• Title/Summary/Keyword: control performance

Search Result 25,093, Processing Time 0.054 seconds

Robust Stability Condition and Analysis on Steady-State Tracking Errors of Repetitive Control Systems

  • Doh, Tae-Yong;Ryoo, Jung-Rae
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.6
    • /
    • pp.960-967
    • /
    • 2008
  • This paper shows that design of a robustly stable repetitive control system is equivalent to that of a feedback control system for an uncertain linear time-invariant system satisfying the well-known robust performance condition. Once a feedback controller is designed to satisfy the robust performance condition, the feedback controller and the repetitive controller using the performance weighting function robustly stabilizes the repetitive control system. It is also shown that we can obtain a steady-state tracking error described in a simple form without time-delay element if the robust stability condition is satisfied for the repetitive control system. Moreover, using this result, a sufficient condition is provided, which ensures that the least upper bound of the steady-state tracking error generated by the repetitive control system is less than or equal to the least upper bound of the steady-state tracking error only by the feedback system.

Indoor Temperature Control of a Heat Pump Based on Model Predictive Control Considering Energy Efficiency (에너지효율을 고려한 모델예측제어에 기초한 열펌프의 실내온도 제어)

  • 조항철;변경석;송재복;장효환;최영돈
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.3
    • /
    • pp.200-208
    • /
    • 2001
  • In indoor temperature control of a heat pump, a reduction in energy consumption is very important. However, most control schemes for heat pumps have focused only on control performance such s settling time and steady-state error. In this paper, the model predictive control (MPC) which includes the energy-related variable in this cost function is proposed. By computing the control signal minimizing this cost function, the trade-off between energy reduction and temperature control performance can be obtained. Since the MPC required the process model, the dynamic mode of a heat pump is also obtained by the system identification technique. Performance of the proposed MPC considering energy efficiency is compared with the two other control schemes. It si shown that the proposed scheme can consume less energy thant hte others in achieving similar control performance.

  • PDF

Determination of Optimal Checkpoint Interval for Real-time Control Tasks Considering Performance Index Function (성능 함수를 고려한 실시간 제어 테스크에서의 최적 체크 포인터 구간 선정)

  • Kwak, Seong-Woo;Jung, Young-Joo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.5
    • /
    • pp.875-880
    • /
    • 2008
  • In this paper, a novel method to determine the optimal checkpoint interval for real-time control task is proposed considering its performance degradation according to tasks's execution time. The control task in this paper has a specific sampling period shorter than its deadline. Control performance is degraded as the control task execution time is prolonged across the sampling period and eventually zero when reached to the deadline. A new performance index is defined to represent the performance variation due to the extension of task execution time accompanying rollback fault recovery. The procedure to find the optimal checkpoint interval is addressed and several simulation examples are presented.

Exploring Control in Bottom-Up Information System Development Projects to Improve Software Development Performance

  • Cho, Donghwan
    • International Journal of Contents
    • /
    • v.15 no.2
    • /
    • pp.38-43
    • /
    • 2019
  • Recently, bottom-up information systems (BUIS), developed according to the requirements of individual user departments, have become popular. However, effective management of BUIS projects is not enough, with many organizations having experienced integration challenges with such individual projects. BUIS projects are relatively small and limited in scope, as opposed to the large, complex systems developed through traditional top-down information system development projects. Due to these differences in characteristics, the control modes as well as the aspects to improve development performance in each type of project are also different. Therefore, it is difficult to apply the results of prior research on control in system development projects to improve BUIS project performance. The purpose of this study is to derive a new theory of control to improve BUIS project performance. The results contribute to the improvement of firm performance through effective control of BUIS projects in modern enterprises.

Big Data Analysis of Software Performance Trend using SPC with Flexible Moving Window and Fuzzy Theory (가변 윈도우 기법을 적용한 통계적 공정 제어와 퍼지추론 기법을 이용한 소프트웨어 성능 변화의 빅 데이터 분석)

  • Lee, Dong-Hun;Park, Jong-Jin
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.11
    • /
    • pp.997-1004
    • /
    • 2012
  • In enterprise software projects, performance issues have become more critical during recent decades. While developing software products, many performance tests are executed in the earlier development phase against the newly added code pieces to detect possible performance regressions. In our previous research, we introduced the framework to enable automated performance anomaly detection and reduce the analysis overhead for identifying the root causes, and showed Statistical Process Control (SPC) can be successfully applied to anomaly detection. In this paper, we explain the special performance trend in which the existing anomaly detection system can hardly detect the noticeable performance change especially when a performance regression is introduced and recovered again a while later. Within the fixed number of sampling period, the fluctuation gets aggravated and the lower and upper control limit get relaxed so that sometimes the existing system hardly detect the noticeable performance change. To resolve the issue, we apply dynamically tuned sampling window size based on the performance trend, and Fuzzy theory to find an appropriate size of the moving window.

Experimental and Computational Study on Separation Control Performance of Synthetic Jets with Circular Exit

  • Kim, Minhee;Lee, Byunghyun;Lee, Junhee;Kim, Chongam
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.17 no.3
    • /
    • pp.296-314
    • /
    • 2016
  • This paper presents experimental and computational investigations of synthetic jets with a circular exit for improving flow control performance. First, the flow feature and vortex structure of a multiple serial circular exit were numerically analyzed from the view point of flow control effect under a cross flow condition. In order to improve separation control performance, experimental and numerical studies were conducted according to several key parameters, such as hole diameter, hole gap, the number of hole, jet array, and phase difference. Experiments were carried out in a quiescent condition and a forced separated flow condition using piezoelectrically driven synthetic jets. Jet characteristics were compared by measuring velocity profiles and pressure distributions. The interaction of synthetic jets with a freestream was examined by analyzing vortical structure characteristics. For separation control performance, separated flow over an airfoil at high angles of attack was employed and the flow control performance of the proposed synthetic jet was verified by measuring aerodynamic coefficient. The circular exit with a suitable hole parameter provides stable and persistent jet vortices that do beneficially affect separation control. This demonstrates the flow control performance of circular exit array could be remarkably improved by applying a set of suitable hole parameters.

