• 제목/요약/키워드: contact ratio

검색결과 1,195건 처리시간 0.031초

이온 이온주입한 p-type 4H-SiC에의 오믹 접촉 형성 (Formation of Ohmic Contacts on acceptor ion implanted 4H-SiC)

  • 방욱;송근호;김형우;서길수;김상철;김남균
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.290-293
    • /
    • 2003
  • Ohmic contact characteristics of Al ion implanted n-type SiC wafer were investigated. Al ions implanted with high dose to obtain the final concentration of $5{\times}10^{19}/cm^3$, then annealed at high temperature. Firstly, B ion ion implanted p-well region were formed which is needed for fabrication of SiC devices such as DIMOSFET and un diode. Secondly, Al implanted high dose region for ohmic contact were formed. After ion implantation, the samples were annealed at high temperature up to $1600^{\circ}C\;and\;1700^{\circ}C$ for 30 min in order to activate the implanted ions electrically. Both the inear TLM and circular TLM method were used for characterization. Ni/Ti metal layer was used for contact metal which is widely used in fabrication of ohmic contacts for n-type SiC. The metal layer was deposited by using RF sputtering and rapid thermal annealed at $950^{\circ}C$ for 90sec. Good ohmic contact characteristics could be obtained regardless of measuring methods. The measured specific contact resistivity for the samples annealed at $1600^{\circ}C\;and\;1700^{\circ}C$ were $1.8{\times}10^{-3}{\Omega}cm^2$, $5.6{\times}10^{-5}{\Omega}cm^2$, respectively. Using the same metal and same process of the ohmic contacts in n-type SiC, it is found possible to make a good ohmic contacts to p-type SiC. It is very helpful for fabricating a integrated SiC devices. In addition, we obtained that the ratio of the electrically activated ions to the implanted Al ions were 10% and 60% for the samples annealed at $1600^{\circ}C\;and\;1700^{\circ}C$, respectively.

  • PDF

고삼(苦蔘) 추출물이 접촉피부염이 유발된 생쥐의 피부에 미치는 영향 (Effects of Sophorae Radix on skin condition in mice with contact dermatitis induced by Dinitrofluorobenzene)

  • 김형우;류정현;조수지;천원주;손용해;안원근;조수인
    • 대한본초학회지
    • /
    • 제28권6호
    • /
    • pp.25-29
    • /
    • 2013
  • Objectives : The dried root of Sophora flavescens Aiton have been used to treat patient with skin diseases such as eczema in Eastern countries. S. flavescens can clear away heat and dry dampness and purge sthenic-fire from the liver and gallbladder. Recently, anti-allergic effect of S. flavescens has been reported. However, the effect on skin condition of contact dermatitis still remains unknown. Thus, the purpose of this study is to evaluate the efficacy of S. flavescens on contact dermatitis. Methods : In order to investigate the effects of S. flavescens (methanol extract of S. flavescens, MESR) on skin condition, the contact dermatitis was induced in mice skin by using 1-fluoro-2,4-dinitrofluorobenzene (DNFB). As the effective endpoints, skin thickness, skin weight, histopathological change were checked. In addition, effects on skin lesion, body weight and spleen/body weight ratio were also investigated. Results : Topical application of MESR ($500{\mu}g/day$) lowered skin thickness (P < 0.05) and skin weight (P < 0.05), respectively. MESR-treated group showed diminished spongiosis and immune cell infiltration in skin tissues compared to those of non-treated control group. The inhibition of skin lesions was also observed in MESR-treated group. In addition, MESR did not affect body weight gain and spleen/body weight ratio in contrast with those in dexamethasone-treated group. Conclusion : These data suggest that Sophorae Radix could improve skin lesion of contact dermatitis. This indicates the possibility for Sophorae Radix to be used to patients with skin diseases such as contact dermatitis.

