• 제목/요약/키워드: continuous vibration

검색결과 443건 처리시간 0.03초

광주·전남지역 치과위생사의 수근관증후근에 대한 연구 (The study on the Carpal Tunnel Syndrome by dental hygienists at Gwangju·Jeonnam Area)

  • 심형순
    • 한국치위생학회지
    • /
    • 제4권2호
    • /
    • pp.225-236
    • /
    • 2004
  • It has been suggested in research results thai dental hygienists have high risk of carpal tunnel syndrome, mainly caused by the repeated motion of extensor and flexor or the use of vibration tools, compared to other occupations. To find out the situation of the carpal tunnel syndrome of dental hygienists, who are exposed to work-related musculoskeletal disorders, this study used 132 questionnaires given on May 22, 2004, the period of continuing education of the first half year in the Gwangju Jeonnam area, and obtained the following results. 1. Subjects worked at a dental ciinic(32.6%), a hospital(31.8%), and a public health center(35.6%). Age by work was under 24 in a clinic(17.4%) and a hospital(15.9%), and over 30 in a public health center(35.6%). 2. In practice conducted over one time a day, a scaling accounted for 90.7% in a doctor's office; 595% in a hospital; and 3.0% in a public health center, suggesting significant difference(p<0.01). Pit and fissure sealant accounted for 53.5% in a clinic; 53.2% in a hospital; and 95% in a public health center, also suggesting significant difference(p0.01). 3. Symptoms of carpal tunnel syndrome appeared in a wrist(12.1%), a right hand(14.4%), and a left hand(5.3%). 4. In case of temporary crown practice, symptoms appeared in a wrist(22.0%), a right hand(14.0%), and a left hand(4.0%), suggesting significant difference(p<0.01). The above results showed that 12.1% of dental hygienists was exposed to carpal tunnel syndrome. Thus, it is considered very important that dental hygienists should be given education of the danger of continuous work in certain motions and prevention education of improving repeated position, and make efforts to reinforce self-control ability.

  • PDF

Multiplexed Hard-Polymer-Clad Fiber Temperature Sensor Using An Optical Time-Domain Reflectometer

  • Lee, Jung-Ryul;Kim, Hyeng-Cheol
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제17권1호
    • /
    • pp.37-44
    • /
    • 2016
  • Optical fiber temperature sensing systems have incomparable advantages over traditional electrical-cable-based monitoring systems. However, the fiber optic interrogators and sensors have often been rejected as a temperature monitoring technology in real-world industrial applications because of high cost and over-specification. This study proposes a multiplexed fiber optic temperature monitoring sensor system using an economical Optical Time-Domain Reflectometer (OTDR) and Hard-Polymer-Clad Fiber (HPCF). HPCF is a special optical fiber in which a hard polymer cladding made of fluoroacrylate acts as a protective coating for an inner silica core. An OTDR is an optical loss measurement system that provides optical loss and event distance measurement in real time. A temperature sensor array with the five sensor nodes at 10-m interval was economically and quickly made by locally stripping HPCF clad through photo-thermal and photo-chemical processes using a continuous/pulse hybrid-mode laser. The exposed cores created backscattering signals in the OTDR attenuation trace. It was demonstrated that the backscattering peaks were independently sensitive to temperature variation. Since the 1.5-mm-long exposed core showed a 5-m-wide backscattering peak, the OTDR with a spatial resolution of 40 mm allows for making a sensor node at every 5 m for independent multiplexing. The performance of the sensor node included an operating range of up to $120^{\circ}C$, a resolution of $0.59^{\circ}C$, and a temperature sensitivity of $-0.00967dB/^{\circ}C$. Temperature monitoring errors in the environment tests stood at $0.76^{\circ}C$ and $0.36^{\circ}C$ under the temperature variation of the unstrapped fiber region and the vibration of the sensor node. The small sensitivities to the environment and the economic feasibility of the highly multiplexed HPCF temperature monitoring sensor system will be important advantages for use as system-integrated temperature sensors.

