Flexural analysis of transverse joints of prefabricated T-girder bridge superstructure

  • Kye, Seungkyung;Jung, Hyung-Jo;Park, Sun-Kyu
    • Structural Engineering and Mechanics
    • /
    • 제77권1호
    • /
    • pp.89-102
    • /
    • 2021
  • Rapid construction of prefabricated bridges requires minimizing the field work of precast members and ensuring structural stability and constructability. In this study, we conducted experimental and analytical investigations of transverse joints of prefabricated T-girder bridge superstructures to verify the flexural performance and serviceability. In addition, we conducted parametric studies to identify the joint parameters. The results showed that both the segmented and continuous specimens satisfied the ultimate flexural strength criterion, and the segmented specimen exhibited unified behavior, with the flexural strength corresponding to that of the continuous specimen. The segmented specimens exhibited elastic behavior under service load conditions, and the maximum crack width satisfied the acceptance criteria. The reliability of the finite element model of the joint was verified, and parametric analysis of the convexity of the joint section and the compressive strength of the filler concrete showed that the minimum deflection and crack width occurred at a specific angle. As the strength of the filler concrete increased, the deflection and crack width decreased. However, we confirmed that the reduction in the crack width was hardly observed above a specific strength. Therefore, a design suitable for prefabricated bridges and accelerated construction can be achieved by improving the joint specifications based on the required criteria.

인천국제공항 3단계 건설부지에 적합한 지중열교환기 시스템 평가 연구 (Evaluation of a Ground Heat Exchanger Appropriate for the Site of the Third Stage Construction of Incheon International Airport)

  • 조남현;송정태;윤석;이승래
    • 한국지반공학회논문집
    • /
    • 제31권5호
    • /
    • pp.23-33
    • /
    • 2015
  • 본 연구에서는 인천국제공항 3단계 건설 사업에 포함된 지중열시스템에 대한 적정 지중열교환기 선정을 위해 현장 부지내 시스템의 열원(지중열원, 지하수), 채움재(벤토나이트, 콩자갈), 열교환 파이프 형태(U, D-U)별로 지중열교환기를 설치하여 지중열전도도, 시공성, 경제성을 평가하였다. 이를 위해 벤토나이트 그라우트에 single U형의 열교환파이프가 삽입된 일반수직밀폐형-I, 열교환 파이프의 접촉면적을 늘려 열교환율을 높이기 위해 single U형 열교환파이프를 두 개 삽입한 Double U형 일반수직밀폐형-II, 일반수직밀폐형-I의 채움재를 벤토나이트 대신 콩자갈로 적용한 개량수직밀폐형 및 SCW(standing column well)에 채움재를 넣은 함몰방지개방형(geohil)을 시험시공하였다. 초기비용에 대한 비용 비교분석결과 일반수직밀폐형-I 대비 개량수직밀폐형, 일반수직밀폐형-II의 경우 초기비용이 절감되었지만 시공성(채움재 주입, 열교환 파이프 삽입) 및 시공일수를 고려할 때 높은 경제성을 기대하기 어려우리라 판단된다. 또한 Geohil의 경우 초기 비용이 더 늘어났다.

국내외 비정형 건축물 외피시스템 사례 분석을 통한 설계 및 시공시 고려사항 도출 (Deduction of Considerations During Design and Construction by Analysing Domestic and Abroad Case Analysis of Freeform Building Envelope)

  • 류한국
    • 한국건설관리학회논문집
    • /
    • 제14권4호
    • /
    • pp.84-96
    • /
    • 2013
  • 최근 건설 산업의 디지털화로 인하여 건축 디자인이 정형에서 자유로운 비정형 형태로 변화하고 있다. 특히, 국내에서는 최근 비정형이 디자인 경향으로 도입되어 현상설계, 턴키 등에서 설계 당선을 위한 디자인 요소로 많이 적용되고 있다. 그러나 기존의 정형 건축물의 외벽공법을 비정형 건축물의 외피에 그대로 적용함으로써 누수 및 크랙 등 다양한 하자가 발생하고 있다. 이러한 문제점을 개선하고 공사기간과 공사비를 최소화할 수 있는 비정형 건축물의 설계와 시공이 새로운 기술로 도입되고 있다. 이에 본 연구는 비정형 외피시스템 구현을 위한 공법을 국내외 비정형 건축물의 외피시스템 사례 분석을 통하여 실증적으로 시사점을 도출하고 비정형 건축물 외피시스템의 설계와 시공시 고려해야 할 사항을 다음과 같이 제시하였다. 첫째, 시공성을 고려한 비정형 형태의 설계가 되도록 하여야 한다. 둘째, 2방향 곡면을 정확히 구현할 수 있는 단위 패널 생산 기술의 개발이 필요하다. 셋째, 비정형 콘크리트 외피용 노출 콘크리트 거푸집을 개발하여야 한다. 넷째, 외피 시스템을 부위별로 구분하여 우수처리와 방수를 위한 재료와 공법 특성과 유지관리 방안을 고려하여야 한다.

