• 제목/요약/키워드: contamination electron

검색결과 156건 처리시간 0.024초

6 MeV 전자선의 물팬텀 속의 선량분포에 관한 모의계산 (The Simulation on Dose Distributions of the 6 MeV Electron Beam in Water Phantom)

  • 이정옥;정동혁;문성록
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제23권2호
    • /
    • pp.75-79
    • /
    • 2000
  • This study was performed for the clinical applications applying the Monte Carlo methods. In this study we calculated the absorbed dose distributions for the 6 MeV electron beam in water phantom and compared the results with measured values. The energy data of electron beam used in Monte Carlo calculation is the energy distribution for 6 MeV electron beam which is assumed as a Gaussian form. We calculated percent depth doses and beam profiles for three field sizes of $10{\times}10,\;15{\times}15$, and $20{\times}20\;cm^2$ in water phantom using Monte Carlo methods and measured those data using a semiconductor detector and other devices. We found that the calculated percent depth doses and beam profiles agree with the measured values approximately. However, the calculated beam profiles at the edge of the fields were estimated to be lower than the measured values. The reason for that result is that we did not consider the angular distributions of the electrons in phantom surface and contamination of X-rays in our calculations. In conclusion, in order to apply the Monte Carlo methods to the clinical calculations we are to study the source models for electron beam of the linear accelerator beforehand.

  • PDF

투과전자현미경에 타소질 불순물의 오염 최소화를 위한 실험 조건 (Experimentally Minimized Contaminative Condition of Carbonaceous Artifacts in Transmission Electron Microscope)

  • 김영민;최주형;송경;김양수;김윤중
    • Applied Microscopy
    • /
    • 제39권1호
    • /
    • pp.73-77
    • /
    • 2009
  • Contaminative artifacts such as carbonaceous materials on carbon-coated microgrids are unavoidable, which is induced by electron beam exposure inside electron microscopes. This phenomenon raise a source to produce confusing information to the samples investigated by analytical TEM, which should be alleviated as much as possible. As experimental precautions for reducing this unwanted effect, the use of $LN_2$ cooled anti-contaminator and pre-illumination of electron beam at low magnification can be helpful. Nevertheless, we should be cautious to set an illumination condition for microanalysis because the contaminative effect is dependent with the types of irradiation situations, which is well known to be a decisive factor for causing the carbonaceous artifacts. Accordingly, it is necessary that optimal illumination to minimize the contaminative effect should be selected for improving the accuracy of microanalysis. In this paper, we introduce the practical method to determine the optimal illumination condition by evaluating the contaminative effect as a function of instrumental spot size, which is directly linked with electron current density.

Assessment of Microbial and Radioactive Contaminations in Korean Cold Duck Meats and Electron-Beam Application for Quality Improvement

  • An, Kyung-A;Jo, Yunhee;Arshad, Muhammad Sajid;Kim, Gui-Ran;Jo, Cheorun;Kwon, Joong-Ho
    • 한국축산식품학회지
    • /
    • 제37권2호
    • /
    • pp.297-304
    • /
    • 2017
  • Animal-origin food products pose serious threat to public food safety due to high microbial loads. The microbial and radioactive contaminations in commercial cold duck meat products were evaluated. Ten different lots of commercial samples ($C_1-C_{10}$) were classified based on type and smoking process. All samples were highly contaminated (< 4-7 Log CFU/g) with total aerobic bacteria (TAB), yeasts and molds (Y&M), and 7 samples ($C_1-C_7$) were positive for coliforms. Furthermore, three samples were contaminated with Listeria monocytogenes ($C_4-C_6$) and one with Salmonella typhimurium ($C_6$). No radionuclides ($^{131}I$, $^{137}Cs$, and $^{134}Cs$) were detected in any sample. The results of DEFT (direct epifluorescent filter technique)/APC (aerobic plate count), employed to screen pre-pasteurization treatments of products, indicated that smoked samples were positive showing DEFT/APC ratios higher than 4. Notably, the samples showed a serious threat to microbial safety, thus were irradiated with electron-beam (e-beam). The $D_{10}$ values for S. typhimurium and L. monocytogenes were 0.65 and 0.42 kGy, respectively. E-beam application at 3 and 7 kGy resulted in reduction of initial TAB, Y&M, and coliform populations by 3 and 6 log cycles, respectively. Thus, e-beam was proven to be a good decontamination approach to improve the hygiene of cold duck meat.