지점 위에 질량과 강성이 큰 연결기를 갖는 다경간 보의 모드편재 (Mode Localization in Multispan Beams with Massive and Stiff Couplers on Supports)

  • Dong-Ok Kim;Sun-Kyu Park;In-Won Lee
    • 소음진동
    • /
    • 제8권6호
    • /
    • pp.1166-1171
    • /
    • 1998
  • 본 연구에서는 이웃한 두 경간 사이에 있는 질량과 강성을 갖는 연결기가 모드편재에 미치는 영향을 해석적으로 분석하고 수치예제를 통해 그 결과를 검증하였다. 연결기의 강성이 구조물의 모든 고유모드를 모드편재에 민감하게 만드는 반면 연결기의 질량은 고차모드의 민감도를 심각히 증가시킨다. 또한 본 연구에서는 일부 고유모드에서 새로운 형태의 반편재현상을 관찰하였다. 반편재현상이 발생하는 모드에서는 경간 사이의 연성이 매우 약하고 구조 변화가 심각하게 발생하더라도 모드편재 현상이 발생하지 않거나 발생하더라도 매우 미약하게 나타난다. 해석적 분석에서는 연결기를 사이에 두고 있는 두개의 부구조물을 단순화 시킨 강성-질량 시스템을 대상으로 하였다. 수치예제에서는 중간 지점에 회전강성과 회전질량을 갖으며 단순지지된 이경간 연속보를 해석하였다.

  • PDF

국내 지하철 정비 사업장의 근골격계질환 실태조사에 관한 연구 (A Study of Musculoskeletal Disorders at a Subway Train Repair Plant in Korea)

  • 김철홍;권영준;백승렬;손경일
    • 대한인간공학회지
    • /
    • 제23권3호
    • /
    • pp.121-134
    • /
    • 2004
  • A research project was conducted to study work-related musculoskeletal disorders (MSDs) at subway train repair plant in Korea. The project was consisted of 4 main parts; education on the topics of MSDs for all workers, symptom survey, medical check-up, investigation of MSD risk factors. The result of symptom survey showed that 95.2% of the respondents complained pains on at least one part of the body. After cross-sectional analysis of various information and risk factors, 86.8% of respondents were considered as active health surveillance level 1 that require continuous monitoring on their symptoms and working conditions. And 57.1% of the respondents were considered as active health surveillance level 2 that needed medical check-ups for proper medical treatment. The analysis of occupational risk factors revealed that handling of heavy object (46.15%) and repeated awkward postures (46.15%) were two most contributing risk factors for the on-set of MSD at this work site followed by static strain (7.7%), and vibration and impact (3.8%). Medical examination was performed by an industrial medicine MD on 156 workers those considered as active health surveillance level 2. The result showed that 35 workers (20.7%) were considered as MSD patient group at severe level, and 68.6 workers (68.6%) were considered as moderate group and 18 workers (10.6%) were considered minor or normal group those have no symptom.

코콜이 환자의 sleep splint 착용 전후의 음향학적 및 공기역학적 연구 (An Aerodynamic study used aerophone II for snoring patients)

  • 정세진;김현기;신효근
    • 대한치과의사협회지
    • /
    • 제49권4호
    • /
    • pp.219-226
    • /
    • 2011
  • Snoring and obstructive sleep apnea (OSA) are common sleep disordered breathing conditions. Habitual snoring is caused by a vibration of soft tissue of upper airway while breath in sleeping, and obstructive sleep apnea is caused by the repeated obstructions of airflow for a sleeping, specially airflow of pharynx. Researchers have shown that snoring is the most important symptom connected with the obstructive sleep apnea syndrome The treatment is directed toward improving the air flow by various surgical and nonsurgical methods. The current surgical procedures used are uvulopalatopharyngoplasty(UPPP), orthognathic surgery, nasal cavity surgery. Among the nonsurgical methods there are nasal continuous positive air pressure(CPAP), pharmacologic therapy. weight loss in obese patient, oral appliance(sleep splint). Sleep splint brings the mandible forward in order to increase upper airway volume and prevents total upper airway collapse during sleep. However, the precise mechanism of action is not yet completely understood, especially aerodynamic factor. The aim of this study evaluated the effect of conservative treatment of snoring and OSAS by sleep splint through measured aerodynamic change by an aerophone II. We measured a airflow, sound pressure level, duration, mean power from overall airflow by aerophone II mask. The results indicated that on a positive correlation between a decrease in maximum airflow rate and a decrease in maximum sound pressure level, on a negative correlation between a decrease in maximum airflow rate and a increase in duration.

