• 제목/요약/키워드: contact length

검색결과 752건 처리시간 0.036초

Development of a Crawler Type Vehicle to Travel in Water Paddy Rice Field for Water-Dropwort Harvest

  • Jun, Hyeon-Jong;Kang, Tae-Gyoung;Choi, Yong;Choi, Il-Su;Choi, Duck-Kyu;Lee, Choung-Keun
    • Journal of Biosystems Engineering
    • /
    • 제38권4호
    • /
    • pp.240-247
    • /
    • 2013
  • Purpose: This study was conducted to develop a rubber-crawler type vehicle as a traveling device for harvesting water-dropwort cultivated in water contained paddy rice field in winter season. Methods: A commercial rubber-crawler type vehicle was used to investigate application of rubber crawler to the paddy rice field as preliminary test. As the result of the preliminary test, a both prototype traveling device with rubber crawlers for a water-dropwort harvest was designed with inclination of $45^{\circ}$ at the front-end and rear-end of crawler under the basic water depth of 0.6 m in the paddy rice field. The device was fabricated and attached to the experimental harvesting test devices on the front of the prototype vehicle. The size of the prototype crawler vehicle with a harvesting part is $2,800{\times}1,460{\times}1,040 $ (mm) ($L{\times}W{\times}H$) with weight of 9.21 kN (maximum). Sizes of the crawler of prototype vehicle are ground contact length of 900 mm, width of 180 mm, height of 1,070 mm and distance between center to center of crawlers of 720 mm. The side-overturn angle of the prototype was $26.4^{\circ}$. Results: Driving performance of the prototype vehicle in water contained paddy field were good at both forward and reverse (backward) directions as weights were applied. The drawbar pull and the maximum sinking depth of the prototype vehicle were 3.5 kN and 0.13 m respectively at water depth of 0.5 m, when the weight and bearing capacity of the prototype rubber crawler in the paddy field were 8.51 kN and 26.3 $kN/m^2$, respectively. Conclusions: Results of the driving test performance of the prototype crawler in paddy rice field at the water depth of 0.5 m were satisfactory. The prototype had enough drawbar pull and driving ability in the deep water contained paddy field.

열전대(thermocouple)를 이용한 Buchanan Plugger 표면의 온도상승 분석 (ANALYSIS OF TEMPERATURE RISE ON THE SURFACE OF BUCHANAN PLUGGER USING THERMOCOUPLE)

  • 조진숙;황윤찬;김선호;황인남;최보영;정영진;정우남;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제28권4호
    • /
    • pp.334-340
    • /
    • 2003
  • This study was performed to evaluate the actual temperature rise on the surface of Buchanan plugger using thermocouple. The heat carrier system 'System B Heatsource'(Model 1005, Analytic Technologies, Redmond, WA, USA) and the Buchanan pluggers of F, FM, M and ML sizes are used for this study. The temperature was set to 200^{\circ}C on digital display and the power level on it was set to 10. Five thermocouples were placed in direct contact with the surface of each size of Buchanan's pluggers at 1 mm increments from the tip to the 4 mm length of shank. The heat control spring was touched for 5 seconds. and the temperature rise on the surface of the pluggers were measured at 1 sec intervals for more than 5 seconds with an accuracy of 0.01 using Data Logger. The data were statistically analyzed by one-way ANOVA. The results were as follows. 1. The position at which the temperature peaked was approximately at 1~2 mm far from the tip of Buchanan plugger (p<0.01). 2. The peak temperature was $215.25{\pm}2.28^{\circ}C$ in F plugger. $185.94{\pm}2.19^{\circ}C$ in FM plugger, $169.51{\pm}9.12^{\circ}C$ in M plugger, and 160.79{\pm}1.27^{\circ}C in ML plugger and the peak temperature was highest in F plugger and followed by. in descending order. FM plugger. M plugger. ML plugger showed the lowest peak temperature (p<0.01). 3. The temperature on the plugger was decreased with the increase of touching time. This results suggest that the actual temperature on the surface of the pluggers does not correlate well with the temperature set on digital display. Heat concentrates around the tip. The larger plugger reveals lower temperature rise relatively.

