• Title/Summary/Keyword: conventional brace

Search Result 39, Processing Time 0.021 seconds

Experimental and numerical study of a proposed steel brace with a localized fuse

  • Parsa, Elham;Ghazi, Mohammad;Farahbod, Farhang
    • Structural Engineering and Mechanics
    • /
    • 제84권2호
    • /
    • pp.269-283
    • /
    • 2022
  • In this paper, a particular type of all-steel HSS brace members with a locally reduced cross-sectional area was experimentally and numerically investigated. The brace member was strengthened against local buckling with inner and outer boxes in the reduced area. Four single-span braced frames were tested under cyclic lateral loadings. Specimens included a simple steel frame with a conventional box-shaped brace and three other all-steel reduced section buckling-restrained braces. After conducting the experimental program, numerical models of the proposed brace were developed and verified with experimental results. Then the length of the proposed fuse was increased and its effect on the cyclic behavior of the brace was investigated numerically. Eventually, the brace was detailed with a fuse-to-brace length of 30%, as well as the cross-sectional area of the fuse-to-brace of 30%, and the cyclic behavior of the system was studied numerically. The study showed that the proposed brace is stable up to a 2% drift ratio, and the plastic cumulative deformation requirement of AISC (2016) is easily achieved. The proposed brace has sufficient ductility and stability and is lighter, as well as easier to be fabricated, compared to the conventional mortar-filled BRB and all-steel BRB.

브레이스 마운팅 결합부의 피로 수명에 관한 실험적 연구 (An Experimental Study on Fatigue Life of Brace Mounting Joint)

  • 김동우
    • 한국생산제조학회지
    • /
    • 제7권3호
    • /
    • pp.104-109
    • /
    • 1998
  • This document is a experimental study on fatigue life of brace mounting weld joint. A brace is used to put sub-frame together on the main frame with high strength bolts. It has low fatigue life so a patch is in need for improving a fatigue characteristics of welded joint in brace mounting This paper presents the most pertinent patch size for truck. For this, a critical stress is computed at the point of fatigue crack occurred on truck frame by finite Element Analysis. Using by this critical stress. Designers are able to determin whether fatigue crack is occurred and are able to select a pertinent patch type. And then, with a selected patch type, structural joint stiffness was estimated to compare to the conventional and other patch type or brace mounting Finally, fatigue test were performed to prove a suitability of selected prototype compare with the conventional and other patch type or brace mounting.

지진응답 제어를 위한 MR-토글 가새 시스템의 실험적 연구 (Experimental Study on the MR-Toggle Brace System for Vibration Control)

  • 민경원;이명규;강상훈;이상현;황재승
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.644-651
    • /
    • 2005
  • The purpose of this paper is to compare the control effect of toggle brace system having amplifying displacement mechanism with that of conventional brace system when the identical MR damper is applied to each system. The force-displacement and lone-velocity relationships of MR damper are obtained using harmonic load test and the analytical model for MR damper is presented. White noise excitation tests of a single degree of freedom system with MR-toggle brace system and MR-chevron system are conducted and the transfer functions of the systems are compared. Test results show that the control effect of the toggle system is superior to that of the conventional brace system.

  • PDF

The cyclic behavior of steel-polyoxymethylene composite braces

  • Demir, Serhat
    • Structural Engineering and Mechanics
    • /
    • 제70권5호
    • /
    • pp.591-600
    • /
    • 2019
  • Steel tubular buckling controlled braces are well known as being simple, practical and cost-effective lateral force resisting systems. Although these system features have gained the attention of the researchers over the last decade, steel tubular buckling controlled braces currently have limited application. Indeed, only a few steel tubes tightly encased within each other exist in the steel industry. In this paper, a new and practical design method is proposed in order to better promote the widespeared application for current steel tubular buckling controlled brace applications. In order to reach this goal, a holed-adapter made with polyoxymethylene adaptable to all round and square steel sections, was developed to use as infiller. The research program presents designing, producing and displacement controlled cyclic loading tests of a conventional tubular brace and a buckling controlled composite brace. In addition, numerical analysis was carried out to compare the experimental results. As a result of the experimental studies, buckling was controlled up to 0.88 % drift ratio and the energy dissipation capacity of the conventional tubular brace increased 1.46 times due to the proposed design. The main conclusion of this research is that polyoxymethylene is a highly suitable material for the production of steel tubular buckling controlled braces.

Structural behavior of conventional and buckling restrained braced frames subjected to near-field ground motions

  • Guneyisi, Esra Mete;Ameen, Nali
    • Earthquakes and Structures
    • /
    • 제7권4호
    • /
    • pp.553-570
    • /
    • 2014
  • In this study, nonlinear dynamic analyses were performed in order to evaluate and compare the structural response of different type of moment resisting frame buildings equipped with conventional braces (CBs) and buckling restrained braces (BRBs) subjected to near-field ground motions. For this, the case study frames, namely, ordinary moment-resisting frame (OMRF) and special moment-resisting frame (SMRF) having two equal bays of 6 m and a total height of 20 m were utilized. Then, CBs and BRBs were inserted in the bays of the existing frames. As a brace pattern, diagonal type with different configurations were used for the braced frame structures. For the earthquake excitation, artificial pulses equivalent to Northridge and Kobe earthquake records were taken into account. The results in terms of the inter-story drift index, global damage index, base shear, top shear, damage index, and plastification were discussed. The analysis of the results indicated a considerable improvement in the structural performance of the existing frames with the inclusion of conventional and especially buckling-restrained braces.

