• Title/Summary/Keyword: contamination degree

Search Result 338, Processing Time 0.024 seconds

Physicochemical Characteristics of Tailings from the Various Types of Mineral Deposits (광상유형에 따른 광물찌꺼기의 물리화학적 특성)

  • Lee, Pyeong-Koo;Youm, Seung-Jun;Jung, Myung-Chae;Lee, Jin-Soo;Kwon, Hyun-Ho
    • Economic and Environmental Geology
    • /
    • v.43 no.3
    • /
    • pp.235-248
    • /
    • 2010
  • To construct the standard methods for evaluation of physicochemical characteristics of tailings in Korea, specific gravity, paste pH, grain size, mineral compositions and heavy metal concentrations of total 26 tailings from 21 metallic mines were analyzed. Specific gravity of tailings ranged from 2.61 to 4.31 (avg. 3.04), and sand and silt grain were dominant in the tailings. Ranges of paste pH were 2.1-9.5 in tailings (7.1-9.2 at magmatic, skarn and hydrothermal replacement deposits and 2.1-9.5 at hydrothermal vein deposits). Additionally, hydrothermal vein deposits could be reclassified into three categories: (1) paste pH>7.0, (2) 4.0

Petrochmical study on the Volcanic Rocks Related to Depth to the Benioff Zone and Crustal Thickness in the Kyongsang Basin, Korea: A Review (경상분지 화산암류의 지화학적 연구. 섭입대(베니오프대)의 깊이와 지각의 두께)

  • Jong Gyu Sung
    • Economic and Environmental Geology
    • /
    • v.32 no.4
    • /
    • pp.323-337
    • /
    • 1999
  • Late Cretaceous to early Tertiary volcanic rocks in the Kyongsang basin exhibit high-K calc-alkaline characteristics, and originated from the magmatism related genetically to subduction of Kula-Pacific plate. They represent HFSE depletion and LlLE enrichment characteristics as shown by magmas related to subduction. Early studies on the depth of magma generation has been estimated as 180-230 km based on K-h relation should be reevaluated, because the depth of peridotite partial melting with 0.4 wt. % water is 80-120 km at subduction zone, and subducting slab in premature arc can melted even lower than 70 km. Moreover the increase of potassium contents depends on either contamination of crustal material and fluids of subducting slab or low degree of partial melting. If the inclination of subduction zone is 30 degrees and the depth to the Benioff zone is 180-230 km, the calculated distance between the volcanic zone and trench axis would be 310-400 km. It is unlikely because the distance between the Kyongsang basin and trench during late Cretaceous to early Tertiary is closer than this value and not comparable with generally-accepted models in subduction zone magmatism. $K_{55}$ of the volcanics in the Kyongsang basin is 0.3-2.3 wt.% and the average indicate that the depth ranges between 80-170 km on the diagram of Marsh, Carmichael (1974). Fractionation from garnet lherzolite, assumed the depth of 180-230km, is not consistent with the REE patterns of the volcanoes in the Kyongsang basin. Futhermore, the range of depth suggested by many workers, who studied magmatism related to subduction, imply shallower than this depth. Crustal thickness calculated by the content of CaO and $Na_2O$ is about 30 km and about 35 km, respectively. Paleo-crustal thickness during late Cretaceous to early Tertiary times in the Kyongsang basin inferred about 30 km calculated by La/Sm versus LaJYb data, which is also supported by many previous studies.

