호
    • /
    • pp.651-669
    • /
    • 2016
  • The behavior of shear connectors plays a significant role in maintaining the required strength of a composite beam in normal and hazardous conditions. Various types of shear connectors are available and being utilized in the construction industry according to their use. Channel connectors are a suitable replacement for conventional shear connectors. These connectors have been tested under different types of loading at ambient temperature; however, the behavior of these connectors at elevated temperatures has not been studied. This investigation proposes a numerical analysis approach to estimate the behavior of channel connectors under fire and compare it with the numerical analysis performed in headed stud and Perfobond shear connectors subjected to fire. This paper first reviews the mechanism of various types of shear connectors and then proposes a non-linear thermo-mechanical finite element (FE) model of channel shear connectors embedded in high-strength concrete (HSC) subjected to fire. Initially, an accurate nonlinear FE model of the specimens tested at ambient temperature was developed to investigate the strength of the channel-type connectors embedded in an HSC slab. The outcomes were verified with the experimental study performed on the testing of channel connectors at ambient temperature by Shariati et al. (2012). The FE model at ambient temperature was extended to identify the behavior of channel connectors subjected to fire. A comparative study is performed to evaluate the performance of channel connectors against headed stud and Perfobond shear connectors. The channel connectors were found to be a more economical and easy-to-apply alternative to conventional shear connectors.

코너프로텍션 설치에 따른 멤브레인 LNG 저장탱크 시스템의 응력 및 변형거동 특성에 관한 수치해석 (Numerical Analysis on the Stress and Deformation Characteristics of LNG Membrane Storage Tank System with Corner Protection)

  • 김청균
    • 한국가스학회지
    • /
    • 제13권6호
    • /
    • pp.9-14
    • /
    • 2009
  • 본 연구에서는 LNG 저장탱크의 단열재 공간에 설치된 코너프로텍션에 작용하는 응력 및 변형거동 특성을 FEM으로 해석하였다. 제시된 코너프로텍션은 기존의 멤브레인식 LNG 저장탱크의 강도안 전성과 LNG 누출안전성을 증대시킬 수 있다. LNG 저장탱크 시스템에 작용하는 응력과 변위 거동량을 단열재 상자, 멤브레인 내부탱크, PC 외부탱크에 대하여 해석하였다. 유한요소법으로 계산한 해석결과에 의하면, 내부탱크와 외부탱크 사이에 코너프로텍션을 설치한 새로운 LNG 멤브레인 저장탱크의 응력과 변형 거동량은 기존의 LNG 저장탱크에 비하여 현저하게 줄어드는 경향을 보여주고 있다. 이러한 현상은 LNG 저장탱크 시스템의 강도 안전성이 코너프로텍션을 설치함에 따라서 강성도가 증가하기 때문인 것으로 설명될 수 있다.

  • PDF

완충재의 동특성에 따른 중량충격음 증폭에 관한 해석적 연구 (The Effect of Dynamic Property of Absorbing Sheet on the Amplification of Heavy Weight Floor Impact Noise)

  • 황재승;문대호;박홍근;홍성걸;홍건호
    • 한국소음진동공학회논문집
    • /
    • 제20권7호
    • /
    • pp.651-657
    • /
    • 2010
  • Previous experimental results performed by many researchers for a couple of decades in South Korea have shown that an absorbing sheet inserted in a conventional floating slab system for thermal insulation or vibration absorption may amplify the vibration of the slab system at specific frequency ranges depending on the material properties of the sheet. The amplified vibration, consequently, results in the heavy weight floor impact noise exceeding the sound level limit for an apartment house, 50 dB. In this study, the amplification mechanism is examined through numerical analysis and a new slab system is proposed to reduce the amplification and control the noise. The new slab system consists of studs connecting the base slab and upper concrete finishing yielding the dramatically increased stiffness of the slab. The numerical simulation is performed to investigate the effect of the slab system with studs on the vibration and noise control. The results show that the performance of the slab is sensitive to the number and location of studs, and the heavy weight floor impact noise can be reduced up to 6~7 dB compared to the conventional slab system at the optimal stud location.

