• 제목/요약/키워드: continuous chromatography

검색결과 85건 처리시간 0.035초

Chlorella protothecoides의 밀킹 전후 연속 배양 시스템을 통한 유용물질 분석 (Analysis of High-Value Materials through Continuous Cultivation System from Pre-and Post-Milking of Chlorella protothecoides)

  • 정유정;김성학;이원영;김성천
    • 한국해양바이오학회지
    • /
    • 제10권2호
    • /
    • pp.73-82
    • /
    • 2018
  • Chlorella are source of valuable compounds as lipids, proteins, carbohydrates, bioactive compounds. To continuous obtain the high-value materials of Chlorella protothecoides, we performed continuous cultivation after applying milking techniques to C. protothecoides grown with culture for 7 days in optical panel bioreactor (OPBR) system. Fatty acid and lutein in extracts from pre- and post-milking of C. protothecoides were analyzed using gas chromatography and high performance liquid chromatography, respectively. C. protothecoides were rich in unsaturated fatty acids with a high content of oleic acid(C18:1), which is suitable as a biofuel feedstock. The fatty acid content in pre- and post-milking of C. protothecoides was decreased from 126.424mg/g d.w. to 119.341mg/g d.w, and the lutein content decreased from 0.258mg/g d.w. to 0.178mg/g d.w. The results of this study demonstrate the feasibility of milking C. protothecoides for production of lipids for biofuels production. It was confirmed that microalgae can continuously obtain lutein present in a trace amount through a continuous culture from milking.

Development of Continuous Flow Microwave Digestion Procedures for Analysis of Trace Metal in Water Using Ion Chromatography

  • Youn Doo Kim;Gae Ho Lee;Hyung Seung Kim;Dong Soo Kim;Kwang Kyu Park
    • Bulletin of the Korean Chemical Society
    • /
    • 제15권9호
    • /
    • pp.786-791
    • /
    • 1994
  • A simple and rapid sample pretreatment process necessary for determination of metal oxides in water was proposed. Samples were injected into the continuous-flow tube installed inside the microwave oven and the treated samples were cooled before entered to the Ion Chromatography (IC) or Inductively Coupled Plasma (ICP). By coupling this microwave digestion system with IC or ICP, a fully automatic analytical procedures may be easily established. In this study, two different types of digestion methods were considered; the open tubing method (OTM) and the restraint tubing method (RTM). The RTM was proved to be 3 times faster in digestion period and 10 times higher in detection range than the OTM. Validation of proposed sample digestion system was carried out by using an ICP. The results showed that both of continuous-flow methods, the OTM and the RTM were comparable in accuracies with the conventional batch-type vessel digestion method.

괄루근으로부터 분리한 다당류의 화학 및 활성

  • 이정규
    • 한국응용약물학회:학술대회논문집
    • /
    • 한국응용약물학회 1993년도 제2회 신약개발 연구발표회 초록집
    • /
    • pp.45-45
    • /
    • 1993
  • 괄루근으로부터 분리된 다당류에 대하여 continuous gel electrophoresis, SDS-Polyacrylamide gel eletrophoresis, ion exchange column chromatography, Hydroxyapatite column chromatography 및 Gel filtration등의 방법을 이용하여 다음과 같은 결과를 얻었다. 1) 황산암모늄 분별침전법에 의한 렉틴의 정제도는 초추출물의 4.85배이며 DEAE Sephadex A-50 column chromatography법에 의한 정제도는 24.17배로 나타났고, 마지막 정제단계인 Sephacryl S-200 gel filtration에 의한 정제도는 47.34배로 나타났다. 2) 정제된 렉틴의 분자량은 60,000da1ton으로 나타났다. 3) 사람의 혈액형에 따른 응집효과는 90-100%로 특이성은 없었다.