정신과 입원환자의 입원기간에 따른 불안정도에 관한 연구 (A Study of the Anxiety Levels of Hospitalized Psychiatric Patients in Terms of Length of Hospitalization)

  • 김윤희
    • 대한간호학회지
    • /
    • 제11권1호
    • /
    • pp.45-63
    • /
    • 1981
  • This study was done to determine the relationship between the anxiety levels of hospitalized psychiatric patients and various influencing variables. The purpose of this study was to determine factors that may help hospitalized psychiatric patients to experience lower levels of anxiety in relation to changing situations and provide the basic data for a dynamic approach which is important in the field of modern psychiatric nursing that understands and analyses the meaning of patients behavior. The anxiety may produce stress, which is a common experience among all human beings. Patients may merely feel uncomfortable in the state of mild anxiety, however, the severe state could be an obstacle to treatment and recovery from disease. The anxiety of the psychiatric patient is a factor which greatly influencing the patient's behavior, so his disorderd behavior is an expression of defence or pathologically fixed behavior. According the psychiatric patient's anxiety at the time of admission is the concern of the health team. The nurse's special concern has to do with understanding and supporting the patient and meeting his individual needs by frequent close contact during the entire hospitalization period, compared to other teamembers the nurse's responsibility in this regard is greated. So this study emphasizes the necessity of creating conditions these, but above all the psychiatric nurse should create a therapeutic environment by not only regarding the patient's behavior or symptoms but understanding the meaning of them. The subjects of this study were 57 psychiatric patients selected from the K neuropsychiatric hospital located in Kunsan city. Data were collected twice from the same patients within a 24 hour period after admission and 10 days after admission. (September 18th to November 8th, 1980). The data collected method was through direct interview, and the interview time was 20 minutes for each patient. Data analysis included Item Analysis & Internal Consistency Reliability Tests, Percentages, t-test, analysis of variance and stepwise multiple regression analysis. The findings of this study were as follows. A. Test of Hypothesis a. Hypothesis 1 :“The anxiety level of psychiatric patients within 24 hours after admission will be higher than those of the same patients 10 days after admission,”was accepted. (t = 3. 15 ; p < 0.005) b. Hypothesi 2:“The more the number of admissions the higher the level of anxiety related to two categories”, was accepted. (affective anxiety: F = 5.50, p < 0.005, Somatic anxiety: F = 9.12, p <.

  • PDF

백서에 식립한 치과용 임플란트의 골유착에 흡연이 미치는 영향 (INFLUENCE OF CIGARETTE SMOKE INHALATION ON DENTAL IMPLANT OSSEOINTEGRATION IN THE RAT)

  • 김세호;김성민;김지혁;박영욱;박찬진;정기명;이석근
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제31권4호
    • /
    • pp.291-299
    • /
    • 2005
  • Objectives : It is well known that cigarette smoking is harzardous to the osseointegration of dental implant, due to the impaired wound healing accompanied by reduced alveolar bone density. The aim of this study is to evaluate the influence of cigarette smoke on the implant osseointegration by the time factor consideration. Materials and methods : Twenty-four male Spraque-Dawley rats (8 weeks, weighting 200 to 250g) were used in this study. In the experimental group, 13 rats were exposed to cigarette smoke, 8 minutes per day during 6 weeks, and 12 rats in the control group were not exposed at any time. RBM (Resorbed blasting media) surfaced implant (diameter 3.3mm, length 5.0mm, AVANA Co., Korea) was placed in the right femur of each rat. Each implant with surrounding bone was prepared with microtome (cutting band 0.2mm$^{(R)}$, EXAKT Co., Germany) after 1 day, 2, 4, 8 and 12 weeks and stained with toluidine blue (1%). Another clinical investigation of each implant was also done at each evaluation time. Results : Clinical investigation around implant fixture showed that there were no significant differences between the control and experimental group. Microscopic observation around implant fixture showed that there were significant differences between the control and experimental group at the initial stage after implant fixture installation. Experimental group showed a decreased bone to implant contact within 4 weeks compared to control group, but showed similar characteristics after 4 weeks. Conclusion : Smoking inhalation effect on the dental implant showed the impaired wound healing by vasoconstriction and decreased intramedullary blood flow at initial stage of osseointegration. This experimental results can be clinically useful to the implant surgery of smoking patients.