지오폴리머의 강도와 내구성에 영향을 미치는 요인에 대한 고찰 (Factors Effecting the Strength & Durability of Geopolymer Binder: A Review)

  • 온정권;김규용;사수이;이예찬;유하민
    • 한국건설순환자원학회논문집
    • /
    • 제9권4호
    • /
    • pp.460-468
    • /
    • 2021
  • 이산화탄소 및 온실가스의 배출, 과도한 에너지 소비 및 천연자원의 고갈을 막기 위해 콘크리트의 대체재를 찾는 것은 건설업의 해결과제이다. 이러한 문제를 해결하기 위해, 콘크리트보다 환경친화적인 지오폴리머가 주목을 받고 있으며, 실제 시공을 목적으로 강도 및 내구성에 대한 연구가 진행되고 있다. 일반적으로, 지오폴리머의 강도 및 내구성은 알칼리 용액의 종류 및 농도, 전구물질, 양생 온도 및 시간 등 여러 요인에 따라 달라지며, 이는 지오폴리머의 강도와 내구성에 영향을 미치는 화학조성 및 미세구조에 큰 영향을 미친다. 기존의 연구에서 최적의 알칼리 용액의 종류 및 농도, 전구물질, 양생 온도 및 시간을 통하여 지오폴리머의 압축강도 및 내구성이 향상되는 것을 확인하였으며, 본 연구에서는 과거의 연구 결과를 검토하고 이러한 요인이 지오폴리머의 압축강도 및 내구성에 미치는 영향을 체계적으로 종합하였다.

A Study on Sustainable Greenspace based on Urban Remodeling Design of an Old Apartment Building

  • Myung Sik Lee;Seung Ryeol Min
    • 국제초고층학회논문집
    • /
    • 제12권2호
    • /
    • pp.179-193
    • /
    • 2023
  • It is undeniable that urban greenspace is the soul of a city. Conventional urban greenspace such as parks, community gardens, playgrounds etc. located within a city reduce the negative effects of pollution, play a major role in the survival of the urban ecosystem, and promote healthy lifestyles. Today, 55% of the world's population lives in urban areas, which is expected to increase to 68% by 2050. Projections show that urbanization and the gradual migration to urban areas combined with the fast growth of the world's population, could add another 2.5 billion people to urban areas by 2050 and almost 90% of this increase will take place in Asia(UN, 2018). As a result, many plots in the cities are and will continue to be occupied with buildings to provide residential support to the increased population. This will dangerously decrease urban greenspaces. Moreover, worldwide, food crisis, energy crisis, and social crisis is posing a great threat to the existence of mankind. Additionally, the COVID - 19 has introduced a new lifestyle where from work culture to community configuration has drastically transformed. In this scenario, residential buildings will have to serve more than just providing privacy and shelter. As urban greenspaces are being occupied by concrete residential buildings, these buildings will have to compensate for the percentage of urban green they are destroying and the issues they are imposing in the process. The goal of this thesis is to design, architecturally define and, categorize comprehensive 'sustainable Greenspace'(S.G.S) for the multi-family housing scenario. These will be different than the conventional green (veranda, rooftop green) we commonly see in residential buildings. An old, dilapidated apartment building will be the target of remodeling to fulfill the purpose of this thesis.

A novel adaptive unscented Kalman Filter with forgetting factor for the identification of the time-variant structural parameters

  • Yanzhe Zhang ;Yong Ding ;Jianqing Bu;Lina Guo
    • Smart Structures and Systems
    • /
    • 제32권1호
    • /
    • pp.9-21
    • /
    • 2023
  • The parameters of civil engineering structures have time-variant characteristics during their service. When extremely large external excitations, such as earthquake excitation to buildings or overweight vehicles to bridges, apply to structures, sudden or gradual damage may be caused. It is crucially necessary to detect the occurrence time and severity of the damage. The unscented Kalman filter (UKF), as one efficient estimator, is usually used to conduct the recursive identification of parameters. However, the conventional UKF algorithm has a weak tracking ability for time-variant structural parameters. To improve the identification ability of time-variant parameters, an adaptive UKF with forgetting factor (AUKF-FF) algorithm, in which the state covariance, innovation covariance and cross covariance are updated simultaneously with the help of the forgetting factor, is proposed. To verify the effectiveness of the method, this paper conducted two case studies as follows: the identification of time-variant parameters of a simply supported bridge when the vehicle passing, and the model updating of a six-story concrete frame structure with field test during the Yangbi earthquake excitation in Yunnan Province, China. The comparison results of the numerical studies show that the proposed method is superior to the conventional UKF algorithm for the time-variant parameter identification in convergence speed, accuracy and adaptability to the sampling frequency. The field test studies demonstrate that the proposed method can provide suggestions for solving practical problems.

