• 제목/요약/키워드: contact pressures

검색결과 143건 처리시간 0.026초

CNT-Ag 복합패드가 Cu/Au 범프의 플립칩 접속저항에 미치는 영향 (Effect of CNT-Ag Composite Pad on the Contact Resistance of Flip-Chip Joints Processed with Cu/Au Bumps)

  • 최정열;오태성
    • 마이크로전자및패키징학회지
    • /
    • 제22권3호
    • /
    • pp.39-44
    • /
    • 2015
  • 이방성 전도접착제를 이용하여 Cu/Au 칩 범프를 Cu 기판 배선에 플립칩 실장한 접속부에 대해 CNT-Ag 복합패드가 접속저항에 미치는 영향을 연구하였다. CNT-Ag 복합패드가 내재된 플립칩 접속부가 CNT-Ag 복합패드가 없는 접속부에 비해 더 낮은 접속저항을 나타내었다. 각기 25 MPa, 50 MPa 및 100 MPa의 본딩압력에서 CNT-Ag 복합패드가 내재된 접속부는 $164m{\Omega}$, $141m{\Omega}$$132m{\Omega}$의 평균 접속저항을 나타내었으며, CNT-Ag 복합패드를 형성하지 않은 접속부는 $200m{\Omega}$, $150m{\Omega}$$140m{\Omega}$의 평균 접속저항을 나타내었다.

갈바어닐링온도변화가 합금화용융아연코팅의 합금상과 마찰특성에 미치는 영향 (Effects of Galvannealing Temperatures on Iron-Zn Intermetallic Compounds and Friction Characteristic of Galvannealed Coatings)

  • 이정민;김동환;이선봉;김동진;김병민
    • 대한기계학회논문집A
    • /
    • 제32권12호
    • /
    • pp.1107-1114
    • /
    • 2008
  • This paper is aimed to understand the effect of different galvannealing temperatures on the frictional properties and Fe-Zn intermetallic phases of the galvannealed (GA) coatings on steel sheets. Their galvannealing treatments were conducted at 465, 505, 515 and $540^{\circ}C$ for about 10s in the additional heating furnace of an industrial continuous hot-dip galvanizing line. The mechanical and the frictional properties of the coatings were estimated using nanoindentation, nanoscratch, micro vickers hardness tests and flat friction tests, which were performed at contact pressures of 4, 20 and 80MPa. Also, the correlation between the microstructure and the frictional properties of the GA coatings were investigated by SEM observation for the cross-section of the GA coating after and before flat friction tests. The results showed that the mechanical and the frictional properties of the coatings are strongly dependent on their phase distributions and microstructure. Especially, in low contact pressure of 4MPa the frictional properties of the coatings were dependent on the surface phases and morphology, while in high contact pressure of 80MPa it was influenced by their mechanical properties based on the dominant phase distributions.

트렁크 래치의 베이스 플레이트와 접촉스위치의 최적화 (Optimization of Base Plates and Contact Switches in Trunk Latches)

  • 김경남;노유정;김동훈
    • 한국자동차공학회논문집
    • /
    • 제22권3호
    • /
    • pp.97-104
    • /
    • 2014
  • Automobile trunk latches enable trunks to be opened and closed by a latch mechanism, which can be selectively positioned between a locked condition and an open condition. To maintain structural and electronic performance of the trunk latch, the latch needs to endure impact load that occurs in its open and close motion, and a dynamic mechanism needs to be electronically controled by a contact switch connected with a small DC motor. A base plate, which is the most important component relating to the structural safety, commonly uses a high stiffness material SAPH440-P with high manufacturing cost. In this paper, through structural analysis and optimization, production cost is significantly reduced by replacing SAPH440-P used in some region of the base plate with engineering plastic PBT GF 20%. The optimized contact switch reduces difference between distributed pressures of its two legs, which leads to improve the electronic performance of the trunk latch.

시공 중 수중터널 벌크헤드에 작용하는 충격쇄파압 - 수치해석 및 수리모형실험 - (Wave Impact Pressures Acting on the Underwater Tunnel Bulkhead under Construction - Numerical Analysis and Hydraulic Model Experiment -)

  • 김선신;안동혁;전인식
    • 한국해안·해양공학회논문집
    • /
    • 제23권2호
    • /
    • pp.139-146
    • /
    • 2011
  • 충격쇄파압은 권파성 파랑이 구조물 전면에 갑자기 충돌할 때 발생하며 접촉면에서 공기포켓의 생성여부에 따라 충격쇄파압의 작용특성이 달라진다. 수괴의 직접적인 충돌에 따른 Wagner형은 접촉면에서 단일 압력 첨두치를 보이는 반면, Bagnold형은 공기포켓의 진동에 의하여 비접촉면에서도 압력의 첨두치를 보이는 특성이 있다. 본 연구에서는 시공 중의 수중터널 벌크헤드의 배면(육측면)에 발생하는 충격쇄파압을 고찰하였다. Navier-Stokes 방정식을 직접 푸는 수치해석을 적용하여 벌크헤드 인근에 발생하는 쇄파를 모의한 결과, 벌크헤드의 배면에서 강한 Bagnold형 충격쇄파압이 발생함을 확인하였다. 본 충격쇄파압의 존재는 동일 조건에 대하여 수행한 수리모형실험에 의해서도 확인되었으며, 실험결과와 수치해석결과가 대체적으로 유사한 성향을 보임을 확인하였다.