저압용 누전차단기 접속부의 발열 및 금속 조직 분석에 관한 연구 (A Study on the Analysis of Heat and Metallurgical Structure of Connection Parts for Residual Current Protective Devices)

  • 최충석;송길목;김동욱;김동우;김영석
    • 한국화재소방학회논문지
    • /
    • 제18권4호
    • /
    • pp.57-63
    • /
    • 2004
  • 본 연구에서는 저압용 누전차단기 접속단자에서의 접촉압력에 따른 발열특성을 조사하고 차단기 단자와 전선에 접촉 불량이 발생했을 때의 전압, 전류파형과 산화물 증식 등을 분석하였다. 차단기 단자와 전선에 접촉압력이 가해지지 않았을 때는 접촉저항증가로 열이 발생하고 금속표면에 산화 막이 형성되었다. 이때 단자 외부 절연물의 온도는 접촉 불량에 의해 급격하게 상승하며 단자내부에서 미세한 불꽃과 연속적인 방전음이 발생하였다. 단자내부도체와 접속전선 접촉면에서 기계적 진동에 의한 접촉 불량이 발생했을 때, 접촉면에서 산화물이 증식되고 발열온도는 869℃이상으로 상승하여 전기재해의 위험이 높음을 알 수 있었다.

재해대비 농업용저수지 취수시설로서 사이폰의 현장적용성에 관한 실험적 연구 (Experiment Study on Field Applicability of Siphon as a Intake Facility of Agricultural Reservoir for Disaster Prevention)

  • 양영진;이태호;오수훈
    • 한국농공학회논문집
    • /
    • 제60권2호
    • /
    • pp.103-110
    • /
    • 2018
  • Most of the intake facilities of small agricultural reservoirs are conduits and they are regarded as serious defects due to the structural weakness that penetrates the body of the dam, and countermeasures are needed. This study suggests the application method of siphon type water intake facility by hydraulic model test and physical scale model test of siphon type water intake facility which has high safety and easy maintenance. Experimental results show that sufficient flow rate can be secured for the purpose of intaking water according to the differential head between the reservoir and the discharge part, and the flow rate can be controlled by the valve. The negative pressure was -31.5 kPa, and vibration and noise did not occur during the operation of the siphon. The maximum flow velocity in the discharge outlet was 1.11 m/s which meets the criterion for irrigation canals. Therefore, scour risk would be very low. As a result of the inflow distribution experiment, even if the inflow part is separated by only about 0.8 m, the flow velocity is remarkably decreased, so that the clogging by debris would not appear. When the pump was operated only once for the first time and the inside of the siphon was filled with water, continuous operation was possible by only valve operation. The results of this study are expected to be used for the design guidelines of the water intake facilities and improve safety and maintenance convenience of agricultural reservoirs.

A Ripple Rejection Inherited RPWM for VSI Working with Fluctuating DC Link Voltage

