• Title/Summary/Keyword: construction joint

Search Result 1,115, Processing Time 0.033 seconds

Experimental Study On shear Capacity of P.C Vertical Joints (P.C 수직접합부의 전단내력에 대한 실험연구)

  • 김원종;김상식;지호청
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.10a
    • /
    • pp.362-367
    • /
    • 1994
  • In Precast Concrete Structure, safety of structure depends on strength of joint. Asa result, there exists a necessity to review the effects of elements consisting joints, since these elements are important factors for evalaution of joint strength. However, there elements are different for construction methods and may be changed even during construction. Obviously, the change of elements can cause the change of joint strength; yet, the effects of the variables are not clearly defined. The behavior of the joints are complicated and evaluated only through experiments. Consequently, the main objective of this paper is to review effects of components consisting Precast Joints, I order to keep higher joint strength than specified in the design code.

  • PDF

A Study on Verification Test of T-MAT Type Expansion Joint for Railway Bridge (철도교량용 T-MAT형 신축이음장치 완제품 성능시험에 관한 연구)

  • Yoo Moon Sig;Woo Yoon Soo;Kim Hyun Mook;Choi Jong Moon;Yoon Tae Yang;Lee An Ho
    • Proceedings of the KSR Conference
    • /
    • 2003.10b
    • /
    • pp.552-556
    • /
    • 2003
  • Expansion joint is the absorbing structure when the upper structure of bridge have the drying shrinkage and creep from the change of temperature or construction badness. Because it has the fatigue from continuous vehicles traffic. the durability and performance is verified by the static and dynamic loading test In this study. we make the decision that T-MAT type expansion joint is applied in railway bridge and the expansion joint was tested by the criterion of Korea High Speed Rail Construction Authority.

  • PDF

A Study on Early Strength Estimation of Precast Concrete joint Mortar with Microwave (마이크로파에 의한 PC접합모르타르의 조기강도추정에 관한 연구)

  • 원준연;박일용;백민수;이종균;안형준;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.217-222
    • /
    • 2000
  • A large Pc structure building is system that consisted of bearing wall and slab joint. It has general structure stability from unity thar each members tied at joint. The strength of mortar that packing in joint among panels is important to internal force in entire building system. Do, if we could get early strength estimation with microwave. It would bring good construction planning, reduce construction time, and judge building stability and so on. The purpose of this study is to develop early estimation method for making better quality control and constructing good PC panel structure. The results of this study were as follows :1) With sealed molds, reduced moisture volatilization to more than 60% and enlarged 30% accelerated compressive strength than before one. 2) To get more accelerated strength, we should control maximum temperature difference to $30^{\circ}C$ downward 3)Interrelation with 7-day and 28-day strength were 0.831,0.902, and it is above than before one

  • PDF

Experimental Study of the Joint Movement Responsiveness Performance to the One-Component Silicon Sealants at Curing Phase (경화단계에서의 1성분형 실리콘 실란트의 거동대응성능에 관한 실험적 연구)

  • Son, Jong-Won;Ono, Tadashi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.63-64
    • /
    • 2014
  • In this study, we has a purpose to estimate the joint movement responsiveness performance for the domestic products of one-component structural silicon sealants. For this purpose, we make a comparative study for the four domestic products focused on tensile properties after allowed the cyclic-movements for three days at initial step of curing phase. A joint movement range ±10% and the rate of compression and extension 3.2mm/h were assumed in those tests. As a result, the large space were induced inside the sealant by rupture, and then adhesion and cohesion failures were caused by stress concentration. The tensile properties were reduced by 15~60% in comparison with physical properties. In this case, the generating defect was caused and the service-life was decreased. Thus, further researches as relationship of test condition and products properties on this behavior would be studied.

  • PDF

Non-destructive Leakage Location Analysis Method in Substrate Behavior Response Testing of Waterproofing Membrane Systems using Thermal Emission Camera

  • Oh, Kyu-Hwan;Jiang, Bo;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.47-48
    • /
    • 2017
  • The substrate behavior response testing outlined in KS F 2622 evaluates the leakage cause of waterproofing membrane systems when subjected to the concrete joint load behaviors by removing the waterproofing layer after testing, relying mostly on visual observation and subjective analysis. A non-destructive leakage cause and failure type analysis method is proposed currently in this study by the means of detecting leakage paths using thermal emission imaging systems. Test specimens are placed in varying temperature conditions after the concrete joint movement testing and are scanned using the thermal emission camera to determine the location and dimension of the adhesion failure/leakage path beneath the waterproofing membranes.

