Study on the Emission Characteristics of Heavy metals in sewage sludge Incinerator (하수슬러지 소각시설의 중금속 배출특성에 관한 연구)

  • Park, Jung-Min;Lee, Sang-Bo;Kim, Min-Jung;Kim, Jin-Pil;Kim, Jong-Chooun;Lee, Suk-Jo;Lee, Sang-Hak
    • Journal of environmental and Sanitary engineering
    • /
    • v.24 no.3
    • /
    • pp.28-36
    • /
    • 2009
  • We have closely examined the concentration change characteristics, emission amounts, and the material balance of hazardous air pollutants at both early and later stages of the prevention facilities. These results will be uses as the basic data when preparing for the regulatory and management plans for hazardous air pollutants. The results of the study on heavy metals illustrated that the content of heavy metals in sludge across five facilities were as follows: copper> zinc> chrome> nickel> cadmium> mercury. In terms of heavy metal content in swage sludge, the sludge in incinerating facilities other than the sludge in the D incinerating facility containing industrial water waste, was examined in order to satisfy the ocean contamination standard and fertilizer specifications. Most of the items were shown to have satisfied the emission tolerance standards in the latter part of the prevention facilities(The average elimination rate was over 90%). Therefore, it is concluded that swage sludge containing high-concentrate heavy metals needs to be incinerated rather than recycled as fertilizer.

High Cadmium Levels in Cured Meat Products Marketed in Nigeria - Implications for Public Health

  • Adejumo, Olufunmilayo E;Fasinu, Pius S;Odion, Judith E;Silva, Boladale O;Fajemirokun, Timothy O
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.4
    • /
    • pp.1933-1936
    • /
    • 2016
  • Heavy metals are known to disrupt important physiological processes in living cells, and have been responsible for various pathological conditions with possible contributions to cancer development. Food contamination have been identified as one of the ways humans are exposed to heavy metals. In developing countries like Nigeria, the regulatory framework for enforcing compliance with globally acceptable exposure to deleterious contaminants is poor. In the current study, thirteen samples of cured meat products of diverse origin marketed in South-west Nigeria were evaluated for lead, cadmium, chromium and nickel contents using the atomic absorption spectroscopy technique. All the samples analysed contained cadmium between 0.35 and 1.20 ppm, levels considered higher than acceptable limits in consumable products. Lead, chromium and nickel were not detected in any of the samples. As known cumulative poisons, there is the need for stringent regulatory control of these heavy metals in cured meat products imported into or produced indigenously in the country in order to minimize the risks to public health.

Epidemiological Evaluation of Breast Cancer in Ecological areas of Kazakhstan - Association with Pollution Emissions

  • Bilyalova, Zarina;Igissinov, Nurbek;Moore, Malcolm;Igissinov, Saginbek;Sarsenova, Samal;Khassenova, Zauresh
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.5
    • /
    • pp.2341-2344
    • /
    • 2012
  • The aim of the research was to evaluate the incidence of breast cancer in the ecological areas of Kazakhstan and assess the potential. A retrospective study of 11 years (1999 to 2009) was conducted using descriptive and analytical methods. The incidence of breast cancer was the lowest in the Aral-Syr Darya area ($18.6{\pm}0.80$/100,000), and highest in the Irtysh area ($48.9{\pm}1.90$/100,000), with an increasing trends over time in almost all areas. A direct strong correlation between the degree of contamination with high pollution emissions in the atmosphere from stationary sources and the incidence of breast cancer ($r=0.77{\pm}0.15$; p=0.026). The results indicate an increasing importance of breast cancer in Kazakhstan and an etiological role for environmental pollution.

INFECTION CONTROL OF LIGHT CURING UNITS (광중합기 사용 시의 감염 조절)

  • Chang, Hoon-Sang
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.4
    • /
    • pp.235-237
    • /
    • 2010
  • When curing the composite restorations with light curing units, the light guides are often in direct contact with oral tissues, therefore contamination of light guides is inevitable. Curing light guides fall into the "semicritical" instrument category according to the Centers for Disease Control and Prevention (CDC) and must be heat or vapor-sterilized or at a minimum, these semicritical instruments must be sterilized in a liquid chemical agent. Currently, most common methods of maintaining sterility of the light guides are wiping the guide with a disinfectant, such as glutaraldehyde, after each patient use; using autoclavable guides; using presterilized, single-use plastic guides; and using translucent disposable barriers to cover the guide.