A Study on the Measurement for the Nano Scale Film Formation of Ultra Low Aspect Ratio

  • Jang Siyoul;Kong Hyunsang
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2004년도 학술대회지
    • /
    • pp.283-288
    • /
    • 2004
  • The measurement of ultra low aspect ratio fluid film thickness is very crucial technique both for the verification of lubrication media characteristics and for the clearance design in many precision components such as MEMS, precision bearings and other slideways. Many technologies are applied to the measurement of ultra low aspect ratio fluid film thickness (i.e. elastohydrodynamic lubrication film thickness). In particular, in-situ optical interferometric method has many advantages in making the actual contact behaviors realized with the experimental apparatus. This measurement method also does the monitoring of the surface defects and fractures happening during the contact behavior, which are delicately influenced by the surface conditions such as load, velocity, lubricant media as well as surface roughness. Careful selection of incident lights greatly enhances the fringe resolutions up to $\~1.0$ nanometer scale with digital image processing technology. In this work, it is found that coaxial aligning trichromatic incident light filtering system developed by the author can provide much finer resolution of ultra low aspect ratio fluid film thickness than monochromatic or dichromatic incident lights, because it has much more spectrums of color components to be discriminated according the variations of film thickness. For the measured interferometric images of ultra low aspect ratio fluid film thickness it is shown how the film thickness is finely digitalized and measured in nanometer scale with digital image processing technology and space layer method. The developed measurement system can make it possible to visualize the contact deformations and possible fractures of contacting surface under the repeated loading condition.

  • PDF

기계 조인트의 전단 컨택 특성 측정 (Measurement of Shear Contact Characteristics on Mechanical Joints)

  • 이철희
    • 한국소음진동공학회논문집
    • /
    • 제18권8호
    • /
    • pp.849-855
    • /
    • 2008
  • 다양한 조임 조건에서 기계적 조인트의 컨택 특성 파라미터를 유도하기 위하여 컨택 공진을 기반으로 하는 실험적 방법을 개발하였다. 기계적 조인트의 전단 컨택 강성과 감쇠의 파라미터는 접촉 표면간의 표면 처리, 윤활 유무, 그리고 조임력과 전단력의 의한 영향과 같은 여러 가지 물리적 조인터 파라미터와 연계하여 고찰하였다. 제안된 실험적 방법을 사용하여 전단 컨택 강성 값은 조임력과 전단력이 커짐에 따라 증가하는 것을 발견하였다. 또한 컨택 감쇠 비 값은 대부분 조임력과 상관없이 일정 값을 나타내지만 전단력이 커짐에 따라 감소하였다. 추가로, 전단 강성 값과 컨택 감쇠 비는 매끄러운 표면에서보다 거친 표면에서 더 크게 나타남을 알 수 있었다.

Contact analysis of spherical ball and a deformable flat model with the effect of tangent modulus

  • Sathish Gandhi, V.C.;Ramesh, S.;Kumaravelan, R.;Thanmanaselvi, M.
    • Structural Engineering and Mechanics
    • /
    • 제44권1호
    • /
    • pp.61-72
    • /
    • 2012
  • The paper is on contact analysis of a spherical ball with a deformable flat, considering the effect of tangent modulus on the contact parameters of a non-adhesive frictionless elastic-plastic contact. The contact analysis of this model has been carried out using analysis software Ansys and Abaqus. The contact parameters such as area of contact between two consecutive steps, volume of bulged material are evaluated from the formulated equations. The effect of the tangent modulus is considered for determining these parameters. The tangent modulus are accounted between 0.1E and 0.5E of materials E/Y value greater than 500 and less than 1750. Result shows that upto an optimal tangent modulus values the elastic core push up to the free surface in the flat. The simulation is also carried out in Abaqus and result provide evidence for the volume of bulged material in the contact region move up and flow into the free surface of the flat from the contact edge between the ball and flat. The strain energy of the whole model is varied between 20 to 40 percentage of the stipulated time for analysis.

등온가열에 의한 접촉융해의 초기 과도과정에 대한 근사적 해석해 (An approximate analytical solution for the initial transient process of close-contact melting on an isothermal surface)

  • 유호선
    • 대한기계학회논문집B
    • /
    • 제21권12호
    • /
    • pp.1710-1719
    • /
    • 1997
  • An approximate analytical solution for the initial transient process of close-contact melting occurring between a phase change material kept at its melting temperature and an isothermally heated flat surface is derived. The model is so developed that it can cover both rectangular and circular cross-sectional solid blocks. Normalization of simplified model equations in reference to the steady solution enables the solution to be expressed in a generalized form depending on the liquid-to-solid density ratio only. A selected result shows an excellent agreement with the previously reported numerical data, which justifies the present approach. The solution appears to be capable of describing all the fundamental characteristics of the transient process. In particular, dependence of the solid descending velocity oft the density ratio at the early stage of melting is successfully resolved. The effects of other parameters except the density ratio on the transient behaviors are efficiently represented via the steady solution implied in the normalized result. A simple approximate method for estimating the effect of convection on heat transfer across the liquid film is also proposed.

