• Title/Summary/Keyword: contamination detection

Search Result 440, Processing Time 0.034 seconds

Application of the Detection of External Contamination on Radiation Workers for Bed Type Whole Body Counting Using Monte Carlo Method (몬테카를로 방법을 적용한 bed type 전신계측기의 방사선작업종사자 외부오염 검출 응용)

  • Kim, Jeong-In;Lee, Byoung-Il
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.242-245
    • /
    • 2013
  • Monte Carlo method was applied to discriminate the external contamination on radiation workers in nuclear power plants for internal dose assessment generally used with a bed type scanning detector whole body counter. Korean voxel model with internal contamination was used to estimate the detection patterns of whole body scanning. Also, the BOMAB model with various external contamination was assumed to compare with detection of radionuclides inside the human body. From the comparison of detection efficiency between front and back side up, external contamination was easily distinguished.

A Study on Oil's Contamination Detection System using Optical Fiber Sensor (광섬유 센서를 이용한 오일 오염도 검사시스템 연구)

  • Song, Doo-Sang;Hong, Jun-Hee;Ryu, Sang-Hyun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.4
    • /
    • pp.541-546
    • /
    • 2012
  • This study investigates the detection system of oil pollution level using single optical fiber sensor. This study focus on sensing of oil pollution by moisture and iron powder which are representatives of oil pollution factor. In addition, It is placed that the water and iron powder as an oil pollution factor in the oil tank which is the oil circulation in. The oil pollution detection system was measured by the changing of intensity of light and sensing gap. The result of this experimentation not only confirmed the contamination by moisture volume in the oil tank from the section 190ppm to 540ppm, but also monitored the contamination by iron volume from the section 1200ppm to 3500ppm. This study confirmed effectiveness of this detection system using optical fiber sensor. There is expectations of measuring another section by various optical fiber sensor.

A Study of the Device Development for the Contamination Detection in the Delivery Line (유체배관 오염 검출장치 개발에 관한 연구)

  • Jeong, Yi Ha;Kim, Byung Han;Hong, Joo-Pyo
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.1
    • /
    • pp.45-49
    • /
    • 2015
  • Process gases with vapor or liquid phase as well as gas phase may experience alteration in itself or be contaminated in the fluid pipe to the process chamber. And thus it result in as particles or defects on the substrates in semiconductor, LCD, LED manufacturing. Purifiers and filters are used for control of contamination. However, none of detection device is available in the delivery line. In this paper, we propose simple device with lighting and sensing in order to predict contamination of the fluid or the tube wall. For some general purpose gases, it showed constant voltage output regardless of the flow rates. But, the smoke and the moisture in the air lowered the figure due to its concentration. Numerical values for several solid and liquid media were obtained. And, the operating temperature tendency was investigated.

CHARACTERIZATION OF METALLIC CONTAMINATION OF SILICON WAFER SURFACES FOR 1G DRAM USING SYNCHROTRON ACCELERATOR

  • Kim, Heung-Rak;Kun-Kul, Ryoo
    • Journal of the Korean institute of surface engineering
    • /
    • v.32 no.3
    • /
    • pp.239-243
    • /
    • 1999
  • At Present, 200mm wafer technology is being applied for commercial fabrications of 64, 128, and 256 M DRAM devices, and 300mm technology will be evolved for 1G DRAM devices in the early 21th century, recognizing limitations of several process technologies. In particular recognition has been realized in harmful effects of surface contamination of trace metals introduced during devicing processes. Such a guide line for surface metal contamination has been proposed as 1E9 and 1E10 atoms/$\textrm{cm}^2$ of individual metal contamination for wafering and devicing of 1G DRAM, respectively, and so its measurement limit should be at least 1E8 atoms/$\textrm{cm}^2$. The detection limit of present measurement systems is 2E9 atoms/$\textrm{cm}^2$ obtainable with TRXFA(Total Reflection X-Ray Fluorescence Analysis). TRXFA is nondestructive and the simplest in terms of operation, and it maps the whole wafer surfaces but needs detection improvement. X-Ray intensity produced with synchrotron accelerator is much higher than that of conventional X-ray sources by order of 4-5 magnitudes. Hence theoretically its reactivity with silicon surfaces is expected to be much higher than the conventional one, realizing improvement of detection limit. X-ray produced with synchrotron accelerator is illuminated at a very low angle with silicon wafer surfaces such as 0.1 degree and reflects totally. Hence informations only from surface can be collected and utilized without overlapping with bulk informations. This study shows the total reflection phenomenon and quantitative improvement of detection limit for metallic contamination. It is confirmed that synchrotron X-ray can be a very promising alternative for realizing improvement of detection limit for the next generation devices.