  • Jarin, T.;Subburaj, P.;Bright, Shibu J V
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권5호
    • /
    • pp.2018-2030
    • /
    • 2015
  • A two stage ac drive configuration consisting of a single-phase line commutated rectifier and a three-phase voltage source inverter (VSI) is very common in low and medium power applications. The deterministic pulse width modulation (PWM) methods like sinusoidal PWM (SPWM) could not be considered as an ideal choice for modern drives since they result mechanical vibration and acoustic noise, and limit the application scope. This is due to the incapability of the deterministic PWM strategies in sprawling the harmonic power. The random PWM (RPWM) approaches could solve this issue by creating continuous harmonic profile instead of discrete clusters of dominant harmonics. Insufficient filtering at dc link results in the amplitude distortion of the input dc voltage to the VSI and has the most significant impact on the spectral errors (difference between theoretical and practical spectra). It is obvious that the sprawling effect of RPWM undoubtedly influenced by input fluctuation and the discrete harmonic clusters may reappear. The influence of dc link fluctuation on harmonics and their spreading effect in the VSI remains invalidated. A case study is done with four different filter capacitor values in this paper and results are compared with the constant dc input operation. This paper also proposes an ingenious RPWM, a ripple dosed sinusoidal reference-random carrier PWM (RDSRRCPWM), which has the innate capacity of suppressing the effect of input fluctuation in the output than the other modern PWM methods. MATLAB based simulation study reveals the fundamental component, total harmonic distortion (THD) and harmonic spread factor (HSF) for various modulation indices. The non-ideal dc link is managed well with the developed RDSRRCPWM applied to the VSI and tested in a proto type VSI using the field programmable gate array (FPGA).

시간영역 변형형상을 이용한 철도교량의 손상평가 (Damage Evaluation of a Railroad Bridge Using Time-domain Deflection Shape)

  • 최상현;임남형;강영종
    • 한국철도학회논문집
    • /
    • 제12권1호
    • /
    • pp.129-134
    • /
    • 2009
  • 공용기간동안 철도교량의 안전성 및 사용성을 확보하기 위해서는 지속적인 감시를 통하여 교량의 구조적 성능을 유지하는 것이 필요하다. 구조물의 구조적 건전성을 감시하기 위하여 현재까지 개발된 대부분의 방법들은 모달 응답을 이용하고 있으나, 이러한 모달응답은 별도의 추출 과정이 필요하며 실제 구조물에서 얻을 수 있는 수가 제한된 다는 단점이 있다. 이 논문에서는 열차이동하중으로 인한 시간영역의 변형형상을 이용하여 자유진동응답에 기반한 손상평가방법의 적용성을 검토하였다. 검토된 방법은 이동하중으로 인한 시간영역의 변형응답을 이용하므로 별도의 모달 응답 추출과정이 필요 없어 실제 구조물에 적용이 용이하다. 제시된 방법의 적용성은 단순판형교 수치예제를 이용하여 검증하였다.

수직 진동을 이용한 가열된 고체표면 위 증발하는 액적의 내부유동 제어연구 (Study of the Internal Flow and Evaporation Characteristic Inside a Water Droplet on a Vertical Vibrating Hydrophobic Surface)

  • 박창석;임희창
    • 대한기계학회논문집B
    • /
    • 제41권1호
    • /
    • pp.37-46
    • /
    • 2017
  • 가열된 표면에서의 액적은 일반적으로 내부에 마랑고니 유동이 발생하고, 이는 불균일한 침전물 패턴 형상을 구성하게 된다. 본 연구는 마랑고니 유동을 가시화하고, 수직진동을 사용해서 이를 제어하는 것을 주 목적으로 한다. 액적이 증발하는 동안, 액적의 접촉각 변화와 부피변화를 실험적으로 알 수 있었고, PIV(Particle Image Velocimetry) 실험 장치를 이용하여, 평판 온도별 마랑고니 유동의 내부 유동의 흐름을 가시화하였다. 그리고 평판에 각 주파수별 수직진동을 가해주는 실험을 진행하여, 그 결과 마랑고니 유동의 유동 방향과 수직진동의 유동 방향이 서로 반대인 것을 확인할 수 있었다. 마지막으로 증발하는 액적에 수직진동을 가해줌으로써, 액적의 하단부분에서 내부유동의 흐름변화를 관찰하였다. 마랑고니유동에 의해 발생하는 내부유동 방향과 수직진동으로 발생하는 내부유동의 방향이 서로 반대 방향이므로 가열된 평판에 진동을 가해주었을 때 액적 내부유동의 흐름이 변화가 발생하였고, 이는 곧 불균일한 침전물 패턴이 억제된 것을 증발 후 침전물의 패턴형상을 통해 확인할 수 있었다.