• Title/Summary/Keyword: contact lenses

Search Result 217, Processing Time 0.024 seconds

Change of Spherical Aberration with Aspheric Soft Contact Lens Wear (비구면 소프트콘택트렌즈 착용에 의한 눈의 구면수차 변화)

  • Kim, Jeong Mee;Mun, Mi-Young;Kim, Young Chul;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.365-372
    • /
    • 2012
  • Purpose: To investigate ocular higher order aberrations (HOA) and spherical aberration changes caused by an aspheric soft contact lens designed to reduce spherical aberration (SA) of the eye. Methods: Fifty subjects who have successfully experienced soft contact lenses were refitted with aspheric design (Soflens Daily Disposable: SDD, Bausch+Lomb) soft contact lens. Ocular higher order aberrations (HOA) and stand alone SA were measured and analyzed for a 4-mm pupil size using Wave-Scan Wavefront$^{TM}$ aberrometer (VISX, Santa Clara, CA, USA). High and low contrast log MAR visual acuity and contrast sensitivity function (CSF) were also measured under photopic and mesopic conditions (OPTEC 6500 Vision Tester$^{(R)}$). All measurements were conducted monocularly with an undilated pupil. Results: The RMS mean values for total HOA with SDD contact lenses were significantly lower than those at with unaided eyes (p<0.001) and a reduction for SA in the SDD was close to the baseline SA (zero ${\mu}m$) (p<0.001). For the SDD lens, there was a statistically significant correlation between the changes in the total HOA and the contact lens power (r=0.237, p=0.018) as well as between the changes in SA and the lens power (r=0.324, p=0.001). High contrast visual acuity (HCVA) and low contrast visual acuity (LCVA) with SDD lenses were $-0.063{\pm}0.062$ and $0.119{\pm}0.060$, respectively under photopic and $-0.003{\pm}0.063$ and $0.198{\pm}0.067$, respectively under mesopic condition. Contrast Sensitivity Function (CSF) with SDD lenses under both photopic and mesopic conditions was $3.095{\pm}0.068$ and $3.087{\pm}0.074$, respectively. Conclusions: The SDD contact lens designed to control SA reduced the total ocular HOA and SA of the eye, resulting in compensating for positive SA of the eyes. Thus, the optical benefits of the lens with SA control would be adopted for improving the quality of vision.

Analysis of Vertex Refractive Power Accuracy of Soft Contact Lens with Holder Type (홀더종류에 따른 소프트 콘택트렌즈의 정점굴절력 측정의 정확도 분석)

  • Lee, Min-Jae;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.105-115
    • /
    • 2015
  • Purpose: The accuracy for measuring the refractive power of hydrogel contact lenses by spectacle lens holder and contact lens holder was evaluated. The accuracy for each sample was also analyzed with water content and diopter categories. Methods: The hydrogel contact lenses used for measurement were classified into three categories in water content (38%, 43%, 58%). Also, three diopter categories of refractive power were used such as -3.000 D, -7.000 D, -10.000 D. And also, the reliability of measurement results were evaluated by measuring refractive power with spectacle lens holder and contact lens holder using an Manual lensmeter. Results: In case of spectacle lens holder method, the average value of refractive power was -3.3273D for -3.0000 D, -7.1306 D for -7.0000 D and -10.2944 D for -10.0000 D, respectively. In case of contact lens holder method, the average value of refractive power was -3.1060 D for -3.0000 D, -7.0028 D for -7.0000 D and -10.2611 D for -10.0000 D, respectively. In measurement of all diopters, the accuracy of contact lens holder method was better than spectacle lens holder method. Conclusions: From these results, it is judged that the refractive power of soft contact lens by manual lensmeter with contact lens holder have a higher accuracy than spectacle lens holder.