  • PDF

SMB 크로마토그래피를 이용한 loxoprofen racemate의 분리

  • 윤태호;김인호
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2003년도 생물공학의 동향(XIII)
    • /
    • pp.549-553
    • /
    • 2003
  • TMB 크로마토그래피의 물질수지식으로부터 SMB 크로마토그래피의 디자인 파라미터들을 계산할 수 있으며, 이를 이용하여 6 칼럼 SMB 크로마토그래피 장치를 디자인하였다. SMB 크로마토그래피 장치는 4개의 multi position rotary valve를 사용하여 연속적으로 각 칼럼으로의 유로를 제어할 수 있으며, 효율적인 SMB 크로마토그래피 장치를 구현할 수 있다. 또한 회분식 실험으로부터 얻어진 $m_2,$ $m_3$ diagram으로부터 SMB 크로마토그래피의 조작에 필요한 파라미터들을 계산할 수 있었다.

  • PDF

SMB 크로마토그래피를 이용한 광학이성질체의 분리

  • 윤태호;박희준;김인호
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2003년도 생물공학의 동향(XII)
    • /
    • pp.506-510
    • /
    • 2003
  • TMB 크로마토그래피의 물질수지식으로부터 SMB 크로마토그래피의 디자인 파라미터들을 계산할 수 있으며, 이를 이용하여 6 칼럼 SMB 크로마토그래피 장치를 디자인하였다. SMB 크로마토그래피 장치는 4개의 multi position rotary valve를 사용하여 연속적으로 각 칼럼으로의 유로를 제어할 수 있으며, 효율적인 SMB 크로마토그래피 장치를 구현할 수 있다. 또한 회분식 실험으로부터 얻어진 $m_2$, $m_3$ diagram으로부터 SMB 크로마토그래피의 조작에 필요한 파라미터들을 계산할 수 있었다.

  • PDF

SMB 크로마토그래피를 이용한 Chiral 화합물의 분리 (Separation of Chiral Compound Using SMB Chromatography)

  • 윤태호;김인호
    • KSBB Journal
    • /
    • 제15권6호
    • /
    • pp.541-547
    • /
    • 2000
  • Simulated moving bed (SMB) chromatography has been investigated in order to separate chiral compounds for pharmaceutical use. SMB utilizes the principle of true moving bed (TMB) chromatography, and has the advantages of low solvent usage, flexible configuration of columns and hardwares, and high productivity of the chiral compounds over the TMB. Large scale separation of xylene isomers and saccharides has been conducted since 1960s. However, the application of SMB in the fine chemical industries is still in the infant stage. The study of SMB for the chiral compounds production was initiated in the mid 1990s and further researches are actively undergoing. This review summarizes the principle of SMB as well as the chemistry of chiral stationary phase and chiral compounds.

  • PDF

이온교환 칼럼 크로마토그래피를 이용한 난백에서 Lysozyme의 연속추출 (Continuous Separation of Lysozyme from Egg White by Ion Exchange Column Chromatography)

  • 박성준;김현석;김현위;안태회;박기문;최춘언
    • 한국식품과학회지
    • /
    • 제22권6호
    • /
    • pp.711-715
    • /
    • 1990
  • 식품 및 의약품 원료로 이용되고 있는 Iysozyme을 난백으로부터 이온교환 크로마토그래프를 이용하여 연속추출하였다. 사용된 수지는 지금까지 수율, 순도, 작동용이성에서 가장 효과적이라고 밝혀져 있는 Duolite C-464 양이온교환수지를 선택하여 $Na^+$형으로 $pH\;7.9{\pm}0.1$로 평형화하여 사용하였다. 조제용 자동 Liquid Chromatography(LC) system(column size ; i.d. 50 mm, bed volumn ; 1020 ml)에서 수지 평형화, 난백접촉, rinse, lysozyme용출 순으로 cycle을 연속적으로 반복하면서 시행하고 그 재현성을 관찰하기 위해 각 cycle별 rinse끝점과 용출끝점의 UV level을 비교하였다. 그 결과 rinse끝점은 19 cycle까지 30% 이하를 유지하였다. 용출 끝점은 17 cycle까지는 30% 이하에서 비교적 안정하였으나 18 cycle 이후 부터는 50% 이상으로 용출능력이 현저하게 감소하였다. 또한, 회수율 비교에서 17cycle까지는 90% 이상을 유지하다가 18cycle에서는 72%, 19 cycle에서는 65%로 격감하였다. 본 추출 정제 lysozyme은 전기영동상 단일 band로 나타났고, densitometer로 측정한 순도는 99% 이상이었다.

