• Title/Summary/Keyword: controlled-stress

Search Result 915, Processing Time 0.028 seconds

UV-B-Induced Changes in Carbohydrate Content and Antioxidant Activity in Rice Seedling

  • Sung Jwa-Kyung;Lee Su-Yeon;Park So-Hyun;Jang Byoung-Choon;Lee Sang-Min;Lee Yong-Hwan;Choi Du-Hoi;Song Beom-Heon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.50 no.2
    • /
    • pp.84-90
    • /
    • 2005
  • The effects of UV-B radiation on the seedling growth, carbohydrate metabolism and antioxidants activities of rice (Oryza sativa L.) were investigated under environmentally controlled chamber. Supplementary UV­B radiation reduced dry matter as well as leaf area, there­fore, relative growth rates (RGR) of seedlings were decreased by up to half compared to control. Photosynthetic products such as soluble sugars and starch were rapidly and significantly reduced by within 1 day of enhanced UV-B radiation due to the inhibition and degradation of photosynthetic processes and thylakoid membrane integrity. In our study, nonstructural carbohydrate levels were proved to be a main indicator on UV-B­induced stress. The behavior of SOD, CAT, APX and POD activities was monitored in the leaves of rice seedlings subjected to UV-B radiation. Under UV-B treatments, SOD activity was initially increased, whereas CAT and POD activities were slowly and slightly increased. However, APX activity showed no presumable results with an increase of UV-B dose. In leaves of rice seedlings, supplementary UV-B radiation caused an increase in free putrescine and spermidine, however spermine remained unaltered, although 24-hrs UV-B treatment slightly increased. This result presumes that an excess UV-B dose may induce ethylene biosynthesis (senescence) rather than polyamine biosynthesis (defense).

Effects of heat treatment and Co addition on the magnetic properties of FeCoBSi thin film (FeCoSiB 자성박막의 자기적 특성에 미치는 Co 및 열처리의 영향)

  • 신현수;양성훈;장태석;박종완
    • Journal of the Korean Vacuum Society
    • /
    • v.9 no.4
    • /
    • pp.389-393
    • /
    • 2000
  • Effects of Co addition and heat treatment on the magnetic properties of Fe-Si-B thin films were investigated. The compositions of metalloids, i.e, B and Si, in the alloys were kept 10 at.% each. Heat treatments were carried out in the temperature range from 100 to $300^{\circ}C$ for up to 60 min. Amorphous thin films of FeCoSiB were deposited on the water-cooled substrates by dc magnetron sputtering. The composition of thin films was controlled by placing proper number of pellets of alloying elements and analyzed by ICP, resulting in $Fe_{80-X}Co_ XB_{10}Si_{10}$ (X=8~18 at.%). Saturation magnetization of the alloys increased as Co concentration increased up to 10 at.% and then decreased with further increase of Co concentration. However, coercive force of the films decreased with the increase of Co concentration. Furthermore, the coercive force was also reduced by the annealing due to the residual stress relief.

  • PDF

A Study on the Effects on Low Cycle Fatigue Life of a High Pressure Turbine Nozzle due to the Perturbation of Crystal Orientation of Grain of DS Materials (일방향 응고 재료의 결정립 성장 방향 섭동이 고압터빈 노즐 저주기 피로 수명에 미치는 영향에 대한 연구)

  • Huh, Jae Sung;Kang, Young Seok;Rhee, Dong Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.7
    • /
    • pp.653-658
    • /
    • 2016
  • High pressure components of a gas turbine engine are generally made of nickel-base superalloys, using precision casting process due to complicated geometries with intricate channels and cooling holes. Turbine components manufactured from directionally solidified and single crystal materials have columnar grains; however, it is found that the crystals do not grow in its preferred direction, although the orientation can be controlled. This anisotropy can lead to the variations of elastic and Hill's parameters in constitutive equations, and they alter stress distributions and the low cycle fatigue life. We aims to evaluate the effects of perturbed crystal orientations on the structural integrity of a directionally solidified nozzle using low cycle fatigue life. We also attempt to show the necessity for the control of allowed manufacturing errors and stochastic analysis. Our approaches included conjugate heat transfer and structural analysis, along with low cycle fatigue life assessment.