Subjective Symptoms according to Fitting Test in Soft Contact Lens Wearers (소프트콘택트렌즈 착용자의 피팅 상태 확인 유무에 따른 자각적 증상)

  • Kim, Jung-Hee;An, Youngju
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.431-442
    • /
    • 2018
  • Purpose : The purpose of this study was to investigate subjective symptoms according to the wearing, purchase and fitting status of soft contact lens wearers, and consumer perception of base curve. Methods : A survey was conducted for those who visited optical shops and lens shops in Seoul from June to August 2018. A total of 98 answer sheets they submitted were used for the analysis. The chi-square test and Fisher's exact test were used to compare subjective symptoms (dryness, glare, uncomfortable fitting, and decreased vision) according to whether fitting condition is screened (case history and push-up test, ect relevant to wearing sensation), and the odds ratio (OR) was obtained by the logistic regression analysis. Results : When the contact lenses were purchased, the rate of which the visual acuity test was performed was 86.6% at optical shop and 64.7% at lens shop. When purchasing contact lens and the contact lens was not tested for fitting, they more experienced dryness (OR 4.41, 95% CI 1.25-15.62) and uncomfortable fitting (OR 2.68, 95% CI 1.08-6.64) than testing for fitting. In addition, it was investigated that 87.8% of contact lens wearers did not know about the term base curve, 92.9% did not listen to an explanation related to the base curve when purchasing contact lenses, and 96.9% did not experience with base curve test. Conclusion : It would be thought that satisfaction of the contact lens fitting of existing consumers should be improved by changing a proper base curve by confirming the fitting condition when prescribing soft contact lens.

Effect of Hydrogel lens and Silicone-Hydrogel lens on Corneal thickness (하이드로겔 렌즈와 실리콘-하이드로겔 렌즈가 각막 두께에 미치는 영향)

  • Seo, Jung-Ick
    • Journal of Korean Clinical Health Science
    • /
    • v.5 no.4
    • /
    • pp.1021-1025
    • /
    • 2017
  • Purpose: Changes in corneal thickness after wearing hydrogel lens and silicone-hydrogel lens with different oxygen transmission rates wew syudied. Methods: Experiments were performed on 11 subjects(22 eyes). corneal thickness was measured after wearing contact lenses for 8 hours. Corneal thickness was measured using ORB Scan II(ver. 3.14) Results: In the results of the corneal thickness measurement by direction, in the case of the hydrogel-tor lens, the center thickness was $33.63{\mu}m$, the nasal was $34.29{\mu}m$, the temporal was $27.17{\mu}m$, the inferior was $27.17{\mu}m$, the superior was $18.90{\mu}m$, and change rates were 6.28%, 5.71%, 5.40%, 4.75% and 3.09%, respectively. In the results of the corneal thickness measurement by diameter, in the case of the hydrogel-tor lens, the center was $33.63{\mu}m$, the mid-peripheral was $28.19{\mu}m$, the peripheral was $24.18{\mu}m$, and change rates were 6.28%, 4.76%, and 3.79%, respectively. Conclusions: The hydrogel lenses with relatively low oxygen transmission rates resulted in a significant increase in thickness over the entire cornea compared to silicon-hydrogel lenses with high oxygen transmission rates.

The Effect of Artificial Tear Components on Tear Film Stability of Dry Eyes in the Early Stage of Soft Contact Lenses Wear (소프트콘택트렌즈를 착용한 건성안의 착용초기 눈물막 안정성에 인공눈물 성분 조성이 미치는 영향)

  • Kim, So Ra;Lim, Jung A;Jung, Ji Hye;Byun, Hyun Young;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.191-201
    • /
    • 2016
  • Purpose: In the present study, the effect of artificial tears with different ingredients on tear film stability and subjective symptoms of dry eyes in the early stage of soft contact lenses wear was investigated. Methods: The three kinds of artificial tears and saline solution were respectively applied onto 50 dry eyes which wore soft contact lenses made of etafilcon A. Then, non-invasive tear film break-up time (NIBUT) was measured at every five minutes for 30 minutes right after the instillation of artificial tears, and the changes in blink rate and subjective symptoms were estimated after 30 minutes from the instillations. Results: All three kinds of artificial tears increased NIBUT larger than saline. The effect of increasing NIBUT immediately after the instillation of artificial tears was the largest when the artificial tear containing viscosity enhancer was used. The duration time of the effect was the longest when the artificial tear having both surfactant and viscosity enhancer was applied. The blink rate was not significantly changed when both artificial tears and saline solution were instilled. Subjective symptoms were significantly improved by the instillation of both artificial tears and saline solution and dryness, irritation, tiredness, stiffness, dazzling were improved by the use of most solutions. However, the subjective symptoms were rebounded to the level before the instillation of artificial tears after 30 minute-instillation. Conclusions: It was revealed that both artificial tears and saline solution could improve the subjective symptoms of dry eye in the early stage of soft contac lenses however, the effect of these solutions on the tear film stability was different according to the components. From the results, it is suggested that the proper selection of artificial tears is necessary for the improvement of dry eye symptoms at the early stage of soft contact lenses wear in dry eye.