유절치 조기 상실 후 공간 상실 (SPACE LOSS AFTER PREMATURE LOSS OF PRIMARY INCISOR)

  • 최병재;한연선;김성오;이종갑
    • 대한소아치과학회지
    • /
    • 제29권3호
    • /
    • pp.407-412
    • /
    • 2002
  • 유치에서의 조기 상실은 부위에 따라 주된 원인이 다르다. 구치부의 조기 상실은 주로 치아우식증에 의해 일어나지만, 전치부에서 나타나는 조기 상실의 대부분은 유아가 서고 걷는 것을 배울 시기에 외상을 받아 유발되며, 다발성 우식증 등에 의해서도 일어날 수 있다. 유치의 조기 상실시 치열궁 길이 감소가 나타날 경우에는 계승 영구치의 맹출을 방해하여 영구치의 총생, 매복 및 치열궁 비대칭 등을 유발할 수 있으므로, 공간 유지에 대한 고려가 필요하다. 유구치가 조기 상실된 경우에는 인접치아의 근심 또는 원심 이동으로 공간 상실이 유발되므로, 공간유지장치의 장착이 필수적이다. 그러나, 유절치의 경우에 있어서는 치아간의 접촉이 긴밀하거나 총생이 있는 유치열의 경우와 유견치의 맹출 전에 유절치가 상실된 경우에는 공간 상실이 일어날 수 있으나, 그 이외에 치간 공간이 있는 유치열의 경우, 유견치의 맹출 후에 유절치가 상실된 경우에서는 공간의 상실이 거의 없는 것으로 알려져 있다. 따라서 유절치 조기 상실 시에는 주로 공간유지 목적보다는 심미 발음장애, 치아결손 부분으로의 혀내밀기 등의 구강습관 방지 등의 목적으로 장치의 장착이 권장되어져 왔으며, 유절치 조기 상실시 공간상실 문제에 대한 증례보고 또한 많지 않다. 본 증례들은 연세대학교 치과대학병원 소아치과에 내원한 환아에게서 유절치의 조기 발거로 인해 장기적 관찰 결과 공간상실이 유발되었기에 이를 통하여 유절치 조기 상실시 공간 상실 가능성에 대해 보고하고자 한다.

  • PDF

Study on the Preparation and Characterization of Ophthalmic Polymer with High and Low-Water Content

  • Lee, Min-Jae;Sung, A-Young
    • 대한화학회지
    • /
    • 제61권6호
    • /
    • pp.346-351
    • /
    • 2017
  • This study was planned considering the chain length, hydrophilicity, and hydrophobicity of the additives to be used in the polymerization, while various ophthalmic lenses that use various additives with similar water contents were manufactured before their optical and physical properties were compared and analyzed. With regard to the additives required for manufacturing high-, medium-, and low-water content lens groups, HEA (hydroxyethyl acrylate), PVP (polyvinylpyrrolidone), and NMV(N-methyl-N-vinylacetamide) were used as additives for preparing the high-water content lens group, HEMA(2-hydroxyethyl methacrylate), HPMA(hydroxypropyl methacrylate) and BD(1,4-butanediol) were used for the medium-water content lens group. For the low-water content lens group, BMA(buthyl methacrylate), BDDA(1,4-butanediol diacrylate), and Bis-GMA(bisphenol A glycerolate diacrylate) were used, respectively. The average water content of HEA was 40.14%; that of PVP, 39.63%; and that of NMV, 40.52%. The mean of water content was 35.92% for HEMA, 35.74% for BD, and 34.62% for HPMA. For the low-water content lens group, the mean of water content was 26.69% for BMA, 27.76% for BDDA, and 26.14% for Bis-GMA. With regard to the results of the water content measurement using a moisture analyzer, the average water content of the high-water content lens group was 41.34% for HEA, 42.62% for PVP, and 42.73% for NMV. Finally, for the low-water content lens group, the average water content was 28.62% for BMA, 28.82% for BDDA, and 28.32% for Bis-GMA. The measurements of the water contents of the lenses using the two methods showed that the water content and refractive index of the lenses were similar in all the lens groups. The measurements of the contact angles, however, showed a different wettability value for each lens with a similar water content. Also, the change tendency of the lens curvature according to the change of time showed that the change amount became larger and the recovery time became longer from the lens samples with a lower water content to those with a higher water content. Based on these results that will be helpful for the study of ophthalmic lenses.

