• Title/Summary/Keyword: contact lenses

Search Result 217, Processing Time 0.021 seconds

Physical Characterization and Contact Lens Application of Polymer Produced with Propylene Glycol Additive (프로필렌 글리콜을 첨가제로 사용한 고분자재료의 물성 및 콘택트렌즈 응용)

  • Kim, Tae-Hun;Sung, A-Young
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.1
    • /
    • pp.105-109
    • /
    • 2010
  • HEMA (2-hydroxyethyl methacrylate), EGDMA (ethylene glycol dimethacrylate) and propylene glycol was copolymerized in the presence of AIBN (azobisisobutyronitrile) initiator in a mould. The physical properties of the contact lens were measured. The water content of 37.06~38.71%, refractive index of 1.492~1.432, visible transmittance of 89.4~91.5%, tensile strength of 0.1416~0.2302 kgf, and contact angle of $38.60{\sim}53.53^{\circ}$ were obtained. Therefore, the contact lens material produced using propylene glycol as an additive satisfied the basic physical properties required for contact lenses application. It is interesting to note that an increase in wettability and tensile strength while having no significant changes in water content.

Optophysical Properties of Hydrogel Ophthalmic Lenses Containing Gallate Group (Gallate group이 포함된 친수성 안의료용 렌즈의 광물리적 특성)

  • Park, Se-Young;Sung, A-Young
    • Journal of the Korean Chemical Society
    • /
    • v.56 no.6
    • /
    • pp.725-730
    • /
    • 2012
  • HEMA (2-hydroxyethyl methacrylate), EGDMA (ethylene glycol dimethacrylate; cross-linker), MMA (methyl methacrylate) and AA (acrylic acid) were copolymerized with ethyl gallate and propyl gallate as additives in the presence of AIBN (2,2'-azobisisobutyronitrile; initiator). The measurement of physical properties of the produced copolymers exhibited that refractive index, water content, visible transmittance, tensile strength, and contact angle were in the range of 1.433-1.435, 38.71-38.99%, 85.4-88.8%, 0.2468-0.2740 kgf and $49.77-36.29^{\circ}$, respectively. The transmittances of the copolymers were measured to be in the range of 49.0-7.4% and 71.0-43.4% for UV-B and UV-A, respectively, indicating that the copolymers have UV-blocking effect. The produced copolymers containing ethyl gallate and propyl gallate satisfied the basic physical properties required for the fabrication of hydrogel contact lenses. The copolymers showed an increase of wettability and UV-blocking effects while having no significant change in water content compared to the gallate-free copolymers.

Physical Properties of Styrene Copolymer and Contact Lens Application (스타이렌 공중합체의 물리적 특성 및 콘택트 렌즈로의 응용)

  • Kim, Tae-Hun;Ye, Ki-Hun;Sung, A-Young
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.6
    • /
    • pp.755-760
    • /
    • 2009
  • Styrene is broadly used as a polymer and a copolymer and is useful in manufacturing contact lenses due to its high refractive index. This study used styrene with the cross-linker EGDMA (ethylene glycol dimethacrylate), HEMA (2-hydroxyethyl methacrylate) and the initiator AIBN (azobisisobutyronitrile) for copolymerization. Measurement of the physical characteristics of the copolymerized material showed that the refractive index is 1.4412 - 1.4628, water content 20 - 35%, visible transmittance 82.6 - 87% and the tensile strength 0.143 - 0.344 Kgf. Also, measurements showed that the refractive index and tensile strength increased while the water content decreased as the ratio of styrene increased. Based on the results of this study, the produced copolymer can be estimated to be suitable for use as a material for high performance functional contact lenses.

The Contamination Level of Lens Cases by Various Wearing and Storage Periods of Soft Contact Lens and the Actual Condition of Lens Cases Care (소프트 콘택트렌즈 착용 기간과 보관 기간에 따른 보관 용기의 오염도 및 보관 용기 관리 실태)

  • Kim, So Ra;Shin, Sang Mok;Park, Jong Ae;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.135-145
    • /
    • 2011
  • Purpose: This study was conducted to investigate the actual condition of caring soft contact lens cases and the change in contamination level of lens cases by wearing and storage period of soft contact lens. Methods: The actual condition of caring soft lens cases was surveyed with sixty-three of contact lens wearers. Soft contact lenses were worn for 1, 3, 7 and 14 days, and the lenses were separately stored in 12 lens cases for 1, 3 and 7 days. The contamination level of lens cases was determined by counting the numbers of microorganisms, gram negative bacteria and fungi. Results: Only 14% of survey answerers cleaned their lens cases with a brush, rinsed and dried them upside down before next usage of lens case when those lenses were kept for a long time. Furthermore, 54% of total answerers just kept soft contact lens in the case without changing the multipurpose solution. Microorganisms, gram negative bacteria and fungi were detected in lens cases even when soft contact lens were kept for 1 day in the lens case after wearing for 1 day and cleaning it with multipurpose solution. The numbers of microorganisms, gram negative bacteria and fungi in lens cases increased with storage periods of soft contact lens, and also contamination level of lens cases was increased in accordance with wearing period of lens. In the lens cases without changing multipurpose solution, the numbers of microorganisms, gram negative bacteria and fungi increased with storage period of lens with statistical significance. Conclusions: This study showed that lens wearers' concerns on caring contact lens case were not satisfactory. As the result, the contamination of lens cases was related to increase of lens wearing and storage periods suggesting that the proper instruction and education for lens wearers are required.