  • PDF

Contamination of Listeria spp. in Market Beef (국내 시판 쇠고기의 Listeria spp. 오염)

  • 구동환;정충일;정동관;남은숙
    • Journal of Food Hygiene and Safety
    • /
    • v.10 no.2
    • /
    • pp.89-95
    • /
    • 1995
  • Highly lethal Listeria monocytogenes, causing bromatoxism through vegetables, dairy products, meat products and shellfish etc, was examined for possible contamination in market beef. USDA, FDA, Malthus and Modified Cold Enrichment methods were used for the detection of Listeria spp.. Samples of domestic and imported market beef were collected from local meat shopsat Seoul, Korea. Total two hundreds and six of Listeria spp. were isolated and identified from beef. Among 206 isolates, the number of L. welshimeri was one hundred and twenty-one(44.8%). The numbers of isolated L. innocua, L. murrayi, L. monocytogenes, L. grayi, L. seeligeri, and L. ivanovii were 49(18.1%), 14(5.2%), 12(4.4%), 6(2.2%), 2(0.7%), and 2(0.7%), respectively. Detection rates of Listeria spp. varied among four methods. The highest detection rate of Listeria spp. in market beef was found at USDA method and that of L. monocytogenes was found at Malthus method.

  • PDF

Spectroscopic Techniques for Nondestructive Detection of Fungi and Mycotoxins in Agricultural Materials: A Review

  • Min, Hyunjung;Cho, Byoung-Kwan
    • Journal of Biosystems Engineering
    • /
    • v.40 no.1
    • /
    • pp.67-77
    • /
    • 2015
  • Purpose: Fungal secondary metabolite (mycotoxin) contamination in foods can pose a serious threat to humans and animals. Spectroscopic techniques have proven to be potential alternative tools for early detection of mycotoxins. Thus, the aim of this review is to provide an overview of the current developments in nondestructive food safety testing techniques, particularly regarding fungal contamination testing in grains, focusing on the application of spectroscopic techniques to this problem. Methods: This review focuses on the use of spectroscopic techniques for the detection of fungi and mycotoxins in agricultural products as reported in the literature. It provides an overview of the characteristics of the main spectroscopic methods and reviews their applications in grain analysis. Results: It was found that spectroscopy has advantages over conventional methods used for fungal contamination detection, particularly when combined with chemometrics. These advantages include the rapidness and nondestructive nature of this approach. Conclusions: While spectroscopy offers many benefits for the detection of mycotoxins in agricultural products, a number of limitations exist, which must be overcome prior to widespread adoption of these techniques.

Detection of Tobamoviruses and Survey on Contamination Rate in Commercial Pepper Seeds Using Gelatin Particle Agglutination Test (젤라틴입자응집반응법을 이용한 국내 시판 고추종자의 Tobamovirus 검출 및 오염률 조사)

  • 한정헌;장태호;이철호;김영호;나용준
    • Research in Plant Disease
    • /
    • v.7 no.3
    • /
    • pp.170-174
    • /
    • 2001
  • Gelatin particle agglutination test (GPAT) was optimized for detection of Tobamovirus and contamination of the virus in commercial pepper seeds was evaluated. The optimum concentration of ${\gamma}$-globulin G, specific to tobacco mosaic virus pepper strain, was 100 ug/ml. The sensitivity of GPAT for the detection of Tobamovirus in pepper seeds was as high as enzyme-linked immunosorbent and dot immunoblotting assays. Optimum dilution ranges of the seed extract for GPAT was 5-25 folds. Using the optimized GPAT with above conditions, the rate of Tobamovirus contamination in seeds was turned out to be average of 79.1%.

