• Title/Summary/Keyword: continuous flow-through system

Search Result 138, Processing Time 0.027 seconds

Effect of Dynamic Flow on the Structure of Inhibition Layer in Hot-dip Galvanizing

  • Jin, Young Sool;Kim, Myung Soo;Kim, Su Young;Paik, Doo Jin
    • Corrosion Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.30-36
    • /
    • 2011
  • The effect of dynamic flow or forced convection were investigated and compared on the formation of inhibition layer, galvanizing and galvannealing reactions through the hot-dip galvanizing simulator with the oscillation of specimen in zinc bath, continuous galvanizing pilot plant with zinc pumping system through the snout and continuous galvanizing operation with Dynamic $Galvanizing^{TR}$ system. The interfacial Al pick-up was not consistent between the results of simulator, pilot plant and line operation, but the morphology of inhibition layer became compact and refined by the forced convection. The growth of Fe-Zn intermetallics at the interface was inhibited by the forced convection, whereas the galvannealing rate would be a little promoted.

A continuous-flow and on-site mesocosm for ocean acidification experiments on benthic organisms

  • Kim, Ju-Hyoung;Kang, Eun Ju;Kim, Keunyong;Kim, Kwang Young
    • ALGAE
    • /
    • v.33 no.4
    • /
    • pp.359-366
    • /
    • 2018
  • Mesocosm experiments conducted for ecological purposes have become increasingly popular because they can provide a holistic understanding of the biological complexities associated with natural systems. This paper describes a new outdoor mesocosm designed for $CO_2$ perturbation experiments of benthos. Manipulated the carbonate chemistry in a continuous flow-through system can be parallelized with diurnal changes, while irradiance, temperature, and nutrients can vary according to the local environment. A target hydrogen ion activity (pH) of seawater was sufficiently stabilized and maintained within 4 h after dilution, which was initiated by the ratio of $CO_2$-saturated seawater to ambient seawater. Specifically, pH and $CO_2$ partial pressure ($pCO_2$) levels gradually varied from 8.05-7.28 and $375-2,691{\mu}atm$, respectively, over a range of dilution ratios. This mesocosm can successfully manipulate the pH and $pCO_2$ of seawater, and it demonstrates suitability for ocean acidification experiments on benthic communities.

Studies on Solvent Sublation of Trace Heavy Metals by Continuous Flow System as Ternary Complexes of 1,10-Phenanthroline and Thiocyanate Ion

  • Kim, Young-Sang;Choi, Yoon-Seok;Lee, Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.12
    • /
    • pp.1775-1780
    • /
    • 2003
  • A continuous flow system has been developed to determine trace Cu(II), Mn(II), Ni(II) and Zn(II) in a large volume of water samples by a solvent sublation technique. The mixed solution of 1,10-phenanthroline(phen) and thiocyanate ion was used as ligands for the formation of their ternary complexes. The continuous system was constructed in this laboratory with a peristaltic pump, a mini shaker, three mixing bottles and a flotation cell by connecting each part with a polyethylene tube. The flotation conditions such as the flow rate of sample solution and the injection rates of ligand, buffer and surfactant solutions have been investigated to obtain the best sublation efficiencies. Each solution flowed into the flotation cell through each polyethylene tube by the peristaltic pumps. The ternary complexes were floated and extracted into MIBK in a flotation cell of 2 L by bubbling a nitrogen gas. The absorbances of extracted analytes in MIBK were directly measured by graphite furnace-AAS. The concentrations of 1,10-phenanthroline and thiocyanate ion were $2.6\;{\times}\;10^{-3}$ M and $2.3\;{\times}\;10^{-2}$ M in the mixed solution, respectively. The pH of sample solution was adjusted to 5.0 with a buffer solution and 1%(m/v) sodium lauryl sulphate solution was added as a surfactant to support the effective flotation of the complexes. The $N_2$ gas was bubbled at 30 mL/min for 90 minutes for 20 L of sample. Reproducible results of less than 10% RSD and recoveries of 80-120% could be obtained in real samples.

Thermal Analysis on Triple-Passage Heat Exchangers for a Continuous Hot-Steel Tube Cooling System

  • Ko, Bong-Hwan;Park, Seung-Ho
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.1
    • /
    • pp.10-18
    • /
    • 2002
  • The objective of present study is to analyze a concentric triple-passage heat exchanger for an optimal design of a continuous hot steel-tube cooling system, where a hot-steel tube line is passing through an antioxidant gas with a constant speed. Velocities and temperatures of the inert gas flowing between inner and outer tubes are calculated theoretically for laminar and numerically for turbulent flow regimes. From their profiles Nusselt numbers and friction factors are calculated (or various ratios of inner/outer tube radii and relative velocities. With these Nusselt numbers triple-passage heat exchangers are investigated for their thermal characteristics. It is shown that heat transfer coefficients based on ratios of average heat fluxes from inner and outer tubes might result in great errors for the temperature distributions of the flows, since local heat transfer coefficients for flows through an annulus are dependent on local wall heat flux ratios.

