• Title/Summary/Keyword: control surfaces

Search Result 1,217, Processing Time 0.029 seconds

An Experimental Study of Coanda Effect on the Flapped Control Surfaces (콴다효과를 응용한 플랩이 달린 고양력 날개장치에 대한 실험적 연구)

  • 안해성;김효철
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.40 no.5
    • /
    • pp.10-16
    • /
    • 2003
  • To investigate the jet effect on circulation control, a segment of model was prepared and inserted horizontally across the test section of the cavitation tunnel. The hydrodynamic forces acting on the model were measured under the 2 dimensional flow behavior. Circulation flow control requires higher flow rate of water jet than boundary layer control does. Jet injection is effective in increasing lift coefficient and the increments reach to 160% in a certain combination of parameters such as an angle of attack, jet flow rate and flap angle. The blown water jet not only reduces form drag but also thrust effect, which is sometimes greater than the form drag in specific conditions.

Implementation and Application of the Control Surface Deflection Angle measuring device for UAV using Potentiometer (전위차계를 이용한 무인항공기 조종면 변위 측정 장치 구현 및 적용)

  • Kim, Ji-Chul;Choi, Il-Gyu;Gong, Sung-Chul;Cheon, Dong-Ik;Lee, Sangchul;Oh, Hwa-Suk;Kang, Min-young
    • Journal of Aerospace System Engineering
    • /
    • v.3 no.3
    • /
    • pp.13-16
    • /
    • 2009
  • Aircraft flight control surfaces which are one of the most important elements of safety allow a pilot to adjust and control the aircraft's flight attitude. This paper is described of the control surface deflection angle measuring device. Data analysis through ground test and flight test can provide reliability of this device using the present system. It is also shown that measuring system is capable of detecting failure of control surfaces.

  • PDF

A STUDY OF THE BOND STRENGTHS OF COMPOSITE RESIN TO DENTIN SURFACES PREPARED WITH MICROABRASIVE (Microabrasive로 처리한 상아질표면에 대한 복합레진의 결합강도에 관한 연구)

  • Choi, Kyoung-Kyu;Min, Byung-Soon
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.61-75
    • /
    • 1997
  • The bond strengths of composite resin to tooth dentin vary with the methods of cavity preparation and surface treatment. Recent developments in techniques of dentinal surface treatment have renewed interest in microabrasive as a means of tooth preparation, The purpose of this study was to determine the effects of a new method of cavity preparation on the bond of composite resin to dentin. Freshly extracted 144 healthy human third molars were used in this study. The dentin surfaces prepared with #600 SiC abrasive paper were divided into control and air abrasion groups according to the method of dentin surface preparation using different combinations of delivery pressure, time, and acid etching. The shear bond strengths were measured after the composite resin (Clearfil Photo Bright) was bonded to prepared dentin surfaces by light-curing using a dentin bonding system (All-bond 2), In addition, the average surface roughness was measured to investigate the effect of differently prepared dentin surfaces on the shear bond strengths. The surface changes of prepared dentin and the debonded dentin surfaces were observed with SEM (S-2300, Hitachi Co., Japan). The following results from this-study were obtained ; 1. There was no significant difference of shear bond strengths according to the changes of delivery pressure and time. 2. The shear bond strengths were lower than the control in the air abraded-only groups, but those of the additional acid-etched groups were higher than the control. 3. The shear bond strengths to all air-abraded surfaces were increased by acid etching. 4. The correlation between shear bond strengths and surface roughness was not certain, although the mean surface roughness of all air-abraded surfaces has increased evidently while it has slightly decreased for additional acid etching. 5. On SEM examination, the dentinal tubules were almost occluded in the air abraded-only groups, but those were opened in the additional acid-etched groups. 6. The debonded surfaces were showed adhesive failure mode in the air abraded- only groups, while those were showed mainly the mixed and cohesive failure mode in the additional acid-etched groups. These results suggest that the layer produced during cavity preparation or surface treatment with air abrasion must be removed for maximum bond strength of composite resin to dentin.