Impact of Refractive Surgery on Quality of Life in Myopia Patients (시력교정수술이 근시환자의 삶의 질에 미치는 영향)

  • Kang, Sue-Ah;Kim, Jung-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.4
    • /
    • pp.337-344
    • /
    • 2006
  • Purpose: To evaluate the vision-specific Quality of Life according to modes of refractive error correction in myopia. Method: This study included subjects from two different universities in Korea during March 2005 to June 2005. The following subjects (470) were university students, university faculty members, and their immediate families; all of whom were over the age of 19 and all who had refractive error of some sort. The four focus groups consisted of 171 spectacle wearers, 154 contact lens wearers, 123 refractive surgery patients, and 22 post-refractive surgery patients who returned to wearing glasses. The study of Vision-Specific Quality of Life used QIRC - The Quality of Life Impact of refractive Correction Questionnaire, which was translated by our group from English into Korean. Using analysis of co-variance (ANCOVA) and adjusting for age, sex, job, economic status, and education level, we examined and compared the QOL mean scores of the three groups (glass & contact lenses wears, refractive surgery patients, and post-refractive surgery patients who returned to wearing glasses). Results: After adjusting for major compounding variance, the research results showed the highest QOL mean score of 43.2 for the group who had received refractive surgery, 37.1 for the glasses & contact lenses group, and 33.4 for patients who had returned to wearing glasses after refractive surgery. There were significant differences between the three groups (p=0.001). Conclusion: Refractive surgery has shown a significant contribution to improve the QOL in myopia patients. However, upon our investigation, patients who underwent refractive surgery and returned to wearing glasses had a lower QOL compared to non-refractive surgery patients who wore glasses/contact lenses. Upon concluding our studies that shows that refractive surgery does not always conclusively bring higher QOL, we would like patients to carefully consider their options before undergoing refractive surgery in the future.

  • PDF

Comparison of Corneal Edema Induced by Material of Contact Lens (콘택트렌즈의 재질별 각막부종의 비교)

  • Kim, Ki-Sung;Kim, Sun-Kyung;Kim, Tae-Hun;Kim, Hyo-Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.151-156
    • /
    • 2015
  • Purpose: This study has been compared the degree of corneal edema arising from the material of the lens after wearing the recommended wearing time for the contact lens. Methods: For the study, 43 adults of 77 eyes who did not use drugs and have not any disease participated. Three types of lenses including narafilcon A, HEMA, and silicone hydrogel material regular replaceable lenses were used. Central corneal thickness was measured before and after 8 hours from wearing lenses using Pentacam. The degree of corneal edema was determined by the difference before and after wearing. Results: The average corneal edema of narafilcon A, HEMA material lens, and silicone hydrogel material regular replaceable lens were $2.36{\pm}6.15{\mu}m(Mean{\pm}SD)$, $23.61{\pm}10.71{\mu}m$, $18.25{\pm}8.64{\mu}m$, respectively. The central corneal thickness after wearing narafilcon A was not statistically significant with the central corneal thickness before wearing the lens. Central corneal thickness before and after wearing HEMA material lens and silicone hydrogel material regular replaceable lens were statistically significant. Conclusions: The amount of corneal edema induced by silicone hydrogel material regular replaceable lens was no statistically significant difference to the amount of corneal edema induced by HEMA material lens, but there was significant difference to narafilcon A. Therefore, it is judged to be careful not to exceed the recommended wearing time depending on the composition of the contact lens material.

