• 제목/요약/키워드: contact structure

검색결과 1,794건 처리시간 0.03초

A NOTE ON THE FINITE-DIMENSIONAL ODD CONTACT SUPERALGEBRA OVER A FIELD OF PRIME CHARACTERISTIC

  • Hong, Weidong;Xu, Xiaoning
    • 대한수학회보
    • /
    • 제58권5호
    • /
    • pp.1129-1147
    • /
    • 2021
  • This paper aims to analyze the PTG module for the finite-dimensional odd Contact superalgebra over a field of prime characteristic by using the method of Hu and Shen's mixed product realization. The general acting law in odd Contact superalgebra is obtained. In addition, the structure and irreducibility of graded module for odd Contact superalgebra are discussed.

차단기와 모선과의 연결시 가터스프링에 의한 접촉력의 측정 및 설계 고찰 (Measurement and Design Review of Contact Force by Garter Spring in Connection between Circuit Breaker and Bus Bar)

  • 조상순;안길영;박우진;오일성
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.942-945
    • /
    • 2002
  • A garter spring, which is a long. special, close-coiled extension spring with its ends joined to form a ring, is used in connection between vacuum circuit breaker and bus bar in switchgear. To carry short-time current and resist welding at the contact surface in the connection, the garter spring must transmits an uniform contact force to the contact surface through the contact chips arranged in the circumference of bus bar. In this paper, the system for measurement of the contact force by the garter spring is developed. Using the developed measurement system, the design of the connection structure including the garter spring is reviewed to obtain the uniform contact forces in all of contact chips.

  • PDF

Privacy Analysis and Comparison of Pandemic Contact Tracing Apps

  • Piao, Yanji;Cui, Dongyue
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제15권11호
    • /
    • pp.4145-4162
    • /
    • 2021
  • During the period of epidemic prevention and control, contact tracing systems are developed in many countries, to stop or slow down the progression of COVID-19 contamination. However, the privacy issues involved in the use of contact tracing apps have also attracted people's attention. First, we divide contact tracing techniques into two types: Bluetooth Low Energy (BLE) based and Global Positioning System (GPS) based techniques. In order to clear understand the system structure and its elements, we create data flow diagram (DFD) of each types. Second, we analyze the possible privacy threats contained in various types of contact tracing apps by applying LINDDUN, which is a threat modeling technique for personal information protection. Third, we make a comparison and analysis of various contact tracing techniques from privacy point of view. These studies can facilitate improve tracing and security performance to contact tracing apps through comparisons between different types.

Over 8% efficient nanocrystal-derived Cu2ZnSnSe4 solar cells with molybdenum nitride barrier films in back contact structure

  • Pham, Hong Nhung;Jang, Yoon Hee;Park, Bo-In;Lee, Seung Yong;Lee, Doh-Kwon
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.426.2-426.2
    • /
    • 2016
  • Numerous of researches are being conducted to improve the efficiency of $Cu_2ZnSnSe_4$ (CZTSe)-based photovoltaic devices, which is one of the most promising candidates for low cost and environment-friendly solar cells. In this work, we concentrate on the back contact of the devices. A proper thickness of $MoSe_2$ in back contact structure is believed to enhance adhesion and ohmic contact between Mo back contact and absorber layer. Nevertheless, too thick $MoSe_2$ layers that are grown during high-temperature selenization process can impede the current collection, thus resulting in low cell performance. By applying molybdenum nitride as a barrier in back contact structure, we were able to control the thickness of $MoSe_2$ layer, which resulted in lower series resistance and higher fill factor of CZTSe devices. The phase transformation of Mo-N binary system was systematically studied by changing $N_2$ concentration during the sputtering process. With a proper phase of Mo-N fabricated by using an adequate partial pressure of $N_2$, the efficiency of CZTSe solar cells as high as 8.31% was achieved while the average efficiency was improved by about 2% with respect to that of the referent cells where no barrier layer was employed.

  • PDF

Wheel Bearing Unit의 구조해석을 위한 경계조건 설정에 관한 연구 (Evaluation of Boundary Conditions for Structural Analysis of Wheel Bearing Units)

  • 김기훈;유영면;임종순;현준수
    • 한국자동차공학회논문집
    • /
    • 제8권6호
    • /
    • pp.230-237
    • /
    • 2000
  • The wheel bearing in vehicles has been improved to unit module by joining a bearing to a hub in order to achieve weight reduction and easy assembly. Currently, the contact force between a raceway and balls of a bearing is applied as the external force in order to analyse the structure of the unit type bearings. In this paper, simplified boundary conditions are discussed for structure analysis of wheel bearing unit. From the procedure, the contact conditions of balls and race in wheel bearing unit are considered as equivalent non-linear spring elements. The end node of a spring element is constrained in displacement. And the external force of boundary conditions is applied at the contact point between tire and road. For the evaluation of this analysis, its results for the force of spring elements are compared with contact forces of calculated results. and also maximum equivalent stresses of analysis are compared with results of test at the flange of inner ring. The analysis results with proposed boundary conditions are more accurate than results from analysis which is generally used.