Immobilized Luminescent Cell - based Flow Through Monitoring of Environmental Pollutants

  • Britz, Margaret L.;Simonov, Nina;Chun, Uck-Han
    • Journal of Microbiology and Biotechnology
    • /
    • v.7 no.4
    • /
    • pp.250-257
    • /
    • 1997
  • A new sensing system based on the immobilization of luminescent bacteria, photobacterium phosphoreum, was proposed for continuous real-time monitoring of pollutants. The response curves demonstrate that Photobacterium phosphoreum immobilized on the strontium alginate were very sensitive to seven reference chemicals used. The significant inhibitory concentrations for bioluminescence emission were 5 ppm for Pb$(NO_3)_2$), $NiCl_2$, $CdCl_2$, 50 ppm for $NaASO_2$, 0.1 ppm for $HgCl_2$, 0.5 ppm for pentachlorophenol and less than 5 ppm for SDS, respectively. The alginate mixed-cells (AMC) retained their luminescence during experimental period (29 days) under storage condition of $-80^{\circ}C$. The variables affecting performance of continuous flow through monitoring (CFTM) was optimized in order to ensure stability and efficiency. The flow through cell with strontium-alginate immobilized luminescent bacteria was tested with salicylate and 4-nitrophenol. A rapid response of luminescence was recorded by time drive mode in bioluminescence spectrometer after exposure to both toxicants.

  • PDF

Gas-Sensing Membrane Electrodes for the Determination of Dissolved Gases (Ⅳ). Continuous-Automated Determination of Sulfide Ion Using Tubular PVC Membrane Type pH Electrode (용해기체 분석용 기체감응막 이온선택성 전극 (제 4 보) 관형 PVC막 pH전극을 이용한 황화이온의 연속 · 자동화 정량)

  • Lee Heung Lark;Bae Zun Ung;Oh Sang-Hyub
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.5
    • /
    • pp.638-643
    • /
    • 1992
  • The analytical response properties of two types of continuous flow-through electrode system as fulfide ion detectors are examined and directly compared their reponse characteristics under the optimal conditions. In both detection systems, observed peak potentials are logarithmically related to the sulfide ion concentration and at least twenty samples per hour can be determined. In the pH electrode method, the pH of the flowing recipient stream leaving the dialyzer was monitored. The designed system involves the use of continuous flow gas dialyzer in conjunction with the tubular polymer membrane electrode. In this method, optimal experimental conditions are recipient of mixture of $5.0 {\times} 10^{-5} M NaOH + 5.0 {\times} 10^{-3} M$ NaCl and diluent of 0.10 M $H_2SO_4$, and all flow rates of recipient stream, diluent stream, and sample are 1.0 ml/min. In the sulfide ion electrode method, a commercially available sulfide ion-selective electrode was used to detect sulfide ion in the flow-through cell. The optimal flow rates of sulfide anti-oxidant buffer (3.5 g ascorbic acid and 7.6 g $Na_2EDTA$ dissolved in 1.0 M NaOH solution 1 l) and sample were 1.4 ml/min and 1.0 ml/min, respectively.

  • PDF

Biological Treatment of Processed-Leachate from Landfills by Reed (Phragmites australis)-Bed in a Continuous Flow System (갈대-상(床)을 이용한 쓰레기 매립지 침출수의 생물학적 연속흐름 처리)

  • Kim, In-Sung;Cho, Yong-Joo;Choi, Hong-Keun;Lee, Eun-Ju
    • The Korean Journal of Ecology
    • /
    • v.27 no.6 s.122
    • /
    • pp.375-381
    • /
    • 2004
  • We investigate the biological treatment of processed-leachate from SUDOKWON landfill site in Korea by the reed (Phragmites australis)-bed with a continuous flow system. The reed individuals showing superior growth in processed-leachate experiment were selected among the reeds of thirteen natural habitats by means of the comparisons between the removal rates of nutrient salts, eco-physiological responses and growth. The reed-beds (combination of the reed individuals showing superior growth with helper microorganisms) were continuously supplied with processed-leachate. We monitored the effluents that passing through the reed-beds during the experiment period. After five weeks, analysis results of effluent from each reed-bed were as follows; chromaticity, total nitrogen, total phosphorus, biological oxygen demand, chemical oxygen demand, total dissolved solid and salinity decreased $29.5{\sim}36.9\%,\;49.4{\sim}67.2\%,\;42.1{\sim}94.6\%,\;74.5{\sim}88.8\%,\;15.6{\sim}20.8\%,\;17.5{\sim}35.4\%\;and\;15.3{\sim}34.7\%$, respectively. These results represented the substantial improvement of water-quality after passing through reed-bed in a continuous flow system.