n-GaAs의 V/III족 비율에 따른 오믹 저항 연구 (A study on the Ohmic contact resistance as function of V/III ratio of n-GaAs)

  • 김인성;김상택;김선훈;기현철;고항주;김회종;전경남;김효진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.25-26
    • /
    • 2008
  • Electrical properties of Pt/Ti/Au/Pt contacts to n-GaAs were characterized as the V/III ratio of GaAs grown by metalorganic chemical vapor deposition were 25, 50, and 100, respectively. The samples have been annealed during 30sec at 350 and $450^{\circ}C$ in rapid thermal annealing, and those specific contact resistance investigated by using transmission line method. According to experimental results, the specific contact resistance between p-metal and GaAs was decreased as the V/III ratio was lower. These results indicate that Si doping concentration of GaAs increased as the vacancy of V-series of GaAs was high.

  • PDF

레이저 회절 측정기를 이용한 벤츄리 캐비테이션에서의 마이크로버블 발생 특성 연구 (Study on Micro-bubble Generation Characteristics in Venturi Cavitation using Laser Diffractometer)

  • 임윤규;양해정;김영일
    • 드라이브 ㆍ 컨트롤
    • /
    • 제16권1호
    • /
    • pp.1-6
    • /
    • 2019
  • The use of micro bubbles in industrial fields has been increasing in the recent years., particularly micro-bubble sterilization and water purification effects. Various methods have been developed for the generation of micro-bubbles. Depending on the method of generating bubbles, the micro-bubbles can be roughly classified into saturation molding, cavitation and rotation flow types. The objective of this study was to use ventilated tube type as a method of generating micro-bubbles in order to purify large amount of water quality such as lakes and reservoirs. This method shows a difference in efficiency in which micro-bubbles are generated depending on the contact ratio of gas to liquid. The study also investigated the optimal gas liquid contact ratio by applying various orifice methods and investigated the optimum condition of micro-bubble generation by gas Based on this, a technology to develop a micro-bubble generator with a venturi type nozzle shape that has a high water purification effect was developed.

Forced vibration of the elastic system consisting of the hollow cylinder and surrounding elastic medium under perfect and imperfect contact

  • Akbarov, Surkay D.;Mehdiyev, Mahir A.
    • Structural Engineering and Mechanics
    • /
    • 제62권1호
    • /
    • pp.113-123
    • /
    • 2017
  • The bi-material elastic system consisting of the circular hollow cylinder and the infinite elastic medium surrounding this cylinder is considered and it is assumed that on the inner free face of the cylinder a point-located axisymmetric time harmonic force, with respect to the cylinder's axis and which is uniformly distributed in the circumferential direction, acts. The shear-spring type imperfect contact conditions on the interface between the constituents are satisfied. The mathematical formulation of the problem is made within the scope of the exact equations of linear elastodynamics. The focus is on the frequency-response of the interface normal and shear stresses and the influence of the problem parameters, such as the ratio of modulus of elasticity, the ratio of the cylinder thickness to the cylinder radius, and the shear-spring type parameter which characterizes the degree of the contact imperfectness, on these responses. Corresponding numerical results are presented and discussed. In particular, it is established that the character of the influence of the contact imperfection on the frequency response of the interface stresses depends on the values of the vibration frequency of the external forces.

조가선 전류 검측 시스템의 활용기술 연구 - 고속선 경부2단계 시험결과를 중심으로 - (Utilizing Technology in Measurement System for Catenary Current: - Focusing on Testing Results for Kyoungbu High-speed Line in Korea -)

  • 박영;정호성;이기원
    • 전기학회논문지
    • /
    • 제62권10호
    • /
    • pp.1465-1469
    • /
    • 2013
  • The resent developed high speed train called HEMU-430X (Highspeed Electric Multiple Unit - 430km/h eXperiment) recorded a 421.4 km/h in Kyoungbu high speed line in Korea. A verity of measurement systems are used to check the performance between pantograph and catenary system. An innovative measurement system is adopted to check the current of catenary wire in the track side during HEMU-430X test running. This paper presents the measurement results of catenary current in kyoungbu high-speed line and describe its utilizing technology in the experimental results of catenary current. In order to analyze field testing results, the current ratio between contact and catenary current have been analyzed by means of Carson-Pollaczek equation. And the current wave forms between catenary and contact wire are presented based on the simulation results.