  • PDF

Evaluation of Food Safety Performance and Food Storage Condition in Restaurants against Climate Change (기후변화 대응 식품접객업소 식재료 안전관리 수행도 및 보관실태에 관한 연구)

  • Lee, Jung-Su;Bae, Young-Min;Yoon, Jae-Hyun;Kim, Bo-Ram;Yoo, Jin-Hee;Hyun, Jeong-Eun;Jung, Soon-Young;Cha, Myung-Hwa;Ryu, Kyung;Park, Ki-Hwan;Lee, Sun-Young
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.3
    • /
    • pp.195-201
    • /
    • 2014
  • This study was conducted to investigate the current status of hygiene performance and food preparation/storage condition in restaurants during the summer season in order to evaluate the sanitary management systems in restaurants against climate change. Total 30 restaurants located in Gyeonggi participated in a survey in which they were asked current hygiene performance, food preparation/storage condition, and purchasing practices for 5 food ingredients. As results, regarding the performance degree of respondents on food hygiene management, the average scores of 9 questions were well over 4 points. However, only 6.83% of the respondents claimed that they use sanitizers (chlorine) to disinfect food ingredients. About food storage condition, a high proportion of respondents said that they store food materials in plastic bags or airtight containers following pretreatment and use refrigerator for the storage of pretreated food materials. However, 5.55% and 14.85% of respondents answered that they store pretreated food materials in the kitchen or inside of dining room, respectively. Respondents (21.50%) answered that they store pretreated food materials for more than 6 hours before cooking. Therefore, food materials need to be disinfected properly with sanitizer to remove microbial contamination and stored at refrigerator using closed bags or containers before cooking in order to prevent foodborne disease in restaurants especially during summer season.

Progress of Composite Fabrication Technologies with the Use of Machinery

  • Choi, Byung-Keun;Kim, Yun-Hae;Ha, Jin-Cheol;Lee, Jin-Woo;Park, Jun-Mu;Park, Soo-Jeong;Moon, Kyung-Man;Chung, Won-Jee;Kim, Man-Soo
    • International Journal of Ocean System Engineering
    • /
    • v.2 no.3
    • /
    • pp.185-194
    • /
    • 2012
  • A Macroscopic combination of two or more distinct materials is commonly referred to as a "Composite Material", having been designed mechanically and chemically superior in function and characteristic than its individual constituent materials. Composite materials are used not only for aerospace and military, but also heavily used in boat/ship building and general composite industries which we are seeing increasingly more. Regardless of the various applications for composite materials, the industry is still limited and requires better fabrication technology and methodology in order to expand and grow. An example of this is that the majority of fabrication facilities nearby still use an antiquated wet lay-up process where fabrication still requires manual hand labor in a 3D environment impeding productivity of composite product design advancement. As an expert in the advanced composites field, I have developed fabrication skills with the use of machinery based on my past composite experience. In autumn 2011, the Korea government confirmed to fund my project. It is the development of a composite sanding machine. I began development of this semi-robotic prototype beginning in 2009. It has possibilities of replacing or augmenting the exhaustive and difficult jobs performed by human hands, such as sanding, grinding, blasting, and polishing in most often, very awkward conditions, and is also will boost productivity, improve surface quality, cut abrasive costs, eliminate vibration injuries, and protect workers from exposure to dust and airborne contamination. Ease of control and operation of the equipment in or outside of the sanding room is a key benefit to end-users. It will prove to be much more economical than normal robotics and minimize errors that commonly occur in factories. The key components and their technologies are a 360 degree rotational shoulder and a wrist that is controlled under PLC controller and joystick manual mode. Development on both of the key modules is complete and are now operational. The Korean government fund boosted my development and I expect to complete full scale development no later than 3rd quarter 2012. Even with the advantages of composite materials, there is still the need to repair or to maintain composite products with a higher level of technology. I have learned many composite repair skills on composite airframe since many composite fabrication skills including repair, requires training for non aerospace applications. The wind energy market is now requiring much larger blades in order to generate more electrical energy for wind farms. One single blade is commonly 50 meters or longer now. When a wind blade becomes damaged from external forces, on-site repair is required on the columns even under strong wind and freezing temperature conditions. In order to correctly obtain polymerization, the repair must be performed on the damaged area within a very limited time. The use of pre-impregnated glass fabric and heating silicone pad and a hot bonder acting precise heating control are surely required.