A Study Regarding Bacterial Contamination of Surfaces in Dental Offices (치과진료실 내 표면 세균 오염에 관한 연구)

  • Yun, Kyoung-Ok;Kim, Hye-Young
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.47 no.4
    • /
    • pp.279-285
    • /
    • 2015
  • This study studied samples taken off surfaces at three sites (Unit chairs, light handles, cuspidors) of 19 dental hospitals and 28 clinics located in Gyeonggi-do and Incheon, South Korea. The bacterial contamination levels of surfaces were $44.82{\times}10^3CFU/mL$ in cuspidors, higher than in unit chairs ($5.47{\times}10^3CFU/mL$) and light handles ($16.28{\times}10^3CFU/mL$). The values were statistically higher at dental hospitals than at dental clinics, the greater number of patients being associated with the higher bacterial cell count in the cuspidors. The results of identifying the strains isolated purely from surfaces at dental clinic showed Gram positive 47.3% and Gram negative 52.7%. Among Gram positive, the most numberous bacteria were Micrococcus luteus (10.9%), Bacillus pumilus (3.6%), and Staphylococcus aureus (3.6%). Among Gram negative, the most numberous bacteria were Acinetobacter ursingii (5.5%), Brevundimonas diminuta (4.5%), Chryseobacterium (Flavo.) indologenes (CDC IIb) (4.5%), and Methylobacterium sp. (4.5%). This study measures the level of bacterial contamination and identifies the strains isolated in dental clinics. It recognizes the importance of infection control, and the results of the study may be considered as the basis for establishing specific plans for prevention of infection.

Prevention of Soil Contamination from Underground Storage Facilities of Petroleum Product and Hazardous Chemical Compounds (유류 및 유해화학물질 저장시설에서의 토양오염 방지대책)

  • 배우근;홍종철;정진욱;김종호
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.4
    • /
    • pp.40-47
    • /
    • 2002
  • The practices of the construction and management of the petroleum and hazardous chemical compound storage facilities in Korea were investigated extensively, and the problems were identified. The advanced technologies in the U.S.A were comparatively studied. Considering the effectiveness of leak prevention and applicability, the following measures were suggested. To prevent corrosion of a tank, a clad tank, an interior lining tank, or a double-wall tank were thought to be the most cost effective. For piping. use of non-metalic materials was suggested. A catchment basin seemed to be effective for preventing spills. For monitoring of leaks, constructions of more than one of detection systems, such as an automatic leak detection device. a vapor detection system, a groundwater monitoring system, or a double-wall monitoring system, were recommended.

DISTRIBUTION OF AIRBORNE BACTERIA BY HANDPIECE AEROSOL CONDITIO (핸드피스 분무조건에 따른 부유세균 기균(氣菌) 의 분포)

  • Ko, Young-Han;Baik, Byeong-Ju;Kim, Jae-Gon;Yang, Yeon-Mi;Shin, Jeong-Geun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.4
    • /
    • pp.628-634
    • /
    • 2008
  • In recent years, cross-contamination has become one of the noticeable issues in dental clinic. Two major routes of contamination are the direct-contamination through blood and oral secretion and the indirect-contamination through dental office equipments. Especially, air-contamination through air-floating pollutant in a confined space like hospital, and also contamination through aerosol ejected from high-speed handpiece in a dental office was interested. The purpose of this study was to understand risk of bacterial infection through aerosol from handpiece in a dental office, which will help the practitioner with prevention of contamination during dental treatment. The main findings are as follows. 1. In a comparative test, the group using handpiece has higher bacterial number than the group not using handpiece with significant statistical difference(P<0.01). 2. The group using handpiece with rubber dam has lower bacterial number than the group using handpiecewithout rubber dam with significant statistical difference(P<0.01). 3. Comparing the group using drainage water with the group using distilled water as a handpiece water source results in 22.4 cfu and 17.0 cfu respectively but the difference is no statistically significant(P>0.05). 4. Measuring cfu at 0.5m and 1.5m distance, 0.5m distance showed higher bacterial number with statistical significance(P<0.01). 5. Classification of bacterial types showed the largest bacterial number came from gram-positive micrococcus(73.9%), and gram-negative micrococcus, gram-negative bacillus, and gram-positive bacillus follow in descending order.