Case Study on Job Flow Improvement of Foodservice at a University Hospital (대학병원 급식업무 개선 사례 연구)

  • Kim, Hyung Mi;Yang, Il Sun;Park, Eun Cheol;Lim, Hyun Sook
    • Quality Improvement in Health Care
    • /
    • v.7 no.2
    • /
    • pp.244-261
    • /
    • 2000
  • Background : In order to cope with changes in the management environment at hospitals, increased interests are drawn in patient foodservice system on Continuous Quality Improvement Activity as the method of approaching a quality food service and effective management. Thus, as a part of this activity, this study was conducted to evaluate job flow improvement that was already performed and the results of that process at the dietetic department of a university hospital, focusing on improving management. Method : On February 15 of 1998. the dietetic department formed a job flow-improvement to decide on the priority of job flow improvement, and prepared specific action strategies and schedule of the priority: after a 5 month process period, job improvement achieved on June 15. 1998. Also, economic achievement of the task was evaluated through labor productivity analysis and cost-benefit analysis. Results : The patient food service system which was managed decentralized at the present hospital was centralized, some steps of the food service process were integrated, and quality of patient food was improved. Also, as a solution of the problems expected when conducting job flow improvement was made on food service equipments and utensils. The result of evaluating the job flow improvement that labor productivity improved by 18.2% compared to before the improvement and the result of the analysis of cost-benefit showed that Benefit-Cost (B/C) ratio was 2.22. showing financial merit on the investment. Conclusions : Continuous Quality Improvement Activity needs to be initiated and conducted in the future in various areas of hospital foodservice system in order to actively adopt to ever changing hospital management environment. In order to achieve this goal, many researches and more efforts need to be put in by people in charge of hospital food service management, and interests and support are needed from hospital policy makers.

  • PDF

Simulation of Energy Conversion Characteristics of OMACON LM-MHD Systems (OMACON형 LM-MHD 시스템에서의 에너지전환특성 시뮬레이션)

  • 김창녕
    • Journal of the Korea Society for Simulation
    • /
    • v.6 no.2
    • /
    • pp.1-14
    • /
    • 1997
  • The characteristics of the flow and energy conversion in OMACON liquid-metal MHD system are investigated. Numerical simulation of two-phase flow in the OMACON system without magnetic field was carried out by the Phoenics code and the energy conversion characteristics are studied in association with the fact that the mechanical energy loss at the nozzle of the OMACON system are to be converted into electrical energy. In this system, working fluid (gas) is injected through the mixer located at the bottom of the riser, and is mixed with hot liquid metal. Therefore in the riser two-phase flow is developed under the influence of the gravity. In this study, the interaction between the gas and liquid is considered by the use of IPSA(InterPhase Slip Algorithm) where standard drag coefficient has been used. It has been assumed that in the flow regime the liquid is continuous and the gas is dispersed. For the liquid and gas, the continuity equations, momentum equations and energy equations are solved respectively in association with void fraction in the flow field. In order to calculate the energy conversion efficiency, firstly the ratio of the mechanical energy loss of liquid metal flow at the nozzle to the input thermal energy is considered. Secondly flow pattern of liquid metal in the generator has been analyzed, and the characteristics of the conversion of the mechanical energy into the electrical energy has been investigated. For an representative case where Hartmann number is 540 and magnetic field is 0.35 T, the present analysis shows that the energy conversion efficiency is 0.653. This result is considered to be reasonable in comparison with published experimental results.

  • PDF

Application Consideration of Machine Learning Techniques in Satellite Systems

  • Jin-keun Hong
    • International journal of advanced smart convergence
    • /
    • v.13 no.2
    • /
    • pp.48-60
    • /
    • 2024
  • With the exponential growth of satellite data utilization, machine learning has become pivotal in enhancing innovation and cybersecurity in satellite systems. This paper investigates the role of machine learning techniques in identifying and mitigating vulnerabilities and code smells within satellite software. We explore satellite system architecture and survey applications like vulnerability analysis, source code refactoring, and security flaw detection, emphasizing feature extraction methodologies such as Abstract Syntax Trees (AST) and Control Flow Graphs (CFG). We present practical examples of feature extraction and training models using machine learning techniques like Random Forests, Support Vector Machines, and Gradient Boosting. Additionally, we review open-access satellite datasets and address prevalent code smells through systematic refactoring solutions. By integrating continuous code review and refactoring into satellite software development, this research aims to improve maintainability, scalability, and cybersecurity, providing novel insights for the advancement of satellite software development and security. The value of this paper lies in its focus on addressing the identification of vulnerabilities and resolution of code smells in satellite software. In terms of the authors' contributions, we detail methods for applying machine learning to identify potential vulnerabilities and code smells in satellite software. Furthermore, the study presents techniques for feature extraction and model training, utilizing Abstract Syntax Trees (AST) and Control Flow Graphs (CFG) to extract relevant features for machine learning training. Regarding the results, we discuss the analysis of vulnerabilities, the identification of code smells, maintenance, and security enhancement through practical examples. This underscores the significant improvement in the maintainability and scalability of satellite software through continuous code review and refactoring.