• 제목/요약/키워드: content flow

검색결과 1,520건 처리시간 0.043초

FRP의 사출성형에 있어서 섬유배향상태와 섬유함유율분포에 관한 연구 (A Study on the Fiber Orientation and Fiber Content Ratio Distribution during the Injection Molding for FRP)

  • 김진우;이동기
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2005년도 춘계학술대회 논문집
    • /
    • pp.252-257
    • /
    • 2005
  • Injection molding is a very important industrial process for the manufacturing of plastics objects. During an injection molding process of composites, the fiber-matrix separation and fiber orientation are caused by the flow of molten polymer/fiber mixture. As a result, the product tends to be nonhomogeneous and anisotropic. Hence, it is very important to clarify the relations between separation' orientation and injection molding conditions. So far, there is no research on the measurement of fiber orientation using image processing. In this study, the effects of fiber content ratio and molding condition on the fiber orientation-angle distributions are studied experimentally. Using the image processing method, the fiber orientation distribution of weld-line in injection-molded products is assessed. And the effects of fiber content and injection mold-gate conditions on the fiber orientation are also discussed.

  • PDF

폴리카본산계 고성능감수제를 사용한 콘크리트의 특성연구 (Study on The Properties of The Concrete with Polycarboxylate Superplasticizer)

  • 오병환;김기완;박대균
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.277-280
    • /
    • 2004
  • Recently, as structure is more higher and bigger, we need high strength and high performance concrete. Therefore it is necessary superplasticizer for high strength and high performance concrete. In this study, it is examined the properties of flow, air content and strength of concrete with polycarboxylate superplasticizer in comparison with existing superplasticizer. First, The slump loss of concrete used polycarboxylate superplasticizer showed 2cm until 120 minutes. Second, The air content loss of concrete used polycarboxylate superplasticizer showed $1\%$ until 120 minutes. Third, It is possible to manufacture $1000kgf/cm^2$ strength concrete using polycarboxylate superplasticizer with $806kg/m^3$ cement content, $18\%$ water-binder ratio, $15\%$ silica fume, $10\%$ fly-ash content.

  • PDF

복합유기섬유를 사용한 고강도 콘크리트의 기초특성 및 폭렬방지 (Fundamental Properties and Spalling Resistance of High Strength Concrete Containing Hybrid Organic fiber)

  • 배장춘;한동엽;이진우;한창평;양성환;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.745-748
    • /
    • 2006
  • This study investigates the fundamental properties and examines spalling appearances and residual compressive strength of high strength concrete containing hybrid organic fibers subjected to fire. Test showed that overall, an increase of fiber content decreased the fluidity of concrete, but specimens containing polyvinyl alcoho(PVA)+polypropylene(PP) fiber and nylon(NY)+PP fiber had improved flow. In addition, the air content of all specimens was properly ranged in target value, regardless of fiber content. As for the spalling properties when completed the fire test, control concrete exhibited spalling occurrence due to sudden elevated temperature. However, specimens containing more than 0.1 vol% of PP fiber prevented the spalling, while specimens containing PP+CL and PVA+PP fiber can protected from fire in more than 0.15vol% of the fiber content. Importantly, a specimen containing only 0.05vol% of NY+PP showed the favorable spalling resistance performance.

  • PDF

호밀가루의 레올로지 특성분석 (Analysis of Rheological Properties of Rye Flour)

  • 이귀현
    • Journal of Biosystems Engineering
    • /
    • 제35권6호
    • /
    • pp.408-412
    • /
    • 2010
  • Rheological properties of cereals such as rye are great important for the design of die for extrusion and the development of models for extrusion process. Therefore, this study was carried out to analyze the rheological properties according to moisture content of rye flour and extrusion temperature. Rheological properties of rye flour were investigated by using a capillary rheometer for moisture content of three levels (30, 35, 40%) and extrusion temperature of three levels (120, 130, $140^{\circ}C$). Determination coefficients for the relationship between apparent shear stress ($\tau_{ap}$) and apparent shear velocity ($\gamma_{ap}$) were relatively high in the range of 0.973 ~ 0.997 under each extrusion condition. The values of consistency index (K) was decreased with increasing moisture content and extrusion temperature. However, the value of flow behavior index (n) presented the highest value at moisture content of 35%, but it was not affected by extrusion temperature.

