친환경 가스 중 전극과 고체절연체의 불량접촉에 관한 절연진단연구 (Study on Insulation Diagnosis of Poor Contact between Electrode and Solid Insulator in Eco-Gas)

  • 임동영;최은혁;배성우;최상태;이광식;최병주
    • 조명전기설비학회논문지
    • /
    • 제29권10호
    • /
    • pp.97-103
    • /
    • 2015
  • This paper presents the characteristics of partial discharge and radiated electromagnetic waves in the existence of a poor contact for the insulation diagnosis of eco-friendly power equipment. AC surface discharge experiment was conducted to simulate the poor contact between a hive voltage electrode (anode) and a solid insulator in $N_2/O_2$ mixture gas under a non-uniform field. The partial discharge voltage to be measured at 0.3MPa increased with the increase of the poor contact gap and was saturated with the gap. In addition to the partial discharge characteristics, it was verified that the defect of the poor contact can be diagnosed using the radiated electromagnetic waves due to the partial discharge, which measured by a biconical EMC antenna and a spectrum analyzer.

광계측기를 이용한 전차선-팬터그래프 재질별 이선아크 스펙트럼 분석 (Analysis of Contact Loss Arc Spectrum between Contact Wire and Pantograph Material using a Spectrometer)

  • 장진영;정노건;박종국;구경완;김재문
    • 전기학회논문지
    • /
    • 제62권12호
    • /
    • pp.1803-1808
    • /
    • 2013
  • To maintain contact between catenary and pantograph copper is important in order to transmit power smoothly on Current collection system. But, Arc discharge with strong light is generated because of contact loss. Therefore, Arc discharge detection is important measurement factor judging performance of current collection system. In this paper, It is described to results of arc discharge applying UV detection technology using arc generator. And Arc discharge was detected using the most commonly used processing catenary and rigid catenary and pantograph copper of electric rolling stock for securing arc detection instrument reliability. Results of contact loss detection instrument in this paper will be used for maintenance of current collection quality and system.

분만 직후 어머니의 신생아 접촉이 모아애착행위에 미치는 영향 (A Study of the Effects of Behavior Contact in Early Mother-Infant Attachment)

  • 성미혜;김미경
    • 대한간호학회지
    • /
    • 제35권5호
    • /
    • pp.842-849
    • /
    • 2005
  • Purpose: The main purpose of this study was to establish a nursing intervention data base to improve maternal attachment. Method: The first group of mothers( control group), experienced their first physical contact with their infants after being discharged from the hospital. The second group (experimental group) practiced early initial mother-infant postpartum contact known as the most sensitive period for founding maternal-infancy attachment. The subjects of this study gave birth to normal infants at M hospital from Aug.25 to Sept.30, 2004. During the same time, data was collected through direct observation, with instruments designed by Cropley et al., to assess the behaviors of normal attachment. The statistical methods for data analysis were percentage, mean, standard deviation and t-test with an SPSS program. Result: The group practicing initial mother-infant contact, showed a higher degree of physical and functional bonding than the group experiencing the first contact after discharge from the :10spital (control group)(p<.0l). The group practicing initial mother-infant contact, showed higher degrees of bonding attachment assessments than the group experiencing their first initial contact after their discharge from the hospital(p<.01). Conclusion: The group practicing early mother-infant contact, showed more maternal-infant interaction than the group experiencing their initial contact after their discharge from the hospital. These results show that maternal attachment behavior increases according with an early initial mother-infant contact.

고압 나트륨램프의 점등과 소등을 위한 제어기의 릴레이 접점의 융착 방지 (The Prevention of Melting Contact in Accordance Relay of Controller for Turn on/off High Pressure Sodium Vapor Lamp)

  • 한태환;우천희
    • 전기학회논문지P
    • /
    • 제53권3호
    • /
    • pp.148-151
    • /
    • 2004
  • For turn on high pressure sodium vapor lamp, Starting Voltage is very important factor. This starting voltage supply to high pressure sodium vapor lamp as electric discharge lamp, Electric field is producted in electric discharge tube, So accelerative electron collide against vapor atom and second electron is generated, And rapidly the current flow to electric discharge tube. This starting voltage is high voltage and source for melting contact that relay is according as turn on/off high pressure sodium vapor lamp. Consequently, This paper propose that the prevention of melting contact in accordance relay of controller for turn on/off high pressure sodium vapor lamp.

장기 코로나 처리에 따른 RTV 실리콘 절연재료의 특성변화 (Effect of Long-term Corona-discharge on RTV Silicone Rubber)

  • 연복희;안종식;허창수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.266-269
    • /
    • 2001
  • This paper investigated the aging characteristic under long-term corona discharge on roan temperature vulcanized silicone rubber, which has been using as a protective coating material for solving the contaminant problem. The applied electrical field is 10kV/cm ac and corona discharge treatment was applied on RTV silicone rubber sheet for maximum 250 hours. With the duration of corona discharge. the diffusible low molecular weight species increased, which was determined the usage of n-hexane extraction method. In addition, the contaminant layer was formed on the treated surface, and then measured the contact angle. We investigated the relation of contact angle and diffusible low molecular weight species. It is found that scissor of main chain PDMS and side chains $(CH_3)$ and the generation of LMW species were occurred by a corona discharge. The improvement of hydrophobicity rate is thought due to the increase of diffusible LMW species.