조립형 프리캐스트 콘크리트 보강재를 가지는 비좌굴가새의 이력특성 (Hysteresis Characteristics of Buckling Restrained Brace with Precast RC Restraining Elements)

  • 신승훈;오상훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권1호
    • /
    • pp.72-84
    • /
    • 2016
  • 종래 브레이스시스템은 횡력저항 및 층변위제어에 효율적이며 골조물량 감소에 따른 경제성이 향상되어 일반적인 강구조 횡력저항시스템으로 적용되고 있다. 그러나 압축측에서 항복응력에 도달하기 전 가새의 좌굴이 발생하여 충분한 내력을 발휘하지 못하고, 내력열화형의 이력거동으로 불안정상태가 된다. 좌굴에 의한 내력저하 개선시스템으로 중심재를 구속하여 좌굴방지가 가능한 비좌굴가새는 심재의 항복 이후에도 안정적인 이력특성을 나타내어 종래 브레이스에 비하여 에너지흡수능력이 우수하다. 최근 10년간 미국, 일본 및 대만에서 매우 다양한 형상의 비좌굴가새가 제안되었으나, 기존의 실험연구에서는 그 형상이 매우 제한적인 경향을 보이고 있다. 본 연구에서는 조립형 Precast RC 보강재를 가지는 비좌굴가새를 제작하고 이력특성을 평가하기 위한 부재실험을 수행하였다. 또한 실험결과를 AISC(2005)의 요구조항과 비교하였다.

토글 가새-MR감쇠기 시스템의 제진성능평가 (Performance evaluation of the toggle brace-MR damper system for vibration control)

  • 이상현;황재승;민경원;이명규
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2005년도 학술발표회 논문집
    • /
    • pp.421-428
    • /
    • 2005
  • In this paper, the performance of a toggle brace-MR damper system is evaluated for the control of the structure excited by earthquake load and the non-linearity of the toggle system is investigated. Considering that the control force of MR damper described by Bingham model is a function of velocity, velocity amplification factor by toggle brace system is calculated and the effect of toggle configuration on the amplification factor is also evaluated. Numerical results show that the control performance can be largely enhanced using toggle brace system especially for the case that the MR damper installed with conventional brace system such as Chevron and diagonal cannot provide enough control force under severe earthquake load.

  • PDF

MR감쇠기를 장착한 토글가새시스템을 이용한 건축구조물의 지진응답제어 (Seismic Response Control of a Building Structure Using Toggle-Brace System with an MR Damper)

  • 이상현;황재승;민경원;이명규
    • 한국전산구조공학회논문집
    • /
    • 제19권3호
    • /
    • pp.239-245
    • /
    • 2006
  • 본 연구에서는, 지진하중에 의해 구조물에 발생하는 진동을 제어하기 위하여 토글 시스템의 비선형성을 연구하고, 자기유변유체(MR) 감쇠기를 장착한 토글 가새시스템의 성능을 평가하였다. Bingham 모델로 표현되는 MR감쇠기의 제어력이 속도의 함수인 점을 고려하여, 토글 가새시스템에 의한 속도증폭계수를 계산하였고 토글 형태에 대한 증폭계수효과를 평가하였다. 특히 강한 지진하중에서 쉐브론과 대각가새 등의 전형적인 가새시스템에 장착된 MR감쇠기가 충분한 응답감소효과를 제공하지 못하는 경우에, 토글 가새시스템을 사용하여 제어성능을 크게 강화시키는 것을 수치해석 결과를 통하여 확인하였다.

대각선 철골 중심가새골조의 지질동하에서의 동적불안정 거동 (Dynamic Instability of Diagonally Braced Steel Frames under Seismic Excitation)

  • 김정재;이철호
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 가을 학술발표회 논문집
    • /
    • pp.288-295
    • /
    • 2004
  • Concentrically braced steel frames are considered as being quite pone to soft-story response due to the degradation in brace compressive resistance after buckling under severe ground motions. When combined with the system P-Delta effects, collapse of the concentrically brsced frames by dynamic instability becomes highly probable. In this stidy, a new, relatively simple dynamic instability coefficient was proposed for diagonally braced steel flames by explicitly considering the strength degradation of the brace after buckling. Nonlinear dynamic analysis results showed that the dynamic instability coefficient proposed in this study predicted collapse limit state more consistently than the conventional one which ignores the strength degradation of the brace.

  • PDF

Local and global buckling condition of all-steel buckling restrained braces

  • Mirtaheri, Seyed Masoud;Nazeryan, Meissam;Bahrani, Mohammad Kazem;Nooralizadeh, Amin;Montazerian, Leila;Naserifard, Mohamadhosein
    • Steel and Composite Structures
    • /
    • 제23권2호
    • /
    • pp.217-228
    • /
    • 2017
  • Braces are one of the retrofitting systems of structure under earthquake loading. Buckling restrained braces (BRBs) are one of the very efficient braces for lateral loads. One of the key needs for a desirable and acceptable behavior of buckling-restraining brace members under intensive loading is that it prevents total buckling until the bracing member tolerates enough plastic deformation and ductility. This paper presents the results of a set of analysis by finite element method on buckling restrained braces in which the filler materials within the restraining member have been removed. These braces contain core as the conventional BRBs, but they have a different buckling restrained system. The purpose of this analysis is conducting a parametric study on various empty spaces between core and restraining member, the effect of friction between core and restraining member and applying initial deformation to brace system to investigate the global buckling behavior of these braces. The results of analysis indicate that the flexural stiffness of restraining member, regardless of the amount of empty space, can influence the global buckling behavior of brace significantly.