  • PDF

Modeling of blend surfaces by Non Uniform B-spline surface patches (Non Uniform B-spline(NUB) 곡면에 의한 블랜드 곡면의 모델링)

  • Yoo, Woo-Sik;Jeong, Hoi-Min
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.26 no.2
    • /
    • pp.95-100
    • /
    • 2000
  • Presented in this paper is a scheme for constructing ball rolling blends of a non-uniform B-spline surface(NUBS) patches. Ball rolling blending is a popular technique for blending between parametric surfaces. Along the "common edge" of a pair of "base surfaces" to be blended, a sequence of "ball positions" is sampled. The radius of the ball may vary along the line. At each sampling point, a ball center point and a pair of ball contact points are computed by applying a Jacobian inversion method. Using ball contact points, the constructing scheme of blend NUBS patches consists three steps; 1) determination of intermediate control vertices; 2) determination of boundary vectors; 3) determination of B-spline control vertices. The proposed blending scheme has been tested in a Omega CAM system and found to be working satisfactorily.

  • PDF

Microstructural Change of Implant Surface conditioned with Tetracycline-HCI;SLA and TB surface implant (표면처리 시간에 따른 임플란트 미세구조의 변화;SLA와 TB 표면 임플란트)

  • Woo, Jung-A;Herr, Yeek;Kwon, Young-Hyuk;Park, Joon-Bong;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.4
    • /
    • pp.921-937
    • /
    • 2005
  • Mechanical and chemical methods are the two ways to treat the implant surfaces. By using mechanical method, it is difficult to eliminate bacteria and by-products from the rough implant surface and it can also cause the structural change to the implant surface. Therefore, chemical method is widely used in order to preserve and detoxicate the implant surface more effectively. The purpose of this study is to evaluate the effect of tetracylcline- HCl on the change of implant surface microstructure according to application time. Implants with pure titanium machined surface, SLA surface and $TiO_2blasted$ surface were used in this study. Implant surface was rubbed with sponge soaked in 50mg/ml tetracycline - HCl solution for $\frac{1}{2}$ min., 1min., $1\frac{1}{2}$ min., 2 min., and $2\frac{1}{2}min.$ respectively in the test group and with no treatment in the control group. The sponge was soaked in every 30 seconds. Then, the specimens were processed for scanning electron microscopic observation. Based upon the analysis of photographs by three dentists who are not related with this study, the results were obtained as follows; 1. In the pure titanium machined surfaces, the control specimen showed a more or less rough machined surface composed of alternating positive and negative lines corresponding to grooves and ridges. After treatment, machining line was more pronounced for the control specimens. but in general, test specimens were similar to control. 2. In the SLA surfaces, the control specimen showed that the macro roughness was achieved by large-grit sandblasting. Subsequently, the acid-etching process created the micro roughness, which thus was superimposed on the macro roughness. Irrespective of the application time of 50mg/ml tetracycline - HCl solution, in general, test specimens were similar to control. 3. In the $TiO_2blasted$ surfaces, the control specimen showed the rough surface With small pits. The irregularity of the $TiO_2blasted$ surfaces with 50mg/ml tetracycline - HCl solution was lessened and the flattened areas got wider after 1 minute.

Scanning Tunneling Microscopy (STM)/Atomic Force Microscopy(AFM) Studies of Silicon Surfaces Treated in Alkaline Solutions of Interest to Semiconductor Processing

  • Park, Jin-Goo
    • Journal of the Korean institute of surface engineering
    • /
    • v.28 no.1
    • /
    • pp.55-63
    • /
    • 1995
  • Alkaline solutions such as $NH_4$OH, choline and TMAH (($CH_3$)$_4$NOH) have been introduced in semiconductor wet processing of silicon wafers to control ionic and particulate impurities following etching in acidic solutions. These chemicals usually mixed with hydrogen peroxide and/or surfactants to control the etch rate of silicon. The highest etch rate was observed in $NH_4$OH solutions at a pH in alkaline solutions. It indicates that the etch rate depends on the content of $OH^{-}$ as well as cations of alkaline solutions. STM/AFM techniques were used to characterize the effect of alkaline solutions on silicon surface roughness. In SC1 (mixture of $NH_4$OH : $H_2$$O_2$ : $H_2$O) solutions, the reduction of the ammonium hydroxide proportion from 1 to 0.1 decreased the surface roughness ($R_{rms}$) from 6.4 to $0.8\AA$. The addition of $H_2$$O_2$ and surfactants to choline and TMAH reduced the values of $R_{p-v}$ and $R_{rms}$ significantly. $H_2$$_O2$ and surfactants added in alkaline solutions passivate bare silicon surfaces by the oxidation and adsorption, respectively. The passivation of surfaces in alkaline solutions resulted in lower etch rate of silicon thereby provided smoother surfaces.s.ces.s.

