• Title/Summary/Keyword: contour analysis

Search Result 756, Processing Time 0.03 seconds

Performance Analysis of an Expansion Deflection Nozzle by Nozzle Length Reduction Method (노즐 길이 단축 방안에 따른 ED 노즐의 성능 분석)

  • Joomi Lee;Junsub Choi;Hwanil Huh
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.26 no.5
    • /
    • pp.11-23
    • /
    • 2022
  • For the design of the shortened ED(Expansion Deflection) nozzle, a numerical study of ED nozzle was performed according to the length reduction methods. The first method is to reduce the extension length of the ED nozzle with 80% bell nozzle length by 10%, 20% and 30%. The second method is to shorten the extension length by increasing the nozzle throat angle. Due to the increase in the curvature of the contour as the length shortened, the decrease in the nozzle exit velocity between the ED nozzle with 80% bell nozzle length and the ED nozzle in the first method was reduced, and the thrust become similar. The ED nozzle of the second method increased the thrust by increasing the nozzle exit velocity compared to the ED nozzle with 80% bell nozzle length.

Long-term outcomes after core extirpation of fibrous dysplasia of the zygomaticomaxillary region

  • Joseph Kyu-hyung Park;Se Yeon Lee;Jong-Ho Kim;Baek-kyu Kim
    • Archives of Craniofacial Surgery
    • /
    • v.24 no.2
    • /
    • pp.59-65
    • /
    • 2023
  • Background: Fibrous dysplasia (FD) is a localized bone disorder in which fibro-osseous tissue replaces the normal bone structure. Patients with craniofacial FD often present with gradual swelling, deformity, and compromised vision or hearing. We previously introduced "the core extirpation method," a novel surgical technique that is minimally invasive like traditional bone shaving but has longer-lasting effects. This study presents the long-term outcomes of our core extirpation method. Methods: We conducted a retrospective analysis of patients who underwent core extirpation for FD of the zygomaticomaxillary region from 2012 through 2021. Computed tomography (CT) scans were performed 6 to 12 months before the operation, immediately before and after the operation, and during follow-up visits. We performed all operations using the upper gingivobuccal approach, and we extirpated the core of the lesion while preserving the cortical structures of the zygoma and the maxilla to maintain symmetrical facial contour. Results: In 12 patients with lesions in the growth phase, anteroposterior/mediolateral (AP/ML) length discrepancies and the volume increased between preoperative and immediate postoperative CT scans. All patients' immediate postoperative AP/ML discrepancies were stable up to 12-17 months postoperatively. Postoperative volume showed continuous lesion growth; the median volume growth rate was 0.61 cc per month. Conclusion: In this article, we present our experiences managing FD using the minimally invasive core extirpation technique, which entails small expected blood loss and can be performed as day surgery. It provides similar cosmetic outcomes as traditional bone shaving but with longer-lasting results. Although there are some limitations with the study's retrospective nature and small sample size, our 4-year follow-up results show promising results of the core extirpation method in well-indicated patients.

Effect of the speed sintering schedule on the marginal and internal gaps of multi-layered zirconia prothesis (급속소결이 다층 지르코니아 치과보철물의 변연 및 내면 적합도에 미치는 영향)

  • Kim, Se-Yeon;Kim, Jae-Hong
    • Journal of Technologic Dentistry
    • /
    • v.44 no.1
    • /
    • pp.1-7
    • /
    • 2022
  • Purpose: The purpose of this in vitro study is to evaluate the clinical acceptability of the marginal discrepancies and internal spacing of multi-layered zirconia prothesis by speed sintering. Methods: The two specimen types come from the same manufacturer but differ in the ingredients in layered zirconia and indication, that is anterior and posterior. The designs of both specimens were full contour crowns, and a total of 20 pieces were repeatedly fabricated, 10 for each group. The specimens were divided into two subgroups (n=10) and sintered with various total times (4 hours, 8 hours) at the maximum temperature (1,530℃). The gap between the two groups of multi-layered zirconia prostheses was measured using a silicone replica technique of 2D analysis method. The independent sample t-test was then used to compare and analyze the data obtained from the two groups (α=0.05). Results: The marginal and internal gap was superior in the 8-hour compared to the 4-hour group, and the results exhibited significant differences (p<0.05). All specimens showed that using the speed sintering schedule does not exceed the clinically permitted value of 120 ㎛, meaning zirconia prothesis using the speed sintering was adequate. Conclusion: The sintering condition is shown to affect the marginal and internal gaps of multi-layered zirconia restoration.