  • PDF

장기 코로나 처리에 따른 RTV 실리콘 절연재료의 특성변화 (Effect of Long-term Corona-discharge on RTV Silicone Rubber)

  • 연복희;안종식;허창수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.266-269
    • /
    • 2001
  • This paper investigated the aging characteristic under long-term corona discharge on loon temperature vulcanized silicone rubber, which has been using as a protective coating material for solving the contaminant problem. The applied electrical field is 10kV/cm ac and corona discharge treatment was applied on RTV silicone rubber sheet for maximum 250 hours. With the duration of corona discharge, the diffusible low molecular weight species increased, which was determined the usage of n-hexane extraction method. In addition, the contaminant layer was formed on the treated surface, and then measured the contact angle. We investigated the relation of contact angle and diffusible low molecular weight species. It is found that scissor of main chain PDMS and side chains (CH$_3$) and the generation of LMW species were occurred by a corona discharge. The improvement of hydrophobicity rate is thought due to the increase of diffusible LMW species.

  • PDF

히터 일체형 하이브리드 단판형 플라즈마 방전소자 (One-Plate Type Hybrid Plasma Discharge Device with Heating Element)

  • 최우진;최은혜;성형석;권진구;이성의
    • 한국전기전자재료학회논문지
    • /
    • 제32권4호
    • /
    • pp.320-326
    • /
    • 2019
  • Recently, the application of atmospheric plasma technology in air filtration is increasing. Sterilization by an atmospheric plasma device is very effective. However, ozone gas, which is generated during atmospheric plasma formation, poses a hazard to human health. To reduce the ozone gas during plasma discharge, we fabricated a one-plate hybrid plasma discharge device with a heating element, which can decompose ozone gas effectively by a simple heating action. In this study, we evaluated the plasma discharge characteristics and ozone concentrations with various Ar flow rates and temperatures. With increasing Ar gas flow rate, the ozone concentration and spectrum intensity increased till an Ar gas flow rate of 60 sccm, and decreased thereafter. When discharged in high temperature, the ozone concentration and spectrum intensity decreased. Further, to evaluate the state of the treated surface under various plasma discharge and heating conditions, we measured the variation in the contact angles on the surface. Regardless of the temperature, the contact angle increased with increasing discharge voltage. However, the contact angle increased when discharged at high temperature.

대기압 플라즈마 처리에 의한 TAC 필름의 표면에너지 변화 (The Surface Energy Change of TAC Film Treated by an Atmospheric Pressure Plasma)

  • 이창호;정도영;박영직;송현직;이광식
    • 조명전기설비학회논문지
    • /
    • 제23권12호
    • /
    • pp.184-190
    • /
    • 2009
  • 표면의 친수성 작용기 형성과 접촉각 향상을 위하여 대기압 플라즈마를 이용하여 Tri-acetyl-cellulose(TAC) 필름에 대한 표면개질을 연구하였다. TAC 필름의 표면개질 목적으로 대기압에서 플라즈마를 발생시키기 위한 Dielectric barrier discharge(DBD) 구조의 플라즈마 반응기 내에서 이온화된 질소 플라즈마를 사용하였다. 플라즈마 처리 공정변수인 처리속도, 방전전력, 방전 갭 및 질소 가스 유속을 변화시켜가며 접촉각을 측정하여 접촉각과 표면에너지 변화를 검토하였다. 대기압 플라즈마 처리속도 100[mm/sec], 방전 전력 1.5[kW], 방전 갭 2[mm] 및 $N_2$ 가스유량 140[LPM] 에서 가장 높은 접촉각과 표면에너지 값을 보였다. 표면친수화의 정도는 플라즈마 방전 전력과 처리 시간에 의존하였다.

대기압 RF DBD 방전으로 개질된 폴리이미드의 표면특성 (Surface Properties of Polyimide Modified with He/O2/NF3 Atmospheric Pressure RF Dielectric Barrier Discharge)

  • 이수빈;김윤기;김정순
    • 한국재료학회지
    • /
    • 제16권9호
    • /
    • pp.543-549
    • /
    • 2006
  • Polyimides (PI) are treated with $He/O_2$ and $He/O_2/NF_3$ atmospheric pressure rf dielectric barrier discharge in order to investigate the roles of $NF_3$ that is one of the PI etching gases. Surface changes are analyzed by x-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), and contact angle measurement. The surface roughness of PI and the ratio of C=O, which is hydrophilic functional group, is more increased by $He/O_2/NF_3$ discharge than by $He/O_2$ discharge. The C=O species on the PI surface is increased up to 30 percent with rf power. The surface roughness of PI is increased from 0.4 to 11 nm with rf power. The water drop contact angles on PI, however, are reduced from $65^{\circ}\;to\;9^{\circ}$ by plasma treatment independently of $NF_3$.

코로나 방전처리에 따른 실리콘 고무의 표면특성 변화 (Surface Characterization of Silicone Rubbers by Corona Discharge)

  • 홍주일;서유진;이기택;황선묵;허창수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.503-506
    • /
    • 2004
  • In this paper we investigated the changes of surface hydrophobic characteristics on silicone rubbers by corona discharge treatment and also investigated the distribution and the behavior of low molecular weight(LMW) silicone fluid which was extracted by solvent-extraction with gel permeation chromatography(GPC). It was shown that contact angle was $110.5^{\circ}$ on initial sample but contact angle was approximately decreased to $10^{\circ}$ after 45 minutes. However the surface hydrophobic characteristic on silicone rubbers which were removed from corona discharge was recovered within 5 hours. It was shown that corona discharge insured the increase of diffusible LMW chains, which could lead to recover the surface hydrophobicity. The surface hydrophobic characteristics on silicone rubbers and the recovery mechanism based on our results were discussed.

  • PDF