A Study on the Sanitation Condition for Products of Powdered Raw Grains and Vegetables (곡류 가공품 등의 위생실태에 관한 조사 연구)

  • Cho, Bae-Sick;Gang, Gyung-Lee;Lee, Hyang-Hee;Ha, Dong-Ryong;Kee, Hye-Young;Seo, Kye-Won;Kim, Eun-Sun;Park, Jong-Tae
    • Journal of Food Hygiene and Safety
    • /
    • v.22 no.4
    • /
    • pp.273-278
    • /
    • 2007
  • Recently, the demand for the powdered products to process raw grains and vegetables has been expanded, and the growth possibility of their fields(markets) in the future will be highly valued with the westernization of living environment and the change of the dietary life. We have bought and analyzed the 111 products of raw grains and vegetables from the large-sized marts, markets and internet orders from March to October 2006. The rate of moisture content was $1.7{\sim}12.5%$. We also found out that the foods over 10% moisture content was 8 of those samples we bought or collected. Their ash rates were averagely $0.3{\sim}8.6%$. The number of those foods that the alien substances were detected was 2. The tar pigments, artificial sweeteners and sulfur dioxides of components that contained food additives were not detected. Each detection range of Cadmium, Lead and Arsenic of the injurious heavy metals was non-detectable $(nd){\sim}0.55,\;nd{\sim}4.52,\;nd{\sim}0.10mg/kg$, while the average detection content were 0.08, 0.48, 0.01 mg/kg. By investigating the contamination degree of the microflora, we discovered that the number of the aerobic plate count, B. cereus over 1,000 cfu/g and C. perfringens over 100 cfu/g was 36 (32.4%), 9 (8.1%) and zero, and that the whole sanitation condition of the products of powdered raw grains and vegetables circulated in the market was not so good.

Oil Fluorescence Spectrum Analysis for the Design of Fluorimeter (형광 광도계 설계인자 도출을 위한 기름의 형광 스펙트럼 분석)

  • Oh, Sangwoo;Seo, Dongmin;Ann, Kiyoung;Kim, Jaewoo;Lee, Moonjin;Chun, Taebyung;Seo, Sungkyu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.4
    • /
    • pp.304-309
    • /
    • 2015
  • To evaluate the degree of contamination caused by oil spill accident in the sea, the in-situ sensors which are based on the scientific method are needed in the real site. The sensors which are based on the fluorescence detection theory can provide the useful data, such as the concentration of oil. However these kinds of sensors commonly are composed of the ultraviolet (UV) light source such as UV mercury lamp, the multiple excitation/emission filters and the optical sensor which is mainly photomultiplier tube (PMT) type. Therefore, the size of the total sensing platform is large not suitable to be handled in the oil spill field and also the total price of it is extremely expensive. To overcome these drawbacks, we designed the fluorimeter for the oil spill detection which has compact size and cost effectiveness. Before the detail design process, we conducted the experiments to measure the excitation and emission spectrum of oils using five different kinds of crude oils and three different kinds of processed oils. And the fluorescence spectrometer were used to analyze the excitation and emission spectrum of oil samples. We have compared the spectrum results and drawn the each common spectrum regions of excitation and emission. In the experiments, we can see that the average gap between maximum excitation and emission peak wavelengths is near 50 nm for the every case. In the experiment which were fixed by the excitation wavelength of 365 nm and 405 nm, we can find out that the intensity of emission was weaker than that of 280 nm and 325 nm. So, if the light sources having the wavelength of 365 nm or 405 nm are used in the design process of fluorimeter, the optical sensor needs to have the sensitivity which can cover the weak light intensity. Through the results which were derived by the experiment, we can define the important factors which can be useful to select the effective wavelengths of light source, photo detector and filters.