  • PDF

Heating Properties and Pore structure of Cementitious Joint by Induction Heating (시멘트계 접합부의 유도가열에 의한 승온특성 및 공극구조)

  • Kang, Dong-Woo;Ahn, Jae-Cheol;Kim, Jung-Kil;Kang, Byeung-Hee
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05a
    • /
    • pp.3-4
    • /
    • 2011
  • The purpose of this study is to suggest basic data for development optimal disassembly manufacturing system during analysis pore structure and heating properties of cementitious joint using conductive resister by induction heating. From the results, we knew cementitious joint is weak easily by heating of conductive resister, such as wire mesh, punching metal, and steel fiber, from induction heating.

  • PDF

Design and Structure Improvement of Jig Joint Area (지그접합부의 설계 및 구조개선)

  • Lee, Jong-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.6
    • /
    • pp.1332-1336
    • /
    • 2007
  • This paper aims to design zig joint three dimensionally in order to secure accurate construction of a long bridge and suggests an improved structural consideration applying a simulation techniques to solve occurring problems at zig joint area. This preliminary simulation approach may improve the efficiency of construction engineering and enhance technical competitive since many budgets are involved in the manufacturing of zig.

  • PDF

A study on the welding performance of korean automatic gas pressure welding machine by external appearance investigation (외관검사를 통한 한국형 철근자동가스압접기의 압접성능 연구)

  • Seo, Deok-Seok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.6
    • /
    • pp.161-166
    • /
    • 2008
  • This study is focused on the welding performance of automatic gas pressure welding machine adapted to korean construction site by external appearance investigation. As gas pressure welding is more economical and has good performances compared with other steel bar jointing methods, as arc welding and mechanical joint etc, in Japan, the gas pressure welding is one of the typical connection of steel reinforcement when connecting the D29 and thicker steel bars, But in Korea, gas pressure welding joint method is not widely used caused by the shortage of skilled workers. so to activate the gas pressure welding in Korea, the automatic gas pressure welding machine is developed. In this study, the welding performances of gas pressure welding joint samples using korean automatic gas pressure welding machine are measured by external appearance investigation - blown diameters, blown length, welding face disagreement, central axis eccentric ratio, bending, sag and crack. The results of welding performances on the gas pressure welding joint samples show that samples are satisfied with the standard value regulated in KS D 0244 and JIS Z 3120.

Towards a model of dry shear keyed joints: modelling of panel tests

  • Turmo, J.;Ramos, G.;Aparicio, A.C.
    • Computers and Concrete
    • /
    • v.10 no.5
    • /
    • pp.469-487
    • /
    • 2012
  • This paper presents a study on the behaviour of the joints of segmental concrete bridges with external prestressing, focusing on the structural response of dry non-epoxied joints with shear keys. A Finite Element joint model to study such structures is validated modelling eight concrete panel tests. The most important feature of this model is that it has been validated with experimental tests on concrete panels which were specifically designed to fail in shear. Interface elements are used to reproduce the non linear behaviour of the joint and parameters deduced from the tests are used to define the constitutive law of these elements. This joint model is of great importance because it will permit the development of a structural model that faithfully reproduces the behaviour of these structures under combined flexure and shear and the study of its global behaviour after the opening of the joints. Interesting conclusions about the behaviour of the dry joints, about the contribution of the different mechanisms transferring shear (friction and cohesion) and about the shear stress distribution in the joint have been reached.

Evaluation of Suitable Application of ultra high-strength Concrete to V.H Separated Placement (VH분리타설 공법의 초고강도 콘크리트 적용성 평가)

  • Kim, Hak-Young;Ki, Jun-Do;Park, Hyun;Lim, Byung Chun;Lee, Young Do;Jung, Sang Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.23-26
    • /
    • 2009
  • Despite vigorous studies on ultra high-strength concrete in Korea, it still faces many challenges in application to on-site construction methods. This study intends to evaluate the applicability of the VH separated-pouring method which is currently used and was designed to pour ultra high-strength concrete with a design strength of 60, 100N/㎟ separately to girder and beam. When it comes to VH separated-pouring, there is a difference in the required design strength between a girder and a beam, which tends to be larger for ultra high-strength concrete. The tensile strength and cold joint at the joint end have not been commonly evaluated and thus the inevitably of its use is dependent on a structural analysis of the structural stress of reinforcement. In the study, potential problems with respect to the building material which might occur during the pouring of ultra high-strength concrete was evaluated and issues on joint surface performance, the hydration energy contained in the members, and the effects of contraction in concrete were considered as the key elements for study.

  • PDF