The Influence of Appearance Satisfaction on Interest in Eye Makeup and Makeup care Behavior in Female Consumers (여성 소비자의 외모만족도가 아이 메이크업 관심도 및 메이크업 관리행동에 미치는 영향)

  • Jung, Woo-Jung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.39 no.2
    • /
    • pp.348-358
    • /
    • 2022
  • This study attempted to verify the influence of appearance satisfaction on interest in eye makeup and makeup care behavior in female consumers and provide basic data which are needed to plan marketing strategies and develop cosmetics in the cosmetics market. For this, a questionnaire survey was performed against adult women in their 20-50s from the capital region. A total of 399 copies were used for final analysis, and the results found the followings: First, differences were found in appearance satisfaction, interest in eye makeup and makeup care behavior by general characteristics. In other words, interest in eye makeup started with 'self-care', showing interest in chasing a trend. Second, concerning the effects of appearance satisfaction on interest in eye makeup, as the respondents were more satisfied with their facial contour, they were more interested in eye makeup. Third, in terms of the influence of appearance satisfaction on eye makeup care behavior, as they were more satisfied with their skin conditions, trend-setting makeup care behavior increased. Consequently, increase in appearance satisfaction enhanced interest in eye makeup, having an influence on makeup care behavior.

Analysis of Fish Activity in Relation to Feeding Events Using Infrared Cameras (적외선 카메라를 활용한 급이 유무에 따른 어류 활동성 분석)

  • Roh, Tae Kyoung;Ha, Sang Hyun;Kim, Ki Hwan;Kang, Young Jin;Jeong, Seok Chan
    • The Journal of Information Systems
    • /
    • v.32 no.4
    • /
    • pp.137-147
    • /
    • 2023
  • Purpose The domestic aquaculture industry in South Korea utilizes both formulated feeds and live feeds for the cultivation of fish. While nutrient-rich live feeds, particularly using fry, have been preferred since the past, formulated feeds are gaining attention due to issues related to overfishing and environmental concerns. Formulated feeds are advantageous for storage and supply but require a sustained feeding regimen due to the comparatively slower growth rate compared to live feeds. As the aging population in rural areas leads to a shortage of labor, automated feeding systems are increasingly being adopted in aquaculture facilities. To enhance the efficiency of such systems, it is crucial to quantitatively analyze the behavioral changes in fish based on the presence or absence of feed. Design/methodology/approach In the study, RGB cameras and infrared cameras were used to analyze fish activity according to feeding, and an outline extraction algorithm was applied to analyze the differences resulting from this. Findings Unlike RGB cameras, infrared cameras are more suitable for analyzing underwater fish activity as they convert objects' thermal energy into images. It was observed that Canny, Sobel, and Prewitt filters showed the most distinct identification of fish activity.

Comparison of local flaps versus skin grafts as reconstruction methods for defects in the medial canthal region

  • Min Hak Lee;Hoon Soo Kim;Yong Chan Bae
    • Archives of Craniofacial Surgery
    • /
    • v.25 no.3
    • /
    • pp.133-140
    • /
    • 2024
  • Background: The medial canthal region features a complex three-dimensional and internal anatomical structure. When reconstructing a defect in this area, it is crucial to consider both functional and aesthetic aspects, which presents significant challenges. Generally, local flaps are preferred for reconstruction; however, skin grafts can be used when local flaps are not feasible. Therefore, we conducted a comparative analysis of surgical outcomes skin grafts when local flaps were not feasible, to determine which surgical method is more effective for medial canthal region reconstruction. Methods: Twenty-five patients who underwent medial canthal region reconstruction using skin grafts or local flaps from 2002 to 2021 were enrolled. Patient information was obtained from medical records. Five plastic surgeons evaluated the surgical outcomes based on general appearance, color, contour, and symmetry. Results: Skin grafts were used in eight patients and local flaps were used in 13. Combined reconstructions were employed in four cases. Minor complications arose in four cases but improved with conservative treatment. No major complications were reported. Recurrence of the skin cancer was noted in two cases. All categories showed higher scores for the local flap compared to both skin graft and combined reconstruction; however, the differences were not statistically significant respectively. Conclusion: The choice of appropriate surgical methods for reconstructing defects in the medial canthal region depends on various factors, including the patient's overall health, the size and depth of the defect, and the degree of involvement of surrounding structures. When a local flap is not feasible, a skin graft may provide favorable surgical outcomes. Therefore, a skin graft can serve as a viable alternative for reconstructing the medial canthal region.

