A Study on Self-Actualization Level of junior College Nursing Students (간호전문대학생의 자아실현에 관한 연구)

  • 하양숙
    • Journal of Korean Academy of Nursing
    • /
    • v.24 no.3
    • /
    • pp.499-510
    • /
    • 1994
  • The purpose of this study was to Identify the self-actualization level of Junior College Nursing Students and to analyze the variables that may be related to self-actualization. A convenient sample of 346 students were selected from three colleges located in Seoul and Kyungki-Province. The data were collected using a direct survey method from September17to October 2, 1992. The instrument used for this study was the self-actualization test modified by Kim & Lee(1983). The collected data were analyzed using percentages, means, 1-test, X$^2$-test, ANOVA and Pearson’s correlation coefficient, with the SPSSPC$^{+}$ Package. The results of this study are as follows : 1) The self-actualization level of subjects was moderate. The subjects showed higher scores in the areas of Self actualizing Values and Nature of Man than the standardized normal groups. The subjects showed lower scores in the areas of Inner Directed Existentiality, Self acceptance and Capacity for Intimate Contact. 2) The subjects attending day junior colleges showed higher scores in the areas of Time competent, Existentiality and Self Acceptance than those attending college in the evening. The subjects attending evening junior colleges showed higher scores in the areas of Spontaneity than those attending college by day. 3) The junior students showed higher scores in the areas of Feel-ing Reactivity than freshman. The students with no religion showed higher scores in the areas of existentiality than those who had a religion. The group who had the experience of failure on the college entrance examination showed lower scores in the areas of Nature of Man than those without this experience. Those who chose their major voluntary showed scores higher in the areas of I nor Directed, Self Actualizing Values, Spontaneity and Self regard than the unsatisfied group. The group satisfied with college life showed higher scores in the areas of Time Competent, Inner Directed, Self Actualizing Values and Self Regard than the unsatisfied group. In conclusion self actualization level depends on motivation of choice, satisfaction with nursing as a major and satisfaction with college life. Therefore, and effective guidance program is required to improve motivation and satisfaction with nursing as a major and with college life.

  • PDF

Effects of Entrepreneurship Education Based on Relative Policies Link (창업교육연계의 효과측정모형 및 정책제안)

  • Seol, Byung-Moon
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.7 no.2
    • /
    • pp.9-17
    • /
    • 2012
  • This paper integrates elements from the theory of agency, the entrepreneurship education, the start-up policies. Entrepreneurship education is demanded to enhance success of business candidate for business establishment and to increase start-up survival. Three researches are made by this study. First of all, Educational performance is measured and it explains why linked policies is needed. To explain linked performance, this paper introduces several hypothesis. These are about a rate of start-up failure caused by agency problem and a rate of education effect decreasing agency problem. Secondly, operation performance of it can be increased by linking among policies and should be for the original goals of start-up policies. Finally, several ideas including start-up certification is proposed. Start-up certification has role of contact point of different entrepreneurship policies. As a result, level of satisfaction of policies will increase and specially of education program by linked effects.

  • PDF

An Analysis on the Deformation of Foundation Using the Interface Element Method (접합요소(接合要素)를 이용(利用)한 기초지반(基礎地盤)의 변형해석(變形解析))

  • Park, Byong Kee;Lee, Jean Soo;Lim, Sung Chull
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.10 no.1
    • /
    • pp.155-162
    • /
    • 1990
  • In analysis of deformation in which the stiffness is greatly different between the adjacent materials, the desired results have been obtained by using the interface element method compared with those secured by the conventional method of the concept of continua. However the interface element method was originally developed for the behavior of rocks. This study deals with the deformation analysis of foundation with sand drain by the introduction of interface element. The physical conditions of interface element are devided into three categories by Mohr-Coulomb failure criterion ie. sliding, separation, and contact. Finally the accuracy of the program proposed in this paper is proved highly accurate by performing the comparison of the theoretical values and numerical results of a model element with simplified boundary conditions.