Analysis of Bacterials Community Structure in Leadchate-Contaminated Groundwater using Denaturing Gradient Gel Electrophoresis (Denaturing Gradient Gel Electrophoresis를 이용한 매립지 침출수로 오염된 지하수의 세균 군집 분석)

  • Kim Jai-Soo;Kim Ji-Young;Koo So-Yeon;Ko Kyung-Seok;Lee Sang-Don;Cho Kyung-Suk;Koh Dong-Chan
    • Microbiology and Biotechnology Letters
    • /
    • v.34 no.2
    • /
    • pp.166-173
    • /
    • 2006
  • This research has been performed to clarify the relationship between hydrogeochemistry and bacterial community structure in groundwater contaminated with landfill leachate. We collected and analyzed samples from 5 sites such as leachate (KSG1-12), treated leachate (KSG1-16), two contaminated groundwaters (KSG1-07 and KSG1-08) and non-contaminated groundwater (KSG1-13). pH was 8.83, 8.04, 6.87, 6.87 and 6.53 in order; redox potential (Eh) 108, 202, 47, 200 and 154 mV; electric conductivity (EC) 3710, 894, 1223, 559 and 169.9 $\mu$S/cm; suspended solids (SS) 86.45, 13.74, 4.18, 0.24 and 11.91 mg/L. In KSG01-12, the ion concentrations were higher especially in $Cl^-$ and $HCO_3^-$ than other sites. The concentrations of Fe, Mn and $SO_4^{2-}$ were higher In KSG1-07 than in KSG1-08, and vise versa in $NO_3^{2-}$. In the comparison of DGGE fingerprint patterns, the similarity was highest between KSG1-13 and KSG1-16 (57.2%), probably due to common properties like low or none contaminant concentrations. Otherwise KSG1-08 showed lowest similarities with KSG1-13 (25.8%) and KSG1-12 (27.6%), maybe because of the degree of contamination. The most dominant bacterial species in each site were involved in $\alpha$-Proteobacteria (55.6%) in KSG1-12, $\gamma$-Proteobacteria (50.0%) in KSG1-16, $\beta$-Proteobacteria (66.7%) in KSG1-07, $\gamma$-Proteobacteria (54.5%) in KSG1-08 and $\beta$-Proteobacteria (36.4%) in KSG1-13. These results indicate that the microbial community structure might be changed according to the flow of leachate in grounderwater, implying changes in concentrations of pollutants, available electron accepters and/or other environmental conditions.

Trace element Analysis and Source Assessment of Apartment Parking Lot Dust in Daegu, Korea (공동주택 주차장의 축적먼지 중 미량원소성분 분석과 오염원 평가)

  • Bae, Gun-Ho;Jung, Cheol-Su;Park, Kyu-Tae;Lee, Myoung-Sook;Shin, Dong-Chan;Kim, Yong-Hye;Yoon, Min-Hye;Han, Young-Jin;Choi, Hyuek;Baek, Sung-Ok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.10
    • /
    • pp.756-766
    • /
    • 2011
  • In order to investigate the degree of apartment parking lot dust contamination, total 72 samples of parking lot dust (36 from ground parking lots and 36 from the underground parking lots) were collected in Daegu city from the end of March to the early June 2010. The dust samples were sieved below $100{\mu}m$, and analysed by ICP for 14 elements after an acid extraction. Results obtained from the source assessment of trace element using enrichment factor showed that Fe, K, Mg, Mn, Na and V were influenced by natural sources, while Cd, Cr, Cu, Ni, Pb and Zn were influenced by anthropogenic sources in both the ground parking lot and the underground parking lot. And results showed that Ca were influenced by natural sources in the ground parking lot, but influenced by anthropogenic sources in the underground parking lot. The measured values were remarkably higher in components from natural sources than in components from anthropogenic sources. Underground parking lot dust was more affected by anthropogenic sources and contaminated compared with the ground parking lot dust. Pollution index of heavy metals revealed that underground parking lot dust was 5.5 times more contaminated with heavy metal components than the ground parking lot dust. The results of correlation analysis among trace elements indicated that components in the ground parking lot were more correlated than those in the underground parking lot, and especially more correlated with natural sources-natural sources. Analysis for correlations between components and influencing factors in the underground parking lot showed that concentrations of heavy metals were higher with smaller number of parking spaces and no ventilation system, and older apartments in last paint and cleaning had relatively higher contents of heavy metals than those of recently painted and cleaned.