Opto-Physical Properties of Ophthalmic Lens Polymer Containing σ, m, p-Substituted Difluoroaniline as Additives (σ, m, p-위치로 치환된 Difluoroaniline을 첨가제로 사용한 안의료용 렌즈 고분자의 물리·광학적 특성)

  • No, Jung-Won;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.69-77
    • /
    • 2014
  • Purpose: The functional ophthalmic lenses containing fluorine-substituted aniline group (2,4-difluoroaniline, 2,6-difluoroaniline, 3,4-difluoroaniline) were manufactured and the physical and optical characteristics of copolymerized ophthalmic lens were investigated. Methods: HEMA (2-hydroxyethylmethacrylate), NVP (N-vinyl pyrrolidone), MA (methacrylic acid), the cross-linker EGDMA (ethylene glycol dimethacrylate) and the initiator AIBN (azobisisobutyronitrile) were used as a basic combination and fluorine-substituted aniline group (2,4-difluoroaniline, 2,6-difluoroaniline, 3,4-difluoroaniline) were used as additives for preparing the hydrogel soft contact lenses. The hydrogel ophthalmic lens was manufactured by cast mould method and the ophthalmic lenses were stored in a 0.9% NaCl normal saline for 24 hrs. Results: The optical transmittance of the sample with addition 2,4-difluoroaniline showed that the UV-B(9.8~51.4%), UV-A(58.8~79.2%) and visible transmittance(87.0~90.4%). In the case of 2,6-difluoroaniline were measured the UV-B(80.2~83.2%), UV-A(85.8~86.4%), and visible transmittance(90.8~91.4%). Also, the optical transmittance of ophthalmic lens containing 3,4-difluoroaniline were measured the UV-B transmittance of 3.8~30.4%, UV-A transmittance of 47.8%~74.4% and the visible transmittance of 86.2~91.0% respectively. Conclusions: Based on the results of this study, 2,4-difluoroaniline and 3,4-difluoroaniline can be used effectively as additive for UV-blocking ophthalmic contact lenses.

Use of Piggyback Contact Lens System to GP Lens Wearers (GP렌즈 착용자에게 피기백 콘택트렌즈 시스템의 적용)

  • Kim, Yong Gil;Kim, Soo Hyun;Kim, Jai Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.47-53
    • /
    • 2010
  • Purpose: This study was performed to achieve an acceptable piggyback fit utilizing each subject's own GP lenses, in subjects with regular low myopic astigmatism. Methods: A randomized, prospective study of 15 subjects with the diagnosis of low myopic astigmatism was conducted. Nine subjects were female and 6 were male, and mean age was: 23.73${\pm}$1.68 years. Subjects were evaluated before participate on this study and then also evaluated with period of at two hours and two weeks after obtaining their lenses. All subjects were submitted to the following tests: measurement of comfort level by means of the analogical visual scale, best corrected visual acuity and over-refraction at distance. contrast sensitivity and stereo acuity. After evaluating the fit of plano soft lens, we applied each subject's own GP lens on top. Results: Vision, visual performance and satisfaction of piggyback contact lens system were stable, if not improved, for the 15 subjects when the data was compared to the patients' wear of rigid gas permeable contact lenses. Fit with a piggyback system had the same or improved comfort, visual acuity and contrast sensitivity compared to previous GP lens wear alone. The visual acuity, contrast sensitivity and stereo acuity did not show differences in relation to the studied lens type. Conclusions: These results suggest that it is possible to achieve a successful piggyback lens fitting utilizing a patient's own GP lens. The piggyback lens system satisfied the visual performance and visual requirements of this subject with GP lens alone for the correction of low myopic astigmatism.

Vibration of Contact Lenses (콘택트 렌즈의 진동에 관한 연구)

  • Kim, Dae Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.13-29
    • /
    • 2001
  • A mathematical model was proposed to analyze the vibration of diaphragm, such as the contact lenses fitted on the eyes, being subjected to the external sinusoidal pressure. The model incorporates the differential equations and their numerical solution program, based on the wave equations. Turbo-C and graphic software, formulated to describe the dependence of the various parameters involved in the vibration. The model predicts the radial distribution of amplitude, frequency dependence of both average displacement amplitude and the power of diaphragm whose edge is being either simply supported or rigidly clamped in vibration. The effect of variables such as thickness, radius, damping coefficients on the vibration characteristics was illustrated by the computer simulation of the derived program. As the frequency of driving pressure increases above the certain value determined by the boundary conditions and parameters the wave shape or pattern changes from simple arc to belly or loops having double antinode. It seems that the effect of outer antinode progressively increases as the frequency increases. If this kind of phenomena occurs to the contact lens on the cornea in vivo, it may cause an abnormal correction power in the lenses or pull off the eye due the increased rise of outer part of the lens.