산업부산물 구형골재를 사용한 폴리에스테르 폴리머 콘크리트의 특성(III) (아토마이징 제강슬래그를 충전재와 잔골재로 사용) (Characteristics of Polyester Polymer Concretes Using Spherical Aggregates from Industrial By-Products (III) (Using an Atomizing Steel Slag as a Filler and Fine Aggregate))

  • 황의환;김진만
    • 공업화학
    • /
    • 제26권1호
    • /
    • pp.104-110
    • /
    • 2015
  • 폴리머 콘크리트는 보통 포틀랜드 시멘트 콘크리트에 비하여 가격이 8~10배 비싼 것으로 알려져 있다. 그러므로 폴리머 콘크리트 제품 생산에 있어서 생산비의 대부분을 차지하는 폴리머 결합재의 사용량을 절감하는 것이 매우 중요하다. 폴리머 결합재의 절감기술을 개발하기 위하여 철강 산업에서 발생되는 제강 산화공정 슬래그와 환원공정 슬래그를 사용하여 아토마이징 공법으로 표면이 매끄러운 구형의 골재를 제조하였다. 폴리머 콘크리트 제조에 일반적으로 사용되는 탄산칼슘(충전재)과 강모래(잔골재) 대신 구형의 아토마이징 산화공정 슬래그와 환원공정 슬래그를 사용하면 최밀 충전효과와 볼베어링 효과로 작업성이 향상되어 폴리머 결합재의 절감효과를 기대할 수 있다. 폴리머 콘크리트 복합재료의 물성을 조사하기 위하여 폴리머 결합재의 첨가율과 아토마이징 제강 환원슬래그의 대체율에 따라 다양한 배합의 폴리머 콘크리트 공시체를 제조하였다. 시험결과, 아토마이징제강 슬래그의 대체율이 증가됨에 따라 공시체의 압축강도는 증가되었으나 휨강도는 폴리머 결합재의 첨가율에 따라 최대값이 다르게 나타났다. 내열수성시험에서 압축강도, 휨강도, 밀도 및 세공의 평균직경은 감소되었으나 총세공량과 공극률은 증가되었다. 탄산칼슘과 강모래대신 구형의 아토마이징 제강 산화슬래그와 아토마이징 제강 환원슬래그를 사용하여 만든 폴리머 콘크리트는 작업성이 현저히 개선되어 종래의 제품보다 폴리머 결합재의 사용량을 19.0% 절감할 수 있는 것으로 나타났다.

화상계측기법에 의한 전단압축파괴형 보의 국부변형률분포 추정 (Estimation of Local Strain Distribution of Shear-Compressive Failure Type Beam Using Digital Image Processing Technology)

  • 권용길;한상훈;홍기남
    • 콘크리트학회논문집
    • /
    • 제21권2호
    • /
    • pp.121-127
    • /
    • 2009
  • 연화재료의 변형률 국부화 거동에 따른 파괴영역과 파괴영역 내에서의 변형률 추이는 구조물의 극한거동에 큰 영향을 미치지만 파괴영역의 예측과 영역 내에서의 변형률을 정량화하는 것은 실험적으로 명확히 구명되어 있다고 보기 어렵다. 이 연구에서는 국부화된 파괴영역 및 그 영역 내에서의 변형률 분포 추이를 추정하기 위해 화상처리기법을 이용하였다. 화상처리기법의 신뢰성 및 타당성을 검증하기 위해, 일축압축공시체를 대상으로 화상처리기법을 이용하여 변형률을 추정하고, 이를 콘크리트 게이지로부터 취득한 변형률과 비교분석하였다. 분석 결과를 바탕으로 전단압축파괴형 보의 정적파괴실험에 화상처리기법을 적용하여 실험체의 거동에 따른 주인장변형률 및 주압축변형률의 분포도를 작성하였다. 마지막으로 작성된 분포도를 이용하여 국부화영역 및 국부변형률을 추정하였다. 실험 결과, 화상처리기법을 이용하여 취득한 파괴영역 내에서의 변형률 분포 추이는 비교적 정확히 실험체의 거동을 예측할 수 있었으며 손상 정도에 따라 비교적 합리적인 국부변형률값을 얻을 수 있었다.