  • PDF

펜타센 박막의 두께와 전극위치가 펜타센 TFT 성능에 미치는 영향 (Effects of Pentacene Thickness and Source/Drain Contact Location on Performance of Penatacene TFT)

  • 이명원;김광현;송정근
    • 대한전자공학회논문지SD
    • /
    • 제39권12호
    • /
    • pp.1001-1007
    • /
    • 2002
  • 된 논문에서는 펜타센을 활성층으로 사용하는 유기박막트랜지스터(OTFT)의 펜타센의 두께, 그리고 소오스 및 드레인 전극의 위치에 따른 소자의 성능 변화에 대하여 연구하였다. 펜타센 박막의 두께가 증가하면 그레인 상태가 박막상태에서 벌크상태로 변화하면서 결정도가 악화되어 성능이 열화하였고, 소오스와 드레인 전극을 펜타센 위에 제작한 소자의 경우 접촉저항은 감소하였으나 누설전류가 증가하여 전류 점멸비가 감소하였다. 그러므로, 펜타센의 두께는, 300Å∼700Å 내외, 그리고 전극은 펜타센 아래에 위치하는 것이 적합한 것으로 확인되었다.

회색 관계 분석법을 이용한 누수 방지용 밸브 시트 설계 (Valve Seat Design for Full Contact Effect Using Grey Relational Analysis)

  • 이정희;강경아;곽재섭
    • 한국기계가공학회지
    • /
    • 제17권4호
    • /
    • pp.17-22
    • /
    • 2018
  • A glove valve regulates the flow in a pipeline as a kind of control valve. However, when the disc and seat contact, the valve structure can be distorted and flow can leak due to the elongation of the valve material under high pressure. The surface texture is not good enough to seal the contact surface (in practice) because the lapping process is usually done manually. Furthermore, assembly performance is analyzed by structural analysis. Compared with a standard seat, the newly designed seat had a smaller radial deformation and a larger longitudinal deformation. Therefore, the newly designed seat can maintain a tight and uniform contact with the disc with a reduced radial deformation and an expanded available seal area with an increased longitudinal deformation. The seal performance of the glove valve has been improved in a cost-effective manner.

FCEV용 고압연료탱크 메탈씰링 파이프의 체결특성 해석 (Analysis on Fitting Characteristics of a Metal-Sealing Pipe of the Hydrogen Fuel Tank for FCEV)

  • 이정민;정화정;전문수;이형욱
    • 소성∙가공
    • /
    • 제27권1호
    • /
    • pp.54-59
    • /
    • 2018
  • In connecting parts of a hydrogen fuel cell vehicle, since the rubber ring is permeable to hydrogen, it is necessary to use a metal sealing structure which ensures leakage stability. Finite element analysis was performed to verify the fitting characteristics of the metal sealing structure, which is used to connect the pipe to a high pressure hydrogen FCEV tank. Deformation shape, contact distance and axial load were compared experimentally and these values were in agreement with each other. In the contact surface, between the pipe and the fitting body, the stress at the edge of the contact surface was higher than the center point, which was considered to be a good characteristic in view point of the leakage. The location of the contact points has almost no change in the upper part of the fitting, but that of the lower parts move downward as the fastening amount increases. The contact pressure at the lower part is maintained at the same constant level.

탠덤형 자석 소호기를 사용한 760V급 직류 개폐기의 차단 특성 (760 V-Class DC Switch Breaking Characteristics Using Tandem Type Magnet Extinguisher)

  • 김효성
    • 전력전자학회논문지
    • /
    • 제27권3호
    • /
    • pp.175-179
    • /
    • 2022
  • Magnetic arc extinguishing technology is effective as an extinguishing device for low-voltage direct current (DC) circuit breakers with a resistive load of ≤4 kW. The separation distance between the magnet and the electrical contact must be shortened to increase the magnetic arc extinguishing force. However, if the magnet is installed too close to the electrical contact points, the magnet is exposed to high temperatures due to the arc current generated when the load current is cut off and the magnetism is lost. To solve this problem, the effective magnetic flux density at the electrical contact can be maintained high by placing the arc extinguishing magnet in a tandem structure with the electrical contact point between them, and the proper separation distance between the contact points and the magnet can be maintained. In addition, an electric arc extinguishing technology that emits arc energy using a series circuit of diode and resistor is used to suppress the continuous arc voltage generated by the inductive load. For the proposed circuit breaker, the breaking characteristics are analyzed through the breaking test for the DC load of the 760 V level, the load power of 4 kW, and the time constant of 5 ms, and an appropriate arc extinguishing design guideline is proposed.