Trace Element Analysis and Source Assessment of Household Dust in Daegu, Korea (대구지역 일반주택의 축적먼지 중 미량원소성분 분석과 오염원 평가)

  • Do, Hwa-Seok;Song, Hee-Bong;Jung, Yeoun-Wook;Yoon, Ho-Suk;Kwak, Jin-Hee;Han, Jeong-Uk;Kang, Hye-Jung;Phee, Young-Gyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.1
    • /
    • pp.69-78
    • /
    • 2010
  • In order to investigate the degree of household dust contamination, 48 samples of household dust (24 from urban area and 24 from rural area) in Daegu city were collected in vacuum cleaner during January to February 2009. Samples were sieved below 100 ${\mu}m$, and 14 elements (Al, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, V, Zn) were analyzed using ICP after acid extraction. Results obtained from the source assessment of trace elements using enrichment factor showed that Ca, Fe, K, Mg, Mn, Na, and V were influenced by natural sources such as weathered rock and resuspended soil, while Cd, Cr, Cu, Ni, Pb and Zn were influenced by anthropogenic sources such as fuel combustion and waste incineration. Concentrations were remarkably higher in components from natural sources than in components from urban anthropogenic sources. Household dust in urban area was more affected by anthropogenic sources compared with that of rural area. Pollution index of heavy metals revealed that urban area was 1.8 times more contaminated with heavy metal components than rural area. The correlation analysis among trace elements indicated that components were correlated with natural sources-natural sources (Al-Mg, Al-Mn, Fe-Mn) and natural sources-anthropogenic sources (Al-V, Fe-Cr, V-Mn) in both urban area and rural area. Trace element components of rural area were more correlated than those of urban area. Houses that use oil for heating fuel had relatively higher contents of heavy metals rather than those using gas or electricity for heating fuel. Houses with children also had higher contents of heavy metals. In addition, the age of houses was found to influence the heavy metal levels in household dusts, with older houses (>10years) having higher concentrations than newer houses (<10years) and houses located near the major road (<10 m) were found to have relatively higher heavy metal levels in household dust.

Preliminary Diagnosis of Fishing Ground Environment for Establishing the Management System in Fisheries Resources Protection Area (수산자원보호구역 관리체제 구축을 위한 어장환경 예비진단)

  • Lee, Dae-In;Park, Dal-Soo;Jeon, Kyeong-Am;Eom, Ki-Hyuk;Park, Jong-Soo;Kim, Gui-Young
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.15 no.2
    • /
    • pp.79-89
    • /
    • 2009
  • For preliminary diagnosis on current fishing ground environment and basic information for establishment of effective and rational management policy in fisheries resources protection area, water and sediment quality and changes of total area in the 10 marine protection areas designated for fisheries resources management in Korea were assessed. Results showed that environmental quality in these areas has been degraded by pollution sources, coastal utilization and development stress, etc. The pattern and degree of contamination differed by protection areas, suggesting that it is necessary for optimum environmental management plan considering the regional characteristics. The total designated area of protection areas in 2003 changed by $-22.9{\sim}2.4%$, on average -6.4%, compared with the first year of designation; Wando-Doam Bay showd the highest increase rate (2.4%), and Hansan Bay has the highest decrease rate (-22.9%) Decrease rate of land and sea in total area showd 6.1% and 6.6%. An integrated management of environmental data in protection areas is required for systematic assessment. Therefore, the suitable environmental and information management is needed specifically considering the environment characteristics such as development and utilization conditions of land and sea area Furthermore, bemuse urbanization and industrialization threats the junctions of the protection areas, authorized ministry (MIFAFF) should develope and establish monitoring and management procedures based on the related laws.

  • PDF