Microbial contamination in contact lens care systems (Contact lens care system의 미생물 오염)

  • Kim, Sang-Moon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.1 no.1
    • /
    • pp.57-63
    • /
    • 1996
  • The microbial contamination in contact lens care systems and conjunctivas of 40 asymptomatic cosmetic soft contact lens wearers was investigated. Patient ages ranged from 19 to 27(mean:22), most of them have used hydrogel contact lenses for less than 1 year, and the ages of lens cases were 1 weeks ~ 3 months (43 %) or 4~6 months (52%). Twenty-seven patients (67%) chemically disinfected their lenses and 8(20 %) used hydrogen peroxide, and 5 used heat to disinfect. Fourteen patients used commercial non-preserved saline, and 26(65%) were using commercial preserved saline. Sixty-two percent of the patients had bacterial contamination of lens case, and 17% had conjunctival contamination. The bacterial contamination rate was highest in lens cases, followed by unpreserved salines, disinfecting chemicals(non-hydrogen peroxide), and conjunctivas. The fungal contamination rate of cases and conjunctivas was 67% and 15%, respectively, and lens case, unpreserved saline, and conjunctiva seemed more susceptible to contamination. The use of hydrogen peroxide for disinfection rather than chemical disinfection was associated remarkabley with decreased contamination of solution itself, and there was no significant difference in contamination rates between hydrogen peroxide care system and other disinfecting systems. Five of lens cases(13%) and 2 conjunctivas(5%) were contaminated with Pseudomonas aeruginosa, and Candida albicans were isolated from 11cases (27%) and 5 conjunctivas (12%). Of the organisms that were contaminated lens cases and conjunctivas, Pseudomonas aeruginosa, Escherichia coli, Candida albicans, and Aspergillus fumigatus were isolated from lens cases, whereas Pseudomonas aeruginosa, Candida albicans, and Aspergillus fumigatus were recorvered from conjunctivas. Fortunately all of the these tested samples showed 0% of Acanthamoeba in this investigation.

  • PDF

The Current State of Lens Care in Contact Lens Wearer (콘택트렌즈 착용에 따른 사용자 실태조사)

  • Ryu, Geun Chang;Kim, In Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.1
    • /
    • pp.15-20
    • /
    • 2002
  • The Hydroxyethyl methacrylate(HEMA) was developped in 1960's and later the use of contact lenses increased. At present more and more people use RGP contact lenses. Due to the wide range of optical corrections available and due to their high oxygen transmission Japanese and Korean people like them. Nevertheless one of nine CL users(beginners) stopped wearing the CL within the first year. We conducted a survey to evaluate the level of patient compliance in lens care and maintenance and to assess practitioner knowledge of contact lens information. Generally 6% of contact lens wearers drop out per year. The aim of this research was to find out what opticians can do to reduce the drop-out rate by getting information on handling, on general data of the patient and on optical prescription. Lens wearer were asked to complete a 10 question survey that focused on lens care-wear modality, lens replacement, storage, symptoms and case disinfection. There were total 180 participants in the study. Most of contact lens wearers have an inadequate understanding of contact lens care system. Therefore, it is important that contact lens specialists place more emphasis on practitioner education about general contact lens fields and reinforce patient education during the dispensing visit.

  • PDF

Design of mobile health care application using smart contact lenses (스마트 콘택트 렌즈를 이용한 모바일 건강 관리 어플리케이션 설계)

  • Lee, SeungHwan;Song, EunSu;Ryu, WooSeok
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2021.07a
    • /
    • pp.337-338
    • /
    • 2021
  • 본 논문에서는 스마트 콘택트 렌즈를 이용한 건강 관리 어플리케이션을 제안한다. 기존에 연구되고 있던 스마트 콘택트 렌즈에 있는 센서들을 통해서 렌즈 사용자의 생체 데이터를 수집하고 수집한 데이터를 수치화 하여 당뇨병, 녹내장, 간략한 스트레스 지수 까지 시각화 하여 보다 편하게 자가 진단하고 예방하는데 그 목적이 있다. 렌즈의 구성으로는 생체 데이터를 수집하는 센서는 포도당 농도 측정 센서, 안압 측정 센서, 코르티솔 호르몬 측정 센서가 있고, 어플과 연동하기 위한 통신 센서가 포함 된다. 이후 수집된 데이터를 수치화 한 후 어플 화면에 시각화하여 사용자가 각 항목을 확인하는데 있어서 편리 할 수 있다. 많은 사용자들의 데이터가 모이면 이를 빅데이터로 구성한 뒤 건강관련 부서와 연동하여 기존에 의사들이 더 정확한 진단을 할 수 있도록 지원한다. 또한 사용자들은 어플을 사용하면서 예방하는데 큰 목적을 둔다.

  • PDF