Half-Deck을 포함한 60 m 경간 PSC 거더의 단면 및 텐던 프로파일 최적화 연구 (A Study on the Optimum Cross-section and Tendon Profiles of 60 m span Half-Decked PSC Girder Bridge)

  • 김태민;김도학;김문겸;임윤묵
    • 대한토목학회논문집
    • /
    • 제31권6A호
    • /
    • pp.417-424
    • /
    • 2011
  • 본 연구에서는 60 m 급의 장경간 PSC 거더의 개발을 위하여 단면 개선부터 텐던 배치 형상까지 구조적인 성능뿐만 아니라 경제성과 시공성 등을 고려해가며 거더 개발에 관한 연구를 진행하였다. 단면 최적화를 통해 Bulb-T 형의 단면을 도출하였고 단면 평가를 통해 실제 설계 가능성을 평가하였다. 또한 텐던의 배치를 효율적으로 구성하여 사용하중에 대해 효과적으로 대처할 수 있도록 하였다. 실제 대상교량을 선정한 후 개발 거더를 적용해 유한요소해석을 수행한 결과, 모든 하중단계에서 설계 허용응력을 만족하였다. 또한 사용하중에 의해 발생하는 응력이 허용하중보다 작아 안전측 설계가 가능한 것으로 나타났다. 이를 바탕으로 실물 크기의 60 m 거더를 제작해 4점 실험을 실시한 결과 초기 균열이 사용하중의 2배 이상에서 발생하여, 실험 결과를 통해서도 충분한 구조적 성능을 입증하였다. 본 연구를 통해 개발된 Half-Decked PSC 형식의 60 m 거더는 단면개선과 효율적인 텐던 배치로 경간대비 매우 낮은 형고를 갖게 되었고, 구조적인 이점은 물론 경제성이나 시공성 등에서도 큰 장점을 가질 것으로 판단된다.

사무용 건축물의 자연채광 설계 및 시공사례 연구 (A case study on design and construction of daylighting system of office building)

  • 김일호;최용준;박경우;이성진
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.59.2-59.2
    • /
    • 2010
  • Throughout history, daylight has been a primary source of lighting in buildings, supplemented originally with burned fuels and more recently with electrical energy. Before daylight was supplemented or replaced with electric light in the late 19th-century, consideration of good daylight strategies was essential. As we entered the mid-20th-century, electric light supplanted daylight in buildings in many cases. Fortunately, during the last quarter of the 20th-century and early years of this century, architects and designers have recognized the importance and value of introducing natural light into buildings. There are many simple strategies that can enhance daylighting and reduce the need for electric lights. Good quality daylight is always welcome, but remember that the electric lights must be dimmed or shut off in order for daylighting to save energy. We designed and built mirror systems and vertical daylighting devices to improve daylight condition of office buildings in bad condition because urban density is getting higher. This case study aims to analysis the principles and characteristics of mirror systems and vertical daylighting devices and selected the method that can improve constructability. The results of this study are going to use the back data to set-up the design standards. Hereafter we're going to progress the performance test and product the design manual to improve applicability of daylighting systems at design phase.

  • PDF

공동주택 관리비용에 따른 적정공간규모 산정에 관한 연구 -경유, 등유를 사용하는 중앙집중난방방식을 중심으로 - (A Study on the Space Size Analysis in the Multifamily Housing in aspect of management cost. -Focused on the Central Heating System using the diesel, kerosene-)

  • 이강희;양재혁
    • 한국주거학회논문집
    • /
    • 제13권5호
    • /
    • pp.89-99
    • /
    • 2002
  • The multifamily housing has various advantages in construction cost, land-use intensity. KRIHS(1997) recommended the proper scale of th multifamily housing as 800 households in constructability, 1,000 households in facility compactability, 500 households in social aspect. At the early planning stage of project, the size of the multiftmily housing has, until now, been maximizingly considered under the regulation on which has been emphasized at the building volume ratio, land area, etc., except for the expenditure during the maintenance stage. This paper aimed at providing the proper size of multifamily housing in aspect of area and household number with maintenance cost at the early stage of project. For these, it took 곧 average cost function which is made from the 3-rd quardratic form and analyzes the unit increasing rate of the average cost. It surveyed in nationwide focused on the central heating system using diesel and kerosene. The number of samples is 88 and items of management cost is 11. The results are as follows ; first, 3rd-order quadratic function is proper at explaining the cost variation, considering the multicollinearity and statistics. Second, the proper size of multifamily housing is recommended with 83,000 $m^2$ on management area, 820 or over the 2,630 household number in aspect of total management cost.