Optimum control system for earthquake-excited building structures with minimal number of actuators and sensors

  • He, Jia;Xu, You-Lin;Zhang, Chao-Dong;Zhang, Xiao-Hua
    • Smart Structures and Systems
    • /
    • v.16 no.6
    • /
    • pp.981-1002
    • /
    • 2015
  • For vibration control of civil structures, especially large civil structures, one of the important issues is how to place a minimal number of actuators and sensors at their respective optimal locations to achieve the predetermined control performance. In this paper, a methodology is presented for the determination of the minimal number and optimal location of actuators and sensors for vibration control of building structures under earthquake excitation. In the proposed methodology, the number and location of the actuators are first determined in terms of the sequence of performance index increments and the predetermined control performance. A multi-scale response reconstruction method is then extended to the controlled building structure for the determination of the minimal number and optimal placement of sensors with the objective that the reconstructed structural responses can be used as feedbacks for the vibration control while the predetermined control performance can be maintained. The feasibility and accuracy of the proposed methodology are finally investigated numerically through a 20-story shear building structure under the El-Centro ground excitation and the Kobe ground excitation. The numerical results show that with the limited number of sensors and actuators at their optimal locations, the predetermined control performance of the building structure can be achieved.

Preliminary Test of Adaptive Neuro-Fuzzy Inference System Controller for Spacecraft Attitude Control

  • Kim, Sung-Woo;Park, Sang-Young;Park, Chan-Deok
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.4
    • /
    • pp.389-395
    • /
    • 2012
  • The problem of spacecraft attitude control is solved using an adaptive neuro-fuzzy inference system (ANFIS). An ANFIS produces a control signal for one of the three axes of a spacecraft's body frame, so in total three ANFISs are constructed for 3-axis attitude control. The fuzzy inference system of the ANFIS is initialized using a subtractive clustering method. The ANFIS is trained by a hybrid learning algorithm using the data obtained from attitude control simulations using state-dependent Riccati equation controller. The training data set for each axis is composed of state errors for 3 axes (roll, pitch, and yaw) and a control signal for one of the 3 axes. The stability region of the ANFIS controller is estimated numerically based on Lyapunov stability theory using a numerical method to calculate Jacobian matrix. To measure the performance of the ANFIS controller, root mean square error and correlation factor are used as performance indicators. The performance is tested on two ANFIS controllers trained in different conditions. The test results show that the performance indicators are proper in the sense that the ANFIS controller with the larger stability region provides better performance according to the performance indicators.

Update Cycle Detection Method of Control Limits using Control Chart Performance Evaluation Model (관리도 성능평가모형을 통한 관리한계선 갱신주기 탐지기법)

  • Kim, Jongwoo;Park, Cheong-Sool;Kim, Jun Seok;Kim, Sung-Shick;Baek, Jun-Geol
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.40 no.1
    • /
    • pp.43-51
    • /
    • 2014
  • Statistical process control (SPC) is an important technique for monitoring and managing the manufacturing process. In spite of its easiness and effectiveness, some problematic sides of application exist such that the SPC techniques are hardly reflect the changes of the process conditions. Especially, update of control limits at the right time plays an important role in acquiring a reasonable performance of control charts. Therefore, we propose the control chart performance evaluation index (CPEI) based on count data model to monitor and manage the performance of control charts. The CPEI could indicate the degree of control chart performance and be helpful to detect the proper update cycle of control limits in real time. Experiments using real manufacturing data show that the proper update intervals are made by proposed method.

Performance Improvement of the Horizontal Control System for a Tractor Implement Using Sensor Signal from the Front Axle

  • Ro, Young-Min;Moon, Jun-Hee;Kim, Kyeong Uk
    • Journal of Biosystems Engineering
    • /
    • v.41 no.2
    • /
    • pp.67-74
    • /
    • 2016
  • Purpose: Many tractors have adopted the horizontal control system designed to maintain the three-point mounted implements in horizontal position when they are tilted sideways. The control system rotates the implement in the opposite direction to the inclination of rear axle of the tractor. However, the current control system was found to have poor performance in accuracy and response. A new control system was therefore developed to improve the performance. Methods: The new control system was designed to get the response of the implement to be started earlier by using the tilt information from the front axle of the tractor. By this approach, the rotation of the implement can be adjusted as required to make it horizontal at the expected time, even though the response is slow. The optimal values of the control parameters for the new system were determined by computer simulation and validated by a performance test conducted with an obstacle of 120 mm height on a flat concrete surface. The performance of the control system was evaluated by the root mean square error (RMSE) of the rotation angle of the implement with respect to the actual inclination of the rear axle. Results: The new control system reduced the RMSE of the current control system by 44.6% indicating a high performance improvement. The inclination of the front axle was easily obtained from a sensor mounted on the front axle of the tractor and used as input to the new control system. Conclusions: The method of getting the response of the implement to be started earlier by utilizing the inclination information of the front axle can be applied to improve the performance of the current control system at least cost.