• Title/Summary/Keyword: control system and monitoring system development

Search Result 944, Processing Time 0.038 seconds

An Implementation of Remote Monitoring and Control System using CMOS Image sensor (CMOS 이미지 센서를 이용한 원격지 화상 감시 및 제어 시스템 구현)

  • Choi, Jae-Woo;Ro, Bang-Hyun;Lee, Chang-Keun;Hwang, Hee-Young
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.653-656
    • /
    • 2003
  • We have designed embedded web sewer system and ported Linux operating system version 2.4.5 at our system. And then We implemented to control and monitor widely separated hardware and implemented to monitor widely separated image using CMOS image sensor HV7131B. Web server is the Boa web server with General Public License. We designed for this system using of Intel's SA1110 ARM core base processor and connecting input and output device at GPIO port of SA1110. Device driver of General purpose I/O for Embedded Linux OS is designed. And then the application program controlling driver is implemented to use of common gate interface C language. User is available to control and monitor at client PC. This method have benefit to reduce the Expenditure of hardware design and development time against PC base system and have various and capacious application against firmware base system.

  • PDF

Knowledge-Based Control via the Internet

  • Tang, Kok-Zuea;Goh, Han-Leong;Tan, Kok-Kiong;Lee, Tong-Heng
    • International Journal of Control, Automation, and Systems
    • /
    • v.2 no.2
    • /
    • pp.207-219
    • /
    • 2004
  • This paper presents the development of a knowledge-based control system operating via the Internet. With the synergy provided by the Internet, the central expert controller with its knowledge-base has the potential to serve a multitude of front-end clients located anywhere in the world provided they have Internet access. In this way, the operational span of the knowledge-based control system can be expanded to virtually anyplace within the reach of the Internet. This configuration has positive implications in improving the efficiency of distributed operations, thereby enabling plantwide optimization and costs savings. Datasocket technology is adopted to facilitate a more efficient data exchange between the knowledge-based central server and the front-end clients. A specific application in the remote monitoring and fault diagnosis of machines using the proposed control configuration is presented in the paper.

Development of Optimal Control System for Lighting and HVAC(Heating, Ventilation, Air Conditioning) Using Energy Saving (에너지 절감용 조명 및 공조기기 최적제어 시스템 개발)

  • Jang, Woo-Sung;Song, Yeoung-Seok;Cho, Byung-Lok;Cho, Seok-Hwan
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.5
    • /
    • pp.1029-1036
    • /
    • 2018
  • This paper is a study on the development of optimal control system for lighting and air conditioning equipment to save the energy in campus environment. In the case of controling system developed through this research, lighting and air conditioner are controlled by both information on the number of people entering and leaving the room through the motion sensor and image processing, and the information on temperature and humidity. In addition, energy saving is enabled by the results that are controlled through data integration monitoring and command execution functions according to the control signals.

Development of Wireless Communication Based Operation State Monitoring System for Open Rack Vaporizer (무선 통신 기반 해수식 기화기 운영 상태 모니터링 시스템 개발)

  • Yoo, Seung-Yeol;Joen, Ming-Sung;Lee, Jae-Chul;Kang, Dong-Hoon;Kim, Dong-Goen;Lee, Soon-Sup
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.59 no.5
    • /
    • pp.280-287
    • /
    • 2022
  • An open rack vaporizer is a facility that vaporizes liquefied natural gas using sea water. When a vaporization efficiency of the open rack vaporizer decreases, liquefied natural gas can leak, which can cause great damage to the facility. Operators have to monitor the operation state of the facility in real-time to prevent the accident. However, operators have visited the site and have checked the state by looking at the value of sensors installed in the open rack vaporizer through indicators. For the safe operation of the open rack vaporizer, a monitoring system is needed to monitor the operation state of the open rack vaporizer in real-time without the need for operators to visit the site. In this paper, we developed a long term evolution based monitoring system to monitor the operation state of the open rack vaporizer. The developed system can monitor the real-time operation state of the open rack vaporizer at a control center far from the facility. For the system development, data transmission infrastructure using long term evolution was built. Afterwards a software was developed to monitor the operation state of the open rack vaporizer in real-time using the transmitted data. Finally, performance evaluation was conducted to confirm that the developed system operated successfully without data transmission delay or data missing.