A Theoretical Model for the Analysis of Residual Motion Artifacts in 4D CT Scans (이론적 모델을 이용한 4DCT에서의 Motion Artifact 분석)

  • Kim, Tae-Ho;Yoon, Jai-Woong;Kang, Seong-Hee;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.145-153
    • /
    • 2012
  • In this study, we quantify the residual motion artifact in 4D-CT scan using the dynamic lung phantom which could simulate respiratory target motion and suggest a simple one-dimension theoretical model to explain and characterize the source of motion artifacts in 4DCT scanning. We set-up regular 1D sine motion and adjusted three level of amplitude (10, 20, 30 mm) with fixed period (4s). The 4DCT scans are acquired in helical mode and phase information provided by the belt type respiratory monitoring system. The images were sorted into ten phase bins ranging from 0% to 90%. The reconstructed images were subsequently imported into the Treatment Planning System (CorePLAN, SC&J) for target delineation using a fixed contour window and dimensions of the three targets are measured along the direction of motion. Target dimension of each phase image have same changing trend. The error is minimum at 50% phase in all case (10, 20, 30 mm) and we found that ${\Delta}S$ (target dimension change) of 10, 20 and 30 mm amplitude were 0 (0%), 0.1 (5%), 0.1 (5%) cm respectively compare to the static image of target diameter (2 cm). while the error is maximum at 30% and 80% phase ${\Delta}S$ of 10, 20 and 30 mm amplitude were 0.2 (10%), 0.7 (35%), 0.9 (45%) cm respectively. Based on these result, we try to analysis the residual motion artifact in 4D-CT scan using a simple one-dimension theoretical model and also we developed a simulation program. Our results explain the effect of residual motion on each phase target displacement and also shown that residual motion artifact was affected that the target velocity at each phase. In this study, we focus on provides a more intuitive understanding about the residual motion artifact and try to explain the relationship motion parameters of the scanner, treatment couch and tumor. In conclusion, our results could help to decide the appropriate reconstruction phase and CT parameters which reduce the residual motion artifact in 4DCT.

Three-dimensional morphometric analysis of mandibule in coronal plane after bimaxillary rotational surgery

  • Lee, Sung-Tak;Choi, Na-Rae;Song, Jae-Min;Shin, Sang-Hun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.49.1-49.9
    • /
    • 2016
  • Background: The aim of this report is to present a new reference for aesthetic mandible surgery using three-dimensional cone-beam computed tomography-based treatment planning for orthognathic surgery which can be implemented in surgical planning and perioperative procedure. Methods: To make an objective standard for evaluating aesthetic mandibular outline, we make an aesthetic scoring criteria with consideration of asymmetry, broad mandibular border line, and prominent mandibular angle. Two maxillofacial surgeons and two orthodontists rated their aesthetical evaluation from 1 to 5. Experimental group consisting of 47 female and 38 male patients who had rotational orthognathic two-jaw surgery from 2010 to 2011 were chosen according to aesthetic scoring done by two maxillofacial surgeons and two orthodontists. A high aesthetic score (${\geq}16$) means the facial contour is symmetric, with no broad and narrow aesthetic mandible frontal profiles. Control A group consisted of ten female and ten male patients who had no orthognathic surgery experience and low aesthetic score (${\geq}10$). Control B group consisted of ten female and ten male patients who had no orthognathic surgery experience and had anaesthetic mandibular frontal profile and a high aesthetic score (${\geq}16$). The three-dimensional image of the patient was taken from dental cone-beam CT (DCT) scanning (experimental group and control A group: 6 months DCT after surgery, control B group: 1st visit DCT). Each DCT was reformatted to reorient the 3D image using 3D analyzing program (OnDemand3D, cybermed Inc, CA, USA). After selection of 12 landmarks and the construction of reoriented horizontal, vertical, and coronal reference lines, 15 measurements were taken in 3D analysis of frontal mandibular morphology. Afterwards, horizontal and vertical linear measurements and angular measurements, linear ratio were obtained. Results: Mean $Go^{\prime}_{Rt}-Me^{\prime}-Go^{\prime}_{Lt}$ angular measurement was $100.74{\pm}2.14$ in female patients and $105.37{\pm}3.62$ in male patients. These showed significant difference with control A group in both genders. Ratio of $Go^{\prime}_{Rt}-Go^{\prime}_{Lt}-Me^{\prime}$ length to some linear measurements (ratio of $Me^{\prime}-Cd^{\prime}_{Rt}Cd^{\prime}_{Lt}$ to $Me^{\prime}-Go^{\prime}_{Rt}Go^{\prime}_{Lt}$, ratio of $Me^{\prime}-Go^{\prime}$ to $Me^{\prime}-Go^{\prime}_{Rt}Go^{\prime}_{Lt}$, ratio of $Go^{\prime}_{Rt}-Go^{\prime}_{Lt}$ to $Me^{\prime}-Go^{\prime}_{Rt}Go^{\prime}_{Lt}$) showed significant difference with control A group in both genders. Conclusion: This study was intended to find some standard measurement of mandible frontal view in 3D analysis of aesthetic patient. So, these potential measurement value may be helpful for orthognathic treatment planning to have more aesthetic and perspective outcomes.