  • PDF

Effect of Visual Difference on Balance and Walking Capacity in Life Care of College Students (대학생의 라이프케어에서 시력 차이가 균형과 보행능력에 미치는 영향)

  • Yoon, Young-Jeoi
    • Journal of Korea Entertainment Industry Association
    • /
    • v.15 no.1
    • /
    • pp.191-197
    • /
    • 2021
  • This study studied the effect of visual difference on balance and walking ability in college students' life care. The study was conducted on 45 students attending H University in G City, divided into control groups (n=22, not wearing glasses and contact lenses) and experimental groups (n=23, wearing glasses and contact lenses). In not wearing glasses and contact lenses, the subjects measured visual acuity with logMAR charts, evaluated their balance ability with BIOrescue, and evaluated walking ability with G-Walk. The results of this study showed that the experimental group had statistically significantly lower vision than the control group in the visual acuity measurement(p<.01). Static balance ability was statistically significant increase in center of mass movement of the right foot in the experimental group compared to the control group(p<.05). Dynamic balance ability was statistically significantly reduce in limit of stability for groups of experiments compared to control group(p<.05). The walking ability was statistically significantly shorter on step length and stride length, swing of the experimental group compared to the control group in the right foot(p<.05). The findings showed that the visual difference in university students reduces balance and walking ability. Therefore, university students with poor visual acuity are recommended to correct of visual acuity to prevent collision and falls in their daily lives.

The Change in the Parameters of Silicone Hydrogel Lens and Objective/Subjective Symptoms induced by Repetitive Dryness of Lens (실리콘 하이드로겔 렌즈의 반복적 건조로 인한 렌즈형태 및 자·타각적 증상의 변화)

  • Kim, So Ra;Kang, Byeong Ho;Jung, In Pil;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.381-388
    • /
    • 2012
  • Purpose: In this study, the changes in the shape of silicone hydrogel lenses, dryness of lens and objective/ subjective symptoms that could be induced by repeating dryness of lens and objective/subjective symptoms were investigated. Methods: After drying and rehydrating of silicone hydrogel lenses with different lens material and thickness for 4 times, their overall diameters and base curves were compared. Subjective symptoms, non-invasive tear break-up time (NIBUTs) and blinking rate were evaluated after wearing dehydrated silicone hydrogel lens. Results: Overall diameter and base curve increased in all tested silicone hydrogel lenses by repeating dryness and rehydration. The degree of change in over all diameter and base curve were variable on the material. There were irregular change of lens parameters in thicker lens. When the subjects wore silicone hydrogel lenses after drying and rehydrating, their NIBUTs were decreased and blink rates were increased regardless of lens material or thickness. In addition, repetitive drying of silicone hydrogel lenses affected the lens fitting. Therefore, subjective symptoms such as itching, pain, irritation, foreign body sensation, dryness tended to be increased. Conclusions: The results obtained from the study may suggest to develop durable silicone hydrogel contact lenses against dry environment since the changes in parameters of silicone hydrogel lens and the subjective discomfort were observed after repetitive drying and rehydration.

A Comparison of the Contact Areas between Cornea and RGP Lenses by Fitting Status (피팅 상태에 따른 RGP 렌즈와 각막과의 간극 비교)

  • Park, Eun Hye;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.255-264
    • /
    • 2012
  • Purpose: In this study, the effect of lens fitting status on the contact area between spherical/aspherical RGP lens and the cornea having different astigmatic degree and corneal type was investigated for guiding the proper selection of RGP lens. Methods: Spherical and aspherical RGP lenses were applied on ninety eyes $(25.12{\pm}3.52years)$ having with-the-rule astigmatism by different fitting status. Then, their central, mid-peripheral and peripheral areas of fluorescein pattern were calculated and compared for the quantitative evaluation of the contact area between spherical/aspherical RGP lens. Results: The central and peripheral areas with the alignment fitting was significant different based on lens design. However, the central area didn't show any significant difference by lens design and corneal type when fitted in steep or flat. When analyzed by the corneal shape, both lenses with alignment and flat fitting had significant difference in central and peripheral areas. However, the central, mid-peripheral and peripheral areas with steep fitting didn't show the difference by corneal types. When analyzed by the astigmatic degree, the central and peripheral areas with alignment fitting changed proportionally to the increase of corneal astigmatism regardless of corneal shape. With steep and flat fitting, however, the central, mid-peripheral and/or peripheral areas in round- and symmetric bowtie-typed corneas showed the conflicting result when compared to those of alignment fitting when analyzed by the astigmatic degree. Conclusions: In this study, it was confirmed that the contact areas of cornea and RGP lens fitted steep and flat status were largely affected by the corneal type and corneal astigmatism rather than RGP lens fitted in alignment status. Also, this result commonly occurred in both spherical and aspherical RGP lenses.