  • PDF

Development of an Electromagnetic Nondestructive Testing Method for the Prevention of Defects in Steam Generator Tubes at Nuclear Power Plant (원자력발전소 증기발생기 전열관의 결함발생 예방을 위한 전자기 비파괴 검사방법 개발)

  • Shin, Young-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.83-85
    • /
    • 1996
  • Major cause of defects in steam generator tubes at nuclear power plant is the accumulation of magnetite and other byproducts of corrosion in the crevice gap between support plates and tubes. Since damaged tubes result in contamination of the secondary coolant by the radioactive primary coolant, they represent a safety hazard. Early detection of magnetite buildup is, therefore, imperative in order to take remedial measures such as chemical flushing. Although the eddy current testing is being used for the inspection of steam generator tubes, the interpretation of resulting signals is generally a difficult task. This paper uses the phase of sensor coil emf as the test signal to find a way of easier signal interpretation. Numerical study using FEM shows that the shape of resulting signal is good for identifying the relative position of the probe to the support plate, and for discreminating the different shapes and degrees of magnetite buildup in the crevice gap region.

  • PDF

Activities of Essential Oils from Perilla frutescens var. acuta against Antibiotic-Susceptible and -Resistant Vibrio and Salmonella Species

  • Lim, Hye-Rim;Shin, Seung-Won
    • Natural Product Sciences
    • /
    • v.17 no.4
    • /
    • pp.296-302
    • /
    • 2011
  • We determined the inhibitory activity of the essential oil fraction obtained by steam distillation from the fresh and dried leaves of Perilla frutescens var. acuta against some pathogenic Salmonella and Vibrio spp. The activities of compounds isolated from the essential oils, apiol and myristicin, were also tested and the results were compared with those of the essential oil fraction. The Perilla essential oil fraction and its main components showed significant inhibition against antibiotic-susceptive and antibiotic-resistant strains of the tested Salmonella and Vibrio strains. Synergistic or additive effects were identified by combing the oils with ampicillin by checkerboard-titer tests. We conclude that essential oils from P. frutescens can be useful in the treatment of Salmonella and Vibrio infections and as safe additives to food materials for the prevention of contamination of food by these bacteria. This is especially important because of the rapid increase in antibiotic-resistant strains, which could cause severe symptoms in humans.

Disinfection Efficacy of an Ultraviolet Light on Film Cassettes for Preventive of the Nosocomial Infection (병원감염 예방을 위한 Film Cassette의 자외선 소독 효과)

  • Kweon, Dae-Cheol;Jeon, Yong-Woong;Cho, Am
    • Journal of radiological science and technology
    • /
    • v.24 no.1
    • /
    • pp.27-32
    • /
    • 2001
  • The bacteria infection on film cassette contact surface was examined at the diagnostic radiology department of the S. hospital. The objective of this study was to assess the contamination level on film cassette contact surface as a predictor of patient prevention from nosocomial infection and for improvement of the hospital environment. The laboratory result was identified non-pathologic bacterial in the five different cassette size of the contact surface. Film cassettes were exposed to ultraviolet light for 1, 2 and 3 minutes. Ultraviolet light disinfection is proven suitable for bacteria. The study concludes that presence of a bacterial infection will prevent a using antiseptic technique on film cassette contact surface. In addition education of nosocomial infection for radiographers will be required. In conclusion, ultraviolet is considered effective to irradate bacteria. Additionally, two minutes are required to sterilize film cassettes.

  • PDF