  • PDF

광력을 이용한 입자 분리 장치 (Particle Separator using Radiation Force)

  • 김상복;윤상열;김상수;성형진
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2007년도 추계학술대회
    • /
    • pp.55-58
    • /
    • 2007
  • To improve the conventional optical chromatography, the continuous particle separator, the cross-type optical chromatography, is fabricated using micro-channel and fiber optics. A laser beam irradiates into the liquid solution containing particles in the perpendicular to the liquid flow direction. The different sized polystyrene latex micro-spheres, $2.0\;{\mu}m\;{\pm}\;0.02\;{\mu}m$, $5.0\;{\mu}m\;{\pm}\;0.05\;{\mu}m$, and $10.0\;{\mu}m\;{\pm}\;0.09\;{\mu}m$ diameter, are separated in cross-type optical chromatography. The separated particles are delivered to down stream in the micro-channel maintaining the retention distance continuously. The measured retention distances for different sized particles well agree with theoretical predictions.

  • PDF

SMB(Simulated Moving Bed)를 이용한 IgY(Immunoglobulin Yolk) 분리의 전산모사 (Simulation of IgY(Immunoglobulin Yolk) Purification by SMB(Simulated Moving Bed))

  • 송성문;김인호
    • Korean Chemical Engineering Research
    • /
    • 제49권6호
    • /
    • pp.798-803
    • /
    • 2011
  • 난황에 포함된 IgY는 포유동물에 있는 바이러스나 항원에 반응하는 항체와 같은 역할을 한다. IgY 분리를 위해 난황을 전처리한 후 3-zone SMB를 이용하여 지질단백질들로 부터 분리하는 전산모사연구를 수행하였다. 회분식 크로마토그래피와 pulse input method(PIM) 실험을 이용하여 전산모사 매개변수와 흡착 등온식을 얻었다. Aspen simulator를 이용하여 전산모사를 수행하여 IgY를 분리할 수 있는 SMB 운전조건을 다음과 같이 제시할 수 있었다. 삼각형 이론의 $m_2$$m_3$ 값은 각각 0.18, 1.0이고 스위칭 타임은 419 초이었다. 전산모사 결과 raffinate의 IgY 순도가 98.39%이고 두번째 싸이클에서 순도가 정상상태에 도달하였다.

A Study on the Distribution Characteristics of Sulfur Compounds in Ambient air using Continuous Monitoring Method in Incheon Area

  • Seo, Seok-Jun;Lim, Yong-Jae;Hong, You-deok;Park, Geon-Young
    • 통합자연과학논문집
    • /
    • 제8권2호
    • /
    • pp.128-134
    • /
    • 2015
  • This paper focuses on the applicability of a continuous monitoring method on trace sulfur compounds in the ambient air by TD and GC/PFPD. The target compounds for monitoring include H2S(hydrogen sulfide), Methyl mercaptan, Dimethyl Sulfide, and Dimethyl disulfide. The result of QA/QC on monitoring instruments satisfies all the standards of Odor Measurement and Analysis Method, showing that the reproductivity of the compounds by concentration is within 10%, linearity is above 0.98 of a correlation efficient, method detection limit is 0.16 ppb by MM standard, and recovery rate is over 70%. Monitoring was conducted for two years from March 2006 to February 2008. As a result of the monitoring, the average concentration of H2S was 0.08 ppb, with the maximum concentration at 16.15 ppb. The result indicates that it is reasonable to do continuous monitoring as there appears a spontaneous event of high concentration by the condition of the site during monitoring odor-causing substances. Therefore, it is suggested that the continuous monitoring method used in this paper is appropriate to identify the characteristics of sudden occurrence and concentration variations of sulfur compounds.