건설 엔지니어링 생산성 향상을 위한 Application Program Interface(API) 활용방안에 대한 연구 (A Study of the Using Application Program Interface (API) for Improving Productivity in Construction Engineering)

  • 박기백;정영호;함남혁;김재준
    • 한국BIM학회 논문집
    • /
    • 제3권3호
    • /
    • pp.29-38
    • /
    • 2013
  • Domestic construction industry is larger in size, and its shape is more complex. As a result, collaboration and information management tasks are difficult to manage in a way that conventional 2D-based exchange of information. BIM technology was introduced as a solution for this. But BIM only provides a very limited set of features such as Constructability review, clash detection in reality. and duplication of work and a lot of iterations occurs in BIM process. Thus, it takes quite a lot time to work. We studied how to improve the work efficiency by connecting API to business processes. Using the API in the integration process by automating repetitive tasks, reduce a significant amount of work time Using API (Automation, Optimization, Interoperability, Analysis) can solve the task problem that does not solved by the basic features, If we make good use of the combined API will be improved productivity.

탄소판가새를 이용한 농촌 저층건물의 내진보강 (Seismic Reinforcement of Rural Low-rise Building using Carbon Fiver Plate)

  • 정동조;최성대
    • 한국농촌건축학회논문집
    • /
    • 제16권2호
    • /
    • pp.1-8
    • /
    • 2014
  • In the past, Korea was classified as a region not affected by earthquakes. However, recent increase of earthquakes has forced to strengthen standards of earthquake resistant designs of structures to minimize seismic damage. In addition, it was thought that masonry infill walls in buildings are only acting as partitions, so these walls are not considered in analyzing building structures. But it was found that when seismic loads are applied to a structure with masonry infill walls, the walls affect the structure. Accordingly, this study conducted nonlinear static analyses for a structure constructed before applying earthquake resistant designs in two cases: when considering masonry walls and when not. The result showed that the seismic performance of the structure is insufficient. Thus, the structural resistance of the structure was also studied in two cases: when reinforcing with steel plate braces and when using carbon fiber braces. In the two cases reinforcing two different stiffeners, it was appeared that the behaviors of the structure were similar, though the cross-section area of a carbon fiber brace used to reinforcing the structure is only 12.6% of a steel plate brace, and its weight is only 2.8%. Thus, the reinforcing effect of the thin, light-weighted carbon fiber brace is much larger than that of the steel plate brace, when considering usability and constructability of both materials.

무소음.무진동 스크류말뚝공법의 수치해석에 의한 거동 연구 (A Study on the Behavior of a Noise & Vibration-Free Screw Pile Method by Means of numerical analysis)

  • 김영필;정호영;하영민;오승률;최용규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.30-37
    • /
    • 2009
  • In doing the foundation work in the downtown, the popular complaints by means of Noise and vibration have been became heavy burden. Therefore, the noise & vibration-free screw PHC pile method will contribute to the foundation work by removal of the popular complaints and improvement of the constructability. In this paper, the load bearing capacity and displacement characteristics of the noise & vibration-free screw PHC pile were analyzed. The noise & vibration-free screw PHC pile's behavior was better well than the existing PHC pile's one.

  • PDF

Revitalization Methods of EIFS for High-rise Residential Buildings through Using TACT and Gangform System with Hanging Scaffolding

  • Lee, Sang-Hyun;Yi, June-Seong;Shin, Seung-Woo;Kang, Hae-Min
    • 한국건축시공학회지
    • /
    • 제11권4호
    • /
    • pp.407-418
    • /
    • 2011
  • Recently energy management measures at the political level, for the purpose of reducing energy consumption in the building sector, are being actively introduced. As a practical method, the exterior insulation method, which is proven to effective in reducing the energy loss through walls, has been favored. In this study, detailed implementations are suggested to activate exterior insulation system which can improve the housing insulation performance. The newly designed Gang-form system with hanging scaffolding was suggested to revamp constructability for finishing outer wall. The research results are based on a multifaceted analysis of the current problems of exterior insulation systems, and on recommendations proposed by exterior insulation experts in the Charrette discussion. The study has indicates that the customized TACT schedule considering the site condition has shortened the construction period to 5 months from 7.5 months. Through utilizing the suggestions of this study, the prevalence of exterior insulation systems is expected to become widespread.