Low Cycle Fatigue Behavior of Alloy617 Weldment at 850℃ (850℃에서의 Alloy 617 용접재의 저사이클 피로 특성)

  • Hwang, Jeong Jun;Kim, Seon Jin;Kim, Woo Gon;Kim, Eung-Seon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.3
    • /
    • pp.193-198
    • /
    • 2017
  • Alloy 617 is one of the primary candidate materials to be used in a very high temperature reactor (VHTR) system as an intermediate heat exchanger (IHX). To investigate the low cycle fatigue behavior of Alloy 617 weldments at a high temperature of $850^{\circ}C$, fully reversed strain-controlled fatigue tests were conducted with the total strain values ranging from 0.6~1.5%. The weldment specimens were machined using the weld pads fabricated with a single V-grove configuration by gas tungsten arc welding (GTAW) process. The fatigue life is reduced as the total strain range increases. For all testing conditions, the cyclic stress response behavior of the Alloy 617 weldments exhibited the initial cyclic strain hardening phenomenon during the initial small number of cycles. Furthermore, the overall fatigue cracking and the propagation or cracks showed a transgranular failure mode.

Analysis of Heating Load of a Naturally Ventilated Broiler House using BES Simulation (BES 기법을 이용한 자연환기식 육계사의 난방에너지 분석)

  • Hong, S.W.;Lee, I.B.;Hong, H.K.;Seo, I.H.;Hwang, H.S.;Bitog, J.P.;Yoo, J.I.;Kwon, K.S.;Ha, T.H.;Kim, K.S.
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.50 no.1
    • /
    • pp.39-47
    • /
    • 2008
  • Most of the broiler houses in Korea have experienced problems on controlling the environmental conditions such as suitability, stability and uniformity of rearing condition inside the broiler house. It is very critical which if not properly controlled, would cause serious stress on the chickens. It is therefore urgent to develop optimum designs of naturally ventilated broiler house which is appropriate to the four seasons of Korea. Field experiment for this matter is very difficult to conduct due to the unpredictable and uncontrollable weather condition. In this study, the heating load of a naturally ventilated broiler house was calculated using TRANSYS 15 BES program while internal climate and thermal condition were computed using Fluent 6.2. The computed resulted of the conventional ventilation system (A) and upgraded ventilation system (B) (Seo et al, 2007) were compared with each other for cold season. The results of the Building Energy Simulation(BES) indicated that the system B, the upgraded ventilation system made 8% lower total heating load and 47% lower at only the broiler zone compared to the conventional broiler house. Considering the entire broiler house, the existence of middle ceiling made the heating energy 11% lower required than without middle ceiling. Accordingly, the system B with middle ceiling was found to save heating energy by 20% in average. This study showed that the BES program can be a very powerful to effectively compute the energy loads of agricultural building while the energy load is very close related to ventilation efficiency.

Indicative Responses of Rice Plant to Atmospheric Ozone

  • Hur, Jae-Seoun;Kim, Pan-Gi;Yun, Sung-Chul;Park, Eun-Woo
    • The Plant Pathology Journal
    • /
    • v.16 no.3
    • /
    • pp.130-136
    • /
    • 2000
  • Differences in physiological and biochemical responses between sensitive and tolerant rice cultivars to ozone were investigated to develop reliable indications of early ozone damage. Three Korean local rice cultivars -sen-sitive cultivar Dongjin (DJ), moderately tolerant cultivar Hwayeong (HY) and tolerant cultivar Ilmee (IM) were exposed to ozone at the concentrations of 100 nl $\textrm{l}^{-1}$ or 200 nl $\textrm{l}^{-1}$ , 8 h per day for 10 days in a controlled-environment fumigation chamber. The rice cultivars seemed to be endurable to ozone stress at the concentration of 100 nl $\textrm{l}^{-1}$ which is frequently monitored during the growing season in summer. However, severe damage was induced and differential sensitivity was clearly noted among the rice cultivars at the higher ozone concentration. Activation of the glutathion (GR) -ascorbate peroxidase (APX) cycle was likely to be responsible for protection of rice plants against ozone exposure, relating difference in sensitivity of rice cultivars to ozone. Photosynthetic activity appeared to be one of sensitive responses, for which chlorophyll fluorescence and leaf greenness can together provide a very reliable index, a degree of photosynthetic damages by ozone. Formation of malondialdehyde (MDA) was also considered as an indication that can differentiate cultivars sensitivity to ozone. However, the changes in polyamines and total phenolics were not consistent with exposed ozone concentrations and/or ozone sensitivity of the cultivars. The behavior of polyamines and phenolics in the damaged plants at high ozone levels could be interpreted as an indication of ozone injury rather than activation of additional protection mechanisms scavenging active oxygen species formed by ozone. Several responses triggered by ozone could explain the differential sensitivity of the rice cultivars and be used as reliable indications of relative ozone damage to rice plant.