  • PDF

Geophysical Applications on the Soil-contamination Mapping and Detection of Buried Mine Tailings in the Abandoned Mine Area (폐광산의 토양오염영역 및 폐기된 광미의 탐지)

  • Lee, Sang Kyu;Hwang, Se Ho;Lee, Tai Sup
    • Economic and Environmental Geology
    • /
    • v.30 no.4
    • /
    • pp.371-377
    • /
    • 1997
  • This paper presents the geophysical applications to the environmenml problem in an abandoned mine area. We would like to focus our attention on the mapping of the soil contamination and the detection of the buried mine tailings. For mapping the soil contamination. measurements of both in-situ magnetic susceptibility (k) and terrain conductivity were carried out. In-situ magnetic susceptibilities of the contaminated soil due to the acid mine drainage show higher values than those of the uncontaminated area. However. those data do not show the correlation with the degree of the soil contamination observed on the surface. The least-squares fitted formula obtained with the measured insitu magnetic susceptibilities is $k=4.8207{\times}W^{0.6332}$, where W is the $Fe^{+2}$ weight percentage. This weight gives most effect to magnetic susceptibility of the soil. Lateral variations of the soil contamination in the shallow subsurface can be detected by the electrical conductivity distributions from EM induction survey. TDIP (Time Domain Induced Polarization) and EM induction surveys were conducted to detect the buried mine tailings. From the results of TDIP, the spatial zone, which shows high chargeability-low resistivity, is interpreted as the buried mine tailings. Therefore, it is concluded that it is possible to discriminate the spatial zone from the uncontaminated ground.

  • PDF

Microbiological Contamination of Fresh-Red Pepper and Packaged-Red Pepper Powder in South Korea

  • Jeong, A-Ram;Jo, Mi-Jin;Koo, Min-Seon;Oh, Se-Wook;Ku, Kyung-Hyung;Park, Jae-Bok;Kim, Hyun-Jung
    • Preventive Nutrition and Food Science
    • /
    • v.15 no.3
    • /
    • pp.233-238
    • /
    • 2010
  • The aim of this study was to determine microbiological contamination of fresh-red pepper and packaged-red pepper powder commercially available in South Korea. Thirty-seven fresh-red peppers were collected from 5 farms and 31 packaged-red pepper powders were purchased from retail markets in South Korea. Foodborne pathogens (Escherichia coli, Salmonella spp., Listeria monocytogenes, Staphylococcus aureus and Bacillus cereus), total viable counts, Enterobacteriaceae, coliforms, yeast and mold, and Aspergillus flavus were determined. Detection percentage of contamination of Bacillus cereus in fresh-red pepper was 8.1%, which was lower than the 39% of detection rate in packaged-red pepper powder. The contamination level of Bacillus cereus was 1~3 log CFU/g in packaged-red pepper powder. Escherichia coli was detected in 5.4% of fresh-red pepper samples and was not detected in packaged-red pepper powder. Enterobacteriaceae and coliforms were detected in both of fresh-red pepper and packaged-red pepper powders. Foodborne pathogens, except Bacillus cereus and Escherichia coli, were not detected.

Monitoring Technique and Device of Surface Contamination for Line-Post Insulator (지지애자의 표면오염 모니터링 기술 및 장치)

  • Kil, Gyung-Suk;Park, Dae-Won;Jung, Kwang-Seok;Kim, Sun-Jae;Seo, Dong-Hoan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.5
    • /
    • pp.413-417
    • /
    • 2010
  • Line to ground faults by deterioration of insulators has frequently occurred in power system, and the main cause is surface contamination of the insulators. The contamination of insulator is analyzed by monitoring the surface leakage current flowing them. The suspension insulator is monitored by installation of a zero-phase current sensor(ZCT), but the line-post insulator is impossible to apply the same method because of its large diameter structure. This paper proposed a detection method of surface leakage current for a line-post insulator, and it can easily be applied to new and/or built insulators. The leakage current is indirectly calculated from the potential difference between the metal electrode attached on the surface of insulator and the ground connector. To evaluate the performance of the proposed method, the leakage current is compared as a function of contamination condition controlled by the density of NaCl solution. The leakage current is proportioned to the density of NaCl solution, and the voltage detected by the electrode showed the same trend. From the experimental results, we designed and fabricated a monitoring device which is composed of a detection electrode, signal converter, microprocessor, and ZigBee, and its measurement range is $10{\mu}A{\sim}5mA$.