금속 유지장치의 오염이 레진 접착 결합력에 미치는 영향 (The effect of contamination of the etched matal retainer on resin bonding strength)

  • 박하옥;방몽숙
    • 구강회복응용과학지
    • /
    • 제18권3호
    • /
    • pp.217-224
    • /
    • 2002
  • The purpose of this study was to evaluate the influence of saliva contamination on the resin bonding of the etched metal retainers. The test samples were made of Verabond, and divided into 3 groups. Retainers in group1 had normally etched metal surfaces. Retainers in group2 had normally etched metal surfaces which were saliva-contaminated for 30 seconds and cleaned with streaming, luke-warm for 1 minute and dried thoroughly. Retainers in group3 had normally etched metal surfaces which were saliva- contaminated for 30 seconds and dried thoroughly without water-cleansing. Each 3 group specimen was watched on SEM. A resin core, 5mm in diameter and 6mm in length, was made of Panavia using Teflon mold on the each specimen. These 3 groups were tested to evaluate shear bond strength, using universal testing machine. The results were as follows : 1. The shear bond strength showed no significant difference between group1 and group2. 2. The shear bond strength showed significant difference between group1 and group3. 3. The shear bond strength significant difference between group2 and group3. 4. Scanning electron microscope photographs of group1 and group2 showed no signs of contamination but of group3 showed somewhat contaminated.

Heterotrophic Bacterial Growth on Hoses in a Neonatal Water Distribution System

  • Buffet-Bataillon, Sylvie;Bonnaure-Mallet, Martine;De La Pintiere, Armelle;Defawe, Guy;Gautier-Lerestif, Anne Lise;Fauveau, Severine;Minet, Jacques
    • Journal of Microbiology and Biotechnology
    • /
    • 제20권4호
    • /
    • pp.779-781
    • /
    • 2010
  • After preliminary tests indicated an increased number of heterotrophic bacteria, we investigated possible sources of contamination in a neonatal intensive care unit (NICU) water distribution system. Scanning electron microscopic examination of flexible metallic hoses associated with the system revealed the presence of a biofilm; partial 16S rDNA sequencing revealed that the biofilm contained Blastomonas natatoria. Purgation of the water system three times a day, reinforced faucet cleaning, decreasing the cold water temperature to $12^{\circ}C$, and six repeated chlorinations at concentrations as high as 2 mg/l were not sufficient to eradicate the bacterial contamination. Replacing all of the rubber-interior flexible metallic hoses with teflon-lined hoses, followed by heating the water to $70^{\circ}C$, successfully controlled the bacteria.

6MV 전자 선형 가속기 광자선의 전자오염 (Contamination of the 6MV Linear Accelerator Photon Beam by Electrons)

  • 유명진;김동원;정운혁
    • Journal of Radiation Protection and Research
    • /
    • 제13권1호
    • /
    • pp.21-30
    • /
    • 1988
  • 부산의대 부속 병원의 전자선형가속기 (Mevatron 67) 장치를 이용 하여 표면선량의 원인이 되는 광자선의 전자오염에 대한 연구를 하였다. 표면선량은 조사야의 크기에 따라 증가하는 경향을 나타내었다. 빔내에 트레이를 설치했을 때와 트레이를 제거했을때 표면선량의 변화와 전자오염정도를 관찰하였다. 전자오염을 감소시키기 위해서 구리 필터를 트레이 밑에 부착하여 그 효과를 분석하였다. 아울러 거리를 변화 시켜가며 선량의 변화를 관찰하여 최대의 피부보호효과를 유지할 수 있는 최적의 SSD와 TSD를 구하였다. 이런 모든 결과들은 방사선 치료 환자의 피부보호에 이용될 것이다.

  • PDF

Effect of Blood Contamination on Vickers Microhardness and Surface Morphology of Mineral Trioxide Aggregate

  • Jaehyun Seung;Seong-Jin Shin;Byounghwa Kim;Ji-Myung Bae;Jiyoung Ra
    • 대한소아치과학회지
    • /
    • 제51권2호
    • /
    • pp.165-175
    • /
    • 2024
  • This study aimed to investigate the effects of blood contamination on the Vickers hardness and the surface morphology of premixed MTA and compare them with the effects on conventional MTA. The Vickers microhardness of Endocem MTA Premixed Regular (EP) and ProRoot MTA (PM) was assessed after immersion in fetal bovine serum (FBS) and saline. Stem cells from human exfoliated deciduous teeth (SHED) were seeded on MTA after immersion in FBS, saline, and deionized water (DW). Cell adhesion patterns and surface morphology were visualized via scanning electron microscopy (SEM). The surface microhardness of EP and PM in FBS was lower than in saline. However, short-term exposure of PM to FBS did not reduce the microhardness compared to saline. Angular crystals formed in water, while rounded crystals with more air voids appeared in FBS. Favorable SHED attachment occurred in all groups. Overall, the surface hardness of EP and PM decreased after FBS exposure, although PM was less influenced. We suggest minimizing the amount of bleeding when using MTA clinically; nevertheless, PM remains an option with more expected blood contamination than EP. In summary, exposure to FBS decreased mechanical performance but allowed cell adhesion for both MTAs, with PM being more resistant to these changes.