Development of Long-Term Storage Technology for Chinese Cabbage - Physiological Characteristics of Postharvest Freshness in a Cooler with a Monitoring and Control Interface

  • Lim, Ki Taek;Kim, Jangho;Chung, Jong Hoon
    • Journal of Biosystems Engineering
    • /
    • v.39 no.3
    • /
    • pp.194-204
    • /
    • 2014
  • Purpose: The aim of this study was to develop long-term storage technology for Chinese cabbage in order to extend the period of availability of freshly harvested products. The scope of the paper deals with the use of a cooler with a remote monitoring and control interface in conjunction with use of packaging film. Methods: A cooler with a real time monitoring system was designed as a low-temperature storage facility to control temperature and relative humidity (RH). The effects of storage in high-density polyethylene (HDPE) plastic boxes, 3% chitosan dipping solution, polypropylene film (PEF) with perforations, and mesh packaging bags on physiological responses were investigated. The optimal storage temperature and humidity for 120 days were below $0.5^{\circ}C$ and 90%, respectively. Physiological and biochemical features of cabbage quality were also analyzed: weight loss, texture, and sugar salinity, chlorophyll, reducing sugar, and vitamin C contents. Results: The cooler with a remote monitoring and control interface could be operated by an HMI program. A $0.5^{\circ}C$ temperature and 90% humidity could be remotely controlled within the cooler for 120 days. Postharvest freshness of Chinese cabbages could be maintained up to 120 days depending on the packaging method and operation of the remote monitoring system. In particular, wrapping the cabbages in PEF with perforations resulted in a less than a 5% deterioration in quality. This study provides evidence for efficient performance of plastic films in minimizing post-harvest deterioration and maintaining overall quality of cabbages stored under precise low-temperature conditions with remote monitoring and a control interface. Conclusions: Packaging with a modified plastic film and storage in a precisely controlled cooler with a remote monitoring and control interface could slow down the physiological factors that cause adverse quality changes and thereby increase the shelf life of Chinese cabbage.

Development of train speed controller for EMU using servo-controller

  • Lee, Su-Gil;Han, Seong-Ho;Han, Young-Jae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.178.1-178
    • /
    • 2001
  • The ATO(Automatic Train Operation) System is used for train operation instead of dreivers. It is interfaced with TCMS(Train Control and Monitoring System) and ATC/TWC system in the train and wayside facilities. In this paper describes configuration of ATO, Specification of ATO hardware, construction of ATO software and the algorithm for automatic train speed regulation in the carborn ATO system. This paper is mainly concerned with the development of the ATO System. The ATO system is used for automatic or driverless operation of a train using various informations from TCMS, ATC, TWC. In this paper, the general architecture of the ATO system, implementation of ATO application software and the algorithm using servo-controller for automatic train speed controller.

  • PDF

A Study on the development of automatic control programming for projection machine (사출기의 자동제어 프로그램 개발에 관한 연구)

  • 김현기;홍용인;이천희
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.1145-1148
    • /
    • 1999
  • In this paper we developed the communication protocol in which can transmitter receive a data and instruction in pressure and control computer. This system can dramatically increase production by maximize by control the error in central unit and monitoring. When developed these pressure automatic control system, it can be automation product in factory and decrease man-power.

  • PDF

Development of Production Information System for Real-time Operation Brass-Pipe Production Machine (동파이프 생산 설비가동의 실시간 생산정보시스템 개발)

  • 정영득;김영균;박주식;강경식
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.27 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • This study intend to make easy modification, even if there is a new job or structure change, by modularizing program and computerize and automation of production control management used in CIM. under the condition where manager control production on the job-site, for increasing connection with other operation and management on the computer by monitoring center computer, recognizing information by computer is needed, it is possible by converting transaction. So this study goal is to make delivery control and order control fast and accurate by finding dynamic history of machine and production information in enterprise without input production and quality information by themselves with quality information system. So production increase and quality improvement are possible by diminishing manager's and producer's work with the result of the study combining POP and CIM, after that, in e-business and m-business period that every enterprise must pass, customer satisfaction and sales promotion are possible with employee's computerizing minds. these study result also can knowledge process condition with theoretical class and have a power in finding a solution with foundation of theoretical knowledge.

Development of LVDT-Based Measuring System of the Cylinder Liner Wear for Marine Diesel Engines and Its Performance Evaluation (LVDT를 이용한 선박용 디젤 엔진의 실린더 라이너 마모 계측시스템 개발 및 성능평가)

  • Ha, Yun-Su
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.829-834
    • /
    • 2011
  • This paper introduces a new system which measures abrasion quantity of cylinder liners of large-scale marine diesel engines. The proposed system consists of three parts; measurement part where an LVDT, a temperature sensor, a camera and LED for lighting control are installed, monitoring part which accomplishes measurement command transmission and monitoring based on PC or notebook, and master control part which controls the measurement part and transfers measurement data to the monitoring part. The accuracy of the developed system is compared with that of an internal micrometer with 1/100 mm accuracy.

Development of Monitoring System for Polishing Robot Based on Web

  • Hong, Chang-Woo;Go, Seok-Jo;Lee, Min-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.57.4-57
    • /
    • 2001
  • Polishing a die that has free-form surfaces is a time-consuming and tedious job, and requires a considerable amount of high-precision skill. Some workers tend to gradually avoid the polishing work because of the poor working conditions caused by dust and noise. In the our previous study, an automatic polishing system was developed to reduce the polishing time and cope with the shortage of skilled workers. And, to operate the polishing robot system from remote sites, communication network was constructed and monitoring programs (a server program and a client program)) were developed. However, to monitor polishing process in remote sites, users have to install monitoring programs in a client PC. Thus, user can only operate the polishibg system ...

  • PDF