Plantar Pressure Distribution During Level Walking, and Stair Ascent and Descent in Asymptomatic Flexible Flatfoot

  • Kim, Jeong-Ah;Lim, One-Bin;Yi, Chung-Hwi
    • 한국전문물리치료학회지
    • /
    • 제20권4호
    • /
    • pp.55-64
    • /
    • 2013
  • The first purpose was to identify the plantar pressure distributions (peak pressure, pressure integral time, and contact area) during level walking, and stair ascent and descent in asymptomatic flexible flatfoot (AFF). The second purpose was to investigate whether peak pressure data during level walking could be used to predict peak pressure during stair walking by identifying correlations between the peak pressures of level walking and stair walking. Twenty young adult subjects (8 males and 12 females, age $21.0{\pm}1.7$ years) with AFF were recruited. A distance greater than 10 mm in a navicular drop test was defined as flexible flatfoot. Each subject performed at least 10 steps during level walking, and stair ascent and descent. The plantar pressure distribution was measured in nine foot regions using a pressure measurement system. A two-way repeated analysis of variance was conducted to examine the differences in the three dependent variables with two within-subject factors (activity type and foot region). Linear regression analysis was conducted to predict peak pressure during stair walking using the peak pressure in the metatarsal regions during level walking. Significant interaction effects were observed between activity type and foot region for peak pressure (F=9.508, p<.001), pressure time integral (F=5.912, p=.003), and contact area (F=15.510, p<.001). The regression equations predicting peak pressure during stair walking accounted for variance in the range of 25.7% and 65.8%. The findings indicate that plantar pressures in AFF were influenced by both activity type and foot region. Furthermore the findings suggest that peak pressure data during level walking could be used to predict the peak pressure data during stair walking. These data collected for AFF can be useful for evaluating gait patterns and for predicting pressure data of flexible flatfoot subjects who have difficulty performing activities such as stair walking. Further studies should investigate plantar pressure distribution during various functional activities in symptomatic flexible flatfoot, and consider other predictors for regression analysis.

유선형 후방 밸런스 신발과 일반 신발의 족저압 비교 (The Plantar Pressure Comparison between the Curved Rear Balance Shoes and Normal Shoes)

  • 김연정;채원식
    • 한국운동역학회지
    • /
    • 제17권3호
    • /
    • pp.173-180
    • /
    • 2007
  • The purpose of study was to compare plantar pressure during walking wearing the curved rear balance and normal shoes. Twelve university students(height: $177.2{\pm}4.6cm$, weight: $68.4{\pm}5.8kg$, age: $26.2{\pm}1.6yrs.$) who have no known musculoskeletal disorders were recruited as the subjects. Plantar foot pressures were evaluated using the Tekscan's pressure measurement systems while subjects walked upright position wearing the curved rear balance and normal shoes in random order at a speed of 1.3 m/s. The contacting dimension, the mean plantar pressure, and the peak plantar pressure were determined for each trial. For each dependent variable, paired t-test was performed to test if significant difference existed between shoe conditions (p<.05). As a result, the curved rear balanced shoes showed as large as 38 up to 50 % of area at the rear side of feet than the normal shoes when measuring the contact area with upright position. In the distribution of average pressure, the curved rear balanced shoes displayed fairly low pressure compared to other normal shoes in general except for one area, which is M2, and especially, the measured pressures at the both rear (M1) and middle (M5) side of feet were low and statically significant. The contact area of the curved rear balanced shoes when walking was significantly larger at the rear (M1) and fore (M6, M7) side of feet. When considering pressure distribution at walking, low pressure was detected at the rear side of feet with the curved rear balanced shoes and at the fore side of feet for other normal shoes. The results showed that the contacting dimension of the curved rear balance shoes that acts between shoes and feet was higher than the corresponding value for the normal shoes in general; therefore it would reduce the pressure to the feet by allowing the each sole of the foot on the ground evenly.

반치환 무릎 인공관절에서의 재료조합에 따른 접촉압력 분석 (Analysis of Contact Pressure for Material Combination in Unicompartmental Knee Implant)

  • 노태헌;전흥재
    • 한국전산구조공학회논문집
    • /
    • 제31권1호
    • /
    • pp.23-29
    • /
    • 2018
  • 무릎 임플란트에서 접촉압력이 마모에 큰 영향을 미친다. 본 연구에서는 본 연구기관에서 개발한 무릎 임플란트 모델을 이용하여 유한요소해석을 하였다. 연구와 산업에서 실제로 사용하는 조합을 이용하여 총 10가지의 무릎 임플란트의 재료조합에 대한 접촉압력을 분석하였다. 무릎이 30도, 45도 60도 기울어져있을 때의 하중을 가하여 접촉압력을 구하였다. 접촉압력을 계산한 결과 티타늄합금-UHMWPE 조합에서 가장 작은 접촉압력이 나왔다. UHMWPE의 경우 대퇴골부에 어떠한 재료를 사용하여도 접촉압력이 크게 변하지 않았다. 접촉압력이 가장 큰 조합과 작은 조합을 비교하였을 때 0.77% 차이를 보였다. 반면에 Carbon/PEEK 복합재료의 경우 접촉압력이 가장 큰 경우와 작은 경우를 비교하였을 때 5.3% 차이를 보였다. 이를 통해 Carbon/PEEK 복합재료를 베어링부로 사용할 경우 대퇴골부의 재료가 마모에 영향을 미침을 알 수 있다. 본 연구는 무릎 임플란트 마모예측과 마모를 최소화 연구에 도움이 될 것이라 생각한다.