실리콘 실험실에 구리 오염을 방지 할 수 있는 고밀도/고균일의 Solder Bump 형성방법 (Fabrication Method of High-density and High-uniformity Solder Bump without Copper Cross-contamination in Si-LSI Laboratory)

  • 김성진;주철원;박성수;백규하;이희태;송민규
    • 마이크로전자및패키징학회지
    • /
    • 제7권4호
    • /
    • pp.23-29
    • /
    • 2000
  • 사용되는 metal구분 없이 반도체 공정장비들을 사용함으로써 cross-contamination을 유발시킬 수 있다. 특히, copper(Cu)는 확산이 쉽게 되어 cross-contamination에 의해 수 ppm정도가 wafer에 오염되더라도 트랜지스터의 leakage current발생 요인으로 작용할 수 있기 때문에 Si-IC성능에 치명적인 영향을 미칠 수 있는데, Si-LSI 실험실에서 할 수 있는 공정과 Si-LSI 실험실을 나와 할 수 있는 공정으로 구분하여 최대한 Si-LSI 장비를 공유함으로써 최소한의 장비로 Cu cross-contamination문제를 해결할 수 있다. 즉, 전기도금을 할 때 전극으로 사용되어지는 TiW/Al sputtering, photoresist (PR) coating, solder bump형성을 위한 via형성까지는 Si-LSI 실험실에서 하고, 독립적인 다른 실험실에서 Cu-seed sputtering, solder 전기도금, 전극 etching, reflow공정을 하면 된다. 두꺼운 PR을 얻기 위하여 PR을 수회 도포(multiple coaling) 하고, 유기산 주석과 유기산 연의 비를 정확히 액 조성함으로서 Sn:Pb의 조성비가 6 : 4인 solder bump를 얻을 수 있었다. solder를 도금하기 전에 저속 도금으로 Cu를 도금하여, PR 표면의 Cu/Ti seed층을 via와 PR표면과의 저항 차를 이용하여 PR표면의 Cu-seed를 Cu도금 중에 etching 시킬 수 있다. 이러한 현상을 이용하여 선택적으로 via만 Cu를 도금하고 Ti층을 etching한 후, solder를 도금함으로써 저 비용으로 folder bump 높이가 60 $\mu\textrm{m}$ 이상 높고, 고 균일/고 밀도의 solder bump를 형성시킬 수 있었다.

  • PDF

Laboratory-scale Microcosm Studies in Assessing Enhanced Bioremediation Potential of BTEX and MTBE under Various Electron Acceptors in Contaminated Soil

  • 오인석;이시진;장순웅
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.368-371
    • /
    • 2003
  • Accidental release of petroleum products from underground storage tank(USTs) is one of the most common causes of groundwater contamination. BTEX is the major components of fuel oils, which are hazardous substances regulated by many nations. In addition to BTEX, other gasoline consituents such as MTBE(methyl-t-buthyl ether), anphthalene are also toxic to humans. Natual attenuation processes include physic, chemical, and biological trasformation. Aerobic and anaerobic biodegradation are believed to be the major processes that account for both containment of the petroleum-hydrocarbon plum and reduction of the contaminant concentrations. Aerobic bioremediation has been highly effective in the remediation of many fuel releases. However, Bioremediation of aromatic hydrocarbons in groundwater and sediments is ofen limited by the inability to provide sufficient oxygen to the contaminated zones due to the low water solubility of oxygen. Anaerobic processes refer to a variety of biodegradation mechanisms that use nitrate, ferric iron, sulfate, and carbon dioxide as terminal electron accepters. The objectives of this study was to conduct laboratory-scale microcosm studies in assessing enhanced bioremediation potential of BTEX and MTBE under various electron accepters(aerobic, nitrate, ferric iron, sulfate) in contaminated Soil. these results suggest that, presents evidence and a variety pattern of the biological removal of aromatic compounds under enhanced nitrate-, Fe(III)-, sulfate-reducing conditions.

  • PDF

혈액오염이 Tricalcium Silicate 재료의 압출강도와 표면형태에 미치는 영향 (Effect of Blood Contamination on the Push-Out Bond Strength and Surface Morphology of Tricalcium Silicate Materials)

  • 박미선;김재환;최남기;김선미
    • 대한소아치과학회지
    • /
    • 제43권1호
    • /
    • pp.36-43
    • /
    • 2016
  • 이 연구의 목적은 혈액오염 시 Biodentine$^{(R)}$, Theracal$^{(R)}$, mineral trioxide aggregate(MTA)의 압출강도를 측정하고 표면형태를 관찰하는 것이었다. Biodentine$^{(R)}$, Theracal$^{(R)}$, MTA 각각의 재료를 2개의 그룹으로 나누었다. 대조군은 phosphate buffered saline 용액 조건에서, 실험군은 fetal bovine serum 조건에서 4일간 $37^{\circ}C$에서 보관하였다. 이후 압출강도를 측정하고 주사전자현미경을 이용하여 표면형태를 분석하였다. Biodentine$^{(R)}$과 Theracal$^{(R)}$은 모든 조건에서 MTA보다 유의하게 더 높은 압출강도를 보였고 혈액오염 시 모든 재료의 압출강도는 유의하게 감소하였다. 표면형태 관찰결과 혈액오염 후 모든 재료의 표면형태가 변화하였다. 혈액오염 조건에서 Biodentine$^{(R)}$과 Theracal$^{(R)}$은 MTA와 비교하여 더 높은 압출강도를 보였으므로 혈액오염 조건에 사용하기에 더 적절할 수 있다.