  • PDF

A Study on Auxiliary Control Safety Apparatus for RCD Trip on Electric Arc and Spark Disasters - Using by Power Semiconductor Switching Device - (아크 및 스파크 재해에 대한 누전차단기 트립을 위한 보조제어 전기안전장치에 관한 연구 - 전력용 반도체 스위칭 소자 적용 및 응용 -)

  • Kwak, Dong-Kurl;Shin, Mi-Young;Jung, Do-Young
    • Fire Science and Engineering
    • /
    • v.20 no.1 s.61
    • /
    • pp.71-76
    • /
    • 2006
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Device(RCD) of high sensitivity type used at low voltage wiring cuts off earth leakage and overload, but the RCD can't cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied low voltage distribution panel are prescribed to rated breaking time about 30[ms](KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To be improved on such problem, this paper is proposed to a auxiliary control apparatus for RCD trip on electric arc or spark due to electrical fire. Some experimental results of the proposed apparatus is confirmed to the validity of the analytical results.

Mechanical Loads of Dropper for High Speed Electric Railway (고속 전차선로 드로퍼에 대한 기계적 하중에 관한 연구)

  • Lee, Gi-Chun;Lee, Tae-Hoon;Lee, Jong-Woo
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.3
    • /
    • pp.222-227
    • /
    • 2011
  • The dropper supports the contact wire and is attached using various types of dropper clips on the catenary. Droppers are subject to mechanical stress from buckling during the passage of pantographs. In order to investigate failure causes for the high speed line dropper, theoretical analyses and experiments have been carried out. In this paper, mathematical formulas are derived for the pre-sag of the dropper static load. The measured values in the experiment were similar to the theoretical predictions. To analyze the cause on fracture of dropper wire, we have conducted analysis such as SEM(Scanning Electron Microscope) of fractured specimens in the field and new specimens. Finally, we performed measurement for the variation of dynamic load on the dropper when a pantograph moved at 300km/h under the Korean high speed overhead line. If such mechanical load occur repeatedly with every passing pantograph, it is possible that the dropper wire will break due to fatigue. This results will be used for special management of high speed catenary system maintenance and life estimation of dropper.

Cap Formation Process for MEMS Packages using Cu/Sn Rim Bonding (Cu/Sn Rim 본딩을 이용한 MEMS 패키지의 Cap 형성공정)

  • Kim, S.K.;Oh, T.S.;Moon, J.T.
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.15 no.4
    • /
    • pp.31-39
    • /
    • 2008
  • To develop the MEMS cap bonding process without cavity formation, we electroplated Cu/Sn rim structures and measured the bonding characteristics for the Cu/Sn rims of $25{\sim}400{\mu}m$ width. As the effective device-mounting area ratio decreased and the failure strength ratio increased for wider Cu/Sn rim, these two properties were estimated to be optimized for the Cu/Sn rim with 150 ${\mu}m$ width. Complete bonding was accomplished at the whole interfaces of the Cu/Sn packages with the rim widths of 25 ${\mu}m$ and 50 ${\mu}m$. However, voids were observed locally at the interfaces with the rim widths larger than 100 ${\mu}m$. Such voids were formed by local non-contact between the upper and lower rims due to the surface roughness of the electroplated Sn.

  • PDF

Ultimate Strength Analysis of Stiffened Plate with Minor Collision Damage (작은 충돌손상을 가진 보강판의 최종강도 해석)

  • Lee, Tak-Kee;Rim, Chae-Whan
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.226-229
    • /
    • 2006
  • The safety of on-going ships is one of important concerns in the view of environment and human life. The ship in bad condition is likely to be subjected to accidental loads such as collision. Once she has one or several minor collision damages in the form of circle or ellipse, her ultimate strength under compression or tension load will be reduced. Here, it is important to evaluate the reduction ratio of ultimate strength due to the damage from safety point of view. The problem of strength reduction of a plate with cutout such as opening hole has been treated by many researchers. As a result, a closed-form formula on the reduction of ultimate strength of a plate considering the effect of several forms of cutout was suggested. However, the structure of ships is composed of a plate and a stiffener so-called a stiffened plate, and it is likely to be damaged at a plate and stiffeners together in collision. This paper is to investigate the effect of minor collision damage on ultimate strength of a stiffened plate by using numerical analysis. For this study, the shape of minor collision damage of a stiffened plate was made by using contact algorithm. The deformed shape was used as an initial shape for ultimate stress analysis. Then, a series of nonlinear FE analysis was conducted to investigate the reduction effects of ultimate strength of the stiffened plate. The boundary condition was applied as simply supported at all boundaries, and the tripping of stiffener among failure mode under compression loading was neglected. These results were settled in the form of reduction ratio between ultimate of original intact stiffened plate and that of damaged stiffened plate.