방사선 조사 망상골이 외방형 골형성에 미치는 영향 (The effect of irradiated cancellous human bone on exophytic bone formation in residual ridge of the beagle dog)

  • 정미현;허익;권영혁;박준봉;정종혁
    • Journal of Periodontal and Implant Science
    • /
    • 제37권4호
    • /
    • pp.791-803
    • /
    • 2007
  • The purpose of this study was to evaluate exophytically vertical bone formation in residual ridge of the beagle dog by the concept of guided bone regeneration with a titanium reinforced e-PTFE membrane combined with irradiated cancellous human bone. Twelve male beagle dogs(mean age 1.5 years and mean weight 12kg) were used for this study. The alveolar ridges after extraction of all mandibular premolars were surgically and horizontally removed. At 8 weeks after extractions, full-thickness flap was reflected and cortical bone was removed with round bur and copious irrigation. Rectangular parallelepiped(10mm in length, 5mm in width, and 4mm in height) bended with titanium-reinforced e-PTFE(TR e-PTFE) membrane was placed on the decorticated alveolar ridge, fixed with metal pins and covered with full-thickness flap and assigned as a control group. Test groups ere treated with TR e-PTFE membrane filled with irradiated cancellous human bone. Of twelve beagle dogs, four control dogs and four test dogs without membrane exposure to oral cavity were sacrificed at 8 and 16 weeks respectively. The surgical sites were dissected out, fixed in 4% buffered formaldehyde, dyed using a Villanueva staining technique, and processed for embedding in plastic resin. The cutting and grinding methods were routinely processed for histologic and histomophometric analyis of exophytic bone formation as well as statistical analysis. The results of this study were as follows: 1. Exophytic bone formation in the both of experimental groups was increased respectively after surgery from 23.40% at 8 weeks to 46.26% at 16 weeks in the control groups, from 40.23% at 8 weeks to 47.11% at 16 weeks in the test groups(p<0.05). 2. At 8 weeks after surgery, exophytic bone formation was made 40.23% in the test groups and 33.40% in the control groups. Exophytic bone formation was significantly made in the test group more than in the control group. At 16 weeks after surgery, exophytic bone formation was made 44.11% in the test groups and 46.26% in the control groups. Exophytic bone formation was made in the test groups more than in the control groups, but there was no statistically significant differences. 3. The membrane was fixed with metal pins to closely contact it to the bone surface. So, collapse and deviation of the membrane could be prevented and in growth of connective tissue also could be blocked from the periphery of the membrane. On the basis of these findings, wee suggest that intraoral experimental model for exophytic bone formation may be effective to evaluate the effect of bone graft material. And it indicates that combined use of membrane and ICB graft material is more effective than use of membrane only for exophytic bone formation.