  • PDF

GPU-based Rendering of Blending Surfaces (블렌딩 곡면의 GPU 기반 렌더링)

  • Ko, Dae-Hyun
    • Journal of the Korea Computer Graphics Society
    • /
    • v.13 no.1
    • /
    • pp.1-6
    • /
    • 2007
  • Although free-form surfaces can represent smooth shapes with only a few control points contrary to polygonal meshes, graphics hardware does not support surface rendering currently. Since modern programmable graphics pipeline can be used to accelerate various kinds of existing graphics algorithms, this paper presents a method that utilizes the graphics processing unit (GPU) to render blending surfaces with arbitrary topology fast. Surface parameters sampled on the control mesh and geometric data for local surfaces are sent to the graphics pipeline, and then the vertex processor evaluates the surface positions and normals with these data. This method can achieve very high performance rather than CPU-based rendering.

  • PDF

In vitro study of Streptococcus mutans adhesion on composite resin coated with three surface sealants

  • Kim, Da Hye;Kwon, Tae-Yub
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.1
    • /
    • pp.39-47
    • /
    • 2017
  • Objectives: Although the coating of surface sealants to dental composite resin may potentially reduce bacterial adhesion, there seems to be little information regarding this issue. This preliminary in vitro study investigated the adhesion of Streptococcus mutans (S. mutans) on the dental composite resins coated with three commercial surface sealants. Materials and Methods: Composite resin (Filtek Z250) discs (8 mm in diameter, 1 mm in thickness) were fabricated in a mold covered with a Mylar strip (control). In group PoGo, the surfaces were polished with PoGo. In groups PS, OG, and FP, the surfaces polished with PoGo were coated with the corresponding surface sealants (PermaSeal, PS; OptiGuard, OG; Fortify Plus, FP). The surfaces of the materials and S. mutans cells were characterized by various methods. S. mutans adhesion to the surfaces was quantitatively evaluated using flow cytometry (n = 9). Results: Group OG achieved the lowest water contact angle among all groups tested (p < 0.001). The cell surface of S. mutans tested showed hydrophobic characteristics. Group PoGo exhibited the greatest bacterial adhesion among all groups tested (p < 0.001). The sealant-coated groups showed statistically similar (groups PS and FP, p > 0.05) or significantly lower (group OG, p < 0.001) bacterial adhesion when compared with the control group. Conclusions: The application of the surface sealants significantly reduced S. mutans adhesion to the composite resin polished with the PoGo.

Acquisition and Processing of 3D Data (3차원 데이터의 획득 및 가공)

  • Kim A.H.;Kim Y.S.;Bae C.;Kang W.C.;Kim Y.D.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.286-290
    • /
    • 2003
  • Accurate acquisition of surface geometries such as machined surfaces, biological surfaces, and deformed parts have been very important technique in scientific study and engineering, expecially for system design, manufacturing and inspection. Two camera method keeps accuracy more than double than mechanical method. In this paper, we describe the processes surface data of teeth for automatic processing, transformation that changes to coping data of possible numeric data form and processed inlay teeth. As the result of the Inlay manufacture, which can process with high resolution, therefore we construct the automatic processing system that depends on manual

  • PDF

Effect of Sodium Hyaluronate on Osteoarthrosis in Rabbit Model (골관절증이 유발된 토끼에서 Sodium Hyaluronate의 효과)

  • 이진원;김창환;박종환;최은실;홍정주;박재섭;박재학
    • Biomolecules & Therapeutics
    • /
    • v.7 no.4
    • /
    • pp.347-353
    • /
    • 1999
  • Osteoarthrosis was induced in rabbit knees through resecton of anterior cruciate ligament. Sodium hyaluronate (1%) was administerated into articular space at the dose levels of 0.1 mg/kg once a week using 1ml sylinge and 26G needle for test groups. Saline was administrated for control groups. After 6 and 12 weeks, animals were sacrificed to conduct macroscopic observation and histopathologic examination. The articular lesions were evaluated and test groups were compared with control groups. No significant differencies were showed between test groups and control groups at macroscopic observation in both 6- and 12- week groups. In histopathologic examination, control groups showed higher osteoarthrosis than test groups. The articular surfaces of control groups showed fibrillation, denudation, pannus formation and hypocellularity. The articular surfaces of test groups showed fibrillaton and hypercellularity. These indicate that sodium hyaluronate has inhibitory effects on osteoarthrosis at least in rabbit and could be used for treatment of osteoarthrosis.

  • PDF