  • PDF

Computer aided failure prediction of reinforced concrete beam

  • Islam, A.B.M. Saiful
    • Computers and Concrete
    • /
    • v.25 no.1
    • /
    • pp.67-73
    • /
    • 2020
  • Traditionally used analytical approach to predict the fatigue failure of reinforced concrete (RC) structure is generally conservative and has certain limitations. The nonlinear finite element method (FEM) offers less expensive solution for fatigue analysis with sufficient accuracy. However, the conventional implicit dynamic analysis is very expensive for high level computation. Whereas, an explicit dynamic analysis approach offers a computationally operative modelling to predict true responses of a structural element under periodic loading and might be perfectly matched to accomplish long life fatigue computations. Hence, this study simulates the fatigue behaviour of RC beams with finite element (FE) assemblage presenting a simplified explicit dynamic numerical solution to show computer aided fatigue behaviour of RC beam. A commercial FEM package, ABAQUS has been chosen for this complex modelling. The concrete has been modelled as a 8-node solid element providing competent compression hardening and tension stiffening. The steel reinforcements are simulated as two-node truss elements comprising elasto-plastic stress-strain behaviour. All the possible nonlinearities are duly incorporated. Time domain analysis has been adopted through an automatic Newmark-β time incremental technique. The program consists of twelve RC beams to visualize the real behaviour during fatigue process and to obtain the reliability of the study. Both the numerical and experimental results indicate a redistribution of stresses along the time and damage accumulation of beam which severely affect the serviceability and ultimate capacity of RC beam. The output of the FEM analysis demonstrates good match with the experimental consequences which affirm the efficacy of the computer aided model. The controlled fatigue damage evolution at service fatigue load limits makes the FE model an efficient tool in predicting high cycle fatigue behaviour of RC structures.

An Empirical Analysis on the Fiscal Crisis of Local Governments in Korea (지방자치단체의 '재정위기'에 대한 실증분석)

  • 김범식;박원석;송영필
    • Journal of the Korean Regional Science Association
    • /
    • v.15 no.1
    • /
    • pp.75-92
    • /
    • 1999
  • In this study, the present state of fiscal crisis for local governments after IMF is analyzed, firstly. its implications Characteristics of structural reform of finance after IMF bailout in Korea are examined, secondly. Since Korea was shocked by the currency crisis at the end of 1997, its local governments have also faced fiscal difficulties. The Depression of national and local economies led to decreases in tax revenues of local governments. And these shrunken revenues led to their expenditure cuts. Many investment plans were curtailed, and ordinary expenditures were also reduced sharply. The negative influences of the currency crisis on local government's finances can be examined in terms of fiscal revenue, fiscal spending, and debt burden. As a result many local governments are now experiencing fiscal stress, and some of them are even faced with fiscal crisis although the possibility of extreme measures, such as moratoriums or bankruptcies, is very slim. This is due in part to the weight of debt in local governments' budgets having remained small since the debt of local governments has been controlled by the central government. Another reason is that, central government, which functions as a lender of last resort for the local governments, will pay the debt for them. Also, without a legal system which stipulates the adjudication of bankruptcy for municipalities in Korea, local Korean governments have no legal right to declare bankruptcy. Although not a single municipality has fallen into insolvency, yet, this trend will continue to deepen as the recession continues and may lead to a situation where manu local governments fall into virtual bankruptcy in the near future, and its effects on society, as a whole, will be serious. Therefore, measures to prevent and overcome such an extreme situation are necessary, but both short-and long-term policies should be to cope with the current fiscal crisis and to prevent the deepening of the current situation.

  • PDF

The Constant Output Power Control of SSRT FB DC-DC Converter by an Improved Phase-shift Control (개선된 위상 천이 제어에 의한 소프트 스위칭 공진형 FB DC-DC 컨버터의 정출력 제어)

  • 신동률;조용길;김동완;우정인
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.5
    • /
    • pp.27-35
    • /
    • 2000
  • This paper deals with a control strategy for constant output power of SSRT(Soft Switching Resonant Type) FB(Full Bridge) DC-DC converter by an improved phase shift controller. When the FB DC-DC converter for the high density and the high effect control is operated in high speed switching, the switching loss and switching stress of the switching devices are increased. So, the soft switching method, which has the phase shift control with the digital I-PD controller, must be use in order to reduce its. And the output voltage that controlled by the digital I-PD controller tracks a reference without steady state error in variable input voltage. The validity of control strategy that proposed is verified from simulation results and experimental results by the DSP(TMS320C32).

  • PDF