  • PDF

UHF Sensor Development for Partial Discharge Exclusively for Measurement in 25.8kV GIS (25.8kV GIS 부분방전 측정전용 UHF센서 개발)

  • Choi, Mun-Gyu;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.1083-1088
    • /
    • 2016
  • 25.8kV GIS part generated by sensors to measure contact an inflow of noise depending on the extent of the measured discharge occurs often not easy. Partial discharge signal measurement sensor suitable for developing a more useful measurements at the scene to this, partial discharge waveform analysis developed a sensor, and to utilize forSensor on the development of the most important is VSWR decided to (voltage standing wave ratio) voltage standing-wave ratio less than 1.5 and decided less than at the full spectrum bands that are measured, this time Return loss, as measured value by absolute criteria 14.0 dB produced the sensor, designed to or more. UHF 1.5~0.5 GHz bandwidth spectrum to be measured in GIS. UHF bands were designed to be able to measure the best signal. Recently, 25.8kV GIS production company has been increasing variety of GIS were made open spacer in partial discharge in accordance with the not very easy to detect the signal. The sensor is designed height of four cm external spacer is attachment GIS in an influx of outside noise measurement, and be so manufactured as to facilitate the least we've done. Also, since partial discharge which occur can measure the frequency of the 170kV GIS external partial-discharge signals that occur at the scene of insulation applied to the spacer. Features, and also derived good results using global positioning. Also measured discharge point about sensors that are stable and the reliability of the development and local substation equipment failure occurring signal analysis through the discharge for the prevention of widely. There should be to believe that used.

A Study on the Effects of Chemical Grout on the Shear Strength of Fresh Granite Joints (신선한 화강암 절리면에서 약액에 의한 전단강도의 변화에 대한 연구)

  • Chung, Hyung Sik;Lee, Seung Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.99-106
    • /
    • 1990
  • This study was aimed to see the effect of chemical grout on fresh granite joint shear strength. The grouting chemical used in this study was composed of 25% water glass. Direct shear tests were performed on the chemical filled joints, which had been made artificially with granite. The test results show that chemical grouted rock jonts have markedly reduced shear strength comparing with the ungrouted fresh joints and they sheared within chemical grout before the rock to rock contact had been established, while the ungrouted joint sheared between rock surfaces from the beginning of shear deformation. With chemical grouted joints the shear stress slowly reached its maximum without showing distinct peak shear strength. Therefore the shear stiffness of joints were decreased with increasing thickness of grout. but the shear strain at failure was increased with it.

  • PDF

Arc Discharge Sensor having Noise Immunity to Ambient Light (주변광 영향을 받지 않는 아크방전 감지 센서)

  • Roh, Hee Hyuk;Seo, Yong Ma;Khishigsuren, J.;Choi, Kyoo Nam
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.726-728
    • /
    • 2013
  • Optoelectronic arc discharge sensor was used to detect arc discharge inside power distribution panel. Arc discharge is fatal to power system once it begins, thus preventive detection is necessary before power failure occurs. Optoelectronic detection method was used to avoid direct electrical contact to power apparatus inside power distribution panel. 180 degree detection angle and detection range far exceeding 6m, which was sufficient for monitoring purpose, was achieved using the photodiode having $7.5mm^2$ of active surface area and flash source with $0.4cal/cm^2$ energy density, which is equivalent to 1.9J with $2.16cm^2$ emitting area. The response speed of arc discharge sensor was measured to be below 1 msec. The above optoelectronic arc discharge sensor was measured to be sensitive enough to detect 0.94 pC charge.

  • PDF