고분자 전해질 연료전지용 수소극 촉매층의 이오노머 함량 영향 (Effect of Ionomer Content on the Anode Catalyst Layers of PEM Fuel Cells)

  • 박범준;이선호;우승희;박석희;정남기;임성대
    • 한국수소및신에너지학회논문집
    • /
    • 제30권6호
    • /
    • pp.523-530
    • /
    • 2019
  • For the low-Pt electrodes for polymer electrolyte fuel cells (PEMFCs), the optimization of ionomer content for anode catalyst layers was carried out. A commercial catalyst of 20 wt.% Pt/C was used instead of 50 wt.% Pt/C which is commonly used for PEMFCs. The ionomer content varies from 0.6 to 1.2 based on ionomer to carbon ratio (I/C) and the catalyst layer is formed over the electrolyte by the ultrasonic spray process. Evaluation of the prepared MEA in the unit cell showed that the optimal ionomer content of the air electrode was 0.8 on the I/C basis, while the hydrogen electrode was optimal at the relatively high ionomer content of 1.0. In addition, a large difference in cell performance was observed when the ionomer content of the hydrogen electrode was changed. Increasing the ionomer content from 0.6 to 1.0 by I/C in a hydrogen electrode with 0.05 mg/㎠ platinum loading resulted in more than double cell performance improvements on a 0.6 V. Through the analysis of various electrochemical properties in the single cell, it was assumed that the change in ionomer content of the hydrogen electrode affects the water flow between the hydrogen and air electrodes bounded by the membrane in the cell, which affects the overall performance of the cell. A more specific study will be carried out to understand the water flow mechanism in the future, and this study will show that the optimization process of hydrogen electrode can also be a very important cell design variable for the low-Pt and high-performance MEA.

컬러 카메라를 이용한 측면유동 면역 어세이 정량분석 방법 (A Method for Quantitative Measurement of Lateral Flow Immunoassay Using Color Camera)

  • 박종원
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권1호
    • /
    • pp.1-7
    • /
    • 2014
  • Among semi-quantitative or fully quantitative lateral flow assay readers, an image sensor-based instrument has been widely used because of its simple setup, cheap sensor price, and compact equipment size. For all previous approaches, monochrome CCD or CMOS cameras were used for lateral flow assay imaging in which the overall intensities of all colors were taken into consideration to estimate the analyte content, although the analyte related color information is only limited to a narrow wavelength range. In the present work, we introduced a color CCD camera as a sensor and a color decomposition method to improve the sensitivity of the quantitative biosensor system which utilizes the lateral flow assay successfully. The proposed setup and image processing method were applied to achieve the quantification of imitatively dispensed particles on the surface of a porous membrane first, and the measurement result was then compared with that using a monochrome CCD. The compensation method was proposed in different illumination conditions. Eventually, the color decomposition method was introduced to the commercially available lateral flow immunochromatographic assay for the diagnosis of myocardial infarction. The measurement sensitivity utilizing the color image sensor is significantly improved since the slopes of the linear curve fit are enhanced from 0.0026 to 0.0040 and from 0.0802 to 0.1141 for myoglobin and creatine kinase (CK)-MB detection, respectively.

Anti-ischemic Effect of Polygala Tenuifolia in Isolated Rat Heart

  • Kang, Chang-Won;Kim, Jong-Hoon
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제11권3호
    • /
    • pp.89-95
    • /
    • 2007
  • Polygala tenuifolia (PT) is one of the most well-known traditional herbal medicines in Korea which is commonly used for the treatment of cardiovascular symptoms. The anti-ischemic effects of PT in isolated rat heart was investigated by analyzing changes in blood pressure, aortic flow, coronary flow, and cardiac output. And, its underlying mechanism was examined by quantitating intracellular calcium content in rat neonatal cardiomyocytes. Rats were divided into two groups: an ischemia-induced group without any treatment, and an ischemia-induced group treated with PT. Ischemia of isolated heart was induced by stopping the supply of oxygen and buffer for 10 min. The isolated heart was exposed to PT for the first 5 min of 10 min ischemia. PT treatment significantly prevented the decreases of perfusion pressure, aortic flow, coronary flow, and cardiac output under ischemic conditions. In addition, hemodynamics (except heart rate) of the PT-treated group was significantly recovered 60 min after reperfusion compared to the control group (systolic aortic pressure: 83.3% vs. 64.9%, aortic flow volume: 69.5% vs. 48.7%, coronary flow volume: 77.7% vs. 58.4%, and cardiac output: 71.6% vs. 51.2%, p < 0.01). As for the underlying mechanism, PT significantly prevented intracellular calcium increase which was induced by isoproterenol (p < 0.01), suggesting that the anti-ischemic effect of PT is mediated by inhibition of intracellular calcium increase.

Experimental performance characteristics of 1 kW commercial PEM fuel cell

  • Shubhaditya Kumar;Pranshu Shrivastava;Anil Kumar
    • Advances in Energy Research
    • /
    • 제8권4호
    • /
    • pp.203-211
    • /
    • 2022
  • The aim of this paper is to analyze the performance of commercial fuel cell (rated capacity 1000W) with the help of resistive load and output power variation with change in H2 flow rate and calculate the maximum power point (MPP) of the proton exchange membrane (PEM) while changing AC and DC load respectively. The factors influencing the output power of a fuel cell are hydrogen flow rate, cell temperature, and membrane water content. The results show that when the H2 flow rate is changed from 11, 13, and 15 Lpm, MPP is increased from lower to higher flow rate. The power of the fuel cell is increased at the rate of 29% by increasing the flow rate from 11 to 15 lpm. This study will allow small-scale industries and residential buildings (in remote or inaccessible areas) to characterize the performance of PEMFC. Furthermore, fuel cell helps in reducing emission in the environment compared to fossil fuels. Also, fuel cells are ecofriendly as well as cost effective and can be the best alternative way to convert energy.