탄성파 굴절법 탐사를 이용한 지반 속도분포 해석-터널 및 절토 사면에의 적용 사례 (Interpretation on the subsurface velocity structure by seismic refraction survey in tunnel and slope)

  • 유영준;조창수;박용수;유인걸
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 1999년도 제2회 학술발표회
    • /
    • pp.48-64
    • /
    • 1999
  • 탄성파 굴절법 탐사를 이용한 지반조사시 탐사 결과로부터 표토층 및 풍화대 깊이, 연암 또는 기반암의 심도, 단층 파쇄대나 연약지반의 위치 및 규모, 지질경계 등을 파악, 지하 속도분포를 도출함으로서 Rippability 등 지반 공학적 특성의 정량적 평가가 가능하다. 양질의 자료 취득을 위하여는 조사목적과 탐사심도에 맞는 측선길이 및 배치, 수진점과 진원점 간격 및 배치, 지형기복 여부 등 현장조사 파라미터의 설정이 중요하다. 택지개발 지역의 절토 사면부에서는 수진점 간격을 3${\~}$5m, 터널 지역에서는 5${\~}$10m 정도가 적합하며 측선의 배열은 주측선과 주요 지점에서 이에 사교하는 부측선 배치가 필요하다. 굴절법 토모그라피 해석기법의 적용시, 조사장비의 가용 채널 수에 1/2 이상의 진원점으로부터 자료를 취득해야 자료처리시 지형의 영향을 받지 않는다. 편마암 지대인 절토사면부에서 시추자료와 비교하여 탄성파 속도에 의한 지반분류는 토사 700m/s 이하, 풍화암 700${\~}$l,200m/s, 연암 1,200${\~}$l,800ni/s이고 굴삭난이도(리퍼빌리티)는 리핑암 700~l,200m/s, 발파암 1,800m/s 이상으로 나타났다. 터널 지역에서는 전통적인 해석기법을 적용하였으며 터널 계획고와 탄성파 속도 1,200m/s${\~}$l,900m/s에 해당되는 연암층과 접하는 구간에서는 지질조사 및 비저항 탐사결과로부터 해석된 3개의 지질 구조선과 만나고 있으므로 터널 설계/시공 시 이의 결과 반영이 필요하다.

  • PDF

인태아 상경신경절 발육에 관한 전자현미경적 연구 (Ultrastructural Study on Development of the Superior Cervical Ganglion of Human Fetuses)

  • 김대영;김백윤;윤재룡
    • Applied Microscopy
    • /
    • 제28권2호
    • /
    • pp.139-158
    • /
    • 1998
  • The development of the superior cervical ganglion was studied by electron microscopic method in human fetuses ranging from 40 mm to 260 mm of crown-rump length (10 to 30 weeks of gestational age). At 40 mm fetus, the superior cervical ganglion was composed of clusters of undifferentiated cell, primitive neuroblast, primitive supporting cell, and unmyelinated fibers. At 70mm fetus, the neuroblasts and their processes were ensheated by the bodies or processes of satellite cells. The cytoplasm of the neuroblast contained rough endoplasmic reticulum, mitochondria, Golgi complex, Nissl bodies and dense-cored vesicles. As the neuroblasts grew and differentiated dense-cored vesicles moved away from perikaryal cytoplasm into developing processes. Synaptic contacts between the cholinergic axon and dendrites of postganglionic neuron and a few axosomatic synapses were first observed at 70 mm fetus. At 90 mm fetus the superior cervical ganglion consisted of neuroblasts, satellite cells, granule-containing cells, and unmyelinated nerve fibers. The ganglion cells increased somewhat in numbers and size by 150 mm fetus. Further differentiation resulted in the formation of young ganglion cells, whose cytoplasm was densely filled with cell organelles. During next prenatal stage up to 260 mm fetus, the cytoplasm of the ganglion cells contained except for large pigment granules, all intracytoplasmic structures which were also found in mature superior cervical ganglion. A great number of synaptic contact zones between the cholinergic preganglionic axon and the dendrites of the postganglionic neuron were observed and a few axosomatic synapses were also observed. Two morphological types of the granule-containing cells in the superior cervical ganglion were first identified at 90 mm fetus. Type I granule-containing cell occurred in solitary, whereas type II tended to appeared in clusters near the blood capillaries. Synaptic contacts were first found on the solitary granule-containing cell at 150 mm fetus. Synaptic contacts between the soma of type I granule-containing cells and preganglionic axon termials were observed. In addition, synaptic junctions between the processes of the granule- containing cells and dendrites of postganglionic neuron were also observed from 150 mm fetus onward. In conclusion, superior cervical ganglion cells and granule-containing cells arise from a common undifferentiated cell precursor of neural crest . The granule-containg cells exhibit a local modulatory feedback system in the superior cervical ganglion and nay serve as interneurons between the preganglionic and postganglionic cells.