Numerical Analysis for High-rise Building Foundation and Further Investigations on Piled Raft Design

  • Won, Jinoh;Lee, Jin Hyung;Cho, Chunwhan
    • 국제초고층학회논문집
    • /
    • 제4권4호
    • /
    • pp.271-281
    • /
    • 2015
  • This paper introduces detailed three-dimensional numerical analyses on a bored pile foundation for a high-rise building. A static load test was performed on a test pile and a numerical model of a single pile, which was calibrated by comparing it with the test result. The detailed numerical analysis was then conducted on the entire high-rise building foundation. Further study focused on soil pressures under the base slab of a piled raft foundation. Total seven cases with different pile numbers and raft-soil contact conditions were investigated. The design criteria of a foundation, especially settlement requirement were satisfied even for the cases with fewer piles under considerable soil pressure beneath the base slab. The bending moment for the structural design of the base slab was reduced by incorporating soil pressures beneath the base slab along with bored piles. Through the comparative studies, it was found that a more efficient design can be achieved by considering the soil pressure beneath the slab.

대형 2행정 디젤기관에 있어서 전자제어 퀼 부착 모터구동 실린더 주유기의 송출유량 특성에 관한 연구 (A Study on Feed Rate Characteristics of Motor-driven Cylinder Lubricator with Electronic Control Quill in a Large Two-stroke Diesel Engine)

  • 배명환;정화;정연학;김인덕;강창호
    • 한국자동차공학회논문집
    • /
    • 제15권6호
    • /
    • pp.1-8
    • /
    • 2007
  • Minimizing the cylinder wear and the consumption rate of cylinder oil in a large two-stroke marine diesel engine is of great economic importance. In Korea, authors first developed a motor-driven cylinder lubricator for a Wartsila Switzerland large two-stroke diesel engine. The characteristic of the developed product is that can control automatically the oil feed rate with a load fluctuation by the motor drive and the offset cam. For manufacturing the reliable and useful products, however, it is necessary to investigate further characteristics and to improve performances as a cylinder lubricator. In this study, the effects of pump motor speed, plunger stroke and cylinder back pressure on oil feed rate, maximum discharge and delivery pressures are experimentally investigated by using the electronically controlled quill injection system and distributer in the developed cylinder lubricator. It is found that the oil feed rates of electronic control and mechanical type quills with the in-cylinder back pressure are differently characterized by the role of accumulator, the viscous resistance of contact area, etc. It can be also shown that the maximum discharge pressure of the electronic control quill is lower than the mechanical type one but the maximum discharge pressure difference of two types decreased as plunger stroke is small, and the maximum delivery pressures of two types increased as plunger stroke, motor speed and back pressure are elevated but the maximum delivery pressure of mechanical type is higher than the one of electronic control type.

이동작동기식 완전 이식형 인공 심장의 심실간 공간 압력 파형 해석에 관한 실험적 연구 (An Experimental Study on the Analysis of the Interventricular Pressure Waveform in the Moving-Actuator type Total Artificial Heart)

  • 조영호;최원우
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권1호
    • /
    • pp.25-36
    • /
    • 1997
  • To regulate cardiac output of the Total Artificial Heart(TAH) physiologically, the hemodynamic information must be toed back to the controller. So far, our group has developed an automatic cardiac output control algorithm using the motor current waveform, It is, however difficult to detect the preload level such as a filling status of ventricular inflow and the variation of atrial pressures within normal physiologic range(0-15 mmHg) by analyzing the motor current which simultaneously reflects the afterload effect. On the other hin4 the interventricular volume pressure(IVP) which is not influenced by arterload but by preload is a good information source for the estimation of preload states. In order to find the relationship between preload and IVP waveform, we set up the artificial heart system on the Donovan type mock circulatory system and measured the IVP waveform, right and left atrial pressures, inflow and outflow waveforms and the signals represented the information of moving actuator's position. We shows the feasibility of estimating the hemodynamic changes of inflow by using IVP waveform. fife found that the negative peak value of IVP waveform is linearly related to atrial pressures. And we also found that we could use the time to reach the negative peak in IVP waveform, the time to open outflow valve, the area enclosed IVP waveform as unfu parameters to estimate blood filling volume of diastole ventricle. The suggested method has advantages of avoiding thrombogenesis, bacterial niche formation and increasing longterm reliability of sensor by avoiding direct contact to blood.

  • PDF