유튜브 먹방에서 유료광고포함 명시성과 BJ 상호작용성이 플로우 및 제품태도에 미치는 영향 (Effect of explicitness of paid advertisements and BJ interactivity on flow and product attitude in YouTube muk-bang)

  • 박민영;신재익
    • 한국정보시스템학회지:정보시스템연구
    • /
    • 제33권2호
    • /
    • pp.169-189
    • /
    • 2024
  • Purpose The purpose of this study is to identify the influence relationship between BJ interactivity, explicitness of paid advertisements, flow, and product attitude in YouTube muk-bang, and to determine whether there are gender differences in the relationship between them. Design/methodology/approach In this study, an online survey was conducted targeting college students who watch YouTube muk-bang content using a questionnaire form provided by Google. 115 questionnaires were collected from April 1 to 15, 2024, and after excluding 15 insincere responses, a total of 100 questionnaires were used in the final analysis. Findings The results of the empirical analysis are as follows. First, the explicitness of including paid advertising was confirmed to have a significant impact on both flow and product attitude. Second, while BJ interactivity had a significant effect on flow, it was confirmed that it had no significant effect on product attitude. Third, flow was confirmed to have a significant impact on product attitude, and as a result of confirming the moderating effect due to differences between genders in the relationship between the variables set in this study, it was confirmed that there was no moderating effect.

상온하 혈액희석 체외순환에 있어서 혈액 GAS 동태에 관한 실험적 연구 (Experimental Studies of the Blood Gas Transport during Normothermic Hemodilution Perfusion)

  • 박희철
    • Journal of Chest Surgery
    • /
    • 제13권2호
    • /
    • pp.85-91
    • /
    • 1980
  • Extracorporeal circulation by hemodilution technique has been currently used with its clinical safety and good peripheral tissue perfusion in open heart surgery. There is no doubt that $O_{2}$ carrying capacity of the blood is disturbed by decreased hemoglobin level resulting from hemodilution of the circulating blood. From the view point of the blood gas exchange, these experimental studies were undertaken to determined the sate limit of hemodilution in the condition of cardiopulmonary bypass with a constant perfusion flow rate. Twelve adult mongrel dogs weighing 10 to 13 Kg. were anesthetized with pentobarbital and then respiration was controlled with Harvard volume respirator using room air. The cardiopulmonary by pass was performed by use of Sarns heart lung machine (console 5000, 5 head and 2 roller pumps) and Travenol pediatric bubble oxygenator. The perfusion rate during bypass was maintained at a constant rate of 80 ml/min/Kg of body weight. The ratio of oxygen gas flow to blood flow was kept in 3 to 1 constantly. International hemodilution was attained by serial blood withdrawals and immediate infusion of equal volumes of diluants composed of Ringer's lactate, 5% dextrose in water and 25% mannitol solution, proportionally 60%, 30%, and 10%. Arterial and venous blood samples were obtained between 15 and 20 minutes following each hemodilution. Hematocrits and hemoglobin values, $PO_{2}$, $PCO_{2}$ and pH were measured. Oxygen and carbon dioxide contents oxygen consumption and carbon dioxide elimination were calculated groups according to different hematocrit values and the correlations were evaluated. Result were as follows. 1. the arterial $O_{2}$ tension and $O_{2}$ saturation were maintained at the physiological level irrespective of the hematocrit value. 2. The venous $O_{2}$ tension and $O_{2}$ saturation showed a tendency to decline with the decrease in hematocrit value and positive correlation between them (r = +0.49, r = +0.76), The mean values of venous $O_{2}$ tension and $O_{2}$ saturation, however, were not decreased when the hematocrit levels were lower than 20%. 3. The arterial $O_{2}$ content declined lineally in proportion to the fall of hematocrit level with a positive correlation between them (r = +0.95). 4. The venous $O_{2}$ contents were decreased gradually as the hematocrit value decreased with positive correlation between them ( r =+0.89). The trend of diminution of venous $O_{2}$ content, however, was became low according to progressive decrease of hematocrit level. 5. Systemic oxygen consumption was in higher range than $O_{2}$ requirement of basal metabolism when the hematocrit value was above 20%, but abruptly decreased when the hematocrit value became to below 20%. 6. The arterial $CO_{2}$ tension and $CO_{2}$ content showed trend of increasing with progressive decrease of hematocrit value but exhibited a rather broad range and there was no relationship between those value and the hematocrit value. 7. The venous $CO_{2}$ tension and $CO_{2}$ content have also no correlation with change of Ht. value but related directly to those value of arterial blood with positive correlation between them (r = +0.78, r = +0.95_. 8. A-V difference of $CO_{2}$ content and $CO_{2}$ elimination wasnot significantly influenced by Ht. value. From the results, we obtained that feasible limit in inteneional hemodilution is above the hematocrit value of 20% under the given experimental condition.

  • PDF