Development of RMRD and Moving Phantom for Radiotherapy in Moving Tumors

  • Lee, S.;Seong, Jin-Sil;Chu, Sung-Sil;Yoon, Won-Sup;Yang, Dae-Sik;Choi, Myung-Sun;Kim, Chul-Yong
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.63-63
    • /
    • 2003
  • Purpose: Planning target volume (PTV) for tumors in abdomen or thorax includes enough margin for breathing-related movement of tumor volumes during treatment. We developed a simple and handy method, which can reduce PTV margins in patients with moving tumors, respiratory motion reduction device system (RMRDs). Materials and Methods: The patients clinical database was structured for moving tumor patients and patient setup error measurement and immobilization device effects were investigated. The system is composed of the respiratory motion reduction device utilized in prone position and abdominal presser (strip device) utilized in the supine position, moving phantom and the analysis program, which enables the analysis on patients setup reproducibility. It was tested for analyzing the diaphragm movement and CT volume differences from patients with RMRDs, the magnitude of PTV margin was determined and dose volume histogram (DVH) was computed using a treatment planning software. Dose to normal tissue between patients with RMRDs and without RMRDs was analyzed by comparing the fraction of the normal liver receiving to 50% of the isocenter dose(TD50). Results: In case of utilizing RMRDs, which was personally developed in our hospital, the value was reduced to $5pm1.4 mm$, and in case of which the belt immobilization device was utilized, the value was reduced to 3$pm$0.9 mm. Also in case of which the strip device was utilized, the value was proven to reduce to $4pm.3 mm$0. As a result of analyzing the TD50 is irradiated in DVH according to the radiation treatment planning, the usage of the respiratory motion reduction device can create the reduce of 30% to the maximum. Also by obtaining the digital image, the function of comparison between the standard image, automated external contour subtraction, and etc were utilized to develop patients setup reproducibility analysis program that can evaluate the change in the patients setup. Conclusion: Internal organ motion due to breathing can be reduced using RMRDs, which is simple and easy to use in clinical setting. It can reduce the organ motion-related PTV margin, thereby decrease volume of the irradiated normal tissue.

  • PDF

3D-QSARs analyses for Tyrosinase Inhibitory Activity of 2-Phenyl-1,4-benzopyrone (Flavones) Analogues and Molecular Docking (2-Phenyl-1,4-benzopyrone 유도체 (Flavones)의 Tyrosinase 저해활성에 관한 3D-QSARs 분석과 분자도킹)

  • Park, Joon-Ho;Sung, Nack-Do
    • Journal of Applied Biological Chemistry
    • /
    • v.53 no.4
    • /
    • pp.225-231
    • /
    • 2010
  • To understand the inhibitory activity with changing hydroxyl substituents ($R_l-R_9$) of polyhydroxy substituted 2-phenyl-l,4-benzopyrone analogues (1-25) against tyrosinase (PDB ID: oxy-form; 1WX2), molecular docking and the three dimensional quantitative structure-activity relationships (3D-QSARs: Comparative molecular field analysis (CoMFA) & Comparative molecular similarity indices analysis (CoMSIA)) were studied quantitatively. The statistically best models were CoMFA 1 and CoMSIA 1 model from the results. The optimized CoMSIA 1 model with the sensitivity of the perturbation and the prediction produced ($dq^2'/dr_{yy'}^2$=1.009 & $q^2$=0.51l) by a progressive scrambling analysis were not dependent on chance correlation. The inhibitory activities with optimized CoMSIA 1 model were dependent upon electrostatic factor (51.4%) of substrate molecules. Contour mapping the 3D-QSAR models to the active site of tyrosinase provides new insight into the interaction between tyrosinase as receptor and 2-phenyl-l,4-benzopyrone analogues as inhibitor. Therefore, the results will he able to apply to the optimization of a new potent tyrosinase inhibitors.