  • PDF

CMOS 소자 응용을 위한 Plasma doping과 Silicide 형성

  • 최장훈;도승우;서영호;이용현
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.456-456
    • /
    • 2010
  • CMOS 소자가 서브마이크론($0.1\;{\mu}m$) 이하로 스케일다운 되면서 단채널 효과(short channel effect), 게이트 산화막(gate oxide)의 누설전류(leakage current)의 증가와 높은 직렬저항(series resistance) 등의 문제가 발생한다. CMOS 소자의 구동전류(drive current)를 높이고, 단채널 효과를 줄이기 위한 가장 효율적인 방법은 소스 및 드레인의 얕은 접합(shallow junction) 형성과 직렬 저항을 줄이는 것이다. 플라즈마 도핑 방법은 플라즈마 밀도 컨트롤, 주입 바이어스 전압 조절 등을 통해 저 에너지 이온주입법보다 기판 손상 및 표면 결함의 생성을 억제하면서 고농도로 얕은 접합을 형성할 수 있다. 그리고 얕은 접합을 형성하기 위해 주입된 불순물의 활성화와 확산을 위해 후속 열처리 공정은 높은 온도에서 짧은 시간 열처리하여 불순물 물질의 활성화를 높여주면서 열처리로 인한 접합 깊이를 얕게 해야 한다. 그러나 접합의 깊이가 줄어듦에 따라서 소스 및 드레인의 표면 저항(sheet resistance)과 접촉저항(contact resistance)이 급격하게 증가하는 문제점이 있다. 이러한 표면저항과 접촉저항을 줄이기 위한 방안으로 실리사이드 박막(silicide thin film)을 형성하는 방법이 사용되고 있다. 본 논문에서는 (100) p-type 웨이퍼 He(90 %) 가스로 희석된 $PH_3$(10 %) 가스를 사용하여 플라즈마 도핑을 실시하였다. 10 mTorr의 압력에서 200 W RF 파워를 인가하여 플라즈마를 생성하였고 도핑은 바이어스 전압 -1 kV에서 60 초 동안 실시하였다. 얕은 접합을 형성하기 위한 불순물의 활성화는 ArF(193 nm) excimer laser를 통해 $460\;mJ/cm^2$의 에니지로 열처리를 실시하였다. 그리고 낮은 접촉비저항과 표면저항을 얻기 위해 metal sputter를 통해 TiN/Ti를 $800/400\;{\AA}$ 증착하고 metal RTP를 사용하여 실리사이드 형성 온도를 $650{\sim}800^{\circ}C$까지 60 초 동안 열처리를 실시하여 $TiSi_2$ 박막을 형성하였다. 그리고 $TiSi_2$의 두께를 측정하기 위해 TEM(Transmission Electron Microscopy)을 측정하였다. 화학적 결합상태를 분석하기 위해 XPS(X-ray photoelectronic)와 XRD(X-ray diffraction)를 측정하였다. 접촉비저항, 접촉저항과 표면저항을 분석하기 위해 TLM(Transfer Length Method) 패턴을 제작하여 I-V 특성을 측정하였다. TEM 측정결과 $TiSi_2$의 두께는 약 $580{\AA}$ 정도이고 morphology는 안정적이고 실리사이드 집괴 현상은 발견되지 않았다. XPS와 XRD 분석결과 실리사이드 형성 온도가 $700^{\circ}C$에서 C54 형태의 $TiSi_2$ 박막이 형성되었고 가장 낮은 접촉비저항과 접촉저항 값을 가진다.

  • PDF