슬래그부산물을 자극제로 활용한 고활성 고로슬래그 미분말 모르타르의 압축강도 발현 특성 (Properties of Compressive Strength of Mortar Based on High-activated Blast Furnace Slag using the Slag by-product as an Activator)

  • 이보경;김규용;구경모;신경수
    • 한국건축시공학회지
    • /
    • 제14권1호
    • /
    • pp.37-44
    • /
    • 2014
  • 건설산업에서는 탄산가스 저감을 위해 산업부산물을 다량 활용하는 기술개발을 위한 연구가 이루어지고 있다. 산업부산물 중 특히 고로슬래그 미분말은 잠재수경성에 기인하여 장기강도는 우수하나 초기강도가 낮기 때문에 많은 양을 대체하는데 한계가 있다. 이에 본 연구에서는 철강공정 중 용선예비처리 공정에서 발생하는 슬래그부산물을 활용하여 고활성 고로슬래그 미분말을 시험 제조후 고활성 고로슬래그 미분말의 모르타르 압축강도 강도발현 특성을 검토하였다. 또한, 고활성 고로슬래그 미분말 단독으로도 경화가 가능한 특징을 고려해서 2차 콘크리트 제품용 결합재로서 활용 가능성을 검토하고자 배합조건에 따른 콘크리트 제조 및 압축강도 발현특성을 검토하였다. 실험변수로써 슬래그부산물의 분말도, 치환율, 양생조건 및 W/B를 설정하였다. 그 결과 슬래그부산물을 자극제로 활용한 고활성 고로슬래그 미분말 모르타르의 압축강도 향상을 확인하였으며 고활성 고로슬래그 미분말이 단독으로도 경화가 가능하기 때문에 양생 및 배합조건을 고려하면 고활성 고로슬래그 미분말을 콘크리트 2차 제품용 결합재로서 활용 가능할 것으로 판단된다.

경계부재내 횡보강근 배근방법에 따른 R/C전단벽의 반복하중에 대한 이력거동 (Hysteretic Behavior of R/C Shear Wall with Various Lateral Reinforcements in Boundary Columns for Cyclic Lateral Load)

  • 서수연;오태근;김경태;윤승조
    • 콘크리트학회논문집
    • /
    • 제22권3호
    • /
    • pp.357-366
    • /
    • 2010
  • 이 연구에서는 경계부재내에 다양한 형태의 횡보강근 상세를 가진 전단벽에 대한 실험연구를 다루고자 한다. 연구의 주요 내용은 시공성 개선을 위해 사각나선 횡보강근과 헤드가 있는 크로스타이로 전단벽의 경계부재내 콘크리트를 구속함에 따른 거동을 실험적으로 관찰하는 것이다. 이 두 가지 상세는 공장에서 제작된 후 현장에서 조립만 할 경우, 현장작업량을 줄일 수 있는 상세로 고려될 수 있으며, 이 연구에서는 이 두 가지 상세를 가진 전단벽에 대한 구조성능을 구명하고자 한다. 실험의 주요변수는 경계부재내 횡보강근의 형태로서 기존의 띠철근, 사각나선근, 그리고 기존 크로스타이와 헤드가 있는 크로스타이를 사용한 경우로서, 총 4개의 바벨형상의 전단벽 실험체를 제작하고 일정 축력 아래에서 반복하중 실험을 통하여 그 성능을 평가한다. 콘크리트 공칭강도의 10%의 일정축력 작용상태에서 횡방향 반복가력을 실시하여 구조성능을 평가한다. 실험 결과 전단벽의 경계부재내 시공성 개선을 위해 제안된 사각나선근과 기계적 정착장치를 사용함으로써 재래의 보강방법과 거의 동등한 구조성능을 확보할 수 있는 것으로 나타났다. 또한 띠철근의 직경이 크고 횡보강근의 체적비가 다소 높은 SW-Hh시험체가 항복 이후 균열이 닫힌 다음 강성이 높아짐으로 인하여 전체적인 소산에너지 면적이 다른 시험체에 비하여 높게 나타났으나 최대강도 도달 이후 내력이 다소 급격히 저하되는 것으로 나타나 강도와 연성의 확보측면에서 횡보강근의 체적비와 함께 간격에 대한 고려가 필요한 것으로 판단된다.